Sell Used PG6541B Combined Cycle Power Plant |
Total 10 Related Items
|
|
|
||||||||||||||||||||||||||
| This power plant is built in 1997. It is only operated during the peak times of power consumption. The starts time of NO.1 and NO.2 generating set are 895 and 869, the running hours are 5388 hours and 4939 hours. The two generating set are interim overhaul in April and October of 2004. And the statues and conditions are all very good so far.
1.1 GAS TURBINE DESIGN DATA MANUFACTURER:GEC ALSTHOM UNIT(S)NUMBER (S):T766, T768 TYPE: PG6541B GAS TURBINE APPLICATION: GENERATOR DRIVE CYCLE: SIMPLE COMPRESSOR: STAGES: 17 SPEED: 5100R.P.M. TURBINE: STAGES: 3 SPEED: 5100 R.P.M. INLET AIR FLOW: 401400m3/h INLET AIR PRESSURE DROP: 100mmH2O TURBINE INLET TEMPERATURE: 1104'C EXHAUST GAS TEMPERATURE: 533'C EXHAUST PRESSURE DROP: 30 mmH2O 1.2 GENERATOR: MANUFACTURER: GEC ALSTHOM TYPE: T190-240 3 PHASES YEAR OF MANUFACTURE: 1996 COOLING BY: AIR RATED OUTPUT: 44.882MVA RATED VOLTAGE: 11000V RATED CURRENT: 2356A POWER FACTOR: 0.85 AMBIENT TEMPERATURE: 15'C SPEED: 3000RPM FREQUENCY: 50HZ CLASS OF INSULATION: F EXCITATION: 249V 515A ALTITUDE:<1000M 1.3 MAIN TRANSFORMER: MANUFACTURER: CHANGZHOU TRANSFORMER COMPANY TYPE: SFZ8-50000/110 PHASE: 3 RATED FREQUENCY: 50HZ RATED CAPACITY: 50000KVA RATED VOLTAGE: 115KV X 1.25%/11 CONNECTION: YNd11 COOLING: AIR COOLING LV WINDING: VOLTAGE: 11000V; CURRENT: 2642A NO LOAD CURRENT: #1 0.17% #2 0.21% NO LOAD CONSUME: #1 32.40KW #2 30.8KW LOAD CONSUME: #1 204.73KW #2 209.02KW 110KV SF6 BREAKER MANUFACTURER: GEC ALSTHOM TYPE: FXT11 QUANTITY: 5 U: 123KV f: 50HZ In: 2000A ISC: 25KA tth: 3S If interested in, pls don't hesitate to contact us for more information. |