Category Picks : Pharmaceutical Chemicals, Herb Medicine, Monitoring & Diagnostic Equipment, Sex Products, Other Health Care Products, More...
There are 2939 X-ray from 1127 suppliers on EC21.com
Related Searches : X-ray , digital x-ray system , digital x-ray equipment , radiography
Brand Name :
Digital X-Ray Equipment
Model Number :
DDR Inventor-V
Place of Origin :
Korea
Related Keywords : X-ray , digital x-ray system , digital x-ray equipment , radiography , scanogram , scoliosis
Description
< Scanning Digital X-ray System >
Tags: digital x-ray Digital Radiography x-ray scoliosis chiropractic x-ray image
Overview
DDR Inventor-V for Long Bone is a linear X-ray scanner which is designed to produce high quality, distortion free images with very low X-ray doses. It is designed to capture the whole spine & long bone image of a standing patient with a single scan without the need for stitching or vertical distortion. This lack of vertical distortion provides true size images in 1:1 scale for highly accurate measurements. Clever design also ensures equally high quality small body part sectional imaging.
DDR Inventor-V adopts MIC detector with direct conversion of incident X-ray to electric signal, high fill factor without dead zone and without dead pixel, as well as a scanning system that can prevent scattered radiation with fan beam. These characteristics of MIC detector provide merit of high image quality with low dose irradiation against patient.
DDR Inventor-V works by means of a vertical drive mechanism which moves the X-ray source and detector along the vertical axis to cover a field of up to 42 x 110 cm in a single continuous scan. It takes a maximum of 2.5 seconds and 5 seconds to do a chest and long body scan respectively. As soon as the scan is completed, data processing and digital image acquisition takes place within 2 seconds. The image produced is scalable allowing medical personnel to look at the full spine or long bone in one glance or zoom into a specific detail. In addition, the image, being digital, can be easily distributed. The system is fully PACS compatible for DICOM distribution and management.

Health System Benefits
Economic Operation & Maintenance
DDR Inventor-V is an economic solution, since the MIC detector boasts long life time with consistent image quality. Supplied as a complete integrated system, the system price is far below comparable existing FPD DR system. FPD DR plates in particular are fragile and expensive. CR plates are inherently subject to wear. The MIC detector used in DDR Inventor-V does not suffer from wear or exhibit interpixel dead zones and is possible to replace if damaged. In addition, use of the DDR Inventor-V requires up to 80% less time to manage patients and display an image than CR; this may speed up the consultation process and potentially decrease associated staff costs.

High image quality and Low dose irradiation - Perfect detector
DDR Inventor-V, Scan Digital Radiography for Long Bone, adopts MIC(Multi-channel lonization Chamber) detector which has intrinsic features of high efficiency by direct conversion of incident X-ray to electric signal, high fill factor without dead zone and without dead pixel and adopts scanning system which can prevent scattered radiation with fan beam. These characteristics of MIC detector provide merit of high image quality with low dose irradiation against patient
Convenient & Compatible Software
DR-Works, based on DICOM, is completely compatible with HIS(Hospital Information System). The hospital even without PACS can manage patient information and images independently with its own viewer and database.
Economic Operation
DDR Inventor-V is an economic solution, since MIC detector has long lifetime due to its non-sensitivity to temperature, humidity, vibration, and treatment. Also, JSB can provide a full-coverage of customer service in short time, since it has its own technology on core parts and keeps sufficient inventory.
Advantages of Long Image
Needlessness of long size cassette
Arbitrary image size, Maximum 16"x39" image(ex. Whole spine, Long bone)
Great efficiency on chiropractic study(1:1 scale of vertical direction)
System Specifications
|
X-RAY Generator
|
Power rating
|
68kw
|
|
Line nominal, phase
|
230vac~, 400/480V33~
|
|
|
kV range
|
40 to 125kV, 1kV step, 40 to 150kV for V33~
|
|
|
mA range
|
10 to 500mA
|
|
|
Time range
|
0.001 to 10sec, 38 steps
|
|
|
mAs range
|
0.1 to 500mAs(Optional higher mAs)
|
|
|
Anatomical programs
|
User programmable mas 1,280 programs with APR utility software
|
|
|
X-RAY TUBE
|
Max kVP
|
150kV
|
|
Focal spot
|
0.6/1.2mm
|
|
|
Max HU
|
1,000,000HU
|
|
|
Anode rotation
|
2,700RPM at 50Hz
3,200RPM at 60Hz 8,100RPM at 150Hz 9,700RPM at 180Hz |
|
|
Target angle
|
12°
|
|
|
Detector
(MSGC) |
Detector type
|
Micro strip gas chamber type linear detector
|
|
Receptor type
|
Gas ionization
|
|
|
Image size
|
410mm x 1,100mm(16" x 43")
|
|
|
Fill factor
|
Almost 100%
|
|
|
Pixel pitch
|
200μm
|
|
|
Matrix of pixel
|
2,048 x 5,710(max)
|
|
|
A/D conversion
|
14Bit
|
|
|
Resolution
|
205lp/min
|
|
|
Scan speed
|
10,14,21cm/sec
|
|
|
Scanning time
|
5sec(21cm/sec. for 39")
|
|
|
Review time
|
Within 1sec.
|
|
|
Image acquisition time
|
Within 2sec.
|
|
|
Power consumption
|
12W Max
|
|
|
Power requirement
|
60Hz AC220V
|
|
|
Patient Elevator
|
Stroke
|
400mm ±10mm
|
|
Max weight capacity
|
>150kg
|
X-ray Room Layout

Certificates
CE : 11512
Similar products in other categories :
Health & Medical > Monitoring & Diagnostic Equipment > X-Ray Equipment
Browse: Manufacturer Directory Countries China India Korea Premium Suppliers Community Site Map
About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy
中文 繁體 한국어 日本語 Español Русский Français Deutsch
Hot Products : A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Copyright (c)1997-2013 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese
Business Registry Number: 120-86-03931