  • Model Number :Matron

Description

Patient Monitor

Patient Monitor is measuring and monitoring related to patient-hearts such as electrocardiograph waves, respirations, pulses, blood pressure and degree of saturation of oxygen.

Matron

It is ALL in your handgrip, NIBP, IBP, SpO2, ECG, Respiration, Temperature, Battery operation and Stress-free data scrolling functions but a few...

Take it to the Limit.
Protable design and features with an easy-grip handle. Battery operation keeps you mobile anytime, any where.

Full Specification

Display

  • Screen : 10.4" color TFT LCD
  • Resolution : 640 x 480
  • Trace : 6 Max.
  • Sweep Speed " 603 /12.5 / 25 / 50mm/s
  • Indicator : AC power LED, Battery charging LED
  • Alarm suspend LED, Alarm LED

ECG

  • Input : 5-lead (I, II, III, aVL, aVR, aVF, V)
  • ECG waveform : 1Channer (the 2nd waveform cascade)
  • 2Channer (Optional)
  • Sweep speed : 6.3 / 12.5 / 25 / 50mm/s
  • Gain (Sensitivity) : 5 / 10 / 15mm/mV
  • Pulse range : 20 to 300bpm
  • Pulse accuracy : ±2bpm
  • Lead-off Detection : Yes
  • Arrhythmia Analysis : Yes
Respiration

  • Measurement range : 0~150bpm
  • Resolution : 1rpm
  • Accuracy : ±2rpm
  • Apnea delay : 10~40 sec (in 5 sec. Steps)

NIBP

  • Technique : Oscilometric
  • Operation mode : manual
  • Automatic (2/5/10/15/30/60/120min)
  • Inflation pressure range : 0-300mmHg
  • Inflation pressure Max : Adult : 300 ±5mmHg
  • Neonate : 150 ±5mmHg
  • Resoluction : 1mmHg
  • Over-pressure protection : Yes
  • Adult : Systolic(60-270), Diastolic(40-245), Mean(45-255)
  • Neonate : Systolic(50-130), Diastolic(30-100), Mean(40-120)

SpO2

  • Measurement range : 20-100%
  • Measurement range accuracy : ±2%
  • Pulse rate range : 20-300bpm
  • Pulse rate accuracy : ±2bpm
  • SpO2 accuracy : ±2% (70-100%), ±3% (50-69%), 0-49% Unspecified
  • Resolution : 1%

IBP (2 IBP / optional)

  • Measurement range : -40 to 360mmHg
  • Channel : 2 channel
  • Resolution : ±1mmHg
  • Accuracy : ±2mmHg
  • Auto zero balancing range : ±20mmHg
  • Alarm Range : -40 to 360mmHg

Temperature(2 Temperature)

  • Measurement range : 10~45°C
  • Accuracy : 0.1°C

EtCO2 (optional)

  • Measurement mode : Microstream
  • Range :0~99mmHg
  • Accuracy :
    0~38mmHg ±2mmHg
    39~99mmHg ±5%+0,08%
  • for every 1mmHg above 38mmHg
  • Respiration rate : 0~150 breaths per minute
  • Respiration accuracy :
    ±1breaths per minute from 0~70bpm
    ±2bpm from 71~120bpm
    ±3% from 12~150bpm
  • CO2 waveform
  • Recognition : 5mmHg ±2mmHg bandwidth
  • Start-up time : 30seconds typical
  • Sampling rate : 50ml/minute ±7.5ml/min
  • Auto zero : <15seconds at 5, 10, 15 and 60minute then every 60minutes thereafter.

Product Image

  • Patient Monitor

Send an Inquiry to this supplier

Patient Monitor

Patient Monitor

Send an Inquiry to this supplier
* From
  To Mr. Dae-seong, Kim
Bionics Corporation.
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Heart Rate Monitor
* Messages

Use English only Max. 2000 characters. (Min. 20)

Send

Similar products in other categories :

  • Health & Medical >
  • Heart Rate Monitor
  • Search
    You may also be interested in :
    Cctv Lcd Monitor
    Heart Rate Monitor
    Rear View Monitor
    Car Lcd Monitor
    Headrest Monitor
    Open Frame Monitor
    Cctv Monitor
    Fetal Monitor
    Lcd Monitor
    Patient Monitor - Matron Suppliers :
    Cctv Lcd Monitor Suppliers
    Heart Rate Monitor Suppliers
    Rear View Monitor Suppliers
    Car Lcd Monitor Suppliers
    Headrest Monitor Suppliers
    Open Frame Monitor Suppliers
    Cctv Monitor Suppliers
    Fetal Monitor Suppliers
    Lcd Monitor Suppliers
    Patient Monitor - Matron Manufacturers :
    Cctv Lcd Monitor Manufacturers
    Heart Rate Monitor Manufacturers
    Rear View Monitor Manufacturers
    Car Lcd Monitor Manufacturers
    Headrest Monitor Manufacturers
    Open Frame Monitor Manufacturers
    Cctv Monitor Manufacturers
    Fetal Monitor Manufacturers
    Lcd Monitor Manufacturers
    China Patient Monitor - Matron :
    China Cctv Lcd Monitor
    China Heart Rate Monitor
    China Rear View Monitor
    China Car Lcd Monitor
    China Headrest Monitor
    China Open Frame Monitor
    China Cctv Monitor
    China Fetal Monitor
    China Lcd Monitor
    Patient Monitor - Matron Buyers :
    Cctv Lcd Monitor Buyers
    Heart Rate Monitor Buyers
    Rear View Monitor Buyers
    Car Lcd Monitor Buyers
    Headrest Monitor Buyers
    Open Frame Monitor Buyers
    Cctv Monitor Buyers
    Fetal Monitor Buyers
    Lcd Monitor Buyers
    Patient Monitor - Matron Exporters :
    Cctv Lcd Monitor Exporters
    Heart Rate Monitor Exporters
    Rear View Monitor Exporters
    Car Lcd Monitor Exporters
    Headrest Monitor Exporters
    Open Frame Monitor Exporters
    Cctv Monitor Exporters
    Fetal Monitor Exporters
    Lcd Monitor Exporters

    View more searches related to Patient Monitor - Matron

    Browse: Manufacturer Directory Countries China India Korea Premium Suppliers Community Site Map

    About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

    中文 繁體 한국어 日本語 Español Русский Français Deutsch

    Copyright (c)1997-2014 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

    Business Registry Number: 120-86-03931

    Inquiry Basket ()