Search Advanced Search

There are 357 Wireless Communication Terminal from 176 suppliers on EC21.com

Related Searches : wireless, wireless modem, 3g modem, modem, wireless network card, hsdpa

Remote Wireless Communication Terminal of Overhead Type Earth and Short Circuit Fault Indicator

Min Order Quantity 1 set /
Supply Ability 5000 sets per month
Port shenzhen,China
Delivery Lead Time 7 working days
  • Share to :
  • Pinterest
Contact Now* Send an Inquiry to this supplier.
or

Quick Information

  • Brand Name :SNOVA
  • Model Number :SNV-309
  • Place of Origin :China

Description

Smart Electricity Distribution Network Monitoring System

Smart electricity distribution network monitoring system is the use of electronic information and communication technology to detect the distribution network’s short circuits and single-phase ground faults. It enables real-time monitoring, threshold warnings, fault session detection and sending out the fault message. This allows technical personnel to arrive on-site and fix the relevant problems quickly. This system can reduce the reliance on technician experience to identify faults, increase equipment stability and management efficiency. 

                  

Application Scenarios

 

Widely used in cities with overhead electricity lines, cable lines, oil fields, switchgears and other boxed equipments.

                  remote utility ups short circuit overhead earth fault indicator

 

System Composition

The system consists of the fault indicator (acquisition unit), collecting unit and main station server.

Fault indicator (acquisition unit):

Fault indicator is the basis of the whole system; it’s used for collecting real-time data from all test sites.

Collecting unit: When fault indicator detects short circuit or earth fault, the turnover alarm and flashing red light will be triggered immediately, at the same time, the fault information will be transferred to the collecting unit wirelessly through 433M/Lora, and the collecting unit will report it to the main station server through GPRS/CDMA (2G/3G/4G).

Main station server: When the main station server receives the fault information, together with GIS system, the system will provide the time and location information where the fault occurs, to help the maintenance staff identify the fault and fix it in a timely manner.

 

Abnormal Monitoring Indicators, Automatic Flashing, Turnover Alarm And Sending To Main Station Server

 

When there is a fault in the electricity line, the LED light will flash immediately and the alarm will sound. At the same time the fault information is transmitted to the main station server. Once the fault information is received, in combination with the GIS system, the fault location and time will be sent out to a technician who will then rush on-site to fix the problem.

                                       remote utility ups short circuit overhead earth fault indicator

Visible Faulty Site and Clear Line Status

 

When the main station server receives the fault information from the terminal, it will perform a topology analysis, calculating, together with the GIS system to display the fault sites graphically, and clearly displaying the line status.

                                     remote utility ups short circuit overhead earth fault indicator

Powerful Electricity Solutions

1. Powered by electricity line: 10A+ current from the electricity line would be enough for the fault line indicator, extra battery power is not needed in this case.

 

2. Powered by solar energy: The terminal is powered by solar energy, backed up with a high-capacity lithium battery, can operate normally for 30 days in wet/raining weather conditions.

 

3. Low power optimization: The indicator uses an ultra-low power consumption design; average power consumption is less than 20 uA.

 

4. Battery power detection: System will detect power of the backup battery automatically, and will report to the main station server when the power is lower than the preset threshold value, and will have a reminder for you to change the battery.

remote utility ups short circuit overhead earth fault indicator

 

Price

  • Price Condition : FOB
  • Delivery Port : shenzhen,China

Packaging & Delivery

  • Delivery Lead Time : 7 working days
  • Minimum Order : 1 set
  • Supply Ability : 5000 sets per month

Product Image

  • Remote Wireless Communication Terminal of Overhead Type Earth and Short Circuit Fault Indicator

Send an Inquiry to this supplier

Remote Wireless Communication Terminal of Overhead Type ...

Remote Wireless Communication Terminal of Overhead Type ...

Send an Inquiry to this supplier
* From
  To Ms.Betty
Zhuhai Snova Technology Hongkong Co., Ltd
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Wireless Networking Equipment
* Messages

Use English only Max. 2000 characters. (Min. 20)

Send

Similar products in other categories :

  • Telecommunications >
  • Wireless Networking Equipment
  • Search
    You may also be interested in :
    Terminal Block
    Wireless Modem
    Communication Cable
    Wireless Router
    Wireless Keyboard
    2.4g Wireless Mouse
    Wireless Doorbell
    Pos Terminal
    Terminal Box
    Wireless Communication Terminal Suppliers :
    Terminal Block Suppliers
    Wireless Modem Suppliers
    Communication Cable Suppliers
    Wireless Router Suppliers
    Wireless Keyboard Suppliers
    2.4g Wireless Mouse Suppliers
    Wireless Doorbell Suppliers
    Pos Terminal Suppliers
    Terminal Box Suppliers
    Wireless Communication Terminal Manufacturers :
    Terminal Block Manufacturers
    Wireless Modem Manufacturers
    Communication Cable Manufacturers
    Wireless Router Manufacturers
    Wireless Keyboard Manufacturers
    2.4g Wireless Mouse Manufacturers
    Wireless Doorbell Manufacturers
    Pos Terminal Manufacturers
    Terminal Box Manufacturers
    China Wireless Communication Terminal :
    China Terminal Block
    China Wireless Modem
    China Communication Cable
    China Wireless Router
    China Wireless Keyboard
    China 2.4g Wireless Mouse
    China Wireless Doorbell
    China Pos Terminal
    China Terminal Box
    Wireless Communication Terminal Buyers :
    Terminal Block Buyers
    Wireless Modem Buyers
    Communication Cable Buyers
    Wireless Router Buyers
    Wireless Keyboard Buyers
    2.4g Wireless Mouse Buyers
    Wireless Doorbell Buyers
    Pos Terminal Buyers
    Terminal Box Buyers
    Wireless Communication Terminal Exporters :
    Terminal Block Exporters
    Wireless Modem Exporters
    Communication Cable Exporters
    Wireless Router Exporters
    Wireless Keyboard Exporters
    2.4g Wireless Mouse Exporters
    Wireless Doorbell Exporters
    Pos Terminal Exporters
    Terminal Box Exporters

    View more searches related to Wireless Communication Terminal

    Browse: Manufacturer Directory Countries China India Korea Premium Suppliers Community Site Map

    About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

    中文 繁體 한국어 日本語 Español Русский Français Deutsch

    Copyright (c)1997-2017 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

    Business Registry Number: 120-86-03931

    Inquiry Basket ()