There are 48 Urinary Incontinence from 29 suppliers on EC21.com
Related Searches : Urinary Incontinence , Urinary Incontinence Therapy Units
Place of Origin :
Korea
Related Keywords : Urinary Incontinence , Urinary Incontinence Therapy Units
Description
< how to use >
Tags: how to use
| Urinary Incontinence Therapy Units for hospital use HnJ-7000
No insertion Bio-Feedback for hospital use
(Bio-Feedback using in clothes)
Contrary to Insertion Type Bio-Feedback, Dressed Type Bio-Feedback allows the user's pelvic muscle to contract and relax directly against external load as exercising the arms with dumbbells. This helps the bulk of pelvic muscle to be increased quickly enabling to recover the supporting power of the bladder and the urethra. Our Bio-Feedback Equipment is the first "No insertion" in the world.
- How to Work
As the up-to-the-minute Bio-Feedback Equipment, through the sensor located on the center of chair, approx 10 kg weight is pressed on the patient’s pelvic muscle. The pelvic muscle is to be contracted against the physical pressure. Then the power of contraction on the pelvic muscle is sensed and the sensed value is displayed on the computer screen.
(In case of exercising the arms with empty hands, it is hard to apply pressure to the arms contrary to the intention but in case of exercising with 10 kg dumbbells, it is easy to apply pressure to the arms. Such principle is applied to our product.)
- Characteristics
This is the up-to-the-minute product enabling to use conveniently in patient’s clothes and to train by applying 10 kg weight to the pelvic muscle as if exercising the arms with dumbbells. (Up-to-the-minute product developed by picking out only the advantages of Insertion Type Bio-Feedback and Magnetic Therapy Units)
- Advantages
1) Convenient Use : Very convenient in use by using in the state of keeping clothes on.
2) Easy Training : It is hard to apply pressure to the pelvic muscle because of exercising without any external pressure in the existing methods, but our product gives approx 10 kg external pressure to the pelvic muscle, so even if a beginner is able to apply pressure to pelvic muscle easily and to be skillful in the training course within 2-3 min.
3) Convenient Operation : In case of the existing products, a nurse has to direct the training course by stages. However in case of our product, even if a beginner is able to be skillful in the training course within 2-3 min. It is very convenient for a hospital to operate this product.
Furthermore, it is no need to conduct any follow-up treatment after use, such as sterilization.
4) Possible to use in early stage after surgical operation : There is no need to insert probe into the vagina, so it is possible to use in early state during even if the surgical part is not recovered perfectly.
5) High Effect of Training : As if exercising the arms with 10 kg dumbbells, the effect of training is excellent because approx 10 kg weight is applied directly to the contraction action of pelvic muscle.
6) Securing global key original technology : This is the only product in the world.
- How to Use
An appropriate weight calculated automatically is applied to the pelvic muscle, which helps to perceive the pelvic muscle easily. After that as if containing urine, apply pressure to the pelvic muscle with watching the screen till the red line hits the bar graph of trapezoid(see the left figure).
- Purpose of Use
The use of pelvic muscle is rare at ordinary times. In case of women, injury or weakening of pelvic muscle due to pregnancy and childbirth is one of the causes of Urinary Incontinence and lowering of sexual function. The exercise for pelvic muscle helps the bulk of pelvic muscle to be increased and supports the bladder and the urethra systematically.
Therefore, though the abdominal pressure is high, the pelvic muscle is contracted quickly and powerfully enabling urine not to run out by blocking the descent of the bladder and the urethra.
- Suggestions in Use
- How to Keep and Control after Use
- Specification
|
Classification
|
Item
|
Content
|
|
pelvic muscular force measurement
|
Scope of Measurement
|
0~50 kg
|
|
Precision
|
Within ±5%
|
|
|
abdominal pressure
|
Scope of Measurement
|
0~3kg
|
|
precision
|
Within ±5%
|
|
|
Electrical Features
|
Line Voltage
|
100~240 VAC 50Hz/60Hz
|
|
Max. power consumption
|
300W(max.)
|
|
|
Fuse standardS
|
TIAL - 250V
|
|
|
afety Form
|
1st class BF-type Device
|
|
|
Computer System
|
Min. Requirements
|
Intel Pentium 4 2.0 Ghz (Celeron) or more
OS : MS Window XP or more Available H/W Capacity: 80 GB |
our website: http://kbm33.en.ec21.com/
Similar products in other categories :
Browse: Manufacturer Directory Countries China India Korea Premium Suppliers Community Site Map
About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy
中文 繁體 한국어 日本語 Español Русский Français Deutsch
Hot Products : A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Copyright (c)1997-2013 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese
Business Registry Number: 120-86-03931