<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 0 kv 35 kv transformer]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/0 kv 35 kv transformer.html]]></link><item>
<title><![CDATA[WAYJUN DIN35 Transmitters Price,0-+-10v/0-75mv/0-24v]]></title><link><![CDATA[https://wjsignal8866.en.ec21.com/WAYJUN-DIN35-Transmitters-Price-0--6753149_7285033.html]]></link><description><![CDATA[WAYJUN DIN35 Transmitters Price,0-+-10v/0-75mv/0-24v
DIN Rail Analog Signal Isolated Converters
(TWO IN TWO OUT, Optical Isolation)
Features:
&gt;&gt; Accuracy grade: 0.1/0.2/0.5. Factory calibrated, the u]]></description><pubDate><![CDATA[20250318]]></pubDate></item>
<item>
<title><![CDATA[Glass Cloth Tape]]></title><link><![CDATA[https://citchem.en.ec21.com/Glass-Cloth-Tape--5741528_7290370.html]]></link><description><![CDATA[transformer and others.
Items
Method
Normal
Minimum
Adhesive Type Silicone
Silicone
Substrate
Firberglass Cloth
Substrate Thickness (mil/mm)
ASTM D 1000
4.00 / 0.10
Total Thickness (mil/mm)
ASTM D 10]]></description><pubDate><![CDATA[20250310]]></pubDate></item>
<item>
<title><![CDATA[S11~S13 Series 10 Kv~35 Kv Low-loss Non-excited Voltage Regulating Transformer]]></title><link><![CDATA[https://zcelectric888.en.ec21.com/S11-S13-Series-10-Kv--11987763_11987842.html]]></link><description><![CDATA[S11~S13 Series 10 kV~35 kV Low-loss Non-excited Voltage Regulating Transformer
This product complies with the national standards GB1094-1996 and GB/T6451-2008 for technical parameters and requirement]]></description><pubDate><![CDATA[20240819]]></pubDate></item>
<item>
<title><![CDATA[220kV Three Phase Oil Immersed Transformer]]></title><link><![CDATA[https://eemctransformer.en.ec21.com/220kV-Three-Phase-Oil-Immersed--11977910_11978639.html]]></link><description><![CDATA[kV 
kW 
kW 
% 
% 
% 
% 
m 
M 
M 
1000kg 
125 
225/115/23
35
240
0,1
11
45
28
10,15
6,45
7,43
154
250 
225/115/23
58
380
0,03
11
35
21
12,0
6,45
7650
200
The transformers with
other capacity, voltage ]]></description><pubDate><![CDATA[20240801]]></pubDate></item>
<item>
<title><![CDATA[WSD-YBW Series Prefabricated Substation]]></title><link><![CDATA[https://wisdompe.en.ec21.com/WSD-YBW-Series-Prefabricated-Substation--11000759_11000802.html]]></link><description><![CDATA[transformer and low-voltage distribution equipment according to a certain wiring scheme.
This series of prefabricated substations
are suitable for 24kV, rated frequency 50HZ three-phase AC system. Th]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[Oil Immersed Current Transformer]]></title><link><![CDATA[https://cnmeic68.en.ec21.com/Oil-Immersed-Current-Transformer--10967391_10967416.html]]></link><description><![CDATA[Oil immersed Current
transformer
main parameter of 69kv CT
Rated
current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A
Rated
output capacity of each corresponding ratio:
200/160/150/120/110/8]]></description><pubDate><![CDATA[20230923]]></pubDate></item>
<item>
<title><![CDATA[Combined AC SPD Type 1 and Type 2 Lightning Current Arrester and Surge Arrester]]></title><link><![CDATA[https://yuelong1.en.ec21.com/Combined-AC-SPD-Type-1--11601815_11864427.html]]></link><description><![CDATA[0A to LPZ 2.●Installation at the boundary of zones LPZ1 and LPZ2●Use for the direct lightning protection in Power system, can usage in Transformer low-voltage side.●DIN rail installation.
DIMEN]]></description><pubDate><![CDATA[20231109]]></pubDate></item>
<item>
<title><![CDATA[11kv 200kva Distribution Power Transformer]]></title><link><![CDATA[https://kjwpower21.en.ec21.com/11kv-200kva-Distribution-Power-Transformer--11692084_11692085.html]]></link><description><![CDATA[11kV 200kVA oil immersed distribution transformer . committed to providing kinds of distribution transformers for clients with high quality and competitive price. If you have related needs, weclome t]]></description><pubDate><![CDATA[20230910]]></pubDate></item>
<item>
<title><![CDATA[Outdoor Use Type High Vacuum Transformer Oil Purification Machine,Transformer Oil Purifier Plant]]></title><link><![CDATA[https://aijiezn.en.ec21.com/Outdoor-Use-Type-High-Vacuum--3459584_11286011.html]]></link><description><![CDATA[transformer equipment installation and
maintenance. Purifying insulating oil in 110KV-330KV transformer, also suitable
for high-grade new oil, imported oil deep purifying.
Features: 
1.Used in the el]]></description><pubDate><![CDATA[20220825]]></pubDate></item>
<item>
<title><![CDATA[High Durable Transformer Oil Filtration Plant]]></title><link><![CDATA[https://andyzhang023.en.ec21.com/High-Durable-Transformer-Oil-Filtration--3604099_10375448.html]]></link><description><![CDATA[transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110V substation live line work onsite. Meanwhile, Series ZYD oil purifier can be use]]></description><pubDate><![CDATA[20170426]]></pubDate></item>
<item>
<title><![CDATA[Weather-proof Transformer Oil Purifier, Double Stage Vacuum Transformer Oil Filtration Equipment]]></title><link><![CDATA[https://zhongneng123.en.ec21.com/Weather-proof-Transformer-Oil-Purifier--11519463_11519467.html]]></link><description><![CDATA[00KV electricity. This series may include two types, fixed close type and mobile trailer mounted type, suitable for oil treatment, transformer vacuum oilling and hot oil circulation draying during bi]]></description><pubDate><![CDATA[20220129]]></pubDate></item>
<item>
<title><![CDATA[G10/FR4 Glass Epoxy Sheet]]></title><link><![CDATA[https://laminatedsheet.en.ec21.com/G10-FR4-Glass-Epoxy-Sheet--6244451_6244452.html]]></link><description><![CDATA[0 Mpa
Impact Strength parallel &gt; 37 KJ/m2
Insulation resistance after water dipping ≥5.0×108 Ω
Parallel layer direction breakdown voltage at 90±2 transformer oil ≥35 KV
Yancheng Tiandi Insulat]]></description><pubDate><![CDATA[20220415]]></pubDate></item>
<item>
<title><![CDATA[15KV 200A Loadbreak Elbow Connector]]></title><link><![CDATA[https://enochele.en.ec21.com/15KV-200A-Loadbreak-Elbow-Connector--11808648_11808651.html]]></link><description><![CDATA[The 15KV 200A Loadbreak Elbow Connector produced by ENOCH is a fully-shielded and insulated plug-in termination for connecting underground cable to distribution power system of pad-mound transformer,]]></description><pubDate><![CDATA[20230619]]></pubDate></item>
<item>
<title><![CDATA[Indoor Cast Resin Medium Voltage Current Transformer]]></title><link><![CDATA[https://chinahzsgdq.en.ec21.com/Indoor-Cast-Resin-Medium-Voltage--4986413_6494696.html]]></link><description><![CDATA[Cast Resin Current Transformer (Indoor)Application: for power, current measurement and relay protection in voltage up to 35kV AC 50/60Hz power system and for panel builders.
Technical Data:LDJ5-35Q/3]]></description><pubDate><![CDATA[20131105]]></pubDate></item>
<item>
<title><![CDATA[36-765kv Oil-immersed Current  Transformers]]></title><link><![CDATA[https://qiudanok.en.ec21.com/36-765kv-Oil-immersed-Current--10759095_10759096.html]]></link><description><![CDATA[Oil immersed current transformer (Live tank type, Top head, Top core, Inverted type) 
36kV&amp;hellip;765kV LVB-series 
765kV 550kV 525kV 420kV 362kV 300kV 245kV 170kV 145kV 123kV 72.5kV 52kV 36kV Oil im]]></description><pubDate><![CDATA[20180622]]></pubDate></item>
<item>
<title><![CDATA[Surge Generator]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Surge-Generator--9657760_11802782.html]]></link><description><![CDATA[KV or 6KV Surge Generator SG61000-5
How does a surge generator work?The SG61000-5 surge generator provides a common basis for evaluating the resistance of power cords and internal connectors of diffe]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Transformer Oil Regeneration Purifier for Series ZYD-I]]></title><link><![CDATA[https://hopufiltration.en.ec21.com/Transformer-Oil-Regeneration-Purifier-for--10827141_10827162.html]]></link><description><![CDATA[transformers, it is cost-effective, easy to operate.
Features
1.PH≥5.5
2.Acid≤0.03mgkoH/g
3.Flash point≥145℃
4.Anti-pressure≥60KV
5.Dielectric loss: tgδ（90℃）%≤0.001
6.High vacuum: ]]></description><pubDate><![CDATA[20230901]]></pubDate></item>
<item>
<title><![CDATA[Manufacturer Variable Frequency Series High Voltage AC Resonant Test System]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Manufacturer-Variable-Frequency-Series-High--10544358_10544744.html]]></link><description><![CDATA[kV / 35kV / 110kV /220kv cables, transformers and GIS. The reactor is designed in more than one separately, which not only can meet the test condition requirements for equipments with high voltage an]]></description><pubDate><![CDATA[20170921]]></pubDate></item>
<item>
<title><![CDATA[IEMS Integrated Energy Management Station For Smart Grid Device]]></title><link><![CDATA[https://ttransfo.en.ec21.com/IEMS-Integrated-Energy-Management-Station--10679427_10679433.html]]></link><description><![CDATA[0.4kV, 12kV, and 35kV, with capacity from 100KW to 1260kW.
2. Characteristics 
2.1 Compact design: 
Integrated design, shop pre-assembled, optimized structure, compact arrangement, small floor space,]]></description><pubDate><![CDATA[20180314]]></pubDate></item>
<item>
<title><![CDATA[Grey Color 3000A Clamp On Ct AC Current Probe for Cable Fault Tester]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/Grey-Color-3000A-Clamp-On--10658139_10659333.html]]></link><description><![CDATA[000 A and more. 
Applications 
The Q125B is a high performance clamp on AC Current Probe with excellent transformation and low phase shift. The high quality magnetic core and uniform windings provide]]></description><pubDate><![CDATA[20180509]]></pubDate></item>

</channel>
</rss>