<title><![CDATA[DGA-X NOx, SO2, NH3 Flue Gas Analyzer]]></title><link><![CDATA[https://dxgltd.en.ec21.com/DGA_X_NOx_SO2_NH3--11885117_11885118.html]]></link><description><![CDATA[Drift (2 hours)〈 ± 1% FSRepeatability〈 ± 1% FSLinearity〈 ± 1% FSResponse Time&lt; 5 secondsMeasurement Conditions
Operating Temperature-20 ~ +55 ℃Gas Temperature&lt; +900 °CCommunication
Analog]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[GC112N Lab Analysis Instruments High Performance Gas Chromatograph with Cheap Price]]></title><link><![CDATA[https://smtlabtech.en.ec21.com/GC112N_Lab_Analysis_Instruments_High--11812964_11812965.html]]></link><description><![CDATA[drift
≤ 6× 10-13A
Dynamic range
107
RSD
3% or less
Thermal conductivity detector (TCD)
Sensitivity
5000mV•mL/mg (n-cetane)
Baseline noise
≤ 0.05 mV
Baseline drift
≤ 0.15mV / 30min
Dynamic ra]]></description><pubDate><![CDATA[20230629]]></pubDate></item>
<item>
<title><![CDATA[Exd CH4 LPG CNG Gas Detector Combustible Gas Detection System 4-20mA Output]]></title><link><![CDATA[https://ansion.en.ec21.com/Exd_CH4_LPG_CNG_Gas--11871665_11871666.html]]></link><description><![CDATA[drift, temperature compensation, multi-level calibration
6. Infrared remote control (optional) can realize operation without opening the cover in dangerous places, such as: modify alarm point, addres]]></description><pubDate><![CDATA[20231201]]></pubDate></item>
<item>
<title><![CDATA[Portable Emission Measurement System(PEMS) GASBOARD-9805 Based On UV-DOAS and NDIR]]></title><link><![CDATA[https://ruiyi2021.en.ec21.com/Portable_Emission_Measurement_System_PEMS--11469635_11469749.html]]></link><description><![CDATA[drift (4 hours)
CO:≤±50ppm
CO2:≤±0.10%
NO,NO2:≤5ppm
Span drift (4 hours)
CO: ≤2% of reading or ≤±50ppm, whichever is greater
CO2: ≤2% of reading or ±0.1%, whichever is greater
NO, NO2]]></description><pubDate><![CDATA[20220223]]></pubDate></item>
<item>
<title><![CDATA[F-Sorb 2400CE BET Surface Area Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/F_Sorb_2400CE_BET_Surface--7277219_7276924.html]]></link><description><![CDATA[drift.
3. 
Fully automatic
operation, minimal user involvement and work efficiency be improved.
C. Data
Acquisition and Reduction 
1. 
High precision
data acquisition and signal amplification, high i]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[CH4 H2 Cal CO Gas Analyzer]]></title><link><![CDATA[https://xajunengins.en.ec21.com/CH4_H2_Cal_CO_Gas--10893228_10893229.html]]></link><description><![CDATA[drift
&amp;plusmn;1% /7d
Span drift
&amp;plusmn;1% /7d
Power supply
220V ac , 50Hz &amp;plusmn;5%
Analogue output
Isolated 4-20mA dc output
Data communication
Choice of RS232/RS485
Output range
configuration dep]]></description><pubDate><![CDATA[20190114]]></pubDate></item>