<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - isolators]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/isolators--0927/1/isolators.html]]></link><item>
<title><![CDATA[Wholesale High Voltage Reach 1500VDC Solar Isolator Switch Using in Protection System]]></title><link><![CDATA[https://april0313.en.ec21.com/Wholesale_High_Voltage_Reach_1500VDC--11931299_11974026.html]]></link><description><![CDATA[]]></description><pubDate><![CDATA[20240724]]></pubDate></item>
<item>
<title><![CDATA[I-7520/I-7520a/I-7520r/I-7520ar Isolated RS-232 To RS-422/485 Converter]]></title><link><![CDATA[https://icdam.en.ec21.com/I_7520_I_7520a_I--11795990_11798958.html]]></link><description><![CDATA[isolated RS-422 or RS-485 signal with no need to change any hardware or software. The I-7520AR lets you easily 
build an industrial grade, long-distance communication system using standard PC hardwar]]></description><pubDate><![CDATA[20230530]]></pubDate></item>
<item>
<title><![CDATA[8AI Board 8AI 4-20mA 12bit RS485 Modbus Current Acquisition Optocoupler Isolate]]></title><link><![CDATA[https://nitwoken.en.ec21.com/8AI_Board_8AI_4_20mA--9472913_9475633.html]]></link><description><![CDATA[8AI Board 8AI 4-20mA 12bit RS485 Modbus Current Acquisition optocoupler isolate. 
8AI Board 8AI 4-20mA 12bit RS485 Modbus Current Acquisition optocoupler isolate.]]></description><pubDate><![CDATA[20150419]]></pubDate></item>
<item>
<title><![CDATA[Unitronics OPLC V570]]></title><link><![CDATA[https://automate.en.ec21.com/Unitronics_OPLC_V570--4146634_11917415.html]]></link><description><![CDATA[Remote Access for data acquisition and program download, via Ethernet, GPRS/GSM or landline modem 
• MODBUS protocol support • CANopen and UniCAN support• 2 isolated RS232/RS485 ports 
]]></description><pubDate><![CDATA[20250401]]></pubDate></item>
<item>
<title><![CDATA[RF Generator 1 MHz 50 W for Use in Aesthetic Equipment]]></title><link><![CDATA[https://oemtechspzoo.en.ec21.com/RF_Generator_1_MHz_50--12001597_12050754.html]]></link><description><![CDATA[SELV (interface) circuits are galvanically isolated from high voltage circuits as per IEC 60601-1.
We have also more powerful RFGM module, 300-1500 W with fixed output frequencies RFGM module page.
]]></description><pubDate><![CDATA[20250320]]></pubDate></item>
<item>
<title><![CDATA[ABB TTF200 and TTF300 Model Temperature Transmitter]]></title><link><![CDATA[https://miawang0812.en.ec21.com/ABB_TTF200_and_TTF300_Model--11988808_11988937.html]]></link><description><![CDATA[isolation
Transmitter-controlled graphical indicator
LCD indicator for process value, sensor value and actual value
HART Configurable
TTF300
Wireless option available
Field mount, single-compartment ]]></description><pubDate><![CDATA[20241025]]></pubDate></item>
<item>
<title><![CDATA[Three-Phase Soft Starter for Air Conditioner Rj-Assu380p15 for Three-Phase 380V 15p]]></title><link><![CDATA[https://rjzhuhai01.en.ec21.com/Three_Phase_Soft_Starter_for--10825808_10825844.html]]></link><description><![CDATA[isolating transformer with encapsulating material, which has characteristics of more secure usage and better flame retarding. Two relays on the right are used for output control terminal, among them,]]></description><pubDate><![CDATA[20240929]]></pubDate></item>
<item>
<title><![CDATA[Comprehensive Protection 6000W Tethered Drone Power Station 6000w Output Power]]></title><link><![CDATA[https://rosefinchtech.en.ec21.com/Comprehensive_Protection_6000W_Tethered_Drone--11840851_12003779.html]]></link><description><![CDATA[Isolation voltage≥3000V(Vin-Vout),1min,Current leakage 5mA,no breakdown,flying arc and corona phenomenaInstallation methodPre-mounted lugs, screwed inHeat dissipationExternal fan for active cooling]]></description><pubDate><![CDATA[20240912]]></pubDate></item>
<item>
<title><![CDATA[General Electric IS400JGPAG1ACD Card]]></title><link><![CDATA[https://toptengsmiling.en.ec21.com/General_Electric_IS400JGPAG1ACD_Card--11992771_11992772.html]]></link><description><![CDATA[Isolated Contact In: 16 discrete inputs
IS220PDIOH1A IS220PDIOH1B Discrete I/O: 24 Contact In and 12 type C mechanical relays
IS220PDOAH1A IS220PDOAH1B Contact Out: 12 relays with status feedback
IS2]]></description><pubDate><![CDATA[20240906]]></pubDate></item>
<item>
<title><![CDATA[New Arrival JIKONG Bms JK-PB1A16S10P JK-PB1A16S15P JK-PB2A16S15P JK-PB2A16S20P Active Balance Smart]]></title><link><![CDATA[https://23445bella.en.ec21.com/New_Arrival_JIKONG_Bms_JK--11964892_11965646.html]]></link><description><![CDATA[Isolated power circuit Short circuit protection 4-way temperature detection protection MOS temperature detection protectionFor Europe customer if you want DDP or DPD shipping way please contact with ]]></description><pubDate><![CDATA[20240709]]></pubDate></item>
<item>
<title><![CDATA[TTL ANSI TYPE-2 C12.18 Standard IR Infrared Optical Probe for Smart Meter Kwh Meters Data Reading]]></title><link><![CDATA[https://myirda.en.ec21.com/TTL_ANSI_TYPE_2_C12.18--11953831_11954112.html]]></link><description><![CDATA[DESCRIPTION
MY021-D TTL to IR ANSI Type-2converter /optical probe utilize an infra-red LED technology to provide a galvanically isolated, bi-directional communications link between computers and ANSI]]></description><pubDate><![CDATA[20240619]]></pubDate></item>
<item>
<title><![CDATA[AMS Trex Device Communicator - HART+Foundation Fieldbus]]></title><link><![CDATA[https://19870710superior.en.ec21.com/AMS_Trex_Device_Communicator_HART--11949899_11949900.html]]></link><description><![CDATA[isolates it from the rest of the system, helping pinpoint installation issues, including power supply, wiring, I/O cards, or configuration.Power the loop functionality also allows device configuratio]]></description><pubDate><![CDATA[20240611]]></pubDate></item>
<item>
<title><![CDATA[Yokogawa  CENTUM-CS XL]]></title><link><![CDATA[https://jiangstar.en.ec21.com/Yokogawa_CENTUM_CS_XL--9022887_9290701.html]]></link><description><![CDATA[Isolated） 
AAI543 ,AAI543-S00,AAI543-H00 ,AAI543-H03，AAI543-H00/K4A00Analog Output Module （4 to 20 mA, 16-Channel, Isolated） 
AAT141,AAT141-S00 TC/mV Input Module （16-Channel, Isolated） 
]]></description><pubDate><![CDATA[20240517]]></pubDate></item>
<item>
<title><![CDATA[CMC-MX 7.5KW-220KWBuilt-in Bypass Soft Starter]]></title><link><![CDATA[https://xichi2015.en.ec21.com/CMC_MX_7.5KW_220KWBuilt_in--9554986_9565934.html]]></link><description><![CDATA[isolated using photoelectricity and different noise-proof levels to fit the application in special industry.
Simple adjustment 
Control system provides wide scope of application and simple adjustment]]></description><pubDate><![CDATA[20220406]]></pubDate></item>
<item>
<title><![CDATA[Generator Excitation System]]></title><link><![CDATA[https://hestelectrical.en.ec21.com/Generator_Excitation_System--9564982_9565031.html]]></link><description><![CDATA[Isolating RS-232C/RS-485 communication interfaces, and supporting standard ModBusRTU communication protocol 
18. Man-machine interfaces (HMI) of several specifications for choice, printer and micro p]]></description><pubDate><![CDATA[20150625]]></pubDate></item>
<item>
<title><![CDATA[R-8017B  8-channel Analog Input Module with Modbus]]></title><link><![CDATA[https://jane2015gemotech.en.ec21.com/R_8017B_8_channel_Analog--10081766_11252571.html]]></link><description><![CDATA[±150mV, ±500mV, ±1V, ±5V, ±10V, ±20mA, 4-20mA
- Isolated Voltage: 3000VDC
- Over Voltage protection: ±35V
- Sampling: 10times/S
- Input Impedance: 20M Ohms
- Supports Modbus/RTU Protocol
]]></description><pubDate><![CDATA[20200907]]></pubDate></item>
<item>
<title><![CDATA[26.5GHz40GHz  Two Channels Power Divider]]></title><link><![CDATA[https://hyan001carmen.en.ec21.com/26.5GHz40GHz_Two_Channels_Power_Divider--11080913_11080915.html]]></link><description><![CDATA[Isolation：
typical≥15.5dB
，ultimate≥
15dB；
8) 
Max. input power：
30W（used as an allocator
）；
9) 
Temperature range：
-55℃～+85
℃。
2.3 Input /
Output Interface 
1) 
RF
interf]]></description><pubDate><![CDATA[20210624]]></pubDate></item>
<item>
<title><![CDATA[PV Switch-disconnector Power Distribution Module]]></title><link><![CDATA[https://cnlonq.en.ec21.com/PV_Switch_disconnector_Power_Distribution--11846228_11846231.html]]></link><description><![CDATA[isolation switch is equipped with an air valve to facilitate air circulation and temperature reduction.1.CNLonQcom is a professional producer specialising in the creation of PV Switch-disconnector 15]]></description><pubDate><![CDATA[20230920]]></pubDate></item>
<item>
<title><![CDATA[Surge Generator]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Surge_Generator--9657760_11802782.html]]></link><description><![CDATA[Isolution Transformerfor EUT (Optional)LISUN ITEU-SP4K (220V Single phase) or ITUS-SP2K (110V)LISUN ITEU-TP10K or ITUS-TP5KOver 10KV Surge Generator SG61000-5H
Remark: 10KV Surge Generator, 12KV Surg]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[PSP Series High Precision Programmable Switching Mode DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/PSP_Series_High_Precision_Programmable--9605857_9605933.html]]></link><description><![CDATA[isolated / non-isolated) 
Programmable, different communication port: RS232, RS485, CAN, USB, GPIB, LAN etc. 
Master-slave control
Support multi-units parallel connection working, total power could b]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[PCBAs Circuit Boards for 600W Portable Power Supply Assembly Semi-finished Goods Not BMS]]></title><link><![CDATA[https://zhangfei1electronics.en.ec21.com/PCBAs_Circuit_Boards_for_600W--11875306_11875678.html]]></link><description><![CDATA[isolated communication interface.
8. Interfaces
600W Inverter Interfaces:
BAT+ 2. BAT- 3. AC220V 4. Front Stage Temperature Sensor 5. Fan
Power Control 7. 485 Communication 8. Rear Stage Temperature ]]></description><pubDate><![CDATA[20231222]]></pubDate></item>
<item>
<title><![CDATA[GF102 Portable Single Phase Energy Meter Test Bench]]></title><link><![CDATA[https://gfuvegroup.en.ec21.com/GF102_Portable_Single_Phase_Energy--11546876_11547642.html]]></link><description><![CDATA[This product is portable design,used for laboratory and on-site to check watt-hour meter error.
Reference standard and power source integrated.
ACCURACT CLASS:0.02
3 channel voltage isolation.
0-120A]]></description><pubDate><![CDATA[20230223]]></pubDate></item>
<item>
<title><![CDATA[Medium Voltage Split Core Current Transformer]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/Medium_Voltage_Split_Core_Current--10658139_10659177.html]]></link><description><![CDATA[isolate or transform voltage or current levels. The most common usage of current transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating second]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[4G Wireless SMS Remote Monitoring Control RTU Gateway Supports Modbus MQTT]]></title><link><![CDATA[https://kingpigeoniot20.en.ec21.com/4G_Wireless_SMS_Remote_Monitoring--11855887_11855889.html]]></link><description><![CDATA[can communicate directly with the server, cloud platform or SCADA.
Metal case with IP30 protection grade, safely isolated from inner system, especially suitable for industrial control application.
]]></description><pubDate><![CDATA[20231018]]></pubDate></item>
<item>
<title><![CDATA[1751-6091 Woodward VDC Power Supply]]></title><link><![CDATA[https://modal.en.ec21.com/1751_6091_Woodward_VDC_Power--11854992_11855037.html]]></link><description><![CDATA[Temperature sensors
- Solenoids
- Valve actuators 
All I/O modules are optically isolated to the bus, ensuring safe and trouble-free operation. All I/O modules are also software configurable.
T8311]]></description><pubDate><![CDATA[20240116]]></pubDate></item>
<item>
<title><![CDATA[WSD-ZW32-24D Outdoor AC High Voltage Vacuum Circuit Breaker]]></title><link><![CDATA[https://wisdompe.en.ec21.com/WSD_ZW32_24D_Outdoor_AC--11000759_11000804.html]]></link><description><![CDATA[isolated.
8. Operating mechanism can choose permanent magnet structure, which is sensitive to action and can cut off short-circuit current quickly. (Matching)
Ⅳ.Standard conditions of use:
1. Ambie]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[LSDOM01 Digital Output  Module Mitsubishi]]></title><link><![CDATA[https://adatronix.en.ec21.com/LSDOM01_Digital_Output_Module_Mitsubishi--11339795_11469325.html]]></link><description><![CDATA[LSDOM01 Digital Output Module Mitsubishi
＊Number of outputs : 8 (Channel individual isolation)
＊Contact : Dry / A contact(Normally Open)
＊Contact method : Open drain
＊Module ambient temperatu]]></description><pubDate><![CDATA[20211103]]></pubDate></item>
<item>
<title><![CDATA[Double Serial Device RS232 RS485 RS422 Ethernet Server Modbus Multi-host Polling]]></title><link><![CDATA[https://gpthink.en.ec21.com/Double_Serial_Device_RS232_RS485--11896477_11897229.html]]></link><description><![CDATA[isolation）auto MDI/MDI-X Ethernet interface, interface RJ45
Serial Standard
RS-232, RS-485, RS-422
RS-485, RS-422
Serial Connector
4×RJ45
4×4Pin 3.81mm terminals
Indicator light
PWR light RUN
Pow]]></description><pubDate><![CDATA[20240204]]></pubDate></item>
<item>
<title><![CDATA[Acrel Ahkc-e Series Hall DC Voltage Transducer]]></title><link><![CDATA[https://acrel1.en.ec21.com/Acrel_Ahkc_e_Series_Hall--11836609_11873923.html]]></link><description><![CDATA[Isolation Voltage
3.5kV/50Hz/1min
Operating Temperature
-40°C~85°C
Storage Temperature
-40°C~85°C
Consumption
≤0.5W
Now the price of dc motor with hall sensor
is reasonable, if you have needs, ]]></description><pubDate><![CDATA[20231208]]></pubDate></item>
<item>
<title><![CDATA[ABB DIO-400	PHBDIO40010000	Digital I/O Module - Harmony Block I/O]]></title><link><![CDATA[https://britneyjiang.en.ec21.com/ABB_DIO_400_PHBDIO40010000_Digital--11819133_11819783.html]]></link><description><![CDATA[isolated Digital Inputs; 24 VDC, 48 VDC, 125 VDC, 120 VAC, and 240 VAC and eight (8) Isolated Digital Outputs; 24 VDC at250mA and 48 VDC at 125 mA.
About Moore
Company profile 
Founded in 2011, Moore]]></description><pubDate><![CDATA[20230714]]></pubDate></item>
<item>
<title><![CDATA[HIigh Power 3000W Inverter Circuit Board Supplier]]></title><link><![CDATA[https://hisolar12.en.ec21.com/HIigh_Power_3000W_Inverter_Circuit--11601977_11750752.html]]></link><description><![CDATA[isolated systemSuperior Endurance Performance: Durable construction and quality material stands up to harsh environments and all season, ideal for use on road, at campsites, remote job sites or anywh]]></description><pubDate><![CDATA[20230317]]></pubDate></item>
<item>
<title><![CDATA[Eaton 93PR Online Modular UPS]]></title><link><![CDATA[https://visenchups.en.ec21.com/Eaton_93PR_Online_Modular_UPS--11890241_11890242.html]]></link><description><![CDATA[isolation (INPUT/OUTPUT/OUTPUT/MBS)Predict Plus*, key components life span monitoring Easy management Red light bars showing alerts on system. Yellow light bars indicate battery and bypass status. In]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Power Supply-60Watts]]></title><link><![CDATA[https://gofern.en.ec21.com/Power_Supply_60Watts--2126323_2126372.html]]></link><description><![CDATA[Isolation resistance:50M&amp;Omega; Working time:0-45?, 20%-90%RH Cooling by fee air convection Dimension:145x46 (mm) Single output: 5V 12A 12V 5A 15V 4A 24V 2.5A Multiple output: +24V 2A/+5V 1A
]]></description><pubDate><![CDATA[20090718]]></pubDate></item>
<item>
<title><![CDATA[Explosion-proof Distribution Panel MAMX-02/03]]></title><link><![CDATA[https://mamex68.en.ec21.com/Explosion_proof_Distribution_Panel_MAMX--11618529_11618535.html]]></link><description><![CDATA[isolate them from hazardous environments. The third layer of protection, intrinsically safe, ensures that ignition does not occur by limiting the energy. This protection mechanism ensures that the co]]></description><pubDate><![CDATA[20220810]]></pubDate></item>
<item>
<title><![CDATA[Polymer Earth Bushing]]></title><link><![CDATA[https://tytec.en.ec21.com/Polymer_Earth_Bushing--11853501_11853589.html]]></link><description><![CDATA[Usage· An isolated protection device of the lowtension side terminal of transformer using for power Polymer insulating material maintaining insulation and output terminal protectionFeatures· It is ]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[130MVA Energy Storage High Power Test System for Transformer Routine Test Short Circuit Test]]></title><link><![CDATA[https://shjiuzhi.en.ec21.com/130MVA_Energy_Storage_High_Power--2783495_11883722.html]]></link><description><![CDATA[Isolation Switch, Circuit Breaker – IEC62271
◆ Short-time Withstand Current Test &amp; Peak Withstand Current Test for Box Type Substation Main Circuit and Grounding Circuit (American Model &amp; Europea]]></description><pubDate><![CDATA[20240304]]></pubDate></item>
<item>
<title><![CDATA[Modbus MQTT 2 Ethernet Ports Module for Remote Data Monitoring]]></title><link><![CDATA[https://billot.en.ec21.com/Modbus_MQTT_2_Ethernet_Ports--11868855_11868867.html]]></link><description><![CDATA[The M series Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microp]]></description><pubDate><![CDATA[20231121]]></pubDate></item>
<item>
<title><![CDATA[50Hz / 60Hz Tethered Drone Station System Automatic Voltage Compensation]]></title><link><![CDATA[https://dronetethered.en.ec21.com/50Hz_60Hz_Tethered_Drone_Station--11869261_11869262.html]]></link><description><![CDATA[PRODUCT DESCRIPTIONTethered Drone Station: Automatic Voltage Compensation, Isolation Design, One-Click Power Start
size60.5x45x48cmweight50kginput380V AC ±10% 50Hz/60Hzoutput750V DC / 10KWheight110m]]></description><pubDate><![CDATA[20231122]]></pubDate></item>
<item>
<title><![CDATA[LED Chip Counter]]></title><link><![CDATA[https://wisys.en.ec21.com/LED_Chip_Counter--5384672_5393048.html]]></link><description><![CDATA[SET
In/Out
Channel
32ch/32ch(Photo Isolated DIO Board)
Camera
1 SET
Line Scan
8000 pixel Mono type(Resolution)
Light
1 SET
Light Source
Coaxial Type LED
Light Controller
Remote Control Type
]]></description><pubDate><![CDATA[20130312]]></pubDate></item>
<item>
<title><![CDATA[Fisher Dcs]]></title><link><![CDATA[https://spring95000.en.ec21.com/Fisher_Dcs--5508780_5508841.html]]></link><description><![CDATA[ISOL ANALG 43B5312X012-9 4 15 CL6872X1-A2 RED ANALG OUT CSA 41B7288X032 Rev.H 6 16 CL7652X1-A2 DUAL CIA P8.0 41B1841X022 Rev.F 2 17 CL7652X1-A2 DUAL CIA P8.1 41B184X032 Rev.G 1 18 CL7661X1-BA1 MPU/ME]]></description><pubDate><![CDATA[20110605]]></pubDate></item>
<item>
<title><![CDATA[Plantguard P8110B P8151B P8403 P8431 P8451 P8461 P8471 P8448]]></title><link><![CDATA[https://bruseguo.en.ec21.com/Plantguard_P8110B_P8151B_P8403_P8431--7567727_7567797.html]]></link><description><![CDATA[Isolated Analogue Input
P8448 Zone Interface
P8449 24V dc Valve Monitor
P8451 24V dc Digital Output
P8461 24/48V dc Digital Output
P8471 120V dc Digital Output Module
P8472 120V info at oilwaterfilte]]></description><pubDate><![CDATA[20230129]]></pubDate></item>
<item>
<title><![CDATA[PLC Analog FATEK FBS-16EAT]]></title><link><![CDATA[https://autochd.en.ec21.com/PLC_Analog_FATEK_FBS_16EAT--7932608_8004512.html]]></link><description><![CDATA[isolation 4 ports RS485 hub, with ACT, COLLISION indicators
Wiring mechanism: 7,62mm European terminal block
if need following series Fatek Plc also welcome to contact with us
FBs-10MA,FBs-14MA, FBs-]]></description><pubDate><![CDATA[20130513]]></pubDate></item>
<item>
<title><![CDATA[JT6331A DC Electronic Load]]></title><link><![CDATA[https://jartul650413abcd.en.ec21.com/JT6331A_DC_Electronic_Load--9521240_9571275.html]]></link><description><![CDATA[isolated RS232 serial port.
5V/200mA power output, fit for the interconnection of equipments with different interfaces.
TRIG_IN、RI、DFI、TRIG_OUT four high-speed isolated I/O, supporting multi lo]]></description><pubDate><![CDATA[20161222]]></pubDate></item>

</channel>
</rss>