<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - temperature measurement]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/temperature_measurement--2673/1/temperature measurement.html]]></link><item>
<title><![CDATA[Vibrating Wire Spot Weldable Strain Gauge]]></title><link><![CDATA[https://geovan.en.ec21.com/Vibrating_Wire_Spot_Weldable_Strain--12059222_12059258.html]]></link><description><![CDATA[Wire
Standard Range
3,000 microstrains
Sensitivity
1.0 microstrain
Accuracy
less than ±0.25% F.S.
Nonlinearity
less than ±0.25% F.S.
Temperature Range
-20°C to +80°C
Gage Length
50.8mm
]]></description><pubDate><![CDATA[20250828]]></pubDate></item>
<item>
<title><![CDATA[High Precision Film Fined Resistors]]></title><link><![CDATA[https://xy-resistor.en.ec21.com/High_Precision_Film_Fined_Resistors--12069996_12070002.html]]></link><description><![CDATA[measurements of parameters such as temperature, humidity, and air quality. Their stability and precision are vital for reliable data collection in environmental studies.
Semiconductor Testing In semi]]></description><pubDate><![CDATA[20260413]]></pubDate></item>
<item>
<title><![CDATA[UNISTREAM Built-in PLC]]></title><link><![CDATA[https://automate.en.ec21.com/UNISTREAM_Built_in_PLC--4146634_11921121.html]]></link><description><![CDATA[temperature, and weight measurement
•Expand locally: up to 2048 I/Os
Expand remotely: via UniStream Ethernet-based I/O
Auto-tune PID, up to 64 independent loops
• Recipes &amp; data logging via data ]]></description><pubDate><![CDATA[20250401]]></pubDate></item>
<item>
<title><![CDATA[Custom Medical Laser Aluminum High Performance Skived Fin Heatsinks]]></title><link><![CDATA[https://bythermal.en.ec21.com/Custom_Medical_Laser_Aluminum_High--12049106_12050194.html]]></link><description><![CDATA[temperature measurement,
and heat flux measurement to accurately assess its performance. Additionally,
we conduct CFD simulation for heat sink design optimization, ensuring that our
products meet the]]></description><pubDate><![CDATA[20250318]]></pubDate></item>
<item>
<title><![CDATA[Pizza Cone Gas Oven]]></title><link><![CDATA[https://huspa.en.ec21.com/Pizza_Cone_Gas_Oven--10919481_10919583.html]]></link><description><![CDATA[temperature and gas control. Fully safety measures in accordance to european and us standards as ce and ul certification. Outer body is metal with powder paint and inner structure is stainless steel.]]></description><pubDate><![CDATA[20250213]]></pubDate></item>
<item>
<title><![CDATA[Batteries  Automatic Liquid Injection Line]]></title><link><![CDATA[https://sidasi999.en.ec21.com/Batteries_Automatic_Liquid_Injection_Line--9456505_9456510.html]]></link><description><![CDATA[Measurement range：4Kg，Precision±0.1g。
Standing box
3 sets of vacuum standing system
Outline
5500(L)*700(W)*2000mm(H)
3, the environmental requirements
3.1 ambient temperature: decided by party]]></description><pubDate><![CDATA[20241105]]></pubDate></item>
<item>
<title><![CDATA[Stainless Steel Hardening and Tempering Furnace]]></title><link><![CDATA[https://inductionheater.en.ec21.com/Stainless_Steel_Hardening_and_Tempering--9778587_9793651.html]]></link><description><![CDATA[measuring quenching temperature and tempering temperature).Besides,the tension meter will check the slab tension.
3.Console is the master control station of the slab induction heating furnace,control]]></description><pubDate><![CDATA[20240927]]></pubDate></item>
<item>
<title><![CDATA[Vacuum Graphitization Furnace]]></title><link><![CDATA[https://und24.en.ec21.com/Vacuum_Graphitization_Furnace--12009016_12009022.html]]></link><description><![CDATA[temperature control system is adopted to complete the temperature measurement and control process automatically and accurately. The system can heat up according to the given heating curve, and can st]]></description><pubDate><![CDATA[20240924]]></pubDate></item>
<item>
<title><![CDATA[Gf6018a  Clamp Type Multimeter Calibrator]]></title><link><![CDATA[https://gfuvegroup.en.ec21.com/Gf6018a_Clamp_Type_Multimeter_Calibrator--11546876_11999049.html]]></link><description><![CDATA[Measurement Category300 V CAT III, 600 V CAT IIDegree of protectionIP20Declaration of conformityCE, CNAS certifiedMechanical parametersDimension (L×W×H) (mm)440x360x160Weight (kg)12Environmental co]]></description><pubDate><![CDATA[20240905]]></pubDate></item>
<item>
<title><![CDATA[Festo Servo Motor EMMT-AS-60-S-LS-RMB 5242199 in Stock]]></title><link><![CDATA[https://cwgreentech.en.ec21.com/Festo_Servo_Motor_EMMT_AS--11988971_11988974.html]]></link><description><![CDATA[temperature
-15 °C ... 40 °C
Note on ambient temperature
Up to 80°C with derating of -1.5% per degree Celsius
Max. installation height
4000 m
Note on max. installation height
As of 1,000 m: only w]]></description><pubDate><![CDATA[20240823]]></pubDate></item>
<item>
<title><![CDATA[Telecommunication Communication Cabinet Assembly]]></title><link><![CDATA[https://acesz.en.ec21.com/Telecommunication_Communication_Cabinet_Assembly--11987964_11987974.html]]></link><description><![CDATA[temperature.
EMI shielding: Employing shielding materials and techniques to minimize interference.
Quality control: Adhering to strict quality control measures throughout the assembly process.
The co]]></description><pubDate><![CDATA[20240819]]></pubDate></item>
<item>
<title><![CDATA[3 Axis Shaker Table]]></title><link><![CDATA[https://annie9311.en.ec21.com/3_Axis_Shaker_Table--11982949_11982966.html]]></link><description><![CDATA[JOEO multi axis shaker table technology is at the forefront of vibration test and measurement solutions on the market today, providing end users with accurate and convenient test results with the pot]]></description><pubDate><![CDATA[20240809]]></pubDate></item>
<item>
<title><![CDATA[Peek Film Forming Machine| Lab Twin-screw Extrusion and Casting Machine]]></title><link><![CDATA[https://potopyangliu.en.ec21.com/Peek_Film_Forming_Machine_Lab--11956821_11958149.html]]></link><description><![CDATA[measurement and analysis system. The test material is first melted and homogenized by a precision twin-screw extruder, and then sent to the casting die at a constant speed by a melt pump. It is forme]]></description><pubDate><![CDATA[20240627]]></pubDate></item>
<item>
<title><![CDATA[Horizontal Side Loading S1 Spark Plasma Sintering System]]></title><link><![CDATA[https://haoyuefurnace.en.ec21.com/Horizontal_Side_Loading_S1_Spark--11953323_11953324.html]]></link><description><![CDATA[Temperature Control and Measurement
PLC program temperature control
≤1000℃ with K-type thermal couple
＞1000℃ with infrared thermometer
Gases
High-purity argon or high-purity nitrogen, inflati]]></description><pubDate><![CDATA[20240618]]></pubDate></item>
<item>
<title><![CDATA[AMPRO Plus - ANALYZER SET INCLUDING O2/ CO/ NO and CO2*1 with IR PRINTER]]></title><link><![CDATA[https://mrulab.en.ec21.com/AMPRO_Plus_ANALYZER_SET_INCLUDING--11523326_11951086.html]]></link><description><![CDATA[measured CO2 (OPTION 64618 or 65648)
Large fuel type list + user definable fuel types
Differential Temperature Measurement
Differential Pressure Measurement and Draft Measurement
Modern, slim line en]]></description><pubDate><![CDATA[20240613]]></pubDate></item>
<item>
<title><![CDATA[Hepa Filter PU Dosing Gluing Machine]]></title><link><![CDATA[https://xd5358840.en.ec21.com/Hepa_Filter_PU_Dosing_Gluing--6307152_10814791.html]]></link><description><![CDATA[220V 50Hz/60Hz
Power requirement
3.55KW
Air pressure requirement
4.5-8KG
Machine Dimension
1500(L)*1200(W)*1500(H)mm
Weight
approx 260 KG
Work environment
Humidity: 20%~98%RH; Temperature: 0~+40°c
]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[AWGAGE-200 Metal Film Metrology]]></title><link><![CDATA[https://allwin21.en.ec21.com/AWGAGE_200_Metal_Film_Metrology--9763377_9763394.html]]></link><description><![CDATA[temperature should be close to 23° C for the greatest measurement accuracy.
Avoid environments with high concentrations of particulates, especially abrasives such as glass and silicon dust.
Power : ]]></description><pubDate><![CDATA[20240514]]></pubDate></item>
<item>
<title><![CDATA[New Hilti POS180 Robotic 3 Total Station with POC200 Data Collector]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Hilti_POS180_Robotic_3--11927627_11927702.html]]></link><description><![CDATA[Product Description 
HILTI POS 180 KEY TECHNICAL DATA:Angle measurement accuracy (DIN 18723): 3 “Magnification: 31 xDistance measurement accuracy: ±2 mm + 2 ppmFEATURES:Measures distances to surfa]]></description><pubDate><![CDATA[20240423]]></pubDate></item>
<item>
<title><![CDATA[Trimble 5600 Total Station]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Trimble_5600_Total_Station--11329183_11842790.html]]></link><description><![CDATA[temperature:-20°C to +50°C (-5°F to +122°F)Data input/output:RS-232C Two-way communicationBatteries:–Central unit:–External:rechargeable NiMH battery 12V, 1.6 Ahrechargeable NiMH battery 12V,]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Facerom 1100C Atmosphere Tube Furnace]]></title><link><![CDATA[https://facerom.en.ec21.com/Facerom_1100C_Atmosphere_Tube_Furnace--11824134_11824205.html]]></link><description><![CDATA[temperature RT～1000℃.
2.The diameter of furnace tube is 90mm～250mm.
3. The number of temperature zones is 3～6 optional.
4. The number of furnace tube 1～4 optional.
5. Programmable temperatu]]></description><pubDate><![CDATA[20230724]]></pubDate></item>
<item>
<title><![CDATA[Fine Wire Drawing Machine]]></title><link><![CDATA[https://fastenersmachine.en.ec21.com/Fine_Wire_Drawing_Machine--11880290_11880294.html]]></link><description><![CDATA[temperature and then cooling it slowly to relieve stresses and enhance the material&apos;s ductility, allowing for further drawing.
4. Constant Monitoring and Control: Fine wire drawing machines often com]]></description><pubDate><![CDATA[20231227]]></pubDate></item>
<item>
<title><![CDATA[Used Leveling Machine for Sale]]></title><link><![CDATA[https://ezhonggroup.en.ec21.com/Used_Leveling_Machine_for_Sale--11511703_11511755.html]]></link><description><![CDATA[temperature, automatically bite the plate and feed, and has the functions of overload protection and AGC bounce compensation.
Online measurement technology of force and energy parameters: Online four]]></description><pubDate><![CDATA[20220117]]></pubDate></item>
<item>
<title><![CDATA[Complete Set of Granular Activated Carbon Regeneration Equipment Waste Activated Carbon Recovery Equ]]></title><link><![CDATA[https://walton356.en.ec21.com/Complete_Set_of_Granular_Activated--11859298_11858650.html]]></link><description><![CDATA[Temperature uniformity: ≤±10 Temperature measurement: The temperature range of infrared optical temperature measurement is 800~2400 or 0~2400; the temperature measurement accuracy is 0.2~0.75%.
5.]]></description><pubDate><![CDATA[20231025]]></pubDate></item>
<item>
<title><![CDATA[Lrf Ladle Refining Furnace]]></title><link><![CDATA[https://chnzb.en.ec21.com/Lrf_Ladle_Refining_Furnace--11858115_11858120.html]]></link><description><![CDATA[temperature measurement and sampling technology;
The technology of adding scrap steel to refining furnace;
Argon blowing automatic control technology;
LF one touch steelmaking technology.
We provide ]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Linear Motion Lead Screws]]></title><link><![CDATA[https://vxolinearmotion.en.ec21.com/Linear_Motion_Lead_Screws--11741589_11741590.html]]></link><description><![CDATA[temperature. These key process variables are precisely monitored to ensure the highest level of lead accuracy.
Precision Linear Motion Lead Screws Application
Linear motion lead screws are often used]]></description><pubDate><![CDATA[20230306]]></pubDate></item>
<item>
<title><![CDATA[Jida Medtech Heat Treatment Tube Vacuum Furnace for Endo NiTi File]]></title><link><![CDATA[https://jidamedtech.en.ec21.com/Jida_Medtech_Heat_Treatment_Tube--11908441_11909539.html]]></link><description><![CDATA[measures are implemented throughout the manufacturing process to ensure that each endodontic file meets industry standards and specifications.By carefully controlling the temperature during the heat ]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[Bushing/Sleeve]]></title><link><![CDATA[https://hhcprecision.en.ec21.com/Bushing_Sleeve--11858667_11882709.html]]></link><description><![CDATA[measurements may also be performed using tools like profilometers.
Tolerance Verification: Bushings/sleeves have specific tolerances that define acceptable variations in dimensions. Quality control p]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Packaging Machine Spare Parts]]></title><link><![CDATA[https://goleadmachine.en.ec21.com/Packaging_Machine_Spare_Parts--11905532_11905538.html]]></link><description><![CDATA[Temperature Controllers for regulating temperature, Extruder Filters for filtering impurities, Thermocouples for temperature measurement, Speed Controllers for adjusting machine speed, Photoelectric ]]></description><pubDate><![CDATA[20240223]]></pubDate></item>
<item>
<title><![CDATA[Industrial Induction Heater for Sale]]></title><link><![CDATA[https://tyinduction.en.ec21.com/Industrial_Induction_Heater_for_Sale--11686230_11822644.html]]></link><description><![CDATA[temperature monitoring and control features to ensure precise and consistent heating. Temperature sensors, such as thermocouples or infrared cameras, are used to measure the temperature of the workpi]]></description><pubDate><![CDATA[20240314]]></pubDate></item>
<item>
<title><![CDATA[Brass CNC Precision Mechanical Parts Turning Machining]]></title><link><![CDATA[https://szxhcnc.en.ec21.com/Brass_CNC_Precision_Mechanical_Parts--11778367_11778375.html]]></link><description><![CDATA[measurement; Rapid Prototyping and End-Use Production.
Custom Materials &amp; Finishes50+ Metals and Plastics, 10+ Surface Finishes; Smooth Surface and Strict Tolerance, Custom Material and Surface Treat]]></description><pubDate><![CDATA[20230428]]></pubDate></item>
<item>
<title><![CDATA[DRC-D51K CNC Vertical Ring Rolling Machine]]></title><link><![CDATA[https://youli798.en.ec21.com/DRC_D51K_CNC_Vertical_Ring--11873476_11873477.html]]></link><description><![CDATA[temperature change on the feeding speed, easy to accurately control the feeding movement and increase the stability.
The control system is mainly composed of PLC, touch screen, servo proportional val]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[Smooth Aluminum Induction Melting Furnace System Power Saving]]></title><link><![CDATA[https://meltfurnacescom.en.ec21.com/Smooth_Aluminum_Induction_Melting_Furnace--11874987_11874988.html]]></link><description><![CDATA[measures such as hydraulic lock, power supply cabinet door interlock, grounding protection, a furnace drop-roof hood, molten iron leakage detector, temperature and water leakage protection and resin-]]></description><pubDate><![CDATA[20231212]]></pubDate></item>
<item>
<title><![CDATA[Mini Mirror Scale 2012B]]></title><link><![CDATA[https://haoyuscale.en.ec21.com/Mini_Mirror_Scale_2012B--11637885_11637900.html]]></link><description><![CDATA[Small size, easy to store, smart features for smart users, Body weight measurement readings should be hassle free, so your scale has Auto-On &amp; Auto-Off sensing technology to save battery life.
Specif]]></description><pubDate><![CDATA[20220913]]></pubDate></item>
<item>
<title><![CDATA[Electric Silicon Carbide Heating Element Rod for Industrial Electric Furnace]]></title><link><![CDATA[https://2454652174lq.en.ec21.com/Electric_Silicon_Carbide_Heating_Element--11826720_11830148.html]]></link><description><![CDATA[temperature electric heating element made of green high-purity hexagonal silicon carbide as the main raw material, processed into embryo, silicified at high temperature and recrystallized at 2200 ℃]]></description><pubDate><![CDATA[20230805]]></pubDate></item>
<item>
<title><![CDATA[Green Plain Gauge Glass]]></title><link><![CDATA[https://aohonggaugeglass.en.ec21.com/Green_Plain_Gauge_Glass--11850290_11850301.html]]></link><description><![CDATA[temperature and pressure changes, enhancing its suitability for demanding applications. Its unique green glaze enhances visibility and reading accuracy, improving overall operational efficiency.
Plea]]></description><pubDate><![CDATA[20231004]]></pubDate></item>
<item>
<title><![CDATA[Metal Casting Foundry Resin Sand Reclamation Recycling System Molding Processing Foundry Equipment]]></title><link><![CDATA[https://qdhhxsjx.en.ec21.com/Metal_Casting_Foundry_Resin_Sand--11886340_11886325.html]]></link><description><![CDATA[measurement is accurate, the mixing period is short and the loss of first and last round sand is less. The doublearm of machine rotates flexibly and the available working area is large. The open type]]></description><pubDate><![CDATA[20240110]]></pubDate></item>
<item>
<title><![CDATA[Chemical Etching Molybdenum or Molybdenum Copper]]></title><link><![CDATA[https://wetetching.en.ec21.com/Chemical_Etching_Molybdenum_or_Molybdenum--11869908_11869915.html]]></link><description><![CDATA[temperatures to increase its effectiveness. However, it’s essential to handle Sodium Hydroxide with care as it is caustic and can cause skin and eye irritation. Appropriate safety measures, includi]]></description><pubDate><![CDATA[20231124]]></pubDate></item>
<item>
<title><![CDATA[Automatic Video Melting Point Meter]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Automatic_Video_Melting_Point_Meter--11600339_11723479.html]]></link><description><![CDATA[measuring the melting point of a substance. The melting point of a substance refers to the temperature at which the substance changes from solid to liquid. In the field of organic chemistry, the dete]]></description><pubDate><![CDATA[20230208]]></pubDate></item>
<item>
<title><![CDATA[Hydraulic Liner Hanger Tie-Back Assembly]]></title><link><![CDATA[https://saigaogroup.en.ec21.com/Hydraulic_Liner_Hanger_Tie_Back--11093688_11181033.html]]></link><description><![CDATA[measurement error and the remaining threads of the casings.)
B. Polishing the polished bore tie back receptacle
Connect the milling shoe and trip in. Polish the inner surface of the polished bore rec]]></description><pubDate><![CDATA[20200622]]></pubDate></item>
<item>
<title><![CDATA[Natural Dry Casings Air Dried Natural Hog Casings Tubed China]]></title><link><![CDATA[https://xidongguang.en.ec21.com/Natural_Dry_Casings_Air_Dried--10937039_11581456.html]]></link><description><![CDATA[measurements, aspects that make it the perfect substitute in products that use natural hog casings: fatends, afterends etc.
Our United Dry casing possesses all the advantages associated with natural ]]></description><pubDate><![CDATA[20220605]]></pubDate></item>
<item>
<title><![CDATA[NOVA New and Original IC BUF NON-INVERT 5.5V SOT23-5 SN74LVC1G125DBVR]]></title><link><![CDATA[https://hknovatech.en.ec21.com/NOVA_New_and_Original_IC--11889683_11890202.html]]></link><description><![CDATA[Temperature-40°C ~ 125°C (TA) Mounting TypeSurface Mount Package / CaseSC-74A, SOT-753 Supplier Device PackageSOT-23-5 Base Product Number74LVC1G125 
Q1:What service do you have?
We provide turnkey]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Mestar Ph/Orp Controller]]></title><link><![CDATA[https://cheonsei.en.ec21.com/Mestar_Ph_Orp_Controller--1_3203598.html]]></link><description><![CDATA[Feature 
pH/ORP selection 
Auto Calibration 
- pH4,7,9 
- Improved measuring precision by auto operation of liquid temperature 
- Full duplex communication by RS-485 
- Available for recorder, indica]]></description><pubDate><![CDATA[20070313]]></pubDate></item>
<item>
<title><![CDATA[Cone Calorimeter, ISO5660, ASTM E1354]]></title><link><![CDATA[https://kobistq.en.ec21.com/Cone_Calorimeter_ISO5660_ASTM_E1354--1_3233195.html]]></link><description><![CDATA[temperature controller. Split Shutter Mechanism - protects the sample area before the beginning of the test. In this way, the initial mass measurement can stabilise before beginning the actual test a]]></description><pubDate><![CDATA[20081012]]></pubDate></item>
<item>
<title><![CDATA[Special Purpose Reactor - Polymerization Reactor]]></title><link><![CDATA[https://ilshinauto.en.ec21.com/Special_Purpose_Reactor_Polymerization_Reactor--8932238_3722698.html]]></link><description><![CDATA[temperature by internal/external insulation 
- Improve safety through the multi-safety devices 
Customized engineering 
- A variety of types and specification for customer 
- Different types of resea]]></description><pubDate><![CDATA[20180919]]></pubDate></item>
<item>
<title><![CDATA[Picosecond Laser Glass Cutting Machine]]></title><link><![CDATA[https://cmbio12.en.ec21.com/Picosecond_Laser_Glass_Cutting_Machine--11774782_11774789.html]]></link><description><![CDATA[Width Measured at 1064nm: 10 picoseconds
Pointing Stability Over Constant Temperature +/2 °C: &lt; 50 μrad / °C
Machine weight:&gt;5ton
Picosend cutting speed:500mm/s
Laser cutting head:Bessel
VIDEO
]]></description><pubDate><![CDATA[20240318]]></pubDate></item>
<item>
<title><![CDATA[Torque Tube, Displacement Type Level Transmitter (SDT-420)]]></title><link><![CDATA[https://seojinkt.en.ec21.com/Torque_Tube_Displacement_Type_Level--1373220_1419370.html]]></link><description><![CDATA[Measurement range : 300~5,000mm.
Process temperature : Wetted parts -40 ~ 450&amp;#176;C
Process pressure : 200 f/cm2
Output signal : 2-Wire type 4~20mA, HART, LCD.
Range of specific gravity : 0.5~1.5.
A]]></description><pubDate><![CDATA[20150101]]></pubDate></item>
<item>
<title><![CDATA[Digital Level Meter]]></title><link><![CDATA[https://bymachin.en.ec21.com/Digital_Level_Meter--965925_10210917.html]]></link><description><![CDATA[Temperature Range : -196℃ ~ 40℃ 
- Voltage : 220Volt(Battery: 12Volt) 
- Size : 200*150*100mm 
- LCD Size : 115*65mm 
- Connection : DIN 43650 
- Communication : 485 CABLE, WIFI 
- Printing Metho]]></description><pubDate><![CDATA[20161108]]></pubDate></item>
<item>
<title><![CDATA[Vacuum Orange Juice Extractor and Concentrator Machine Equipment]]></title><link><![CDATA[https://jnban733.en.ec21.com/Vacuum_Orange_Juice_Extractor_and--11590864_11785676.html]]></link><description><![CDATA[temperature is also related to pressure where increase in temperature leads to increase in pressure and vice-versa.●Temperature Temperature measures the level of heat energy that you will use in th]]></description><pubDate><![CDATA[20230509]]></pubDate></item>
<item>
<title><![CDATA[A/C Calorimeter]]></title><link><![CDATA[https://systemq.en.ec21.com/A_C_Calorimeter--2607191_2607196.html]]></link><description><![CDATA[measuring the air 
flow,temperature and humidity at the inlet and outlet of room side and outdoorside.components 
of the unit to be tested simultaneously.This equipment can be varied many types 
in c]]></description><pubDate><![CDATA[20121108]]></pubDate></item>
<item>
<title><![CDATA[ABB Gauge Pressure Transmitters 266GDT 266GRH 266GRT 266GSH 266GST 266HDH  2600T Series]]></title><link><![CDATA[https://contranspower.en.ec21.com/ABB_Gauge_Pressure_Transmitters_266GDT--9929422_9929881.html]]></link><description><![CDATA[temperature ranges. It is a reliable sensing system coupled with the very latest digital technologies. The user has a comprehensive choice of sensors, optimizing in-use total performance and stabilit]]></description><pubDate><![CDATA[20200827]]></pubDate></item>

</channel>
</rss>