<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 25kv cable]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/25kv-cable--092508/1/25kv cable.html]]></link><item>
<title><![CDATA[H1z2z2-K/PV1-F 1800V DC Solar Cable 4mm2, TUV 2 Pfg 1169/08.2007, 0.6/1kv]]></title><link><![CDATA[https://ningbopntech.en.ec21.com/H1z2z2-K-PV1-F-1800V--10424135_10425169.html]]></link><description><![CDATA[H1z2z2-K/PV1-F 1800V DC Solar Cable 4mm2, TUV 2 Pfg 1169/08.2007, 0.6/1kv
Specificate
Rated for 1.8 KV DC operationAnnealed Tinned Flexible Copper, XLPO Insulation &amp; SheathElectron Beam Irradiation C]]></description><pubDate><![CDATA[20240710]]></pubDate></item>
<item>
<title><![CDATA[XLPE Insulated Power Cable]]></title><link><![CDATA[https://mdcable.en.ec21.com/XLPE-Insulated-Power-Cable--11911097_11911100.html]]></link><description><![CDATA[250C . The short-circuit duration shall not exceed 5 seconds.
Bending Radius: 20( d+D) +/-5% for single core cable,15( d+D )+/-5% for multi-core cable.
D=Actual outer diameter of cable (mm),d=Actual ]]></description><pubDate><![CDATA[20240312]]></pubDate></item>
<item>
<title><![CDATA[ASTM Low Voltage Power Cable , Aluminum PVC 120mm 4 Core Cable 1kV]]></title><link><![CDATA[https://insulatecablecom.en.ec21.com/ASTM-Low-Voltage-Power-Cable--11875960_11875961.html]]></link><description><![CDATA[(Ω / km)copper0.2680.1930.1530.1240.09910.07540.06010.0470 aluminium0.4430.3200.2530.2060.1640.1250.1000.0778 4.2 Finished cable shall be subjected to 3.5kV / 5min voltage test without breakdown.
]]></description><pubDate><![CDATA[20231215]]></pubDate></item>
<item>
<title><![CDATA[33kv Xlpe Single Core Cable Tano Cable Hot Sales!]]></title><link><![CDATA[https://mariatanocable.en.ec21.com/33kv-Xlpe-Single-Core-Cable--9873647_9968323.html]]></link><description><![CDATA[kv Xlpe Single Core Cable 
Operating Temperature: up to 90&amp;deg;C 
Temperature Range: -5&amp;deg;C ( PVC sheath ); -20&amp;deg;C ( PE sheath ) 
Short Circuit Temperature: 250&amp;deg;C (short circuit duration up ]]></description><pubDate><![CDATA[20160510]]></pubDate></item>
<item>
<title><![CDATA[Rated Voltage 0.6/1.0 KV and Below PVC Insulated Power Cable]]></title><link><![CDATA[https://hycables.en.ec21.com/Rated-Voltage-0.6-1.0-KV--10846429_10846433.html]]></link><description><![CDATA[Rated Voltage 0.6/1.0 KV and Below PVC Insulated Power Cable
Product Standard
GB/T 12706-2008 standard equivalent to IEC502(2004).
Usage
This product is suitable for use in rated AC voltage(U0/U) 0.6]]></description><pubDate><![CDATA[20231009]]></pubDate></item>
<item>
<title><![CDATA[MV105 Cable]]></title><link><![CDATA[https://fabregaszhou.en.ec21.com/MV105-Cable--10917399_10917413.html]]></link><description><![CDATA[Cables Rated 5kV-46kV.
Example: MV-105 Power Cable,8kV,3 cores,CU/EPR/CTS/CPE
Standards: ICEA S-93-639/NEMA WC71/UL 1072
Maximum Operating Voltage: 5kV-25kV 100% and 133% IL Maximum conductor operati]]></description><pubDate><![CDATA[20190311]]></pubDate></item>
<item>
<title><![CDATA[XLPE Insulated Low Voltage Power Cable]]></title><link><![CDATA[https://fulihuabic.en.ec21.com/XLPE-Insulated-Low-Voltage-Power--1358714_7677896.html]]></link><description><![CDATA[cable: 
1. CE,ISO,SGS..Certificate 
2. IEC Standard 
3. Exported to Many Countries
PVC Insulated Power Cable:
0.6/1 KV PVC insulated power cable is used for electric power transmission and distributi]]></description><pubDate><![CDATA[20171018]]></pubDate></item>
<item>
<title><![CDATA[With Power Cable/33kv Single Core Power Cable/150mm Power Cable]]></title><link><![CDATA[https://xuxueqing123.en.ec21.com/With-Power-Cable-33kv-Single--8819285_8846788.html]]></link><description><![CDATA[250&amp;deg;C (5s maximum duration). 
The ambient temperature under installation should not below 0&amp;deg;C.
The bending radius should not less than 25 times of cable diameter. 
35KV XLPE Insulated Cable 
]]></description><pubDate><![CDATA[20140403]]></pubDate></item>
<item>
<title><![CDATA[Overhead Line Insulation Sleeve]]></title><link><![CDATA[https://casac1997.en.ec21.com/Overhead-Line-Insulation-Sleeve--11726544_11727667.html]]></link><description><![CDATA[KV）
IEC 243
≥25KV/mm
Dielectric strength（for 35KV）
IEC 243
≥42KV/mm
Dielectric constant
IEC 250
≤3.0
Volume resistance
IEC 93
≥1.0x1013Ω•cm
Adhesive to steel
DIN 30672
0.5N/cm
Water ]]></description><pubDate><![CDATA[20230214]]></pubDate></item>
<item>
<title><![CDATA[Semoflex Drum 0,6/1 Kv 36 G 1,5]]></title><link><![CDATA[https://reeltec2016.en.ec21.com/Semoflex-Drum-0-6-1--10951194_10951299.html]]></link><description><![CDATA[cable 0.6/1 kV,resistant against coldness VDE/UL/CSA approved,flamible resistant according to DIN EN 60332-1] Cartridge cable, * VDE-Reg.-Nr.6510 1000 V E195107 cURus Style 10264/20235 80°C 1000 V L]]></description><pubDate><![CDATA[20190507]]></pubDate></item>

</channel>
</rss>