<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - limited 1]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/limited-1--2717/1/limited 1.html]]></link><item>
<title><![CDATA[Fluke TI480 PRO Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke-TI480-PRO-Thermal-Imaging--12045274_12045346.html]]></link><description><![CDATA[12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)Weight (battery included): 1.04 kg (2.3 lb)Enclosure rating: IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all dire]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke-TIX580-Infrared-Camera--11790575_11793442.html]]></link><description><![CDATA[15.9 x 9.7 cm (10.8 x 6.3 x 3.8 in)Weight (battery included)1.54 kg (3.4 lb)Enclosure ratingIEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all direction]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New-Fluke-TI480-PRO-60HZ--11927627_11927630.html]]></link><description><![CDATA[12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in)Weight (battery included1.04 kg (2.3 lb)Enclosure ratingIEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all ]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[YH800C Portable Fully Automatic Pressure Calibrator]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800C-Portable-Fully-Automatic-Pressure--12022422_12033066.html]]></link><description><![CDATA[limited space or complex environments.5. Instrument interface: Provides multiple standard interfaces with strong compatibility, capable of connecting various types of pressure instruments, including ]]></description><pubDate><![CDATA[20241225]]></pubDate></item>
<item>
<title><![CDATA[EMCEE Model 1154 Precision Conductivity Meter]]></title><link><![CDATA[https://xmjielian.en.ec21.com/EMCEE-Model-1154-Precision-Conductivity--11982130_11982350.html]]></link><description><![CDATA[Model 1154 Precision Conductivity Meter(ASTM Standard Test Method D4308)
Four standard ranges provide high resolution and accurate direct measurement of electrical conductivity of fluids from.01 to 2]]></description><pubDate><![CDATA[20240813]]></pubDate></item>
<item>
<title><![CDATA[Thermal Shock Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Thermal-Shock-Test-Chamber--11164019_11164171.html]]></link><description><![CDATA[1300*1950 mm
(approximately)
2750*1200*2000 mm
(approximately)
2350*1640*2640 mm
(approximately)
High temperature area
Temperature exposure range
+60...+200℃
Preheating temperature upper limit
200]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Extra Large Measuring Machine Atlas Series UCC Pantec Controller AC-Dmis for Large Workpieces]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Extra-Large-Measuring-Machine-Atlas--11944568_11944833.html]]></link><description><![CDATA[limit, electrical limit, and hard limit, and long-term unmanned operation power outage protection, greatly improving the safety of equipment use;
Equipped with precision air source filters, the filtr]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[F105/F305/F505/F505H Advanced Test Stand Frame]]></title><link><![CDATA[https://lanetech11.en.ec21.com/F105-F305-F505-F505H-Advanced--11944805_11944810.html]]></link><description><![CDATA[limits or testing exception. Dual-graduated rulers’ aid with switch placement.
4. Perfect force sensor interface
Series FS05 force sensors mount the crosshead of model F105, F305, F505, F505H, no c]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke-754-Documenting-Process-Calibrator--11329183_11550830.html]]></link><description><![CDATA[10 hour uninterrupted use. Includes gas gauge.Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.Delivered with DPC/Track Sample software.Compatible with many Asset Manag]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD30 Constant Acceleration Tester (Box Type)]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD30-Constant-Acceleration-Tester--11098426_11099444.html]]></link><description><![CDATA[limit and
over-speed protection can be realized.
l 
Multiple control methods: In the case of automatic control failure
or no need of automatic control, the device can still use manual control to
comp]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Tensile Tester for Packaging Tensile Strength Testing Instrument Tear Tester Peel Sterngth Tester]]></title><link><![CDATA[https://celtec.en.ec21.com/Tensile-Tester-for-Packaging-Tensile--9267523_9296157.html]]></link><description><![CDATA[TST-01 Tensile Tester
Introduction
The TST-01 Tensile Tester is a versatile instrument designed to evaluate a wide array of material properties, essential for industries ranging from packaging and fo]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[FTT-01 Film Thickness Tester]]></title><link><![CDATA[https://materialstests.en.ec21.com/FTT-01-Film-Thickness-Tester--11896648_11896651.html]]></link><description><![CDATA[FTT-01 Thickness Tester finds its application across a diverse range of materials include but not limited to plastic films, sheets, fabrics, textiles, membranes, paper, foil, wafers.
]]></description><pubDate><![CDATA[20240202]]></pubDate></item>
<item>
<title><![CDATA[SYAL-H Rapid Concrete Alkali Tester]]></title><link><![CDATA[https://samyontech.en.ec21.com/SYAL-H-Rapid-Concrete-Alkali--9452118_9452224.html]]></link><description><![CDATA[Executive Standard 
1. &amp;lsquo;Standard for Maximum Alkali Content in Concrete&amp;rsquo; CECS 53: 93 
2. &amp;lsquo;Standard for Durability Assessment of Concrete Structures&amp;rsquo; CECS 220:2007 
Detection m]]></description><pubDate><![CDATA[20161117]]></pubDate></item>
<item>
<title><![CDATA[FLIR T530 24 Thermal Cameras with 24 Degree Lens, 30Hz]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/FLIR-T530-24-Thermal-Cameras--11561118_11567071.html]]></link><description><![CDATA[10) Folder structure for storing images11) Faster USB C chargingWarranty2 YEARSWarranty DetailsFLIR 2-5-10 Global Limited Warranty (2 years/components, 5 years/battery, 10 years/detector)Safety Appro]]></description><pubDate><![CDATA[20230930]]></pubDate></item>
<item>
<title><![CDATA[High Precision Rotation Luminaire Goniophotometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High-Precision-Rotation-Luminaire-Goniophotometer--9657760_11802783.html]]></link><description><![CDATA[What is goniophotometer definition?LSG-1890B/LSG-1800A goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for rotating the light s]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP-Linear-DC-Power-Supply--9605857_9605884.html]]></link><description><![CDATA[1.5 times of rated value.
Current-limit protection: User set current-limit value, output current will be limited at current-limit value when load has fault.
Short alarm: sound &amp; light alarm when outp]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[NACTP Automatic CT PT Comprehensive Analyzer]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/NACTP-Automatic-CT-PT-Comprehensive--10586979_10716664.html]]></link><description><![CDATA[10% or 5% error curve, accuracy limit factor (ALF), instrument safety factor (FS), secondary time constant (Ts), remanence factor (Kr), saturated and unsaturated inductance and other parameters of CT]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[TJH-2C Parallel Beam Load Cell]]></title><link><![CDATA[https://tgloadcells.en.ec21.com/TJH-2C-Parallel-Beam-Load--11543401_11592317.html]]></link><description><![CDATA[10℃
Temperature Effect On Output
±0.02% FS/10℃
Operating Temperature Range
-20~+65 ℃
Input Resistance
380±10 Ω
Output Resistance
350± 3 Ω
Insulation Resistance
＞5000 MΩ
Safe Load Limit
]]></description><pubDate><![CDATA[20220624]]></pubDate></item>
<item>
<title><![CDATA[Made in China HZ-3120A Automatic Transformer DC Winding Resistance Tester]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Made-in-China-HZ-3120A--10544358_10544703.html]]></link><description><![CDATA[hz-3120 digital 20A transformer dc widerstand tester 
details
ZS type capacitance and inductance tester. The tester can measure a single capacitor group of capacitors in parallel in the state without]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[Coefficient of Friction COF Tester Testing Equipment]]></title><link><![CDATA[https://idminstruments.en.ec21.com/Coefficient-of-Friction-COF-Tester--10741635_10741651.html]]></link><description><![CDATA[limits 
Other options include:
C0055-OP1: COF Data Acquisition Software (not available for rent)
C0055-OP2: 180&amp;deg; Peel Fixture Rod C0055-SP1: Updated COF Software (only if C0055-OP1 has been previ]]></description><pubDate><![CDATA[20180626]]></pubDate></item>
<item>
<title><![CDATA[Headform Test Device]]></title><link><![CDATA[https://yuanchenwujin68.en.ec21.com/Headform-Test-Device--11261873_10963358.html]]></link><description><![CDATA[10 Head-form test
-ISO 15082 Road vehicles — Tests for rigid plastic safety glazing materials
GB/T 5137.1 Road vehicles--Safety glazing materials
--Part 1: Test methods for mechanical properties
Ma]]></description><pubDate><![CDATA[20230719]]></pubDate></item>
<item>
<title><![CDATA[High Precision Rotation Luminaire Goniospectroradiometer]]></title><link><![CDATA[https://15317383997.en.ec21.com/High-Precision-Rotation-Luminaire-Goniospectroradiometer--11812738_11812746.html]]></link><description><![CDATA[Basic Info.Model NO.LSG-1890BCCDAfter-sales ServicePerfectWarranty24monthsTrademarkLISUNOriginChinaProduct DescriptionLSG-1890BCCD/LSG-1800ACCD goniospectroradiometer is high precision automatic goni]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[GF1061 Portable CT PT Analyzer Is Mainly Used for Field or Lab Testing, It Can Finish the Measuremen]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/GF1061-Portable-CT-PT-Analyzer--10658146_10658147.html]]></link><description><![CDATA[1. Excitation characteristic test
2. Transformation ratio test
2. Transformation ratio test
3. Polarity
3. Polarity
4. 5% and 10% error curve
4. Ratio error, phase error
5. Accuracy limiting factor (]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[Dual Footwear / Wrist Strap Tester_001-6509]]></title><link><![CDATA[https://esdman01.en.ec21.com/Dual-Footwear-Wrist--11607598_11608905.html]]></link><description><![CDATA[1. Comply with ISO/CD8782-I Standard
2. Comply with the limit request of ANSI/ESD S20.20 on calibration test for wrist strap/human body system resistance and footwear/human body resistance 
3. Comply]]></description><pubDate><![CDATA[20230327]]></pubDate></item>
<item>
<title><![CDATA[100k - 10T Micro Signal Type Tester Resistance Capacitance and Inductance Tester]]></title><link><![CDATA[https://techmizetest.en.ec21.com/100k-10T-Micro--11890824_11890825.html]]></link><description><![CDATA[1M,Range6: 1nA - 10nA, input internal resistance: 1M.Test Accuracy2%+3pAVoltage TestRange1V - 1000V1V - 500VAccuracyVoltage≥10V1%+1V,Voltage＜10V10%+0.1V.Current Limit10mASwitchTurnit on or off ma]]></description><pubDate><![CDATA[20240119]]></pubDate></item>
<item>
<title><![CDATA[DC Motor Armature Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/DC-Motor-Armature-Testing-Equipment--11085938_11085990.html]]></link><description><![CDATA[10/20mA
Leakage current precision 
≤±2.5% measuring range +3 words
Surge 
Voltage range
0-3000V
Voltage precision 
≤±2.5% display value+2.5% measuring range+3words
Waveforms limited value
Minim]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Hipot Tester 0.05 - 5kV AC, 0.05 - 6kV DC]]></title><link><![CDATA[https://testron.en.ec21.com/Hipot-Tester-0.05--10983225_10983230.html]]></link><description><![CDATA[10mA. Wide insulation resistance measurement range：1MΩ - 50GΩ. Ground connection test GC.（optional function） Current upper and lower limits setting of programmable leakage current. IR, DC tes]]></description><pubDate><![CDATA[20190719]]></pubDate></item>
<item>
<title><![CDATA[Manifold Filtration Device]]></title><link><![CDATA[https://shenzhilin.en.ec21.com/Manifold-Filtration-Device--11772711_6504599.html]]></link><description><![CDATA[100, 150, 200, 250ml with annular scale line
Membrane Diameter: 47mm and 50mm
Effective filtration area: 12.5 cm2
W x H: 105mmx135mm
Material of Funnel: PP and Stainless Steel
Material of Support: St]]></description><pubDate><![CDATA[20230721]]></pubDate></item>
<item>
<title><![CDATA[Computer Controlled Automobile Seat Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/Computer-Controlled-Automobile-Seat-Testing--4048548_5133616.html]]></link><description><![CDATA[limit protection function of any working position and overvoltage, overcurrent protection functions, reliable, safe;
l with strong test data, which can save, inquire and retrieve test data anytime.
l]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[ST Portable BDV Oil Test Kit,Oil Dielectric Strength Tester]]></title><link><![CDATA[https://aijiezn.en.ec21.com/ST-Portable-BDV-Oil-Test--3459584_11343704.html]]></link><description><![CDATA[100 experimental results, and display the currentenvironment temperature and humidity.
5. The whole process easy to control.
6.With overvoltage, overcurrent, limiting protection, in order to ensure t]]></description><pubDate><![CDATA[20210224]]></pubDate></item>
<item>
<title><![CDATA[UL 1685 Cable Vertical-Tray Flame Test Room]]></title><link><![CDATA[https://satatech.en.ec21.com/UL-1685-Cable-Vertical-Tray--3839683_5279905.html]]></link><description><![CDATA[limited smoke marking.
This test does not investigate the Toxicity of the products of combustion or Decomposition and the Constructional Requirements for the cable or any electrical, optical, or othe]]></description><pubDate><![CDATA[20201002]]></pubDate></item>
<item>
<title><![CDATA[BST-01 Ampoule Breaking Tester]]></title><link><![CDATA[https://celtec3.en.ec21.com/BST-01-Ampoule-Breaking-Tester--11861428_11861434.html]]></link><description><![CDATA[1ml, 2ml, 5ml, 10ml, and 20ml, accommodating different specifications. 
2.Availability of multiple fixtures for testing various materials used in medical packaging. 
3 .Incorporation of a limiting de]]></description><pubDate><![CDATA[20231101]]></pubDate></item>
<item>
<title><![CDATA[Thermal Shock Test Chamber (Two Zones)]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Thermal-Shock-Test-Chamber--11853101_11853190.html]]></link><description><![CDATA[1125*2030 mm
2750*1200*2000 mm
2350*1640*2640 mm
High temperature area
Temperature exposure
range
+60～+200℃
Preheating temperature
upper limit
200℃
Heating time
R.T～+200℃:40 min (approximat]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[Medium Voltage Surge Arresters]]></title><link><![CDATA[https://yfpower.en.ec21.com/Medium-Voltage-Surge-Arresters--11836088_11836092.html]]></link><description><![CDATA[1kV and 36kV, and they are commonly found in various industries, such as manufacturing, oil and gas, and utilities.
Medium surge arrester medium voltage
work by detecting and diverting excess voltage]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[V-Sorb 2800TP Surface Area and Porosimtery Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/V-Sorb-2800TP-Surface-Area--7277224_7277091.html]]></link><description><![CDATA[1 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit (specific surface area); 0.35 to 500nm (pore size)
Accuracy: repeatability errors ≤1%
Coolant Level Prober: V-Sorb original coo]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[5kVA~7000kVA 2MVA/5MVA AC Dummy Resistive Inductive Load Bank for Generator/Genset Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/5kVA-7000kVA-2MVA-5MVA-AC--11807080_11807102.html]]></link><description><![CDATA[limit switch/grounding protection/over current protection/over voltage protection/smoke alarm protection/lighting and wall switchesDimension6000*2438*2900mm(L.W.H)Weight17000kg
Company Profile
Certif]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[18650 Lithium Battery]]></title><link><![CDATA[https://chamglobal.en.ec21.com/18650-Lithium-Battery--11857535_11857537.html]]></link><description><![CDATA[140, 40135, and 4680 series. A cylindrical cell is a cell enclosed in a cylinder-shaped case, it has an excellent energy density and the high voltage ensures more power to provide in limited space. B]]></description><pubDate><![CDATA[20231023]]></pubDate></item>
<item>
<title><![CDATA[Ponovo PCT200 Series CT and PT Test Set for Current Transformer and PT Reference Testing Functi]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo-PCT200-Series-CT-and--11744128_7404184.html]]></link><description><![CDATA[1%±1mΩ Gur
Winding resistance test
Range
0.001-1000 ohm
Accuracy
±0.1%±1mΩ Gur
Phase displacement check
Accuracy
2 min Gur
Resolution
0.01 min
Other test functions
Accuracy limiting factor
Yes
I]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Refractometer RA-620 / RA-600]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Refractometer-RA-620--8755029_8755113.html]]></link><description><![CDATA[1:By KEM&amp;rsquo;s standard measurement conditions. *2:From RI accuracy of results. 
*3:By KEM&amp;rsquo;s standard measurement conditions. Subject to sample properties. *4:Lower limit 12&amp;deg;C below ambie]]></description><pubDate><![CDATA[20140212]]></pubDate></item>
<item>
<title><![CDATA[JY-1016 800*800 MM Box Compression Tester Carton Compression Strength Test Machine]]></title><link><![CDATA[https://cicichenchen.en.ec21.com/JY-1016-800-800-MM--11468520_11567819.html]]></link><description><![CDATA[10 ±3mm/min (0.01~200mm/min adjustable)
Software
TM 2101
Data display
Load, displacement, speed, loading rate and elapsed time
Safety features
E-Stop
Over-load protection
Upper and lower limit switc]]></description><pubDate><![CDATA[20220514]]></pubDate></item>
<item>
<title><![CDATA[Oxygen Permeability Analyzer Tester Instrument for Package Material Laboratory Equipment]]></title><link><![CDATA[https://gbpitester.en.ec21.com/Oxygen-Permeability-Analyzer-Tester-Instrument--11629254_11631106.html]]></link><description><![CDATA[Products DescriptionY310 Oxygen Permeability AnalyzerApplication Y310 Oxygen Permeability Analyzer is to test the oxygen transmission rate (OTR) of films or sheets materials.
Standard GB/T19789-2005]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Thickness Meter TM-8812 for Sale]]></title><link><![CDATA[https://105landtek.en.ec21.com/Ultrasonic-Thickness-Meter-TM-8812--9545005_11795523.html]]></link><description><![CDATA[10 mm LCD
Operating Principle: Ultrasonic
Measuring Range (metric / Imperial): 1.0~200 mm / 0.04~8 inch
Battery Indication: Low Battery Indication
Sound Velocity:500~9990 m/s
Lower Limit Steel Pipes:]]></description><pubDate><![CDATA[20230523]]></pubDate></item>
<item>
<title><![CDATA[LM-79 Moving Detector Goniophotometer (Mirror Type C)]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/LM-79-Moving-Detector-Goniophotometer--11882688_11882689.html]]></link><description><![CDATA[What is the definition of type C goniophotometer?LSG-6000 Moving Detector Goniophotometer (Mirror Type C) was manufactured by LISUN completely meets LM-79-19, IES LM-80-08, COMMISSION DELEGATED REGUL]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Multi-function Optical Fiber Light Source CEL-FES300 Photocatalysis]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Multi-function-Optical-Fiber-Light--11446837_11446865.html]]></link><description><![CDATA[18.6W、5600KPower(Watts)300W（Lighting voltage 15KV，Working voltage14V）New 300W special power supply
Current (Amps DC)21A（10A~22A）Total luminous output power50WLife（Hours）&gt;1000H Limit 6]]></description><pubDate><![CDATA[20221027]]></pubDate></item>
<item>
<title><![CDATA[Computer Servo System Double-Column Tensile Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Computer-Servo-System-Double-Column--11372348_11372351.html]]></link><description><![CDATA[Technical parameters 1. The maximum tension stress LOAD yuan LOAD: 10 kg, 20 kg, 50 kg, 100 kg, 200 kg, 500 kg, 1000 kg, 2000 kg2. Unit switching: all kinds of international units can be arbitrarily ]]></description><pubDate><![CDATA[20210423]]></pubDate></item>
<item>
<title><![CDATA[YFT-D300 Pressure Relief Valve Test Bench for Safety Valve Pressure Calibration and Sealing Test]]></title><link><![CDATA[https://king3834656.en.ec21.com/YFT-D300-Pressure-Relief-Valve--11745449_11747554.html]]></link><description><![CDATA[Technical performance and feature: 
1. it is suitable for safety valve performance test.2. Test medium is nitrogen gas or air(gas source is supplied by customer)3. high pressure air fill in the cavit]]></description><pubDate><![CDATA[20230330]]></pubDate></item>

</channel>
</rss>