<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - low static pressure]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/low-static-pressure--2717/1/low static pressure.html]]></link><item>
<title><![CDATA[Extra Large Measuring Machine Atlas Series UCC Pantec Controller AC-Dmis for Large Workpieces]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Extra-Large-Measuring-Machine-Atlas--11944568_11944833.html]]></link><description><![CDATA[static pressure floating guide rail composed of self-cleaning pre load high-precision air bearings. The bearing has a large span, strong resistance to angular swing, low resistance, no wear, and smoo]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Liquid Chromatograph]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Liquid-Chromatograph--11907876_11909750.html]]></link><description><![CDATA[pressure constant current infusion pump
Infusion method: Micro volume series double plunger
Maximum infusion pressure 0-9999Psi
Flow setting range: 0.001~9.999ml/min (adjust flow rate in steps of 0.0]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Furniture Mechanics Comprehensive Test Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Hot-Sale-Furniture-Mechanics-Comprehensive--11365007_11365011.html]]></link><description><![CDATA[pressure regulating oil and water filtering, position sensor and other self-dynamic test pieces, whether or not damaged, and automatically stop the test. 
9. The report is divided into single cylinde]]></description><pubDate><![CDATA[20210416]]></pubDate></item>
<item>
<title><![CDATA[Model CLG-160 Aluminium Wheel RTR System]]></title><link><![CDATA[https://ndtchina.en.ec21.com/Model-CLG-160-Aluminium-Wheel--6581053_6161286.html]]></link><description><![CDATA[low pressure casting, gravity casting
Technical parameter
Max penetration: 110mm (AI)
Space resolution: 2.4-2.8lp/mm
Real time static sensitivity: 3.0%
Sensitivity after processing: 1.5-2.0%
Speed (1]]></description><pubDate><![CDATA[20140520]]></pubDate></item>
<item>
<title><![CDATA[V-Sorb 4800P Surface Area and Porosimtery Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/V-Sorb-4800P-Surface-Area--7277224_7277115.html]]></link><description><![CDATA[Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)Transducer Accuracy: ]]></description><pubDate><![CDATA[20240118]]></pubDate></item>

</channel>
</rss>