<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - precise temperature controls]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/precise-temperature-controls--2717/1/precise temperature controls.html]]></link><item>
<title><![CDATA[Fluke TI480 PRO Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke-TI480-PRO-Thermal-Imaging--12045274_12045346.html]]></link><description><![CDATA[control operation: Yes, through SmartView® software or Fluke Connect® mobile appAuto capture (temperature and interval): YesBattery
Batteries (field-replaceable, rechargeable): Two lithium ion smar]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO 60 Hz, 640 X 480 High-Performance IR Thermal Camera]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke-TI480-PRO-60-Hz--11561118_11932301.html]]></link><description><![CDATA[Temperature measurement range (not calibrated below -10 �C): ?-10 �C to +1000 �C (14 �F to 1832 �F)
Accuracy: � 2 �C or 2% (at 25 �C nominal, whichever is greater)
Reduce need take no]]></description><pubDate><![CDATA[20250129]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke-TIX580-Infrared-Camera--11790575_11793442.html]]></link><description><![CDATA[control operationYes, through Fluke Connect SmartView desktop software or Fluke Connect mobile appAuto capture (temperature and interval)YesMATLAB® and LabVIEW® tool boxesIntegrate camera data, inf]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New-Fluke-TI480-PRO-60HZ--11927627_11927630.html]]></link><description><![CDATA[control operationYes, through SmartView® software or Fluke Connect® mobile appAuto capture (temperature and interval)YesBatteryBatteries (field-replaceable, rechargeable)Two lithium ion smart batte]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[WDLYCH/WDLHCN CCS Marine Analog Panel Current Meter/Ammeter for Switchboards]]></title><link><![CDATA[https://jade900920.en.ec21.com/WDLYCH-WDLHCN-CCS-Marine-Analog--11663243_12026218.html]]></link><description><![CDATA[Temperature
-13-33℃, 100% comply with accuracy class
Technical Standards
GB/T7676-1998
Environment
GB8355-1987
Safety Standards
GB4793-20
Working Temperature
-40℃-65℃
Options: 
1. Transmitting ]]></description><pubDate><![CDATA[20241227]]></pubDate></item>
<item>
<title><![CDATA[YH701 Temperature and Humidity Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH701-Temperature-and-Humidity-Calibration--12022540_12022544.html]]></link><description><![CDATA[control, easy to operate, beautiful interface, precise control.
◆The interior of the working space is designed with stainless steel and no dead corners. The temperature and humidity field is unifor]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[Smoke Detector]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke-Detector--11987076_11987700.html]]></link><description><![CDATA[temperature test
function of smoke fire alarm: room temperature ~ 55 ° C, temperature control
accuracy + / - 1 ° C, dry heat sensitivity test can be carried out in the smoke
box, standards can be s]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Dissolved Ozone Meter Intelligent Online Water Ozone Analyzer Tester Sanitizer Ozone]]></title><link><![CDATA[https://nobotech.en.ec21.com/Dissolved-Ozone-Meter-Intelligent-Online--11181496_11182362.html]]></link><description><![CDATA[temperature:0~60℃◇Resolution0.01mg/L, 0.1℃◇Accuracy ±1% or ±0.01 mg/L, ±0.5℃ ◇Temperature compensation function0~60℃(manual/automatic).◇Control interfaceTwo groups of ON/OFF relay ]]></description><pubDate><![CDATA[20240929]]></pubDate></item>
<item>
<title><![CDATA[Isotech 4852 ADVANCED]]></title><link><![CDATA[https://nelsoncalib1.en.ec21.com/Isotech-4852-ADVANCED--11979684_11979688.html]]></link><description><![CDATA[Temperature Measurement Tools: Infrared thermometers, thermocouples, and controllers
Torque Tools: Wrenches, screwdrivers, and testers
Commitment to Quality
We prioritize precision and reliability, s]]></description><pubDate><![CDATA[20240803]]></pubDate></item>
<item>
<title><![CDATA[Surface Roughness Gauge]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Surface-Roughness-Gauge--11973711_11973717.html]]></link><description><![CDATA[Surface Roughness Gauge
Delve into the world of precise surface finish measurement with AJR&apos;s state-of-the-art Art300 Surface Roughness Gauge. As a leading roughness gauge manufacturer, AJR
brings yo]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[Additel ADT761]]></title><link><![CDATA[https://wisnuprecision12.en.ec21.com/Additel-ADT761--11972561_11972566.html]]></link><description><![CDATA[controlled automatically from 90% vacuum to 375 psi (25 bar)Pressure measured with external pressure modules (ADT160 series) to 10,000 psi (700 bar)0.02%FSFully temperature compensated0.005%FSFully A]]></description><pubDate><![CDATA[20240722]]></pubDate></item>
<item>
<title><![CDATA[NDJ-8T Lab Digital Rotating Viscosity Meter Viscosimeter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ-8T-Lab-Digital-Rotating--11144324_11144457.html]]></link><description><![CDATA[precision and small error;
3.Display
content is rich: in addition to viscosity, there are temperature, shear
rate, shear stress, measured value as a percentage of full scale value 
(graphic display),]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Hot Rolled Bar Outer Diameter Measuring Instrument GDC-J2400-JX]]></title><link><![CDATA[https://measurementon.en.ec21.com/Hot-Rolled-Bar-Outer-Diameter--11962128_11962129.html]]></link><description><![CDATA[control cabinet, measuring vehicle, electrical control box, LED display, cooling and dust removal system and supporting facilities.
Adaptable rolling speed: ≤120m/s
Adaptable rolling temperature: ]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[Shortwave Infrared SWIR TEC Cooled Thermal Camera with InGaAs Detector for Target Measurement]]></title><link><![CDATA[https://leadir.en.ec21.com/Shortwave-Infrared-SWIR-TEC-Cooled--11956357_11954588.html]]></link><description><![CDATA[precise temperature control, with the temperature difference up to 40℃.
² Non-uniformity correction, filtering and enhancement algorithms.
² Miniaturization, low power consumption, high frame fre]]></description><pubDate><![CDATA[20240620]]></pubDate></item>
<item>
<title><![CDATA[Extra Large Measuring Machine Atlas Series UCC Pantec Controller AC-Dmis for Large Workpieces]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Extra-Large-Measuring-Machine-Atlas--11944568_11944833.html]]></link><description><![CDATA[precise temperature correction. All four axes adopt a fully closed-loop position detection system with a resolution of 0.1 μ m, ensuring the repeated accuracy of machine measurements; 
The grating r]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Digital Infrared Radiometer]]></title><link><![CDATA[https://gatherstar.en.ec21.com/Digital-Infrared-Radiometer--11943208_11943246.html]]></link><description><![CDATA[Temperature 
-40℃ 
~ +50
℃
Dimension 
279（L）* 202（H）*274（D）---RLK601、RLK602、RLK602D
368（L）* 202（H）*274（D）---RLK603 
Weight 
8.0Kg(RLK601、RLK602、RLK602D)/10Kg(RLK60]]></description><pubDate><![CDATA[20240527]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 IPX1-4 Comprehensive Waterproof Test Chamber Integrated with Drip Box and Oscillating Tubes]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60529-IPX1-4-Comprehensive-Waterproof--11940576_11940977.html]]></link><description><![CDATA[precision adjustable. 
● Turntable drive: adopts Chinese branded step motor, can adjust the speed and angle by touch screen, and auto control the directions (fit for the samples to do live test).
]]></description><pubDate><![CDATA[20240522]]></pubDate></item>
<item>
<title><![CDATA[HTT-02 Hot Tack Tester]]></title><link><![CDATA[https://materialstests.en.ec21.com/HTT-02-Hot-Tack-Tester--11896648_11938409.html]]></link><description><![CDATA[Temperature Control:
The HTT-02 maintains precise temperature control during testing to simulate the conditions encountered during the sealing process accurately.
3.Pressure Application:
It applies c]]></description><pubDate><![CDATA[20240517]]></pubDate></item>
<item>
<title><![CDATA[Master Meter Gas Flow Calibration System]]></title><link><![CDATA[https://tnmacalibration.en.ec21.com/Master-Meter-Gas-Flow-Calibration--11926262_11926263.html]]></link><description><![CDATA[precise and reliable system.
The entire system operates under PC control, enabling fully automated testing with comprehensive features such as storing, querying, and printing of raw data.
For more de]]></description><pubDate><![CDATA[20240417]]></pubDate></item>
<item>
<title><![CDATA[KRD101 Custom Printed Packaging Cardboard Compression Testing Machine]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD101-Custom-Printed-Packaging-Cardboard--11098426_11099497.html]]></link><description><![CDATA[precision AD conversion,
preamplifier, data processing and automatic test result output, digital control
to ensure test accuracy and stable performance. 
l 
The strength test, fixed value
test and]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Heat Seal Tester ASTM F2029 Plastic Film Heat Seal Data Testing Instrument for Sale]]></title><link><![CDATA[https://celtec.en.ec21.com/Heat-Seal-Tester-ASTM-F2029--9267519_9168948.html]]></link><description><![CDATA[temperature during sealing.
3. State-of-the-art P.I.D. temperature controller for precise temperature regulation and efficient heating.
4. Accurate timing facilitated by a proximity sensor, enabling ]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[Reference Fuel Blender for Waukesha CFR Engine Motor]]></title><link><![CDATA[https://sinpar.en.ec21.com/Reference-Fuel-Blender-for-Waukesha--11037244_11913286.html]]></link><description><![CDATA[controls the whole blending process to eliminate human error and improve the efficiency of octane/cetane testing.
◼ Safety and Real-Time Monitoring
The unit is equipped with electrical protection &amp;]]></description><pubDate><![CDATA[20240319]]></pubDate></item>
<item>
<title><![CDATA[ZHLB Bell Porver]]></title><link><![CDATA[https://royreal.en.ec21.com/ZHLB-Bell-Porver--11907986_11909901.html]]></link><description><![CDATA[control system.
Product Features
1. Temperature and pressure measurement accuracy is high, the bus real-time high-speed transmission of measured values.2. High precision position sensing detection of]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[Liquid Chromatograph]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Liquid-Chromatograph--11907876_11909750.html]]></link><description><![CDATA[temperature range: 4~40 ℃
UV visible variable wavelength detector
Wavelength range 190nm~700nm
Wavelength indication error ≤ ± 1nm
Wavelength repeatability error ≤ ± 0.1nm
Dynamic noise ≤ ]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[Walk-in High Low Temperature (Humidity) Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Walk-in-High-Low-Temperature--11853101_11853655.html]]></link><description><![CDATA[Temperature Control mode
BTHC: Balanced temperature &amp; humidity control
system
Performance 
Temperature range
-70℃/-40℃～+100℃ (high temperature +120℃, +150℃ optional)
Humidity range
20%～]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[AST900  Digital Pressure and Temeprature Indicator]]></title><link><![CDATA[https://apexsensor.en.ec21.com/AST900-Digital-Pressure-and--11311676_11311677.html]]></link><description><![CDATA[temperature display
· Three types in size to choose
Application：
It can be widely used not only in situation of display and auto-control in hydraulic pressure, oil, plastics, latex, printing and d]]></description><pubDate><![CDATA[20230623]]></pubDate></item>
<item>
<title><![CDATA[Multi-function Optical Fiber Light Source CEL-FES300 Photocatalysis]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Multi-function-Optical-Fiber-Light--11446837_11446865.html]]></link><description><![CDATA[Temperature control systemhe light source system adopts multi-point temperature monitoring to ensure the stable output of the light source.
The fan speed delay is automatically adjusted according to ]]></description><pubDate><![CDATA[20221027]]></pubDate></item>
<item>
<title><![CDATA[Oxygen Permeability Testing Instrument (OTR Tester)]]></title><link><![CDATA[https://gbpitester.en.ec21.com/Oxygen-Permeability-Testing-Instrument--11629254_11631103.html]]></link><description><![CDATA[Temperature range
15℃~45℃ (5℃~50℃ optional)
Temperature accuracy
±0.1℃
Humidity range
0%RH, 30~90%RH, 100%RH
Humidity accuracy
±2%RH
Gas supply pressure
0.1~0.2MPa
Environment temperature]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Apparent Viscosity At High-Temperature and High-Shear Rate Tester ASTM D548]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Apparent-Viscosity-At-High-Temperature--11718430_11718431.html]]></link><description><![CDATA[control method: digital display PID temperature control
3. Temperature control range: normal temperature to 250±0.5℃
4. Heating method: metal bath heating
5. Pressure adjustment: high precision ne]]></description><pubDate><![CDATA[20230201]]></pubDate></item>
<item>
<title><![CDATA[12PSB Diesel Fuel Injection Pump Test Bench]]></title><link><![CDATA[https://geruisdiesel.en.ec21.com/12PSB-Diesel-Fuel-Injection-Pump--11801992_11801993.html]]></link><description><![CDATA[precision;
4. The functions of over voltage, overload and short circuit protection;
5. Ten classes Rotation speeds presetting;
6. Constant temperature controlled;
7. Ultra low noise;
8. Operating pos]]></description><pubDate><![CDATA[20230605]]></pubDate></item>
<item>
<title><![CDATA[Carbon Dioxide Volume Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Carbon-Dioxide-Volume-Tester--11854816_11854820.html]]></link><description><![CDATA[temperature) ➔ Obtaining the carbon 
dioxide gas capacity test results.
Technical Features 
1.This unit is under precise PLC control (at an industrial-grade stability level) and 
operated through a]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic-Image-Measuring-Device--11683816_11853605.html]]></link><description><![CDATA[controller to realize z-axis automatic focusing.
Hardware and main features:
Precision transmission equipment is designed to realize rapid movement.
High precision marble base, column frame is stable]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[ElectroMechanical Universal Testing Machine]]></title><link><![CDATA[https://jnte.en.ec21.com/ElectroMechanical-Universal-Testing-Machine--1242556_1242626.html]]></link><description><![CDATA[WDW Series Universal Electromechanical Universal Testing Machine
It is computer-controlled precision Testing Machine, suitable for wide range of material for tension, compression, Bending and shearin]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[Precision High Temperature Test Oven]]></title><link><![CDATA[https://irfanzahidi.en.ec21.com/Precision-High-Temperature-Test-Oven--11888191_11888193.html]]></link><description><![CDATA[is adopted to 
ensure that the heat insulation performance meets international standards. The 
precise temperature control system reduces energy consumption, saving up to 20% to 
50% of energy]]></description><pubDate><![CDATA[20240117]]></pubDate></item>
<item>
<title><![CDATA[Temperature Humidity Vibration Chamber Integrated Environmental Test Chamber]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/Temperature-Humidity-Vibration-Chamber-Integrated--11847545_11847551.html]]></link><description><![CDATA[precision perfect appearance design, the external use of double-sided cold rolled plate electrostatic powder coating material, the internal use of SUS#304 high temperature stainless steel.The control]]></description><pubDate><![CDATA[20231107]]></pubDate></item>
<item>
<title><![CDATA[LITE800 Industrial SLA 3D Printer]]></title><link><![CDATA[https://uniontech3d.en.ec21.com/LITE800-Industrial-SLA-3D-Printer--11706631_11807017.html]]></link><description><![CDATA[Control
Closed-loop
Temperature Range
72–79 °F (22–26 °C)
Maximum Change Rate
1 °C/hour
Relative Humidity
&lt; 40%
Machine Size (W x D x H)
1555 × 1445 × 2215 mm
Machine Weight
1050 kg
Initial ]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Computer Controlled Electronic Universal Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/Computer-Controlled-Electronic-Universal-Testing--4048548_4096477.html]]></link><description><![CDATA[precise auto control and data acquisition system to realize full digital adjustment to data acquisition and control process. In the tensile test, it can test max. bearing tension, tensile strength, e]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[Hydraulic Dynamometer/Engine Test Equipment]]></title><link><![CDATA[https://jsxgnn.en.ec21.com/Hydraulic-Dynamometer-Engine-Test-Equipment--5693292_5693383.html]]></link><description><![CDATA[precision(F,S)
+0.05% -0.05%
Max speed(r/min)
2500
Rotation direction
One-way
Brakingforce range(N)
0-35000
Max brakingforce torque(N,M)
33400
Max water consumption(kg/h)
63000
Max temperature (°C)
]]></description><pubDate><![CDATA[20230528]]></pubDate></item>
<item>
<title><![CDATA[ETM-100 100KN Electronic Universal Tensile Test Machine]]></title><link><![CDATA[https://wanchen123.en.ec21.com/ETM-100-100KN-Electronic-Universal--11768103_11774440.html]]></link><description><![CDATA[1.Application 
Microcomputer-controlled universal testing machine is a high-precision, multi-purpose material testing machine that tests the mechanical properties of various metal materials, non-meta]]></description><pubDate><![CDATA[20230423]]></pubDate></item>
<item>
<title><![CDATA[Automatic Melting Point Tester]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Automatic-Melting-Point-Tester--11600339_11776721.html]]></link><description><![CDATA[precise temperature control;
4: Can record and playback the experiment process, not missing every detail;
5: in full compliance with the national standard and ISO oil melting point determination meth]]></description><pubDate><![CDATA[20230426]]></pubDate></item>
<item>
<title><![CDATA[Ultraviolet Light Weathering Testing Machine  QUV Accelerated Weathering Tester]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Ultraviolet-Light-Weathering-Testing-Machine--5441143_9767736.html]]></link><description><![CDATA[controlled, elevated temperatures. 
It simulates the effects of sunlight using special fluorescent UV lamps. 
It simulates dew and rain with condensing humidity and/or water spray. 
The QUV accelerat]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Gas Pycnometer Analyzer G-DenPyc 2900]]></title><link><![CDATA[https://goldapp.en.ec21.com/Gas-Pycnometer-Analyzer-G-DenPyc--9431275_9269540.html]]></link><description><![CDATA[control temperature up and down easily, also hold modules stay at the best temperature(25 C) which can restrain transducer reading’s temperature drift and keep system temperature uniformity; System]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Automatic Cable Metal Wire Spring Material Universal Torsional Force Tester 5000N.M]]></title><link><![CDATA[https://astmtester123.en.ec21.com/Automatic-Cable-Metal-Wire-Spring--10000021_10007380.html]]></link><description><![CDATA[Temperature Torsion Test Method &quot;
ASTM A938-2004
Performance Features
1. Servo motor drive, ensure the reverse speed constancy.
2. Cyclonical reducer drive, ensure driving high efficiency and stabili]]></description><pubDate><![CDATA[20190815]]></pubDate></item>
<item>
<title><![CDATA[200/500/1000/3000/5000N.M Automatic Metal Wire Spring Material Metal Universal Torsion Tester]]></title><link><![CDATA[https://lgtester789.en.ec21.com/200-500-1000-3000-5000N.M--10000318_10050826.html]]></link><description><![CDATA[Temperature Torsion Test Method &quot;
ASTM A938-2004
Performance Features
1. Servo motor drive, ensure the reverse speed constancy.
2. Cyclonical reducer drive, ensure driving high efficiency and stabili]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[Sobek Metallographic Tool-Makers Microscope]]></title><link><![CDATA[https://sobek.en.ec21.com/Sobek-Metallographic-Tool-Makers-Microscope--10029761_10670633.html]]></link><description><![CDATA[，50Hz , 0.5KW
envirment requiry
temperature range：22&amp;plusmn;2℃，humidity range：30%-70%
optional parts
100X lens, Dark-field, polarized, DIC(differential interference contrast)
]]></description><pubDate><![CDATA[20180228]]></pubDate></item>
<item>
<title><![CDATA[Portable Digital Density Meter  DA-130N]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Portable-Digital-Density-Meter--8755028_8755108.html]]></link><description><![CDATA[Precision
&amp;plusmn;0.001 g/cm3
Resolution
0.0001 g/cm3
Temperature range
0 to 40&amp;deg;C
Storage temperature
-20 to 70&amp;deg;C
Display content
Density, temperature compensated density, specific gravity, t]]></description><pubDate><![CDATA[20140216]]></pubDate></item>
<item>
<title><![CDATA[DX Hall Effect Measurement System for Laboratory Studying Electrical Properties of Semiconductor]]></title><link><![CDATA[https://jackietsui.en.ec21.com/DX-Hall-Effect-Measurement-System--8508233_11795103.html]]></link><description><![CDATA[precision constant current source, high precision voltmeter, Hall effect sample holder, high and low-temperature controller, standard sample, and system software.
Refer to https://www.dexinmag.com/ha]]></description><pubDate><![CDATA[20230522]]></pubDate></item>
<item>
<title><![CDATA[High Precision CCD Spectroradiometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High-Precision-CCD-Spectroradiometer--9657760_11802779.html]]></link><description><![CDATA[Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP-Linear-DC-Power-Supply--9605857_9605884.html]]></link><description><![CDATA[temperature changes) 
Load regulation(load 0~100%): &amp;le;0.3% of the rated value (output voltage change ratio due to output current change from 0 to rated value)
3. Accuracy (C.C.)
Line regulation(361]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Wireless Control Pipeline Crawler]]></title><link><![CDATA[https://ndtchina.en.ec21.com/Wireless-Control-Pipeline-Crawler--6581053_6558183.html]]></link><description><![CDATA[precision
&amp;plusmn;5mm
&amp;plusmn;10mm
&amp;plusmn;10mm
Battery
120V/7AH
120V/12AH
120V/17AH
Working temperature
-15℃-65℃
-15℃-65℃
-15℃-65℃
Remark: By pre-request this series machine can be speci]]></description><pubDate><![CDATA[20140520]]></pubDate></item>

</channel>
</rss>