<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - x 100]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/x-100--2717/1/x 100.html]]></link><item>
<title><![CDATA[Quartz Cuvettes 2mm QS-2]]></title><link><![CDATA[https://yxcuvettes.en.ec21.com/Quartz-Cuvettes-2mm-QS-2--687322_12029893.html]]></link><description><![CDATA[Quartz cuvettes 2mm QS-2
External size: Height 45mm x 12.50mm x 4.50mm 
Pathlength 2.0mm, we supply from 1mm to 100mm,pls see below picture
Polished windows:2
Material type: Synthetic high purity qua]]></description><pubDate><![CDATA[20260416]]></pubDate></item>
<item>
<title><![CDATA[Flir C5 - Compact Thermal Camera with Wi-Fi]]></title><link><![CDATA[https://toolshed.en.ec21.com/Flir-C5-Compact--12045274_12045319.html]]></link><description><![CDATA[C5 Compact Professional Thermal Camera w/MSX and WiFi 160 x 120 Resolution/9Hz
Quickly find hidden faults and reduce diagnostic time
160 x 120 thermal resolution
5 megapixel visual camera
3.5 inch bu]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke-TIX580-Infrared-Camera--11790575_11793442.html]]></link><description><![CDATA[x, 4x, and 8xPre-calibrated Lenseswide angle, 2x telephoto, 4x telephoto and 25 micron/macro Temperature measurementTemperature measurement range (not calibrated below -10 °C)-20 °C to 1000 °C (-4]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New-Fluke-TI480-PRO-60HZ--11927627_11927630.html]]></link><description><![CDATA[x 480 SensorThermal Sensitivity50 mK (NETD)Temperature Range Max1832 FTemperature Range Min-14 FImage Frequency60 HzField of View34 x 24 DegreesScreen Size3.5 INIR/Overlay Fusion ImageYesVideo Output]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[Train Station Platform Ruler /Standard Platform Gauge]]></title><link><![CDATA[https://420621199211083365.en.ec21.com/Train-Station-Platform-Ruler--12025008_12025013.html]]></link><description><![CDATA[Key attributesOther attributesPlace of OriginHubei, ChinaTypeOtherMaterialalumuniumDimensions (L x W x H) (mm)1700*20*100mmBrand NameLinkageProduct namerail platform gaugeRuler body lengthcustomizema]]></description><pubDate><![CDATA[20241116]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three-box-High-and-Low--11943432_12023864.html]]></link><description><![CDATA[x 275mm or 395 x 395mm (effective field of view)Outer case materialHigh quality A3 steel plate electrostatic sprayingInner box materialImported high-grade stainless steel SUS304Insulation materialRig]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[Surface Roughness Gauge]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Surface-Roughness-Gauge--11973711_11973717.html]]></link><description><![CDATA[x 64 OLED dot matrix display, digital / graphic display; highlight no perspective;
● Display information rich, intuitive, can display all the parameters and graphics;
● Compatible with ISO, DIN, ]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[2 Axis 2 Frame POD Multiple Spectral Electro Optic Camera Sensor 4.5kg]]></title><link><![CDATA[https://leadir.en.ec21.com/2-Axis-2-Frame-POD--11958808_11958803.html]]></link><description><![CDATA[100w
Azimuth Axis working angle
Nx360°
Elevation Axis working angle
-110°~+30°
Maximum Angular Velocity
≥60°/S
Maximum Angular Acceleration
≥60°/S2
Stability Accuracy
≤100μrad
Video Inter]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[Analogue Rail Offset Scale Ruler]]></title><link><![CDATA[https://420625199907014021.en.ec21.com/Analogue-Rail-Offset-Scale-Ruler--11946179_11946282.html]]></link><description><![CDATA[工作边 直股铁路 以及 封闭铁路 工作边缘。 
规格
模型Lg-zjc类型横尺物质的铝合金尺寸(升x宽x高)(毫米)1710*35*40测量范围100-1400mm指示错误≤± 0.4mm
]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[Directional Portable X Ray Flaw Detector NDT Machine]]></title><link><![CDATA[https://zyhjane00.en.ec21.com/Directional-Portable-X-Ray-Flaw--9951897_9951948.html]]></link><description><![CDATA[IGBT control and sillicon control can be selected according to customer&apos;s test needs. 
qualified x ray tube and controlelr garanteed the machine&apos;s life span. 
Model
Output
Voltage (kv)
input (kw)
Foc]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke-754-Documenting-Process-Calibrator--11329183_11550830.html]]></link><description><![CDATA[100.000 mV0.02% + 0.005 mV0.03% + 0.005 mV3.00000 V0.02% + 0.00005 V0.03% + 0.00005 V30.0000 V0.02% + 0.0005 V0.03% + 0.0005 V300.00 V0.05% + 0.05 V0.07% + 0.05 VVoltage AC3.000 V (40 Hz to 500 Hz) /]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD61 6-DOF Motion Simulator Test System Simulation Table]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD61-6-DOF-Motion-Simulator--11098426_11099478.html]]></link><description><![CDATA[X, Y, Z, α, β, γ), so various space motion attitudes can be simulated.
It is widely applied as testing or training simulators in the field
of aircraft, vessel, helicopters taking off and landing, ]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Gap Projector Equipment / Charpy Impact Test Gap Projector (CST-50)]]></title><link><![CDATA[https://astmtester123.en.ec21.com/Gap-Projector-Equipment--9999942_10000105.html]]></link><description><![CDATA[X
Magnification of the object lens: 2.5X
Magnification of the objective lens for projection: 20X
Illuminant (Tungsten-halogen lamp): 12V 100W
Outline size: 515*224*603mm
Weight: 18Kg
Supply power: 22]]></description><pubDate><![CDATA[20190815]]></pubDate></item>
<item>
<title><![CDATA[CST-50 Lab Usage Gap Projector for Impact Specimen]]></title><link><![CDATA[https://lgtester789.en.ec21.com/CST-50-Lab-Usage-Gap--10000312_10017107.html]]></link><description><![CDATA[X
Magnification of the object lens: 2.5X
Magnification of the objective lens for projection: 20X
Illuminant (Tungsten-halogen lamp): 12V 100W
Outline size: 515*224*603mm
Weight: 18Kg
Supply power: 22]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[SOBEKK E300 Manual Video Measuring Machine]]></title><link><![CDATA[https://sobek.en.ec21.com/SOBEKK-E300-Manual-Video-Measuring--10029761_10670520.html]]></link><description><![CDATA[100*200
300*200*200
400*300*200
500*400*200
Machine size(mm)
750*1300*1500
750*1300*1500
900*1400*1500
1100*1125*1650
Weight（kg）
300
300
400
530
Max. load（kg）
20
25
25
30
Accuracy of X-Y axis]]></description><pubDate><![CDATA[20210222]]></pubDate></item>
<item>
<title><![CDATA[High Precision CCD Spectroradiometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High-Precision-CCD-Spectroradiometer--9657760_11802779.html]]></link><description><![CDATA[x, Δy): ±0.002 (under Standard A Lamp)• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)• Luminous Flux]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LITE800 Industrial SLA 3D Printer]]></title><link><![CDATA[https://uniontech3d.en.ec21.com/LITE800-Industrial-SLA-3D-Printer--11706631_11807017.html]]></link><description><![CDATA[100 mm: ±0.15 mm
Dimension ≥100 mm: ±0.15% x Dimension
Layer Thickness
0.07-0.25 mm
Laser
355 nm, solid-state frequency tripled
Nd: YVO₄
Beam Focus
Dynamic &amp; Variable
Beam Size
0.12-0.8 mm
Mate]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[X8000 Series Load Modules]]></title><link><![CDATA[https://xinertel.en.ec21.com/X8000-Series-Load-Modules--10761704_10761705.html]]></link><description><![CDATA[X8004F
X8002F
Port Number
4 * 10G
2 * 10G
Port Rate
SFP+：10G
SFP+：10G
Physical
Status Indicators: Tx/Rx
Weight: 0.5kg
Size: 271mm x 35.5mm x 180mm 
Peak power requirement: 100W Max
Traffic Genera]]></description><pubDate><![CDATA[20190505]]></pubDate></item>
<item>
<title><![CDATA[Transformer Variable Ratio of Entire Inspection Test]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/Transformer-Variable-Ratio-of-Entire--10586983_10714599.html]]></link><description><![CDATA[X, Y, Z, x, y, z, a ,, b ,, c ,, x ,, y ,, z, is used in verifying the accuracy of the standard transformation PT and the standard three- In addition, there is no other purpose, but not short of each]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[New NDT Systems Raptor Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New-NDT-Systems-Raptor-Flaw--11801594_11801615.html]]></link><description><![CDATA[100%Audible and visual alarm modes, thickness high, low or high/low. Amplitude /- levelProgrammable user setupsAuto 80% gain controlScreen freeze mode, freeze and saveSelectable resolutionWindows bas]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Portable CCD LED Colorimeter Spectroradiometer]]></title><link><![CDATA[https://15317383997.en.ec21.com/Portable-CCD-LED-Colorimeter-Spectroradiometer--11812738_11812747.html]]></link><description><![CDATA[x, Δy): ±0.005• Correlated color temperature CCT: 1, 000K ~ 100, 000K (±0.6%)• Illuminance range: 5~200,000lx• LCD screen: 5inch high definition IPS capacitive touch screen and resolution is]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[GF1061 Portable CT PT Analyzer Is Mainly Used for Field or Lab Testing, It Can Finish the Measuremen]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/GF1061-Portable-CT-PT-Analyzer--10658146_10658147.html]]></link><description><![CDATA[1000-4-2 /3 /4 /6
Mechanical parameters　
Overall dimension (L x W x H) (mm)
280 x 250 x 160
Weight (kg)
&amp;le;4
Environmental conditions　
Relative humidity
Relative humidity 5%-95% not condensing
O]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[Industrial Endoscope]]></title><link><![CDATA[https://duraer.en.ec21.com/Industrial-Endoscope--10929436_10922621.html]]></link><description><![CDATA[x V768 (Pixel)Power SupplyBattery: 7.4 V, Approx.240-minute operating timeAC power: 100 V to 240 V, 50/60 Hz (with supplied AC adaptor)USB ConnectorVersion 2.0 standardsRecording Management Functions]]></description><pubDate><![CDATA[20190719]]></pubDate></item>
<item>
<title><![CDATA[SALE Flir T600-25 Thermal Imaging Camera]]></title><link><![CDATA[https://indotechequipment.en.ec21.com/SALE-Flir-T600-25-Thermal--11324807_11539194.html]]></link><description><![CDATA[Includes :
1 - Thermal Imaging Camera, MSX Enhancement, 480 x 360 Resolution, -40 - 1,202°F Range, 30 Hz Framerate, 4x Continuous Zoom
1 - 25° Lens
1 - SD Memory Card
1 - 100-260V AC Adaptor/Charge]]></description><pubDate><![CDATA[20220303]]></pubDate></item>
<item>
<title><![CDATA[Hitachi X-MET 8000 Opt Handheld Analyzer]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/Hitachi-X-MET-8000-Opt--11834264_11834269.html]]></link><description><![CDATA[Specification X-MET 8000 Optimum :X-ray tube : 40kV or 50kVX-ray tube filters: 6 position filter changerDetector: Large area SDDMax. sample temperature : 100ºC or 400ºC with HERO™ heat resistant ]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[ICONE2]]></title><link><![CDATA[https://kobistq.en.ec21.com/ICONE2--1_11135288.html]]></link><description><![CDATA[100 X 100 X 50 mm thick, in the horizontal and vertical orientation. 
Load Cell - Mass measurements are conducted via a strain gauge load cell with an accuracy of 0.1 g and a total weight range of 2 ]]></description><pubDate><![CDATA[20200511]]></pubDate></item>
<item>
<title><![CDATA[CCD Spectroradiometer Integrating Sphere Compact System]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/CCD-Spectroradiometer-Integrating-Sphere-Compact--11882688_11882692.html]]></link><description><![CDATA[x, Δy): ±0.003 (under Standard A Lamp)• Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: ±0.5%• Color Rendering Index Range: 0~100.0, Accuracy: ± (0.3%rd±0.3)• Photometric l]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[NEW Digital Handheld Salt Tester DMT-20]]></title><link><![CDATA[https://dymeter.en.ec21.com/NEW-Digital-Handheld-Salt-Tester--1223564_3312029.html]]></link><description><![CDATA[x 30w x 195d mm 
SPECIFICATIONS FOR SALT 
Conductivity measurement method 
Range 0.0 - 5.0 
Resolution 0.1
Sample temperature range 0-70&amp;deg;C 
SPECIFICATIONS FOR THERMOMETER 
Range 0 - 100&amp;deg;C 
Ac]]></description><pubDate><![CDATA[20180303]]></pubDate></item>
<item>
<title><![CDATA[Digital Salt Checks]]></title><link><![CDATA[https://gwonhitech.en.ec21.com/Digital-Salt-Checks--193863_4049052.html]]></link><description><![CDATA[100
7. Power Source
Battery 1.5V(AAA) x 3EA
8. Dimensions
210(L) x 45(W) x 25(H)mm
9. Gross Weight
Approx. 100g(Net Weight)
Digital Salt Checks - Manual
1) The names of each part
2) Before Measuremen]]></description><pubDate><![CDATA[20190703]]></pubDate></item>
<item>
<title><![CDATA[Manifold Filtration Device]]></title><link><![CDATA[https://shenzhilin.en.ec21.com/Manifold-Filtration-Device--11772711_6504599.html]]></link><description><![CDATA[100, 150, 200, 250ml with annular scale line
Membrane Diameter: 47mm and 50mm
Effective filtration area: 12.5 cm2
W x H: 105mmx135mm
Material of Funnel: PP and Stainless Steel
Material of Support: St]]></description><pubDate><![CDATA[20230721]]></pubDate></item>
<item>
<title><![CDATA[AST900  Digital Pressure and Temeprature Indicator]]></title><link><![CDATA[https://apexsensor.en.ec21.com/AST900-Digital-Pressure-and--11311676_11311677.html]]></link><description><![CDATA[supply
85-265VAC 50Hz-60Hz
Size
AST900: 96mm x 96mm x 100 mm (W x H x D)
AST901: 96mm×48mm×100 mm (W x H x D)
AST902: 48mm×96mm×100 mm (W x H x D)
Weight
approximately 400g/200g/200g
]]></description><pubDate><![CDATA[20230623]]></pubDate></item>
<item>
<title><![CDATA[ST3007 Digital Measuring Projector]]></title><link><![CDATA[https://satatech.en.ec21.com/ST3007-Digital-Measuring-Projector--3839683_6297211.html]]></link><description><![CDATA[ST3007 DIGITAL MEASURING PROJECTOR (Reverse image)
Technical Parameters:
Worktable
Metal dimension (mm) : 260&amp;times;152mm
Glass dimension (mm): 125*100mm
X-axis travel: 75mm
Y-axis travel: 50mm
Z-axi]]></description><pubDate><![CDATA[20180729]]></pubDate></item>
<item>
<title><![CDATA[Model CLG-160 Aluminium Wheel RTR System]]></title><link><![CDATA[https://ndtchina.en.ec21.com/Model-CLG-160-Aluminium-Wheel--6581053_6161286.html]]></link><description><![CDATA[100% testing.
l PLC control and multi-axes mechanical hand .
l Low clarity problem has also been overcome with image&amp;rsquo;s enlargement by zoom lens.
l Optimized electronic components providing reli]]></description><pubDate><![CDATA[20140520]]></pubDate></item>
<item>
<title><![CDATA[100W LED High-power Light Source  LED Lamp LED Light]]></title><link><![CDATA[https://aulight2021.en.ec21.com/100W-LED-High-power-Light--11446883_11446892.html]]></link><description><![CDATA[100mm
Irradiation unevenness
&lt;2% 
Optical power density
&lt;300mw/cm2（CEL-NP2000 Tested）
white light LED（400-780nm）&lt;500mw/cm2
LED bulb life
&lt;10000 hours（365nm&lt;1000hours）
Standard Configurati]]></description><pubDate><![CDATA[20230406]]></pubDate></item>
<item>
<title><![CDATA[Ponovo PW636i Protection Relay Test System for Different Types of Protection Relays]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo-PW636i-Protection-Relay-Test--7403753_7404064.html]]></link><description><![CDATA[x 0~32A
Power(typical)
6x 450VA at 32A
3 x 800VA at 64A
Accuracy (typical)
&lt;0.05% rd+0.02% rg. at 0~32A
Voltage
Range
4 x 0~300V
Power(typical)
4x 75VA at 300V
3 x 100VA at 300V
Accuracy (typical)
&lt;0]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Volumetric Karl Fischer Titration MKV-710B]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Volumetric-Karl-Fischer-Titration-MKV--8755027_8755082.html]]></link><description><![CDATA[100 samples
GLP conformance
Registration of operator /Record of check results / Record of factor measurement / Management of conduction time
External I/O
RS-232C port x2 : 
for Dot matrix printer , E]]></description><pubDate><![CDATA[20170120]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Window Tint Meter WTM-1100 Light Transmission Meter]]></title><link><![CDATA[https://105landtek.en.ec21.com/Hot-Sale-Window-Tint-Meter--11797706_11797708.html]]></link><description><![CDATA[x 1.5 V AAA Size (UM-4) Battery
Dimensions:Unit: 126 x 65 x 27 mm (5.0 x 2.6 x 1.1 inch)
Sensor: 125 x 38 x 38 mm
Weight:100 g (Not Including Batteries)
Accessories:
Standard Accessories
1. Main Unit]]></description><pubDate><![CDATA[20231125]]></pubDate></item>
<item>
<title><![CDATA[VICIMETER Megga Resistance Testing VC60B+ Insulation Tester]]></title><link><![CDATA[https://vicimeter.en.ec21.com/VICIMETER-Megga-Resistance-Testing-VC60B--11555545_8944178.html]]></link><description><![CDATA[100kΩ
500V±10% test voltage
0~200MΩ
100kΩ
1000V±10% test voltage
0~2GΩ
1MΩ
Resistance
0~2kΩ
±(1.0%+5)
1Ω
DCV
0~1000V
1V
ACV
0~750V
±(1.5%+5)
1V
Special function
VC60B+
Continuity alarm
Les]]></description><pubDate><![CDATA[20220419]]></pubDate></item>

</channel>
</rss>