<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 1 10 scale]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/1_10_scale--2717/1/1 10 scale.html]]></link><item>
<title><![CDATA[Fluke II500 - Acoustic Imager (2-52 Khz)]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_II500_Acoustic_Imager_2--12045274_12045275.html]]></link><description><![CDATA[Fluke ii500
Enables technicians see sound as they scan hoses, fittings, and connections for leaksDetection range: Up to 164 feet (50 meters)LeakQ mode: Scale (1-10)This model does not show leak rate ]]></description><pubDate><![CDATA[20250328]]></pubDate></item>
<item>
<title><![CDATA[Valid Magnetics Air Cooled / Blower Hysteresis Dynamometer for Motor Test, Torque, Speed and Power]]></title><link><![CDATA[https://validmagnetics.en.ec21.com/Valid_Magnetics_Air_Cooled_Blower--8979451_8979479.html]]></link><description><![CDATA[1% full scale, depending on size and system configuration. Fine adjustment for optimization can be done with the support of our own invented dynamotmeter controller. It has high cost/performance rati]]></description><pubDate><![CDATA[20250205]]></pubDate></item>
<item>
<title><![CDATA[Frog Vertical Wear Gauge]]></title><link><![CDATA[https://420621199211083365.en.ec21.com/Frog_Vertical_Wear_Gauge--12024098_12024113.html]]></link><description><![CDATA[range
0-40mm
Main ruler scale
0mm-380mm
Score value
0.01mm
Accuracy
1mm
Working temperature
-10°C-+40°C
APPLICATION
Front of frog vertical wear gauge
Back of frog vertical wear gauge
]]></description><pubDate><![CDATA[20241113]]></pubDate></item>
<item>
<title><![CDATA[New BEL M124A Laboratory Balance - 120g - 0.1mg]]></title><link><![CDATA[https://dentalclic.en.ec21.com/New_BEL_M124A_Laboratory_Balance--12021072_12021074.html]]></link><description><![CDATA[1 mg (10-4 g)
Maximum capacity: 120 g
Repeatability: 0.1 mg
Linearity: 0.3 mg
Tray dimensions: diameter 80 mm
Chamber dimensions (L x D x H): 162 x 171 x 225mm
Net weight approx. 6.3 kg
Scale dimensi]]></description><pubDate><![CDATA[20241028]]></pubDate></item>
<item>
<title><![CDATA[Portable Hardness Tester]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Portable_Hardness_Tester--11973711_12009824.html]]></link><description><![CDATA[170-960) HLD, (17-68.5) HRC, (19-651) HB, (80-976) HV, (30-100) HS, (59-85) HRA, (13-100)HRB 
● Measuring direction: 360° ( ↓ ↖ ↗ ↘ ↙ → ← ↑ )
● Hardness Scale: HL, HB, HRB, HRC, ]]></description><pubDate><![CDATA[20240925]]></pubDate></item>
<item>
<title><![CDATA[NDJ-1C Hot Melt Adhesives Brookfield Viscosity Meter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_1C_Hot_Melt_Adhesives--11144324_11144465.html]]></link><description><![CDATA[1999 T Determination of melt viscosity of hot melt adhesives
Specification
Model No
NDJ-1C
Display
Backlit LCD, digital display
Speed (r/min)
0.5 / 1 / 2 / 5 / 10 / 20 / 50
Rotor
21#,27#,28#,29#
Meas]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Digital Screen Tension Tester]]></title><link><![CDATA[https://ame7788.en.ec21.com/Digital_Screen_Tension_Tester--9661329_9762827.html]]></link><description><![CDATA[1 
Operating Environment
Temperature: 0 ~ 40 ℃ Humidity: 10 ~ 90 %RH
Power Supply
4 x 1.5 V AAA Size (UM-4) Battery
Demensions
175 x 95 x 40 mm
Weight
490 g (Not Including Batteries)
Printing Task ]]></description><pubDate><![CDATA[20240529]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 IPX1-4 Comprehensive Waterproof Test Chamber Integrated with Drip Box and Oscillating Tubes]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60529_IPX1_4_Comprehensive_Waterproof--11940576_11940977.html]]></link><description><![CDATA[1800 on either side of the vertical, and time for one complete oscillation (2*3600) being about 12s. The duration of the test is 10min. 
For IPX1 and IPX2 tests, the aperture of nozzle is Φ0.4mm, di]]></description><pubDate><![CDATA[20240522]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[10 hour uninterrupted use. Includes gas gauge.Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.Delivered with DPC/Track Sample software.Compatible with many Asset Manag]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Horizontal Vertical Combustion Tester]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Horizontal_Vertical_Combustion_Tester--11683816_11683819.html]]></link><description><![CDATA[1. Bunsen burner cap: inner diameter 9.5mm±0.3mm from the air inlet to the length of about 100mm±10mm;
2. Burner Angle: 0~45°(manual adjustment, with scale);
3. Ignition bedding plate: standard me]]></description><pubDate><![CDATA[20221130]]></pubDate></item>
<item>
<title><![CDATA[Crude Oil Water Content Meter]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Crude_Oil_Water_Content_Meter--11718430_11856617.html]]></link><description><![CDATA[1. Applicable standard: GB/T8929
2. Temperature control method: potentiometer to adjust temperature rise
3. Distillation flask: 1000ml
4. Water receiver: 5ml, small scale 0.05ml.
5. Condenser: 400mm]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[TJH-2C Parallel Beam Load Cell]]></title><link><![CDATA[https://tgloadcells.en.ec21.com/TJH_2C_Parallel_Beam_Load--11543401_11592317.html]]></link><description><![CDATA[scales, electronic belt scales, batching scales, etc.
Specifications of TJH-2C Parallel Beam Load Cell
Technical Parameter
Rated Load
0.5~10 kN
Comprehensive Precision
0.02~0.05% FS
Sensitivity
2.0 m]]></description><pubDate><![CDATA[20220624]]></pubDate></item>
<item>
<title><![CDATA[MOSIP Certified Fingerprint Scanner]]></title><link><![CDATA[https://miaxis2024.en.ec21.com/MOSIP_Certified_Fingerprint_Scanner--11895938_11895942.html]]></link><description><![CDATA[1 Device, SBI 2.0
Compliance
FBI-PIV, MOSIP L1, CE &amp; FCC certified
Maximum Acquisition time (Placement to Template)
&lt;3s
Grey scale
8 bit (256 levels )
Live finger detection
Yes
Platen Ingress Protect]]></description><pubDate><![CDATA[20240131]]></pubDate></item>
<item>
<title><![CDATA[CST-50 Impact Specimen U/V Notch Projector]]></title><link><![CDATA[https://wanchen123.en.ec21.com/CST_50_Impact_Specimen_U--11774583_11774608.html]]></link><description><![CDATA[scale, tolerance band, angle value and depth line, which can accurately read the notch error. It can be also customized to meet customer’s requirements.
Features
1) It is in accordance with the sta]]></description><pubDate><![CDATA[20230529]]></pubDate></item>
<item>
<title><![CDATA[ICONE2]]></title><link><![CDATA[https://kobistq.en.ec21.com/ICONE2--1_11135288.html]]></link><description><![CDATA[1980&apos;s workers at NIST (formerly NBS), in the USA, decided to produce an improved bench scale heat release test which would overcome the deficiencies of existing small scale heat release tests which ]]></description><pubDate><![CDATA[20200511]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 Waterproof Testing Machine IPX12 Vertical Rain Drip Box]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC60529_Waterproof_Testing_Machine_IPX12--11405200_11418229.html]]></link><description><![CDATA[1 waterproof testing equipment request the dripping water (vertically falling drops) shall have no harmful effect. Test duration: 10 minutes, equivalent to 1 mm / minute.
The IPX2 waterproof testing ]]></description><pubDate><![CDATA[20210722]]></pubDate></item>
<item>
<title><![CDATA[CMT Series Electronic Universal Testing Machine 100kg]]></title><link><![CDATA[https://astmtester123.en.ec21.com/CMT_Series_Electronic_Universal_Testing--9999781_10000193.html]]></link><description><![CDATA[1)Measurement parameters
1. Maximum test force: 1kN
2. Accuracy class: 0.5
3. Measuring range of test force: 0.4%~100%FS full scale
4. Indicating error of test force: within &amp;plusmn;0.5% of indicatin]]></description><pubDate><![CDATA[20180810]]></pubDate></item>
<item>
<title><![CDATA[LDS-50A 50kN Metal Material Universal Tensile Compression Bending and Shearing Testing Machine]]></title><link><![CDATA[https://lgtester789.en.ec21.com/LDS_50A_50kN_Metal_Material--10000302_10012238.html]]></link><description><![CDATA[1) Maximum test force of transducer: 50kN
2)The scope of the accurate measurement of test force: 2%-100% of full scale;
3) Accuracy of test force measurement: ± 1%;
4) Accuracy of displacement measu]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[ST3007 Digital Measuring Projector]]></title><link><![CDATA[https://satatech.en.ec21.com/ST3007_Digital_Measuring_Projector--3839683_6297211.html]]></link><description><![CDATA[12, used range &gt; &amp;Oslash;300(with scale like a asterisk)
projection rotate range: 0~3600
rotate angle digital display resolution: 1&amp;rsquo;or 0.01&amp;ordm;
Objective
Magnify multiple:
10X (standard)
20X(]]></description><pubDate><![CDATA[20180729]]></pubDate></item>
<item>
<title><![CDATA[JB-500B Impact Testing Machine]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/JB_500B_Impact_Testing_Machine--6651349_6678633.html]]></link><description><![CDATA[10 × 10mm. It mainly used for ferrous metal of toughness, particularly the testing of iron, steel and its alloys. 
The use of the difference of potential energy between prior impact and the remainin]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[X6000 Series Load Modules]]></title><link><![CDATA[https://xinertel.en.ec21.com/X6000_Series_Load_Modules--10761704_10761708.html]]></link><description><![CDATA[16 gigabit COMBO ports and support Cross-chassis synchronizing to provide large-scale protocol emulation, performance test and mass traffic stress test of Layer 2-7 network device.
X6000 series modul]]></description><pubDate><![CDATA[20190419]]></pubDate></item>
<item>
<title><![CDATA[NAVLF Ultra-low Frequency High Voltage Generator]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/NAVLF_Ultra_low_Frequency_High--10586964_10725175.html]]></link><description><![CDATA[scale 
5, The voltage positive and negative peak error: &amp;le; 3% of full scale 
6, The voltage waveform distortion: &amp;le; 5% 
7,Usage conditions : indoor, outdoor; 
Temperature: -10 ℃ ∽ +40 ℃; 
H]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Dyeing Rubbing Tester JIS Standard]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Dyeing_Rubbing_Tester_JIS_Standard--5441143_9767602.html]]></link><description><![CDATA[scale to evaluate dyeing friction fastness levels. 
It can also be used to do friction test of organic flux. It has intelligent power failure recovery function. 
TECHNICAL PARAMETERS 
1.Friction Spee]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[H-Sorb 2600 High Pressure Gas Sorption Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/H_Sorb_2600_High_Pressure--7277235_7277204.html]]></link><description><![CDATA[scale), long-duration usage stability is 0.025% of F.S.
Ultimate Vacuum: 4x10-2 Pa (3x10-4 Torr), molecular pump system (1x10-6 Pa) is optional
Adsorbate Gas: high purity nitrogen, CO2 or others (Ar,]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Characteristics of A Fast Ammonia Nitrogen Analyzer]]></title><link><![CDATA[https://kobebean24.en.ec21.com/Characteristics_of_A_Fast_Ammonia--11076331_11855967.html]]></link><description><![CDATA[10. Curve correction, supporting automatic curve correction and automatic saving;11. Memory curve, 5 manufacturer curves, 195 extension curves, a total of 200;12. Curve customization: customize high-]]></description><pubDate><![CDATA[20231018]]></pubDate></item>
<item>
<title><![CDATA[IEC-60156 Transformer Oil Breakdwon Voltage Tester, Insulating Oil BDV/Dielectric Strength Test Kit]]></title><link><![CDATA[https://transformeroilfilter.en.ec21.com/IEC_60156_Transformer_Oil_Breakdwon--10553644_10728884.html]]></link><description><![CDATA[1% of full scale + 2 digits) Resolution: 0.1KV 
10. Temperature measurement. 
11. Measurement range: 0&amp;deg;C to 70&amp;deg;C, or better 
12. Temperature resolution: 1&amp;deg;C, or better 
13. Operating temp]]></description><pubDate><![CDATA[20180515]]></pubDate></item>
<item>
<title><![CDATA[Standard Portable Pendulum Skid Resistance and Friction Tester( Skid Tester for Civil)]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/Standard_Portable_Pendulum_Skid_Resistance--10976325_10976545.html]]></link><description><![CDATA[10 × 210
Standard delivery:48-B0192 portable skid resistance and friction tester, adjustable in heightB0192/1 sturdy case with dense foam inserts giving excellent protectionB0192/2 F&apos; Scale Built in]]></description><pubDate><![CDATA[20230530]]></pubDate></item>
<item>
<title><![CDATA[Fluxmeters Electromagnetic Flux Meter Price Magnetic Flux Flow Density Meter]]></title><link><![CDATA[https://jackietsui.en.ec21.com/Fluxmeters_Electromagnetic_Flux_Meter_Price--8508233_11795040.html]]></link><description><![CDATA[1k ohm, 10k ohm, 100k ohm, 1000k ohm;
3. Power supply: AC 50Hz, 220V0.5A;
4. High precision, full-scale accuracy reaches ± 0.1%, resolution error range is ± 1/30000;
5. Drift degree: very low integ]]></description><pubDate><![CDATA[20230522]]></pubDate></item>

</channel>
</rss>