<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 1000 w]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/1000_w--2717/1/1000 w.html]]></link><item>
<title><![CDATA[Fluke 3540 FC KIT Three-Phase Power Monitor]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_3540_FC_KIT_Three--12045274_12045343.html]]></link><description><![CDATA[1000 V CAT II/600 V CAT III/300 V CAT IV)Storage Altitude39,000&apos; (12,000 m)IP RatingIEC 60529:IP50, in connected condition with protection caps in placeVibrationMIL-T-28800E, Type 3, Class III, Style]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[1000 °C (-4 °F to 1832 °F)Accuracy±2 °C or 2% (at 25 °C nominal, whichever is greater)Thermal sensitivity (NETD)*≤ 0.05 °C at 30 °C target temp (50 mK)On-screen emissivity correctionYes (bo]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[1000 °C (-14 °F to 1832 °F)Accuracy± 2 °C or 2 % (at 25 °C nominal, whichever is greater)On-screen emissivity correctionYes (both value and table)On-screen reflected background temperature comp]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[Door Closer Durability Test Machine]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Door_Closer_Durability_Test_Machine--11987076_11989163.html]]></link><description><![CDATA[1000（W）×40（T），约30kg（最大160）
5. 安装方式：标准臂平行臂表面贴装，.
6、 测力计：500N（50kg），读数精度1.5%;
7. 角度传感器：精度1%，分辨率0.1%]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Ultrasonic_Flaw_Detector--11973711_11973715.html]]></link><description><![CDATA[1000 - 16000
Vertical Linearity Error
≤3%
Horizontal Linearity Error
≤0.1%
Sensitivity Leavings
≥62dB
Dynamic range
≥32dB
Resolving Power
≥36dB
Gain (dB)
0 - 110
Measurement Mode
Single、D]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[Lab Stretching Machine| Laboratory Stretching Machine| Film Stretching Machine]]></title><link><![CDATA[https://potopyangliu.en.ec21.com/Lab_Stretching_Machine_Laboratory_Stretching--11956821_11958098.html]]></link><description><![CDATA[temperature accuracy
±3℃
Stretching motor power
3.5kW
Working voltage
3φ380VAC±10%，1φ220VAC±10%，50Hz
Rated power 
Approx.22kW
L x W x H
2040mm×1050mm×1680mm
Weight
Approx.1000kg
]]></description><pubDate><![CDATA[20240627]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-2 Electrostatic Discharge Generator with 20KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_2_Electrostatic_Discharge--11944039_11946383.html]]></link><description><![CDATA[IEC61000-4-2 Electrostatic Discharge Generator with 20KV Output Voltage
Introduction:
ESD simulator (ESD gun) is completely meet the requirements of IEC61000-4-2 and GB/T17626.2. The ESD generator is]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[GS-SW6401725-80-U Scientific Deep-cooled SWIR Camera]]></title><link><![CDATA[https://gatherstar.en.ec21.com/GS_SW6401725_80_U_Scientific--11943440_11943922.html]]></link><description><![CDATA[1000nm-1600nm）
C ool ed temperature
-10℃—-80℃（Freely selectable）
F ull well capacity 
118Ke- High Gain
1.9Me- Low Gain
Pixel operability 
＞99.5%
Response non - linearity 
＜2%
Cooler t]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[VC5000A Power Quality Analyzer]]></title><link><![CDATA[https://cqsellbest.en.ec21.com/VC5000A_Power_Quality_Analyzer--11925671_11925688.html]]></link><description><![CDATA[1000V / 0.1 / ±(0.5%+5dgt)True RMS Line Voltage1.0-2000V / 0.1 / ±(0.5%+5dgt)DC Voltage1.0-1000V / 0.1 / ±(1.0%+5dgt)True RMS Current10mA-9000A / 1mA / ±(0.5%+5dgt)Phase Voltage Peak1.0-1414V / 0]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[Fully Automatic Insertion and Extraction Force Tester]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Fully_Automatic_Insertion_and_Extraction--11683816_11853603.html]]></link><description><![CDATA[Product DescriptionTechnical specifications：
1. Maximum test force: 1000N, 500N, 200N, 10N (optional);
2. The sampling frequency is 100Hz;
3. Accurate measurement: Class 0.5;
4. Minimum resolution:]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/3kW_3.5kW_4kW_5kW_6kW--11807084_11807114.html]]></link><description><![CDATA[1000WLoad Steps1000W,1000W,1000WLoad accuracy (per step)±2%Insulation classFWorking modeContinuous workCooling modeForced air cooling,horizontal air discharge,2 fans,2*186CFM=372CFMControl modeMCB (]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Sonic Nozzle Gas Meter Test Bench]]></title><link><![CDATA[https://royreal.en.ec21.com/Sonic_Nozzle_Gas_Meter_Test--11907986_11908002.html]]></link><description><![CDATA[1000～1000)Pa
Leak Test
(0～100) kPa
Environment Temperature
(20±2)℃
Humidity Test
45%～70%
Power Supply
380V±38V AC 50Hz
Test Bench Size
L × W × H (4 Workstations) 1450 × 720 × 1765 mm
Op]]></description><pubDate><![CDATA[20240301]]></pubDate></item>
<item>
<title><![CDATA[Automatic Kinematic Viscometer]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Automatic_Kinematic_Viscometer--11718430_11856620.html]]></link><description><![CDATA[1000 sets of test results
10.Working power supply: AC220V+10%, 50Hz 
11.Machine power 1500w
12.Instrument size: 370*360*650
Weight: 50KG
Main Feature s 
1. 
Using microcontroller control, color touch]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/Used_Olympus_Nortec_600D_Eddy--11801594_11801596.html]]></link><description><![CDATA[W × H, diagonal)117.4 mm × 88.7 mm, 146.3 mm
Display typeFull VGA (640 × 480 pixels) color, transflective LCD (liquid crystal display).
Screen modesNormal or Full screen, 8 color schemes.
Grids an]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Solar Simulator Xenon Lamp Light Source Solar Cell IV Test]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Solar_Simulator_Xenon_Lamp_Light--11446867_11446868.html]]></link><description><![CDATA[W, 350W, 500W high-pressure short-arc spherical xenon lamp, the formation of arc light discharge under high-frequency, high-pressure excitation. High-pressure short-arc spherical xenon lamp is a poin]]></description><pubDate><![CDATA[20240104]]></pubDate></item>
<item>
<title><![CDATA[Cold and Hot Shock Test Box / Cold and Hot Impact Tester]]></title><link><![CDATA[https://lituotest.en.ec21.com/Cold_and_Hot_Shock_Test--11372570_11372577.html]]></link><description><![CDATA[Technical parameters 1. Inner box size (W*H*D) : 500*400*400mm(80L)2. Outer box size (W*H*D) : 1480*1900*1550mm3. Temperature range :(-45ºC, -55ºC, -65ºC, -70ºC) ~ 150ºC4. Temperature range of h]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61000_4_5_Lightning_Surge--11421920_11421956.html]]></link><description><![CDATA[LSG-6K10 Lightning Surge Generator with 1.2/50us and 8/20us Waveform
Introduction:
LSG-6K10 surge generator is designed according to IEC61000-4-5 and GB/T17626.5,and completely meet the requirements ]]></description><pubDate><![CDATA[20210729]]></pubDate></item>
<item>
<title><![CDATA[VICIMETER Megga Resistance Testing VC60B+ Insulation Tester]]></title><link><![CDATA[https://vicimeter.en.ec21.com/VICIMETER_Megga_Resistance_Testing_VC60B--11555545_8944178.html]]></link><description><![CDATA[1000V±10% test voltage
0~2GΩ
1MΩ
Resistance
0~2kΩ
±(1.0%+5)
1Ω
DCV
0~1000V
1V
ACV
0~750V
±(1.5%+5)
1V
Special function
VC60B+
Continuity alarm
Less than 30Ω±10Ω
Low battery indication
Less ]]></description><pubDate><![CDATA[20220419]]></pubDate></item>
<item>
<title><![CDATA[Sobek Metallographic Tool-Makers Microscope]]></title><link><![CDATA[https://sobek.en.ec21.com/Sobek_Metallographic_Tool_Makers_Microscope--10029761_10670633.html]]></link><description><![CDATA[1000*800*980mm
Resolution
0.0001mm
Accuracy
（2+250/L) um
Repeatability accuracy
2um
X.Y move style
Manual handle
Z move style
Automatic focus(servo motor)+ Manual pulse handwheel focus(min focal di]]></description><pubDate><![CDATA[20180228]]></pubDate></item>
<item>
<title><![CDATA[JB-500S Impact Testing Machine]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/JB_500S_Impact_Testing_Machine--6651349_6678669.html]]></link><description><![CDATA[W (Main Motor)
16. Working conditions: 
1. Room temperature range is 10-35 ℃; 
2. Relative humidity is less than 85％; 
3. Non-corrosive media surrounding environment; 
4. Installed in the thickne]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[X6000 Series Load Modules]]></title><link><![CDATA[https://xinertel.en.ec21.com/X6000_Series_Load_Modules--10761704_10761708.html]]></link><description><![CDATA[1000M
SFP：100/1000M
COMBO ports
RJ45：10/100/1000M
SFP：100/1000M
COMBO ports
Physical
Status Indicators: Tx/Rx
Weight: 0.5kg
Size: 271mm x 35.5mm x 180mm 
Peak power requirement: 100W Max
Traffi]]></description><pubDate><![CDATA[20190419]]></pubDate></item>
<item>
<title><![CDATA[TN1058 Programmable Constant Temperature and Humidity Chamber]]></title><link><![CDATA[https://fulfilling.en.ec21.com/TN1058_Programmable_Constant_Temperature_and--5441143_9547151.html]]></link><description><![CDATA[1000x1000x800cm
1000x1000x1000cm
Dimension 
(LxWxH)
1200x1650x1150cm
1300x1700x1250cm
140x185x1300
165x195x1550
185x200x1750
1900x2100x1850
Power
1200W
1800W
2500W
3000W
4000W
5000W
Temp range
Low te]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Auto Tensile Tester Universal Testing Equipment]]></title><link><![CDATA[https://systester18.en.ec21.com/Auto_Tensile_Tester_Universal_Testing--10834076_10926308.html]]></link><description><![CDATA[1000mm/min.
5: Displacement accuracy: 0.005mm.
6: Sample width: 55mm. (optional)
7: Sample thickness: 5mm. (optional)
8: Power supply: AC 220V 50Hz.(optional)
9: Power consumption: 300W.(Max) 
10: Di]]></description><pubDate><![CDATA[20221214]]></pubDate></item>
<item>
<title><![CDATA[Ponovo PW466i Protective Relay Testing Equipment 6-Phase Protective Relay Test Set]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_PW466i_Protective_Relay_Testing--7403753_7403899.html]]></link><description><![CDATA[1000Hz
Transient signal
dc … 10kHz
Accuracy
0.3ppm
Phase angle
Range
0-359.9º
Accuracy (typical)
0.05º
Auxiliary DC supply
0-300V
88W at 110V, 176W at 220V, 120W at 300V
Binary input
Number
8
Typ]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Testing Equipment for Glass in Building]]></title><link><![CDATA[https://yuanchenwujin68.en.ec21.com/Testing_Equipment_for_Glass_in--11114426_11248640.html]]></link><description><![CDATA[1000mm, 5000mm, 12000mm, Customized
Automatic release and lift. Power: 220V 50Hz 580W
Supporting fixture:
a) Support Size:
350mm*350mm and 660mm*660mm (Customized)
b) Frame width 15mm
c) Steel box he]]></description><pubDate><![CDATA[20230719]]></pubDate></item>
<item>
<title><![CDATA[GF1061 Portable CT PT Analyzer Is Mainly Used for Field or Lab Testing, It Can Finish the Measuremen]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/GF1061_Portable_CT_PT_Analyzer--10658146_10658147.html]]></link><description><![CDATA[1000-4-2 /3 /4 /6
Mechanical parameters　
Overall dimension (L x W x H) (mm)
280 x 250 x 160
Weight (kg)
&amp;le;4
Environmental conditions　
Relative humidity
Relative humidity 5%-95% not condensing
O]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[Quick Thermal Conductivity Meter QTM-700/QTM-710]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Quick_Thermal_Conductivity_Meter_QTM--8755030_8755121.html]]></link><description><![CDATA[W/(m K)Measurement temperature-100-1000℃Measurement time60sec ※Sample size100×50×20 mm or more 2 pieces
※Optionally set the Measurement time.
SpecificationContentsTypePD-11NPD-13NMeasurement ]]></description><pubDate><![CDATA[20190329]]></pubDate></item>
<item>
<title><![CDATA[Electric Motor Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/Electric_Motor_Testing_Equipment--11085938_11085967.html]]></link><description><![CDATA[1000V 
±(2%×setting value+10V)
insulation resistance testing range/precision
1～500MΩ 
≤100MΩ：±(3%×setting value+0.5MΩ) ；&gt;100
MΩ：±(5%×setting value+5MΩ)
insulation resistance alar]]></description><pubDate><![CDATA[20200324]]></pubDate></item>

</channel>