<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 11 9]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/11_9--2717/1/11 9.html]]></link><item>
<title><![CDATA[Fluke TI480 PRO Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_TI480_PRO_Thermal_Imaging--12045274_12045346.html]]></link><description><![CDATA[95% non-condensingSafety: IEC 61010-1: Overvoltage category II, Pollution Degree 2Electromagnetic compatibility: IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class AAustralian RCM: IEC 61326]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[95% non-condensingSafetyIEC 61010-1: Overvoltage category II, Pollution Degree 2Electromagnetic compatibilityIEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class AAustralian RCMIEC 61326-1US F]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[11: Group 1, Class AAustralian RCMIEC 61326-1US FCCCFR 47, Part 15 Subpart C Sections 15.207, 15.209, 15.249Vibration0.03 g2/Hz (3.8 g), 2.5 g IEC 68-2-6Shock25 g, IEC 68-2-29DropEngineered to withst]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[Automatic Digital Enamel Rater for Cans]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Automatic_Digital_Enamel_Rater_for--12024209_12033080.html]]></link><description><![CDATA[9) Simple operation and maintenance. 
10) Assemble with HD camera for convenient after-sales service via remote connection. 
11) Test result can be sent to SPC system. 
12) Database management softwa]]></description><pubDate><![CDATA[20241225]]></pubDate></item>
<item>
<title><![CDATA[Digital Distance Meter]]></title><link><![CDATA[https://holo1.en.ec21.com/Digital_Distance_Meter--11942959_11942957.html]]></link><description><![CDATA[9
Laser class
Class II
10
Operating temperature
-5~40℃
11
Storage temperature
-20~60℃
12
Weight
41g
13
Dimension
70*34*19mm
14
Bluetooth model
BT04-E, double mode, support IOS, Android
Functions:]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[YH800F Portable Fully Automatic Pressure Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800F_Portable_Fully_Automatic_Pressure--12022422_12022441.html]]></link><description><![CDATA[9.High definition 7-inch color touch screen: Equipped with a high-definition 7-inch color touch screen, the interface is friendly, the operation is easy, the display information is clear and intuitiv]]></description><pubDate><![CDATA[20241105]]></pubDate></item>
<item>
<title><![CDATA[Smoke Heat Detector Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke_Heat_Detector_Test_Tunnel--11987076_11987966.html]]></link><description><![CDATA[950nm, range: 0~2 dB/m,
measuring range: 0 ~ 2 dB / m, measuring error shall not be greater than m×5%+0.02dB/m
7．
Wind speed: 0 to 1.5 m/s continuously
adjustable via software setting
when the win]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Portable Hardness Tester]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Portable_Hardness_Tester--11973711_12009824.html]]></link><description><![CDATA[9
Carry Case
1
10
Operating instruction
1
11
Calibration Certification
1
12
Guarantee Card
1
Optional Configuration
13
Cleaning brush (II)
1
For G type impact device
14
Other type of impact devices a]]></description><pubDate><![CDATA[20240925]]></pubDate></item>
<item>
<title><![CDATA[NDJ-1C Hot Melt Adhesives Brookfield Viscosity Meter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_1C_Hot_Melt_Adhesives--11144324_11144465.html]]></link><description><![CDATA[94-1995 Determination of viscosity of adhesives
HG/T 3660-1999 T Determination of melt viscosity of hot melt adhesives
Specification
Model No
NDJ-1C
Display
Backlit LCD, digital display
Speed (r/min)]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Shop Floor Portable CMM Measurement for Workshop Medium Workpieces]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Shop_Floor_Portable_CMM_Measurement--11944568_11946128.html]]></link><description><![CDATA[1140
2500
840
840
600
500
500
200
955 
1600
1140
2500
160
160
900
500
500
200
Features
1. Integrated design of mechanical host, control system and computer;
2. Adopt precision linear guide, which can]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[Quadrant Optoelectronic Module]]></title><link><![CDATA[https://gatherstar.en.ec21.com/Quadrant_Optoelectronic_Module--11943926_11943936.html]]></link><description><![CDATA[9
-
GS-QD2410-4
-120
12
-9
-
GS-QD2410-5
50±10%
12±10%
12±10%
-
GS-QD2410-7
70±10%
12±10%
12±10%
-
GS-QD2410-7A
70±10%
12±10%
12±10%
12
GS-QD2410-9
80
±5
-
-
GS-QD2410-11
70
12
12
-
GS-QD24]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-4 UL94 Horizontal and Vertical Flame Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_4_UL94_Horizontal--11940578_11941787.html]]></link><description><![CDATA[94, IEC60695-11-4, IEC60695-11-3, IEC60950, IEC707, IEC60695-2-2, ISO1210 and etc.. The flammability test uses a bunsen burner of a specified size and specified gas source (methane or natural gas) to]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[Smart Electricity Distribution Network Monitoring System]]></title><link><![CDATA[https://snova17.en.ec21.com/Smart_Electricity_Distribution_Network_Monitoring--10349843_10370312.html]]></link><description><![CDATA[9 indicator turn red, but the 11,12 indicator still
show white, that judged the point D happen short circuit
Used to judge the grounding fault indicator diagram:
As line 2# C phase 3,6,9 indicator tu]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[970197129739Moore Products 3441 Rosemount115120883001C3051, 3051S3044C64431443244, 3144P SiemensSITRANS P DSSITRANS P ES SMARLD301TT3011 ViatranI/A Pressure WikaUNITRANST32H1 YokogawaEJAYTA 110, 310 ]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Bruker Tracer 5i Handheld XRF Spectrometer]]></title><link><![CDATA[https://thexrfstore.en.ec21.com/Bruker_Tracer_5i_Handheld_XRF--11822199_11822200.html]]></link><description><![CDATA[9.4 cm x 29.5 cm (10.75 in x 3.7 in x 11.6 in) L x W x HWeight: 1.9 kg (4.1 lbs) with battery; 1.6 kg (3.6 lbs) without batteryPower: Li-Ion battery and charger; AC adapterExcitation source: Rhodium ]]></description><pubDate><![CDATA[20230720]]></pubDate></item>
<item>
<title><![CDATA[CDW-60 Impact Test Low Temperature Chamber / Environmental Chamber]]></title><link><![CDATA[https://astmtester123.en.ec21.com/CDW_60_Impact_Test_Low--9999940_10000040.html]]></link><description><![CDATA[9999 minutes, 1 minute resolution
8. Cooling medium: ethanol or other ice-free liquid
9. Stirring motor: 23W
10. The Working power: 220V ~ 240V, 50HZ, 2.3KW
11. Operating environment temperature: 5 ]]></description><pubDate><![CDATA[20190815]]></pubDate></item>
<item>
<title><![CDATA[LDS-50A 50kN Metal Material Universal Tensile Compression Bending and Shearing Testing Machine]]></title><link><![CDATA[https://lgtester789.en.ec21.com/LDS_50A_50kN_Metal_Material--10000302_10012238.html]]></link><description><![CDATA[200mm/min divide class adjustment;
7) Tensile space: 0~700mm
8) Compression space: 0~700mm
9) Test space width: 360mm
10) External size of host: 760*460*1900mm
11) Supply power: 0.75KW, 220V, 50Hz.
]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/3kW_3.5kW_4kW_5kW_6kW--11807084_11807114.html]]></link><description><![CDATA[9: Color/Style: RAL7035 or customized.10: Blowing rate: customized it to meet different requirement of heat dissipation capacity11: Wire color/length: customized.12: Packing: paper carton + wrapping ]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[18650 Lithium Battery]]></title><link><![CDATA[https://chamglobal.en.ec21.com/18650_Lithium_Battery--11857535_11857537.html]]></link><description><![CDATA[90
18650F8T
2500
3.6
≤25
7.5 A (3 C)
≥500
-40 ~ 60
18650F8R
2600
3.7
≤60
2.6 A (1 C)
≥300
-20 ~ 60
18650F30
3000
3.7
≤60
4.5 A (1.5 C)
≥300
-20 ~ 50
18650F5P
2200
3.6
≤20
11 A (5 C)
≥]]></description><pubDate><![CDATA[20231023]]></pubDate></item>
<item>
<title><![CDATA[Glow-wire Test Apparatus]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Glow_wire_Test_Apparatus--9657760_11802295.html]]></link><description><![CDATA[The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) &lt; basic testing methods]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[9. Short protection
Withstand short-circuit and alarm
10. Working mode
Withstand long-term continuous working at full load
11. Read output
Digital LED
12. Display precision
As per output values
13. D]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Automatic Borderline Pumping Temperature of Engine Oil Tester (MRV) ASTM D3829 ASTM D4684]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Automatic_Borderline_Pumping_Temperature_of--11718430_11718462.html]]></link><description><![CDATA[9. 
Work unit: 5 units
10. 
Power of the whole machine: 1200KW
11. 
Net weight: 20KG
12. 
Size: 470*320*420mm
Main Feature s 
1. 
Temperature range: temperature range 80 to -40℃, temperature contro]]></description><pubDate><![CDATA[20230201]]></pubDate></item>
<item>
<title><![CDATA[Glow-wire Test Apparatus]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Glow_wire_Test_Apparatus--11882688_11882702.html]]></link><description><![CDATA[The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) &lt; Basic testing methods]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[CR825 Common Rail Test Bench with HEUI EUI EUP CAMBOX VP37 VP44 CAT320D]]></title><link><![CDATA[https://geruisdiesel.en.ec21.com/CR825_Common_Rail_Test_Bench--11801992_11801997.html]]></link><description><![CDATA[9.Solenoid valve inductance test
10. Turn on pulse width test
11. Turn on the pressure test
12. The server updates system data online in real time.
13.Standard industrial air-conditioning and refrige]]></description><pubDate><![CDATA[20230605]]></pubDate></item>
<item>
<title><![CDATA[Coefficient of Friction Test for Electrochemical Aluminum Membrane/ Plastic Belt COF]]></title><link><![CDATA[https://systester18.en.ec21.com/Coefficient_of_Friction_Test_for--10834081_10898885.html]]></link><description><![CDATA[9: Micro-printer built-in.
10: Overload, limit position protection.
11: Low power consumption and silence running.
12: DB9 RS232 communication port.
13: COFlex professional computer software support.]]></description><pubDate><![CDATA[20221214]]></pubDate></item>
<item>
<title><![CDATA[Nirun Cone Plate Viscometerfor Sale]]></title><link><![CDATA[https://kobebean24.en.ec21.com/Nirun_Cone_Plate_Viscometerfor_Sale--11076331_11076337.html]]></link><description><![CDATA[9.Gigabit Ethernet port:ensure rapid and stable data transfer
10.External storage supports:single point,continuous and timing data
11.Temperature and correction factor:protected by password
12.Rotate]]></description><pubDate><![CDATA[20200310]]></pubDate></item>
<item>
<title><![CDATA[Flatness Measure Meter]]></title><link><![CDATA[https://yuanchenwujin68.en.ec21.com/Flatness_Measure_Meter--11261879_10963359.html]]></link><description><![CDATA[9) Adjust the position of measuring head, to ensure that the
measuring head is beyond 2mm-3mm of the plane of three support feet.
10) Gently stick the surface of the glass to ensure that
three suppor]]></description><pubDate><![CDATA[20230719]]></pubDate></item>
<item>
<title><![CDATA[High-End Full Automatic Touch Screen Transformer Oil Dielectric Strength Tester]]></title><link><![CDATA[https://transformeroilfilter.en.ec21.com/High_End_Full_Automatic_Touch--10553644_10706857.html]]></link><description><![CDATA[999s 
7. Stir time: 0 - 999s 
8. Wait time: 0 - 999s 
9. Measurement accuracy: &amp;plusmn; (1% of full scale + 2 digits) Resolution: 0.1KV 
10. Temperature measurement. 
11. Measurement range: 0&amp;deg;C t]]></description><pubDate><![CDATA[20180416]]></pubDate></item>
<item>
<title><![CDATA[GF1061 Portable CT PT Analyzer Is Mainly Used for Field or Lab Testing, It Can Finish the Measuremen]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/GF1061_Portable_CT_PT_Analyzer--10658146_10658147.html]]></link><description><![CDATA[9. Actual secondary load test (burden test)
10. Resistance test　
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[Horizontal Type Valve Pressure Test Bench]]></title><link><![CDATA[https://valvegrindingmachine.en.ec21.com/Horizontal_Type_Valve_Pressure_Test--10886107_10886118.html]]></link><description><![CDATA[9.6
15.0
24.0
30.0
37.5
48.0
Norminal Diameter(DN)
Sealing Pressure(MPa)
in
mm
12
300
2.5
4.0
6.5
10.0
16.0
20.0
14
350
3.5
5.5
9.0
13.6
22.0
28.0
16
400
4.5
7.0
11.5
18.0
28.0
18
450
5.6
9.0
14.5
22]]></description><pubDate><![CDATA[20220509]]></pubDate></item>
<item>
<title><![CDATA[Standard Portable Pendulum Skid Resistance and Friction Tester( Skid Tester for Civil)]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/Standard_Portable_Pendulum_Skid_Resistance--10976325_10976545.html]]></link><description><![CDATA[92/9 feet pads, for placing under levelling feet when on soft groundB0192/10 Operating instructions, A guide to road, floor and PSV testingB0192/11 tool setB0192/12 Calibration Certificate Despatched]]></description><pubDate><![CDATA[20230530]]></pubDate></item>
<item>
<title><![CDATA[Low Price Office Chair Backrest Durability Life Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Low_Price_Office_Chair_Backrest--11365007_11372363.html]]></link><description><![CDATA[900mm9. Machine size: 2200*1080*2200mm (L*W*H)10. SMC regulating valve device to ensure the cylinder output force is stable and reliable, digital display cylinder output force value 11. PLC control a]]></description><pubDate><![CDATA[20210423]]></pubDate></item>
<item>
<title><![CDATA[Carbon Dioxide Volume Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Carbon_Dioxide_Volume_Tester--11854816_11854820.html]]></link><description><![CDATA[9.Post-test, the carbonation volume is automatically 
and presented. 
10.Designed to prevent leaks, this versatile tester is 
suitable for both bottles and cans. 
11.(Optional) A microprinter can be ]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[Motor Test Bench / High-speed AC Power Dynamometer / Reducer Test Bench]]></title><link><![CDATA[https://hzchangniu.en.ec21.com/Motor_Test_Bench_High_speed--11882582_11882730.html]]></link><description><![CDATA[9.
单机扭矩范围宽（0-50000N.m），可充分
零速加载，转速可降到零而无扭矩
衰减，短时间内可达到满载的2倍。
10.
优异的负载性能：从零速到额定转速]]></description><pubDate><![CDATA[20240222]]></pubDate></item>
<item>
<title><![CDATA[IEC61180-1 Impulse Withstand Voltage Generator with 1.2/50us Waveform]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61180_1_Impulse_Withstand_Voltage--11421920_11425210.html]]></link><description><![CDATA[9999 times
7) Surge interval: 3~999s
8) Working environment: 15℃~35℃ (temperature), 10%~75% (humidity)
9) Working power: 220V±10% AC, 50/60Hz
10) Dimension: 470mm*260mm*500mm (W*H*D)
11) Weight:]]></description><pubDate><![CDATA[20210805]]></pubDate></item>
<item>
<title><![CDATA[TTR-I Fully Automatic Three Phase Power Transformer Turns Ratio Test Set]]></title><link><![CDATA[https://cndeltatech.en.ec21.com/TTR_I_Fully_Automatic_Three--11542988_11543002.html]]></link><description><![CDATA[continuously, frequency 50Hz
6
Power supply
AC220V ± 10%, 50Hz/60Hz
7
Environment temperature
0-50°C
8
Humidity
≤85%RH
9
Size
400mm*350mm*200 mm
10
Weight
7kg
11
Length of test cables
8 meters
]]></description><pubDate><![CDATA[20220314]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[9. Can establish multiple workpiece coordinate system:
10. It is convenient and fast to establish user programs:
11. Edit and modify user programs, intuitive and convenient.
12. Manual measurement ca]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Metal Oxide Surge Arrester Leakage Current Analyzer HFYH-8001B]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Metal_Oxide_Surge_Arrester_Leakage--11895397_11895400.html]]></link><description><![CDATA[9. In three - phase test, the instrument has automatic compensation function.
10. Three-phase voltage and three-phase current are collected and displayed at the same time.
11. It can directly measure]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[FLIR T530 24 Thermal Cameras with 24 Degree Lens, 30Hz]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/FLIR_T530_24_Thermal_Cameras--11561118_11567071.html]]></link><description><![CDATA[9) Faster processor and more responsive UI10) Folder structure for storing images11) Faster USB C chargingWarranty2 YEARSWarranty DetailsFLIR 2-5-10 Global Limited Warranty (2 years/components, 5 yea]]></description><pubDate><![CDATA[20230930]]></pubDate></item>
<item>
<title><![CDATA[WDW-S100 Electronic Universal Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/WDW_S100_Electronic_Universal_Testing--4048548_4709239.html]]></link><description><![CDATA[9
Loading mode
Electrically loading
10
Control mode
LCD digital display control
11
Power supply (should be firmly grounded)
-380V&amp;plusmn;10%, 50Hz; 1.5KW
12
Dimension of main machine (L*W*H)
850*555*]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[ACP Electrical Current Transformer Test, CT/PT Analyzer]]></title><link><![CDATA[https://aijiezn.en.ec21.com/ACP_Electrical_Current_Transformer_Test--3533367_11343743.html]]></link><description><![CDATA[9. Withstand Test of
Power Frequency Alternating Current 
10. Secondary Load Test
11. Secondary Winding Test
12. Measuring the
volt-ampere characteristics of medium and low voltage CTs and zero seque]]></description><pubDate><![CDATA[20210224]]></pubDate></item>
<item>
<title><![CDATA[New Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_Nortec_600D_Eddy--11801594_11801595.html]]></link><description><![CDATA[9% to 110% IACS or 0.5 to 64 MS/m. Accuracy within ±0.5% IACS from 0.9% to 65% IACS and within ±1.0% of values over 62%. Meets or exceeds BAC 5651 specifications.
Non-conductive coating thicknessCa]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[100V 120A 18650 Finished Battery Pack 100v200a 300a Tester for Lithium Battery Pack Assembly Line]]></title><link><![CDATA[https://aitop2018.en.ec21.com/100V_120A_18650_Finished_Battery--11585406_11639412.html]]></link><description><![CDATA[9. Test records can be saved to database (SQL) or file (Excel).10. Support the export and import function of test project.11. The equipment supports the same port and split port batteries for chargin]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[Liquid Chromatograph]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Liquid_Chromatograph--11907876_11909750.html]]></link><description><![CDATA[11kg
Operating environment temperature range: 4~40 ℃
UV visible variable wavelength detector
Wavelength range 190nm~700nm
Wavelength indication error ≤ ± 1nm
Wavelength repeatability error ≤ ]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[EMI Receiver System]]></title><link><![CDATA[https://15317383997.en.ec21.com/EMI_Receiver_System--11812738_11812765.html]]></link><description><![CDATA[9kHz; 120kHz• Connect PC via USB cable and software can run on Win7, Win8 and Win10, Win11
What is EMI receiver?Electromagnetic Interference (EMI receiver) is electronic noise that interferes with ]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[JB-300B Impact Testing Machine]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/JB_300B_Impact_Testing_Machine--6651349_6678350.html]]></link><description><![CDATA[9. Arc circle radius of impact knife: R2-2.5mm 
10. Sample specifications: 55 × 10 × 10mm 
11. Testing machine net weight: 450kg 
12. Testing machine dimension: 2124 × 600 × 1340mm 
13. Power Sup]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[Fully Automatic Film Processor]]></title><link><![CDATA[https://ndtchina.en.ec21.com/Fully_Automatic_Film_Processor--6581053_6161376.html]]></link><description><![CDATA[9&amp;atilde;11 
Develop speed (piece/h)&amp;iuml;&amp;frac14;
8&amp;times;30&amp;iuml;&amp;frac14;298&amp;iuml;&amp;frac14;1.75min&amp;iuml;&amp;frac14;/148&amp;iuml;&amp;frac14;3.5min&amp;iuml;&amp;frac14;/74&amp;iuml;&amp;frac14;7min&amp;iuml;&amp;fr]]></description><pubDate><![CDATA[20140520]]></pubDate></item>
<item>
<title><![CDATA[WA Digital Display Hydraulic Universal Testing Machine]]></title><link><![CDATA[https://hzyueke003.en.ec21.com/WA_Digital_Display_Hydraulic_Universal--6176826_6183002.html]]></link><description><![CDATA[9.bending stick distance 350mm
10.bending stick width 140mm
11.main frame size 740*580*2045
12.controller size 620*560*1560
13.oil pump power 1.5KW
14.distortion testing device staff
15.overload prot]]></description><pubDate><![CDATA[20150509]]></pubDate></item>
<item>
<title><![CDATA[Dyeing Rubbing Tester JIS Standard]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Dyeing_Rubbing_Tester_JIS_Standard--5441143_9767602.html]]></link><description><![CDATA[9.Friction distance: 100 mm 
10.Counter: LCD 0 -999,999 
11.Friction Group: 6 sets 
12.Power supply: AC220 50Hz 
13.Machine Size: about 60 * 50 * 40 cm 
STANDARDS 
JIS L0801,0823,0849,1006,1084,K6328]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Burst Tester]]></title><link><![CDATA[https://pnshar.en.ec21.com/Burst_Tester--6815878_6805020.html]]></link><description><![CDATA[When the bulge height is 18mm, the pressure is 250~350kpa 8. Upper clamp:31.5&amp;plusmn;0.05mm 9. Lower clamp: 31.5&amp;plusmn;0.05mm 10. Hydraulic transducer :&lt;6000kpa 11. Clamp pressure: &amp;ge;690kpa
]]></description><pubDate><![CDATA[20120619]]></pubDate></item>

</channel>
</rss>