<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 16 programs.]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/16_programs.--2717/1/16 programs..html]]></link><item>
<title><![CDATA[Smoke Heat Detector Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke_Heat_Detector_Test_Tunnel--11987076_11987966.html]]></link><description><![CDATA[16． 
Software
function: the equipment has the function of automatic operation detection.
Start with one key, and the test process is automatically completed by the
program. The process includes aut]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Walk in Environmental Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Walk_in_Environmental_Test_Chamber--11164019_11165141.html]]></link><description><![CDATA[Walk in Environmental Test Chamber
Technical specifications: 
Model 
TH780HD
TH7160HD
TH7200HD
Volume
8 m3
16 m3
20 m3
Internal dimensions (D*W*H)
2*2*2 m
2.6*2.8*2.2 m
3*3*2.2 m
External dimensions ]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[program calculating, Analysis ,judge the short circuit or ground fault. When Sensor detect the fault happen, then the Fault indicator warn the manager
through turn red flag, and shine 3 color ultra-l]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[programs or regulations. Record and document resultsHolds up to a full week of downloaded procedures and calibration results.Use many features like autostep, custom units, user entered values during ]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[program, the data can be automatically imported into professional SPC Software
15. In case of measurement failure or out of tolerance, intelligent processing can be carried out
16. Image altimetry fu]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[China Enviclone Programmable Walk in Large Size Salt Fog Spray Corrosion Test Chamber]]></title><link><![CDATA[https://enviclonetestchamber.en.ec21.com/China_Enviclone_Programmable_Walk_in--11887759_11887763.html]]></link><description><![CDATA[16 hours, take the average value)Spray pressure0.7~1.0kgf/cm²Spray methodContinuous/period sprayOperation modeSalt spray, wet, dry, condensation, spray (optional) can be combined in any combination ]]></description><pubDate><![CDATA[20240113]]></pubDate></item>
<item>
<title><![CDATA[ESS Chambers-Rapid Temperature Change Test Chamber]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/ESS_Chambers_Rapid_Temperature_Change--11847973_11848017.html]]></link><description><![CDATA[164, MIL-344A-4-16, MIL-2134A-19, NABMAT-9492, GJB-1032-90, GJB/Z34-5.1.6, IPC-9701....ETC.Rapid temperature change chamber have 2 test methods: ①temperature test ②average temperature testWith al]]></description><pubDate><![CDATA[20231107]]></pubDate></item>
<item>
<title><![CDATA[Automatic Borderline Pumping Temperature of Engine Oil Tester (MRV) ASTM D3829 ASTM D4684]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Automatic_Borderline_Pumping_Temperature_of--11718430_11718462.html]]></link><description><![CDATA[program temperature control
6. 
Heating method: electric heating tube heating
7. 
Detection method: photocell detection
8. 
Control method: computer automatic control
9. 
Work unit: 5 units
10. 
Powe]]></description><pubDate><![CDATA[20230201]]></pubDate></item>
<item>
<title><![CDATA[New Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_Nortec_600D_Eddy--11801594_11801595.html]]></link><description><![CDATA[program and data).On-board file preview.Portable and LightweightThe NORTEC 600 weighs only 1.6 kg and is delivered with a factory-installed hand strap that provides direct thumb access to the key con]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[CR825 Common Rail Test Bench with HEUI EUI EUP CAMBOX VP37 VP44 CAT320D]]></title><link><![CDATA[https://geruisdiesel.en.ec21.com/CR825_Common_Rail_Test_Bench--11801992_11801997.html]]></link><description><![CDATA[program(PC program/driver PC program) can be scrubbde.
Optional functions: 
1 、HEUI 3412 ISUZU function
2、 FORD6.0 Injector Carter 3408
3、 Measure six at the same time (without additional flow ]]></description><pubDate><![CDATA[20230605]]></pubDate></item>
<item>
<title><![CDATA[Gas Chromatography]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Gas_Chromatography--11907876_11907884.html]]></link><description><![CDATA[Program heating: 16th order
Total program time: 99999.9 minutes
Maximum heating rate: 120 ℃/min
Cooling method; Rear door opening+air-cooled or liquid nitrogen
Temperature range: 7 ℃~450 ℃ abov]]></description><pubDate><![CDATA[20240301]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Furniture Mechanics Comprehensive Test Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Hot_Sale_Furniture_Mechanics_Comprehensive--11365007_11365011.html]]></link><description><![CDATA[Program screen can choose simplified Chinese, traditional Chinese, English, in Program Settings page can be changed at will.
16. Computer + force sensor + encoder form force and displacement closed-l]]></description><pubDate><![CDATA[20210416]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Omniscan MX2 PA Flaw Detector]]></title><link><![CDATA[https://tol22man.en.ec21.com/Used_Olympus_Omniscan_MX2_PA--11836190_11836198.html]]></link><description><![CDATA[programs (NDT SetupBuilder and new OmniPC version) that expand the capabilities of the successful OmniScan MX2 platform and improve the workflow efficiency of nondestructive testing inspections.
Buil]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61000_4_5_Lightning_Surge--11421920_11421956.html]]></link><description><![CDATA[program, and has 1000 groups memories.
3. 
Monitoring the surge voltage and current waveform by work with an external oscilloscope.
4. 
Built in single phrase 10A (16A) network, makes the equipment s]]></description><pubDate><![CDATA[20210729]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[Programming output voltage
Adjustable (0~rated value) or CV
6. Programming output current
Adjustable (0~rated value) or CC
7. Adjusting mode
10-turn Potentiometer 
Key button (optional)
8. Protection]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Horizontal and Vertical Flammability Tester UL94 IEC 60695]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Horizontal_and_Vertical_Flammability_Tester--5441143_9767620.html]]></link><description><![CDATA[program automatic control, independent convulsions 
14.Studio volume: 0.75 cubic, stainless steel chassis 
15.Dimension(w*d*h): 1100 *700 *1300 mm 
16.Weight: 190 kg 
17.Power: AC 220V,50Hz 
STANDARD]]></description><pubDate><![CDATA[20170530]]></pubDate></item>