<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 2 stage]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/2_stage--2717/1/2 stage.html]]></link><item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[2-point viewing angle, easy for watching;
★Alarm mode: sound, light, shadow three alarm modes, leakage detection prompt flashing, automatic voice broadcast the results after the completion of detec]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[YH630A Floor Type Fully Automatic Pressure Calibration Bench - Three Units]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH630A_Floor_Type_Fully_Automatic--12022422_12022423.html]]></link><description><![CDATA[stage promotion function, perfectly realize the reverse verification of the pointer gauge;
◆10-inch touch screen display, icon management menu, Chinese and English operation interface;
◆Number of]]></description><pubDate><![CDATA[20241105]]></pubDate></item>
<item>
<title><![CDATA[Temperature Humidity Vibration Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Temperature_Humidity_Vibration_Test_Chamber--11164019_11164169.html]]></link><description><![CDATA[2500*1000*2150 mm
2830*1200*2250 mm
Table dimensions of vibrating table
Table ≤400*400 (Ф400)
Table ≤600*600 (Ф600)
Performance 
Temperature range
-70…+150℃
Temperature fluctuation
≤1℃
]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[ST-6601 Insulation &amp; Continuity Tester]]></title><link><![CDATA[https://satatec.en.ec21.com/ST_6601_Insulation_Continuity_Tester--7687564_7687932.html]]></link><description><![CDATA[LED.
Technical parameters:
Wire sensitivity: ≥10pF;
Test voltage: Max 500V/DC;
Insulation resistance: 2, 7, 20, 50, 100, 200MΩ, total 6 stages for option;
Audio and video indicate for pass.
]]></description><pubDate><![CDATA[20240615]]></pubDate></item>
<item>
<title><![CDATA[Digital Infrared Radiometer]]></title><link><![CDATA[https://gatherstar.en.ec21.com/Digital_Infrared_Radiometer--11943208_11943246.html]]></link><description><![CDATA[2-4 stage TE cooled PVMCT
2-4 stage TE cooled PVMCT LN cooled or stirling cooled InSb或HgCdTe
Spectral Response 
2-14μm
2-5μm or 2-14um
2-5μm or 2-14μm、
NEI 
5E-3W/cm*cm
5E-8W/cm*cm
5E-12W/cm*]]></description><pubDate><![CDATA[20240527]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-4 UL94 Horizontal and Vertical Flame Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_4_UL94_Horizontal--11940578_11941787.html]]></link><description><![CDATA[stage surround the electric and electronics appliance, and then evaluate the degree of fire hazard. It
is designed according to UL94, IEC60695-11-4, IEC60695-11-3, IEC60950, IEC707, IEC60695-2-2, ISO]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[Quick Temperature Variation Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Quick_Temperature_Variation_Chamber--11853101_11853627.html]]></link><description><![CDATA[25HD
KWGD705HD
KWGD710HD
Internal volume
252 L
504 L 
1000 L
Internal dimensions (D*W*H) 
600*600*700 mm 
700*800*900 mm 
1000*1000*1000 mm 
External dimensions (D*W*H) 
1750*900*1800 mm
2150*1050*19]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[Sobek SP-3015B Vertical  Profile Projector]]></title><link><![CDATA[https://sobek.en.ec21.com/Sobek_SP_3015B_Vertical_Profile--10029761_10670642.html]]></link><description><![CDATA[Model
SP-3015B (Erect Image)
SP-3020B (Erect Image)
Metal stage size
340&amp;times;152mm
400&amp;times;225mm
Glass stage size
190&amp;times;75mm
210&amp;times;112mm
Travel&amp;mdash;X, Y axis
150&amp;times;50mm
200&amp;times;10]]></description><pubDate><![CDATA[20190123]]></pubDate></item>
<item>
<title><![CDATA[X6000 Series Load Modules]]></title><link><![CDATA[https://xinertel.en.ec21.com/X6000_Series_Load_Modules--10761704_10761708.html]]></link><description><![CDATA[stage of R &amp; D, experiment and qualit
X6000 series test modules are high-performance professional load modules running on TestStorm series and support all the features of TestStorm platform. X6000 Se]]></description><pubDate><![CDATA[20190419]]></pubDate></item>
<item>
<title><![CDATA[NAYD Series Oil Gas Dry Type Testing Transformer]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/NAYD_Series_Oil_Gas_Dry--10586983_10725192.html]]></link><description><![CDATA[2. The voltage margin is high, corona sound is small, partial discharge is small. 
3. Adopting modern insulating materials, small in size, light in weight 
NAYDQ Series Gas type Testing Transformer 
]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Buy Air-cooled Two-Stage Piston Condensing Units]]></title><link><![CDATA[https://kendallcool.en.ec21.com/Buy_Air_cooled_Two_Stage--11754147_11827298.html]]></link><description><![CDATA[stage compression process to cool and condense refrigerant. It is called &quot;air-cooled&quot; because it uses air as the heat transfer medium to cool the refrigerant.
2. What are the advantages of using an a]]></description><pubDate><![CDATA[20230731]]></pubDate></item>
<item>
<title><![CDATA[Active Piston Prover]]></title><link><![CDATA[https://royreal.en.ec21.com/Active_Piston_Prover--11907986_11908005.html]]></link><description><![CDATA[2. High accuracy of temperature and pressure measurement.3. Piston stroke precision measurement.4. Wide range of flow and pressure, stable output.5. Multi-stage seal, no leakage, self-lubrication.6. ]]></description><pubDate><![CDATA[20240301]]></pubDate></item>
<item>
<title><![CDATA[ESS Chambers-Rapid Temperature Change Test Chamber]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/ESS_Chambers_Rapid_Temperature_Change--11847973_11848017.html]]></link><description><![CDATA[200°C in a single stage or -73°C to 200°C in a cascade. The fast rate change chamber uses scroll compressor technology to provide quiet operation, fast conversion rates and reliable operation. The]]></description><pubDate><![CDATA[20231107]]></pubDate></item>
<item>
<title><![CDATA[Smart Bluetooth Speaker Sound Testing Certification BQB WIFI SIRIM KC India BIS SASO SABER PVOC SONC]]></title><link><![CDATA[https://lcscertification.en.ec21.com/Smart_Bluetooth_Speaker_Sound_Testing--11870786_11870787.html]]></link><description><![CDATA[stage of industrial ecological construction. From a longer-term perspective, among smart speaker head manufacturers, regardless of whether they are ecologically open or closed, whether industrial upg]]></description><pubDate><![CDATA[20231128]]></pubDate></item>
<item>
<title><![CDATA[Gold Supplier Programmable Constant Temperature and Humidity Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Gold_Supplier_Programmable_Constant_Temperature--11372570_11372574.html]]></link><description><![CDATA[20ºC average 1ºC/min8. Temperature and humidity controller: balance temperature and humidity control system9. Refrigeration system: air-cooled, two-stage, fully sealed compressor, original imported]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[Gas Pycnometer Analyzer G-DenPyc 2900]]></title><link><![CDATA[https://goldapp.en.ec21.com/Gas_Pycnometer_Analyzer_G_DenPyc--9431275_9269540.html]]></link><description><![CDATA[G-DenPyc 2900 gas pycnometer helium true density analyzer introduction
A gas pycnometer operates by detecting the pressure change resulting from displacement of gas by a solid object. Expanding a qua]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Refractometer RA-620 / RA-600]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Refractometer_RA_620_RA_600--8755029_8755113.html]]></link><description><![CDATA[20W (max. 50W, min. 10W)
Dimensions
192 (W) &amp;times; 281 (D) &amp;times; 166 (H) mm
Weight
5kg
Materials in Contact 
with Samples
Prism
Artificial Sapphire
Sample Stage
SUS316
Expandability
Barcode Reader]]></description><pubDate><![CDATA[20140212]]></pubDate></item>
<item>
<title><![CDATA[Programmable Control Temperature Humidity Tester]]></title><link><![CDATA[https://annie0423.en.ec21.com/Programmable_Control_Temperature_Humidity_Tester--9938678_9938741.html]]></link><description><![CDATA[20 ~ 98%R.H.
Temp. &amp; Humid. accuracy:
&amp;plusmn; 0.3&amp;deg;C; &amp;plusmn; 2%R.H
Temp. &amp; Humid. regularity:
&amp;plusmn; 2&amp;deg;C; &amp;plusmn; 5% RH
Resolution:
0.1&amp;deg;C, 1%, P.I.D control
Heating up:
-40&amp;deg;C ~ +]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>