<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 2 temperature]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/2_temperature--2717/1/2 temperature.html]]></link><item>
<title><![CDATA[Fluke 87V Industrial Multimeter 2025]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_87V_Industrial_Multimeter_2025--11790575_11793411.html]]></link><description><![CDATA[200 kHzAccuracy±(0.005% + 1)Maximum resolution0.01 HzDuty cycleMaximum duty cycle99.9%Accuracy±(0.2% per kHz + 0.1%)Maximum resolution0.1%Temperature measurement–200.0 °C – 1090 °C–328.0 °]]></description><pubDate><![CDATA[20250321]]></pubDate></item>
<item>
<title><![CDATA[Fluke 3540 FC KIT Three-Phase Power Monitor]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_3540_FC_KIT_Three--12045274_12045343.html]]></link><description><![CDATA[Fluke 3540 FC KIT Specifications
Environmental SpecificationsOperating Temperature32 to 113°F (0 to 45°C)Storage Temperature-4C to 140°F (&lt;20 to 60°C), with battery: -4 to 122°F (-20 to 50°C)Op]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[FLIR E4 Thermal Imager with MSX Technology 80  60 (4,800 Pixels) with WiFi]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/FLIR_E4_Thermal_Imager_with--11561118_11567185.html]]></link><description><![CDATA[Temperature Range Max482 FTemperature Range Min-4 FImage Frequency9 HzField of View45x34 DegreesScreen Size3.0 INIR/Overlay Fusion ImageYes Video OutputNoFocusFixedLaser SpotNoPicture in PictureNoVid]]></description><pubDate><![CDATA[20250221]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[Temperature Range Max1832 FTemperature Range Min-14 FImage Frequency60 HzField of View34 x 24 DegreesScreen Size3.5 INIR/Overlay Fusion ImageYesVideo OutputYesFocusAdjustable and FixedLaser SpotYesPi]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[WDLYCH/WDLHCN CCS Marine Analog Panel Current Meter/Ammeter for Switchboards]]></title><link><![CDATA[https://jade900920.en.ec21.com/WDLYCH_WDLHCN_CCS_Marine_Analog--11663243_12026218.html]]></link><description><![CDATA[20% when scale reaches to 2/3
Insulation
Circuit &amp; shell: AC2600V/1 minute(Water area)
Indicating Angle
90/240-270°
Temperature
-13-33℃, 100% comply with accuracy class
Technical Standards
GB/T767]]></description><pubDate><![CDATA[20241227]]></pubDate></item>
<item>
<title><![CDATA[Negative Ion Detector]]></title><link><![CDATA[https://renke2001.en.ec21.com/Negative_Ion_Detector--11945320_12031071.html]]></link><description><![CDATA[RS-NEGO-N01-2-*-EX Negative ion detector with color touch screen, real-time display of negative oxygen ion concentration in the air, optional measurement elements such as temperature and humidity, fo]]></description><pubDate><![CDATA[20241213]]></pubDate></item>
<item>
<title><![CDATA[Laser Distance Measuring]]></title><link><![CDATA[https://holo1.en.ec21.com/Laser_Distance_Measuring--11942959_11942997.html]]></link><description><![CDATA[2mm
Laser Class
Ⅱ
Battery Life
＞10000 times
Working temperature
-10℃～+50℃
Storage temperature
-25℃～+65℃
Functions:
The Power of Laser Distance Measuring:
Imagine swiftly and accuratel]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[0.8-8GHz Precision 4 Way Power Splitter Power Divider with SMA Connector]]></title><link><![CDATA[https://tojoin001.en.ec21.com/0.8_8GHz_Precision_4_Way--11449529_11449555.html]]></link><description><![CDATA[25
1.35
Amplitude Balance（dB）
—
—
0.5
Phase Balance（°）
—
—
5
Impedance（Ω）
—
50
—
Connectors
—
SMA
—
Power Capacity（W）
—
10
—
Operating Temperature（°C）
-30
n]]></description><pubDate><![CDATA[20241204]]></pubDate></item>
<item>
<title><![CDATA[Heat Alarm &amp; Detector Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Heat_Alarm_Detector_Test_Tunnel--11987076_11987723.html]]></link><description><![CDATA[2 and ISO
standards. The standard test tunnel is composed of tunnel, heater, Chiller,
temperature control system, computer etc. According to the requirements of
standard specifications and parameters]]></description><pubDate><![CDATA[20241122]]></pubDate></item>
<item>
<title><![CDATA[Rail Cant Measurement Device for Rail Inclination Measuring Device]]></title><link><![CDATA[https://420621199211083365.en.ec21.com/Rail_Cant_Measurement_Device_for--12025008_12025012.html]]></link><description><![CDATA[200Accuracy±0.05°Resolution0.01°operating voltage3.5v ~ 4.2vcharging voltage4.5v ~ 5.5voperating temperature-30℃ ~ +60℃display modeOLEDProduct nameRail Cant Measurement DevicePackaging and del]]></description><pubDate><![CDATA[20241116]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[ModelStudio Size (D*W*H)mmDimension（D*W*H）mmLRHS-101B-3LJ450×450×500Subject to contractual three-viewLRHS-225B-3LJ500×600×750temperature rangeA:-20℃～150℃ B:-40℃～150℃C:-60℃～150]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[YH800 Intelligent Digital Pressure Calibrator]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800_Intelligent_Digital_Pressure_Calibrator--12022422_12022535.html]]></link><description><![CDATA[temperature, switch status, and time.
This instrument has a DC 24V power output function, suitable for various application scenarios. In addition,YH800 pressure calibrator also integrates various add]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[Emcee Model 1150 Staticon]]></title><link><![CDATA[https://xmjielian.en.ec21.com/Emcee_Model_1150_Staticon--11982130_11982355.html]]></link><description><![CDATA[temperature. The Console Module, as shown, can handle 2 streams by adding an additional Fuel Cell Module and barriers to the existing Barrier Module. Various other conductivity ranges are available.T]]></description><pubDate><![CDATA[20240808]]></pubDate></item>
<item>
<title><![CDATA[Surface Roughness Gauge]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Surface_Roughness_Gauge--11973711_11973717.html]]></link><description><![CDATA[error
±(7-10)%
Variability
&lt;6%
Data Storage
100 groups
Power
Rechargeable li-battery
Working temperature
-20℃～40℃
Relative humidity
&lt;90%
Size
158mmx63.5mmx46mm
Weight of Host
0.3kg
]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[NDJ-1C Hot Melt Adhesives Brookfield Viscosity Meter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_1C_Hot_Melt_Adhesives--11144324_11144465.html]]></link><description><![CDATA[200,000) (standard, use 21, 27, 28, 29 # rotor)
1-2000 (using 0# rotor)
Measurement error (Newtonian liquid)
±3%
Repeat error (Newtonian liquid)
±0.5%
Heating method
Electric heating
Temperature co]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Cuvettes&amp;Cuvettes(Glass)&amp;Cuvettes (Quartz)]]></title><link><![CDATA[https://biogene123.en.ec21.com/Cuvettes_Cuvettes_Glass_Cuvettes_Quartz--11963552_11963584.html]]></link><description><![CDATA[temperature.
2.
Product Information
Cat. No.Product NameSizeFeaturePackageBCQ-5Cuvette5mmquartz2pcs/boxBCQ-10Cuvette10mmquartz2pcs/boxBCQ-20Cuvette20mmquartz2pcs/boxBCQ-30Cuvette30mmquartz2pcs/boxBCQ]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Fully Automatic Online Surface Defect Detection Equipment BQJ-D4100]]></title><link><![CDATA[https://measurementon.en.ec21.com/Fully_Automatic_Online_Surface_Defect--11962128_11962130.html]]></link><description><![CDATA[20m/s
Adaptable rolling temperature: ≤1200℃
A Surface Inspection System
is a technology used to detect and analyze defects or irregularities on the surfaces of various materials. These systems ar]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[2 Axis 2 Frame POD Multiple Spectral Electro Optic Camera Sensor 4.5kg]]></title><link><![CDATA[https://leadir.en.ec21.com/2_Axis_2_Frame_POD--11958808_11958803.html]]></link><description><![CDATA[2km
Ranging Accuracy
≤3m(RMS)
Ranging Frequency
1Hz
Environmental Adaptability
Operating Temperature
−20°c~+50°c
Storage Temperature
-30°c~+55°c
Humidity
(95±3)%(±40°c)
Application
Search ]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[Film-stretching Instrument | Laboratory  Film Stretching Machine]]></title><link><![CDATA[https://potopyangliu.en.ec21.com/Film_stretching_Instrument_Laboratory_Film--11956821_11958740.html]]></link><description><![CDATA[2000Nm
Clamp pressure
2.5MPa
Operating temperature
Room temperature-350°C
Operating temperature accuracy
±3℃
Stretching motor power
3.5kW
Working voltage
3φ380VAC±10%，1φ220VAC±10%，50Hz
Ra]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[108L Salt Spray Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/108L_Salt_Spray_Chamber--11164019_11164134.html]]></link><description><![CDATA[200*500 mm
1000*1600*500 mm
1200*2000*600 mm
External dimensions (D*W*H)
672*1150*1090 mm
842*1450*1200 mm
1240*2080*1285 mm
1450*2480*1520 mm
1650*2900*1550 mm
Lab Temperature
Saline testing method ]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Sand and Dust Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Sand_and_Dust_Test_Chamber--11853101_11854273.html]]></link><description><![CDATA[blowing dust time can be set, cycle period can be
adjusted, time can be adjusted.
Safety device
Over-temperature
protection, grounding protection, etc.
Power supply
AC 220V/380V±10%,
50 Hz±0.5Hz
]]></description><pubDate><![CDATA[20240619]]></pubDate></item>
<item>
<title><![CDATA[ST-6608 Static Force Test Machine]]></title><link><![CDATA[https://satatec.en.ec21.com/ST_6608_Static_Force_Test--7687564_7687808.html]]></link><description><![CDATA[temperature etc.
Technical parameters:
Test workstation: 6 groups of specimens;
Weight: 2Lb, 5Lb, 8Lb &amp; 10Lb, each 6pcs and portfolio stackable the weight suitable difference specimen for testing;
Su]]></description><pubDate><![CDATA[20240614]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-2 Electrostatic Discharge Generator with 20KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_2_Electrostatic_Discharge--11944039_11946383.html]]></link><description><![CDATA[2kV
8.0A ±30％ @ 4kV
12.0A ±30％ @ 6kV
16.0A ±30％ @ 8kV
Current at 60ns
2.0A ±30％ @ 2kV
4.0A ±30％ @ 4kV
6.0A ±30％ @ 6kV
8.0A ±30％ @ 8kV
Environment:
Temperature:15°C－35
°C
;Hum]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[Large Size CNC CMM Measuring Machine Fotuna Series XYZ 203015]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Large_Size_CNC_CMM_Measuring--11944568_11944823.html]]></link><description><![CDATA[temperature solid solution and natural aging treatment to ensure the long-term stability of the equipment, such as three-axis gearbox, Y-slide, XZ slide, etc.
The measuring machine has passed the 72-]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[320x256 30um SWIR InGaAs Image Sensor]]></title><link><![CDATA[https://gatherstar.en.ec21.com/320x256_30um_SWIR_InGaAs_Image--11943926_11943949.html]]></link><description><![CDATA[20x256 Array Format
High sensitivity, high uniformity, high linearity, low noise, large dynamic range
Embedded thermoelectric cooler, accurately control the chip temperature
ITR, IWR standard integra]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Smart Electricity Distribution Network Monitoring System]]></title><link><![CDATA[https://snova17.en.ec21.com/Smart_Electricity_Distribution_Network_Monitoring--10349843_10370312.html]]></link><description><![CDATA[200A
Applicable wire diameter: 16mm sq≤D≤240mm sq
Action response time: 0.06s≤t≤3s
Reset time: 6,12,24,48H (Selectable, Default 24H)
Ambient temperature: -35℃≤T≤+70℃
Operation times: ]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[HTT-02 Hot Tack Tester]]></title><link><![CDATA[https://materialstests.en.ec21.com/HTT_02_Hot_Tack_Tester--11896648_11938409.html]]></link><description><![CDATA[2.Temperature Control:
The HTT-02 maintains precise temperature control during testing to simulate the conditions encountered during the sealing process accurately.
3.Pressure Application:
It applies]]></description><pubDate><![CDATA[20240517]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[Temperature instruments Coriolis instruments ABB/Kent-Taylor600T658T1 ABB/Hartmann &amp; BraunContrans P1,AS 800 Series Endress &amp; HauserCERABAR S,CERABAR M,DELTABAR STMT 1221,TMT 1821,TMT 1621 Foxboro Ec]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD31 Constant Acceleration Tester (Arm Type)]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD31_Constant_Acceleration_Tester_Arm--11098426_11099456.html]]></link><description><![CDATA[2000
Power Supply
3-phase AC 380V±10％ 50Hz
Control Mode
Fully closed-loop
digital network (remote) automatic control + manual control
Working
Environment
Temperature range
0～40℃, Humidity≤80]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Hot Tack Tester ASTM F2029 Hot Seal Strength Testing Instrument Plastic Packaging Hot Tack Strength]]></title><link><![CDATA[https://celtec.en.ec21.com/Hot_Tack_Tester_ASTM_F2029--9267548_9296214.html]]></link><description><![CDATA[232 port and professional software
Hot Tack Tester Technical Specifications
Items Parameters
Sealing Temperature Ambient～250℃
Temp Accuracy ±0.2℃
Heat Seal Dwell Time 0.1~9999s
Hot Tack Dwell ]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[TTR-I Fully Automatic Three Phase Power Transformer Turns Ratio Test Set]]></title><link><![CDATA[https://cndeltatech.en.ec21.com/TTR_I_Fully_Automatic_Three--11542988_11543002.html]]></link><description><![CDATA[2000 ± 0.2%RDG 2000-10000 ± 0.5%RDG
5
Test voltage
AC 0~80V continuously, frequency 50Hz
6
Power supply
AC220V ± 10%, 50Hz/60Hz
7
Environment temperature
0-50°C
8
Humidity
≤85%RH
9
Size
400mm*3]]></description><pubDate><![CDATA[20220314]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[220 V ± 10%, 50 Hz electrical equipment requires reliable grounding: the grounding resistance is less than 4 ohms
work environment
Temperature 20 ℃± 5 ℃, temperature change ＜ 2 ℃ / HR, humi]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Programmable Touch Screen Desktop Environmental Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Programmable_Touch_Screen_Desktop_Environmental--11825687_11825716.html]]></link><description><![CDATA[Temperature Range
(RT+10°C) ~+150°C
0~+150°C
-20 ~+150°C
Humidity Range
20%~98%R.H.
Indication Resolution/
Distribution
Uniformity of
Temperature
and Humidity
0.1°C; 0.1% R.H / ±2.0°C; ±3.0% ]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Multi-channel Multi-function Intelligent Temperature and Humidity Itinerant Detector]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Multi_channel_Multi_function_Intelligent--11689589_11689607.html]]></link><description><![CDATA[24 units 5V power output for the sensor power.
The product can be connected to the PC terminal or mobile terminal by wired or wireless way, and is suitable for the temperature field, humidity field, ]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[G100-10n | Incubator CO2 and O2 Analyzer]]></title><link><![CDATA[https://viasensor.en.ec21.com/G100_10n_Incubator_CO2_and--11522405_11602241.html]]></link><description><![CDATA[2 0-20% And O2 0-100%
Improved Accuracy On CO2 Readings
Quick Verification Of CO2 Incubator Levels
Time Saving With Dual Temperature Probes
Large Data Storage And User Friendly Software And Download
]]></description><pubDate><![CDATA[20220713]]></pubDate></item>
<item>
<title><![CDATA[100kW/200kW/500kW/800kW/1000kW/1200kW/2000kW AC Dummy Resistive Load Bank for Generator Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/100kW_200kW_500kW_800kW_1000kW--11807078_11807097.html]]></link><description><![CDATA[temperature,fan fault protection,emergency stop
Work voltage : AC380V/50Hz,3 phase 4 wire
Cooling mode : forced air cooling, horizontal air inlet/out let
Insulation class : FProtection grade : IP23(w]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[18650 Lithium Battery]]></title><link><![CDATA[https://chamglobal.en.ec21.com/18650_Lithium_Battery--11857535_11857537.html]]></link><description><![CDATA[Temperature (℃)
18650F56
2200
3.7
≤60
2.2 A (1 C)
≥300
-20 ~ 60
18650F8M7
2600
3.6
≤30
7.5 A (3 C)
≥1000
-20 ~ 60
18650F9M
3200
3.6
≤40
9.3 A (3 C)
≥1000
-20 ~ 60
18650F9L
3350
3.6
≤6]]></description><pubDate><![CDATA[20231023]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[temperature range: -10 °C to 45 °C (14 ºF to 113 ºF)Storage temperature range: –20 °C to 60 °C (–4 ºF to 140 ºF) with batteryStorage temperature range: –20 °C to 70 °C (–4 ºF to 15]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[Intelligent Temperature Measuring Machine]]></title><link><![CDATA[https://auroraguoxia12.en.ec21.com/Intelligent_Temperature_Measuring_Machine--11599950_11770469.html]]></link><description><![CDATA[temperature detection distance is 0.5-1 meters;
RGB three-color fill light real-time feedback recognition results, night infrared, RGB dual fill light;
Support serial port, Wiegand 26, 34 output and ]]></description><pubDate><![CDATA[20230417]]></pubDate></item>
<item>
<title><![CDATA[SciAps X-555 Handheld XRF Analyzer]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/SciAps_X_555_Handheld_XRF--11834264_11834285.html]]></link><description><![CDATA[temperatures. The X-555 uses the latest software, materials and engineering for improved performance in high ambient temperatures and outstanding heat dissipation.
Customize for your job“The X-555 ]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[MDKW-SL Gas Meter Real Flow Recirculation Calibration Facility]]></title><link><![CDATA[https://royreal.en.ec21.com/MDKW_SL_Gas_Meter_Real--11907986_11909844.html]]></link><description><![CDATA[2%Working Pressure
(2～10) kPa
Combustible Gas Replacement Medium
Nitrogen
Environment Temperature
(20±2)℃
Relative Humidity
≤90%
Compressed Gas
（0.45～0.7）MPaPower Supply
380V±10％, 15A]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[F316 Smart Battery Calibration]]></title><link><![CDATA[https://szdianliang.en.ec21.com/F316_Smart_Battery_Calibration--11842634_11842640.html]]></link><description><![CDATA[2. Do not expose this product to rain or humidity.
3. Do not subject the product to mechanical shock
4. Do not expose this product to heat sources, fire sources or high temperature environments, and ]]></description><pubDate><![CDATA[20230908]]></pubDate></item>
<item>
<title><![CDATA[China Enviclone Programmable Walk in Large Size Salt Fog Spray Corrosion Test Chamber]]></title><link><![CDATA[https://enviclonetestchamber.en.ec21.com/China_Enviclone_Programmable_Walk_in--11887759_11887763.html]]></link><description><![CDATA[temperature and humidity together. 
enviClone has such test chambers compliant with test standards ASTM B117-2009, Mil-Std-810G, DIN 50 021, DIN EN ISO 9227-2006, CNS 4159, CASS, JIS H8502, IEC 68-2-]]></description><pubDate><![CDATA[20240113]]></pubDate></item>
<item>
<title><![CDATA[Programmable Rapid-rate Thermal Cycle Chamber]]></title><link><![CDATA[https://irfanzahidi.en.ec21.com/Programmable_Rapid_rate_Thermal_Cycle--11888169_11888188.html]]></link><description><![CDATA[Our Rapid-rate Thermal Cycle Chamber has a fast temperature change rate, with a 
mechanical refrigeration rate of up to 20 °C/min. It also has high control accuracy, 
with a fluctuation degree of ]]></description><pubDate><![CDATA[20240117]]></pubDate></item>
<item>
<title><![CDATA[Flexible Rogowski Coils]]></title><link><![CDATA[https://xinghuodianzi.en.ec21.com/Flexible_Rogowski_Coils--11857606_11857607.html]]></link><description><![CDATA[temperature, humidity, EMI).Current Range: 100A to 100kAAccuracy: &lt; 1%Phase Shift: &lt; 1 degrees at 50/60Hz (&lt; 0.5 degrees typical) /li&gt;Linearity: ±0.2% from 10% to 100% of rated primary currentPrimar]]></description><pubDate><![CDATA[20231031]]></pubDate></item>
<item>
<title><![CDATA[ESS Chambers-Rapid Temperature Change Test Chamber]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/ESS_Chambers_Rapid_Temperature_Change--11847973_11848017.html]]></link><description><![CDATA[temperature change test chamber, accelerated stability chamber,pressure test chamber is designed to simulate the harshest environmental conditions at acceleration rates of -35°C to 200°C in a singl]]></description><pubDate><![CDATA[20231107]]></pubDate></item>
<item>
<title><![CDATA[LITE800 Industrial SLA 3D Printer]]></title><link><![CDATA[https://uniontech3d.en.ec21.com/LITE800_Industrial_SLA_3D_Printer--11706631_11807017.html]]></link><description><![CDATA[200-240 VAC, 50/60 Hz, Single phase
Rated Power
2.8 kVA
Systems Control
Closed-loop
Temperature Range
72–79 °F (22–26 °C)
Maximum Change Rate
1 °C/hour
Relative Humidity
&lt; 40%
Machine Size (W ]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Laboratory Film Pharmaceutical Lab Instruments Oxygen Permeability Tester GBPI]]></title><link><![CDATA[https://gbpitester.en.ec21.com/Laboratory_Film_Pharmaceutical_Lab_Instruments--11629254_11631109.html]]></link><description><![CDATA[2~16500 cm3/m2·24h（Film）With mask can be 260000 cm3/m2·24hTest Accuracy 0.001 cm3/m2·24hTemperature range 15~45℃(5~50℃optional ）Temperature
accuracy ±0.1℃Humidity range 30~90%RH，100]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[DroppingPointof LubricatingGrease Tester]]></title><link><![CDATA[https://precisionbe.en.ec21.com/DroppingPointof_LubricatingGrease_Tester--11718430_11856907.html]]></link><description><![CDATA[2176 GB/T4929
2. Pressure display: LCD digital display
3. Temperature control accuracy: ±0.1℃
4. Heating method: electric heating tube heating
5. Working unit: 2 tubes
6. Machine power: 800W
7. Wo]]></description><pubDate><![CDATA[20231020]]></pubDate></item>
<item>
<title><![CDATA[Toughened Glass Shelves]]></title><link><![CDATA[https://huideglass.en.ec21.com/Toughened_Glass_Shelves--11799621_11836553.html]]></link><description><![CDATA[temperature change around 200°C.
4. Toughened glass panels will shatter into oval-shaped fragments when broken, which eliminates the danger of sharp edges and relatively harmless to human body.
6. 
]]></description><pubDate><![CDATA[20230822]]></pubDate></item>

</channel>
</rss>