<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 3 dimension heating system]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/3_dimension_heating_system--2717/1/3 dimension heating system.html]]></link><item>
<title><![CDATA[High Low Temperature and Humidity Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/High_Low_Temperature_and_Humidity--11164019_11164045.html]]></link><description><![CDATA[dimensions (D*W*H)
400*400*400 mm
450*450*550 mm
600*600*700 mm
700*800*900 mm
1000*1000*1000 mm
External dimensions (D*W*H)
1250*900*1300 mm
950*900*1500 mm
1500*850*1650 mm
1750*1050*1850 mm
2100*1]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-4 UL94 Horizontal and Vertical Flame Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_4_UL94_Horizontal--11940578_11941787.html]]></link><description><![CDATA[tray, sample clamp, wrapping tissue 12g/m2 ~
30g/m2, steel wire mesh, height gauge, Cotton and etc.
Dimension of apparatus
1100mm(W)*700mm(D)*1300mm (H)
Power supply
AC220V, 50Hz, ≤500W
]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[Vertical Excitation Changeover Temperature Humidity Testing Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Vertical_Excitation_Changeover_Temperature_Humidity--11825687_11825688.html]]></link><description><![CDATA[system:Pretty appearance and convenient watering operation.2.Access to PC remote control and monitoring.3.Customization services.4.Observation window:Tempered glass with defroster, heating device, en]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Temperature Shock Chamber (Three-zone)]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Temperature_Shock_Chamber_Three_zone--11853101_11853495.html]]></link><description><![CDATA[dimensions (D*W*H)
1620*1460*2360mm
1720*1560*2460mm
2120*1820*2260mm
2420*2020*2660mm
High
temperature zone
Preheating
temperature upper limit
200℃
Heating time
R.T～+200℃: 40min (approximately]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[Glow-wire Test Apparatus]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Glow_wire_Test_Apparatus--11882688_11882702.html]]></link><description><![CDATA[Heating temperature: adjustable continuously within the range of 25~1100°C, the accuracy of temperature is 1°C, the resolution of temperature is ±3°C• Glow-wire time: 0.1-999.9s，±0.1s(time r]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Digital Halogen Moisture Analyzer]]></title><link><![CDATA[https://xmkwdz.en.ec21.com/Digital_Halogen_Moisture_Analyzer--10227578_10236597.html]]></link><description><![CDATA[35&amp;deg;C
Sensor
Load Cell
Display
LCD
Calibration
External
Pan Size
90mm
Dimensions
200 x 180 x 380mm
Weight
5.8Kg
Heating System
Halogen Lamp
Temperature Sensor
PT100
Temperature Range
40~199&amp;deg;C
]]></description><pubDate><![CDATA[20161204]]></pubDate></item>
<item>
<title><![CDATA[Glow-wire Test Apparatus]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Glow_wire_Test_Apparatus--9657760_11802295.html]]></link><description><![CDATA[Heating temperature: adjustable continuously within the range of ≤500-1000°C, the accuracy of temperature is 1°C, the resolution of temperature is ±3°C• Glowing time: 0.1-999.9s，±0.1S(time]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Horizontal and Vertical Flammability Tester UL94 IEC 60695]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Horizontal_and_Vertical_Flammability_Tester--5441143_9767620.html]]></link><description><![CDATA[heating from 100 ℃ to &amp;plusmn;5 ℃ up to 700 ℃ &amp;plusmn;3 ℃ in 
44 &amp;plusmn; 2 seconds and 54 seconds &amp;plusmn; 2 seconds. 
11.Temp. measuring thermocouple: two import armoured thermocouple type ]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[HSL-6001 Heat Seal Tester]]></title><link><![CDATA[https://systester18.en.ec21.com/HSL_6001_Heat_Seal_Tester--10834088_10841642.html]]></link><description><![CDATA[Heat jaw surface: 265mm × 12 mm (customized)
Heat jaws: 2, controlled independently
Gas source pressure: 0.05MPa ~ 1.1MPa (self-provide)
Gas source interface: Ф6mm
Outer dimension: 536 mm (L)×335 ]]></description><pubDate><![CDATA[20210625]]></pubDate></item>
<item>
<title><![CDATA[Quick Thermal Conductivity Meter QTM-700/QTM-710]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Quick_Thermal_Conductivity_Meter_QTM--8755030_8755121.html]]></link><description><![CDATA[35℃ Humidity : 85%RH or below (no condensation)Power supplyDC24V 5A (main unit), AC100-240V±10% 50/60Hz (AC adaptor)Dimensions262(W)×276(D)×158(H)mmWeightApprox. 4kgCE markingCE marking (EN61326]]></description><pubDate><![CDATA[20190329]]></pubDate></item>
<item>
<title><![CDATA[Large Capacity Constant Temperature Humidity Stability Test Chambers]]></title><link><![CDATA[https://annie0423.en.ec21.com/Large_Capacity_Constant_Temperature_Humidity--9938678_9938735.html]]></link><description><![CDATA[Heating up:
-40&amp;deg;C ~ +100&amp;deg;C within 45 min
Heating down:
20&amp;deg;C~ -20&amp;deg;Cwithin 40min
Interior dimension(W&amp;times;D&amp;times;H):
50&amp;times;60&amp;times;50cm
Exterior dimension(W&amp;times;D&amp;times;H):
102]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>