<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 40 5]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/40_5--2717/1/40 5.html]]></link><item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[5mm(L)X90mm(W)X40mm(H);
Equipment application scope:
1. Insulation performance testing of laparoscopic surgical forceps, separation forceps and other endoscopic instruments with power supply;
2. Exte]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[FLIR T840 Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/FLIR_T840_Thermal_Imaging_Camera--12045274_12045348.html]]></link><description><![CDATA[40 x 201 x 84 mm (5.5 x 7.9 x 3.3 in)CONNECTIONS &amp; COMMUNICATIONSCommunication Interfaces: USB 2.0, Bluetooth, Wi-FiStorage Media: Removable SD cardVideo Out: DisplayPort over USB Type-CMETERLiNK: Ye]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Laser Distance Measurer]]></title><link><![CDATA[https://holo1.en.ec21.com/Laser_Distance_Measurer--11942959_11942962.html]]></link><description><![CDATA[Features:
Measuring range is optional;
Accurate and stable distance measurement
Language customization is available;
Specifications:
Model Number
Z-40
Z-60
Z-80
Z-100
Z-120
Measurement Range
0.05~40M]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[Exit Device Durability Test Equipment]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Exit_Device_Durability_Test_Equipment--11987076_11989323.html]]></link><description><![CDATA[50
square steel tube and baking finish
1 test doors: about 40kg（up to 200kg，additional
load as requested）
c) 
Hinge plates: two sets of replaceable hinge plate.
d) 
Door closer mounting base: o]]></description><pubDate><![CDATA[20241122]]></pubDate></item>
<item>
<title><![CDATA[Digital Rail Corrugation Ruler]]></title><link><![CDATA[https://420621199211083365.en.ec21.com/Digital_Rail_Corrugation_Ruler--12024098_12024110.html]]></link><description><![CDATA[5
Accuracy
±0.05
Resolution
0.01
Repeat error
0.02
Working temperature
-5 - 40℃
APPLICATIONThis digital corrugation wear gauge is a direct reading measuring tool which is used straight vertical me]]></description><pubDate><![CDATA[20241113]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[ModelStudio Size (D*W*H)mmDimension（D*W*H）mmLRHS-101B-3LJ450×450×500Subject to contractual three-viewLRHS-225B-3LJ500×600×750temperature rangeA:-20℃～150℃ B:-40℃～150℃C:-60℃～150]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[Portable X Ray Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Portable_X_Ray_Flaw_Detector--11973711_11973712.html]]></link><description><![CDATA[5mA
Fluctuation
±2%
X-ray Tube
Focal Spot Size
0.8×0.8
1.0×2.0
1.0×3.0(Z)
0.8×0.8
1.0×2.0
1.0×3.0(Z)
1.5×1.5
1.0×2.0
1.0×3.5(Z)
Radiation Coverage
40°
360°×25°
360°×40°(Z)
40°
360°]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[Cuvettes&amp;Cuvettes(Glass)&amp;Cuvettes (Quartz)]]></title><link><![CDATA[https://biogene123.en.ec21.com/Cuvettes_Cuvettes_Glass_Cuvettes_Quartz--11963552_11963584.html]]></link><description><![CDATA[5mmglass10pcs/boxBCG-10Cuvette10mmglass10pcs/boxBCG-20Cuvette20mmglass10pcs/boxBCG-30Cuvette30mmglass10pcs/boxBCG-40Cuvette40mmglass10pcs/boxBCG-50Cuvette50mmglass10pcs/boxBCG-2-100Cuvette100mmglass4]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[2 Axis 2 Frame POD Multiple Spectral Electro Optic Camera Sensor 4.5kg]]></title><link><![CDATA[https://leadir.en.ec21.com/2_Axis_2_Frame_POD--11958808_11958803.html]]></link><description><![CDATA[5.5
°
Operating range
Identification distance for vehicles≥7km
Under visibility ≥ 
20km and relative humidity 
≤70%
Infrared Thermal Camera
Resolution
Longwave uncooled 640*512
Operating waveb]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[Walk in Temperature Humidity Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Walk_in_Temperature_Humidity_Test--11164019_11165139.html]]></link><description><![CDATA[5*2.25 m
4*3*2.4 m
4.5*3.2*2.4 m
Temperature Control mode
Balanced temperature &amp; humidity control (BTHC)
Performance 
Temperature range
-70/-40~+100℃ (high temperature:120℃,150℃ optional)
Humid]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Rail Cant Measuring Device]]></title><link><![CDATA[https://420625199907014021.en.ec21.com/Rail_Cant_Measuring_Device--11946179_11946261.html]]></link><description><![CDATA[5分钟内没有运行,系统将自动关闭。
规格
模型JG-SO1供电模式内置锂电池充电工作温度 -30° ～ +60°测量范围 ±1 ： 10 ～ ±1 ： 200运行电流40mA尺寸225*90*60m]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 IP5X and IP6X Sand Dustproof Test Chamber]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60529_IP5X_and_IP6X_Sand--11940576_11946391.html]]></link><description><![CDATA[500*500*500(L*D*H)
Outer dimension(mm)
950*720*1500(L*D*H)
Temperature range
RT+10~+40℃
Humidity
45%-75%
Wire diameter 
of metal net
50μm
Wire interval
75μm
Airflow velocity
≤ 
2.5m/s
Time rang]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[GS-SW6401725-80-U Scientific Deep-cooled SWIR Camera]]></title><link><![CDATA[https://gatherstar.en.ec21.com/GS_SW6401725_80_U_Scientific--11943440_11943922.html]]></link><description><![CDATA[GS -SW64017 2 5 -80-U Scientific Deep-cooled SWIR camera
F eatures
High sensitivity InGaAs FPA
640×512 pixel resolution
25um pixel size
Spectral range:0.9um~1.7um
Deep cooled to -80°C
Long time
No ]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Digital Screen Tension Tester]]></title><link><![CDATA[https://ame7788.en.ec21.com/Digital_Screen_Tension_Tester--9661329_9762827.html]]></link><description><![CDATA[40 N/cm
Resolution
0.1 
Operating Environment
Temperature: 0 ~ 40 ℃ Humidity: 10 ~ 90 %RH
Power Supply
4 x 1.5 V AAA Size (UM-4) Battery
Demensions
175 x 95 x 40 mm
Weight
490 g (Not Including Batt]]></description><pubDate><![CDATA[20240529]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[40°c ~+70°c
 Moisture and heat performance test,24hours. high temp. 55°c, low-temp 25°c, humidity 93%
 Short circuit current impact test, 16KA, 2 second
 Insulator Test: 1) Insulator res]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[Fluke 1587 FC Advanced Electrical Troubleshooting Kit]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_1587_FC_Advanced_Electrical--11927627_11927693.html]]></link><description><![CDATA[40 °C to 60 °C (-40 °F to 140 °F)Operating temperature-20 °C to 55 °C (-4 °F to 131 °F)Temperature coefficient0.05 x (specified accuracy) per °C for temperatures &lt;18 °C or &gt;28 °C (&lt;64 °F ]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[Directional Portable X Ray Flaw Detector NDT Machine]]></title><link><![CDATA[https://zyhjane00.en.ec21.com/Directional_Portable_X_Ray_Flaw--9951897_9951948.html]]></link><description><![CDATA[5
80-160
1.5
0.8×0.8
40+5°
19
15
225×225×585
XXQ-2005
100-200
2.0
1.5×1.5
40+5°
30
23
285×285×665
XXQ-2505
150-250
2.5
2.0×2.0
40+5°
40
35
320×320×730
XXQ-3005
170-300
3.0
2.3×2.3
40+5°]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[VC5000A Power Quality Analyzer]]></title><link><![CDATA[https://cqsellbest.en.ec21.com/VC5000A_Power_Quality_Analyzer--11925671_11925688.html]]></link><description><![CDATA[40-70Hz / 0.01Hz / ±0.03HzTrue RMS Voltage1.0-1000V / 0.1 / ±(0.5%+5dgt)True RMS Line Voltage1.0-2000V / 0.1 / ±(0.5%+5dgt)DC Voltage1.0-1000V / 0.1 / ±(1.0%+5dgt)True RMS Current10mA-9000A / 1mA]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[5 mV0.03% + 0.005 mV3.00000 V0.02% + 0.00005 V0.03% + 0.00005 V30.0000 V0.02% + 0.0005 V0.03% + 0.0005 V300.00 V0.05% + 0.05 V0.07% + 0.05 VVoltage AC3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% + 0.002 ]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD13 High Energy Shock Test System]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD13_High_Energy_Shock_Test--11098426_11099352.html]]></link><description><![CDATA[50
100
200
500
800
1000
2000
Table Size (mm)
500×500
600×600
800×800
1000×1000
1200×1200
1500×1500
2000×2000
Peak Acc. (g)
Half-Sine
10~1500
10~1000
10-1000
10-500
10-400
10-300
10-200
Post-Pe]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Gradient Heat Seal Tester for Flexible Packaging High Efficiency Heat Sealer in Lab Testing Machine]]></title><link><![CDATA[https://celtec.en.ec21.com/Gradient_Heat_Seal_Tester_for--9267519_9267617.html]]></link><description><![CDATA[50℃
Temp. Gradient ≤20℃
Deviation ±0.2℃
Sealing Time 0.1S~9999H
Sealing Pressure 0.15~0.7 MPa
Seal Jaws(mm) U:40*10 5PCS/L:330 1PCS 
Gas Input 0.7 MPa with Ф6 mm Pipe
Power AC 220V 50Hz
]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[Vertical Excitation Changeover Temperature Humidity Testing Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Vertical_Excitation_Changeover_Temperature_Humidity--11825687_11825688.html]]></link><description><![CDATA[5.It can be installed additional testing holes according to requirements.Product paraments: Model TH-80 TH-150 TH-225 TH-408 TH-800 TH-1000 Internal Dimension 400x500x400 500x600x500 600x750x500 600x]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Temperature Humidity Standard Environment Experiment Calibration Chamber Cabinet]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Temperature_Humidity_Standard_Environment_Experiment--11689458_11689464.html]]></link><description><![CDATA[40 RH to 60 RH only 15 minutes
* Fan speed regulation: inner cavity main circulation fan, using frequency conversion speed regulation control, through touch screen, set fan speed;
* Multiple protecti]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Temperature Shock Chamber (Three-zone)]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Temperature_Shock_Chamber_Three_zone--11853101_11853495.html]]></link><description><![CDATA[5J
HD-CTS3-10J
Internal volume
120L
210L
504L
900L
Internal
dimensions (D*W*H)
400*500*600mm
500*600*700mm
700*800*900mm
900*1000*1000 mm
External
dimensions (D*W*H)
1620*1460*2360mm
1720*1560*2460mm]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[FLIR T530 24 Thermal Cameras with 24 Degree Lens, 30Hz]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/FLIR_T530_24_Thermal_Cameras--11561118_11567071.html]]></link><description><![CDATA[54Product Weight2.9 LBSShipping Weight12.8 LBSData LoggingYesHTS/Schedule B Number9027.50.4020ECCN Number6A003.b.4.bCalibration IncludedFactory CalibrationBattery TypeLi-ionPower Supply Voltage120V/2]]></description><pubDate><![CDATA[20230930]]></pubDate></item>
<item>
<title><![CDATA[18650 Lithium Battery]]></title><link><![CDATA[https://chamglobal.en.ec21.com/18650_Lithium_Battery--11857535_11857537.html]]></link><description><![CDATA[CHAM offers a full selection of cylindrical battery cell solutions including lithium ion battery 18650 bulk
, 26650, 21700, and 32700, to big cylindrical cells like 32140, 40135, and 4680 series. A c]]></description><pubDate><![CDATA[20231023]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[5 °C (14 ºF to 113 ºF)Storage temperature range: –20 °C to 60 °C (–4 ºF to 140 ºF) with batteryStorage temperature range: –20 °C to 70 °C (–4 ºF to 158 ºF) without batteryRelative ]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[LY-30KGF Thrust Stand]]></title><link><![CDATA[https://wingflyingtech.en.ec21.com/LY_30KGF_Thrust_Stand--11428434_11428436.html]]></link><description><![CDATA[propulsion system.
Suggested Propulsion System
5-20kg thrust
Max Thrust
30KG
Max Propeller
40inch
Torque
20 N•M
Current
0-150A
Voltage
5-65V
RPM
60-150000 RPM
For more details please click here
]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[Intelligent Temperature Measuring Machine]]></title><link><![CDATA[https://auroraguoxia12.en.ec21.com/Intelligent_Temperature_Measuring_Machine--11599950_11770469.html]]></link><description><![CDATA[50,000 face photos (less than 400KB), 10 million recognition records (0.45KB), and 200,000 on-site captured photos;
（b）The local area network device supports simultaneous storage of 30,000 face p]]></description><pubDate><![CDATA[20230417]]></pubDate></item>
<item>
<title><![CDATA[ZHLB Bell Porver]]></title><link><![CDATA[https://royreal.en.ec21.com/ZHLB_Bell_Porver--11907986_11909901.html]]></link><description><![CDATA[5%，≤0.3%
Flow Range
ZHLB-1000(60m3/h）
ZHLB-2000(120m3/h）
Flowmeter Specification
ZHLB-1000(DN50、DN40、DN32、DN25）
ZHLB-2000(DN80、DN50、DN40、DN32、DN25）
Gas Meter
G6～G100
Tempe]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[China Enviclone Programmable Walk in Large Size Salt Fog Spray Corrosion Test Chamber]]></title><link><![CDATA[https://enviclonetestchamber.en.ec21.com/China_Enviclone_Programmable_Walk_in--11887759_11887763.html]]></link><description><![CDATA[50 021, DIN EN ISO 9227-2006, CNS 4159, CASS, JIS H8502, IEC 68-2-52etc.
Brief Specification Temperature Ranges
0°C~100°C (-20~100°C, -40~100°C, -70~100°C)Relative Humidity20%~98% R.H.Pressure b]]></description><pubDate><![CDATA[20240113]]></pubDate></item>
<item>
<title><![CDATA[Temperature and Humidity Testing Chamber]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/Temperature_and_Humidity_Testing_Chamber--11847960_11847964.html]]></link><description><![CDATA[50(AF)THC-225(AF)THC-408(AF)THC-800(AF)THC-1000(AF) 内部尺寸宽x高x深（毫米）400x500x400500x600x500 600x750x500600x850x8001000x1000x8001000x1000x1000 外部尺寸宽x高x深（毫米）950x]]></description><pubDate><![CDATA[20231107]]></pubDate></item>
<item>
<title><![CDATA[LITE800 Industrial SLA 3D Printer]]></title><link><![CDATA[https://uniontech3d.en.ec21.com/LITE800_Industrial_SLA_3D_Printer--11706631_11807017.html]]></link><description><![CDATA[40 VAC, 50/60 Hz, Single phase
Rated Power
2.8 kVA
Systems Control
Closed-loop
Temperature Range
72–79 °F (22–26 °C)
Maximum Change Rate
1 °C/hour
Relative Humidity
&lt; 40%
Machine Size (W x D x]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Low Temperature Brookfield Viscosity Tester ASTM D2983]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Low_Temperature_Brookfield_Viscosity_Tester--11718430_11718461.html]]></link><description><![CDATA[40±0.1℃
5. 
Speed range: 0.5~60r/min
6. 
Power of the whole machine: 800W
7. 
Working power supply: AC220,240V 50,60HZ
8. 
Operation mode: touch screen operation
9. 
Lifting mode: automatic liftin]]></description><pubDate><![CDATA[20230201]]></pubDate></item>
<item>
<title><![CDATA[New NDT Systems Raptor Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New_NDT_Systems_Raptor_Flaw--11801594_11801615.html]]></link><description><![CDATA[5MHz to 30.0MHz
Cable length6ft (1.83m) standardPower SourcePower SourceSingle Li-Ion battery
Battery life8 hoursDisplayDisplay typeSunreadable Color VGA 60Hz
Display size640 x 480 pixels, 3.40in. x ]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Futina Metal Electrical Power Distribution Box B Series]]></title><link><![CDATA[https://futinaswitch.en.ec21.com/Futina_Metal_Electrical_Power_Distribution--11637911_11862326.html]]></link><description><![CDATA[5-7 ways, 8-10 ways, 11-14 ways, 15-20 ways,22-28 ways. 30-40 ways
Lead time
30-45 days
Place of Origin
Shunde, Guangdong, China
Brand name
FUTINA &amp; OEM &amp; ODM
Model Number
FTB
Modules
4, 7, 10, 14, 2]]></description><pubDate><![CDATA[20231103]]></pubDate></item>
<item>
<title><![CDATA[MOSIP Certified Fingerprint Scanner]]></title><link><![CDATA[https://miaxis2024.en.ec21.com/MOSIP_Certified_Fingerprint_Scanner--11895938_11895942.html]]></link><description><![CDATA[54 dustproof and waterproof
Biometric Thumb Machine Specification:
Specification
Detail
Sensor type
Optical
Resolution
500dpi
Active platen area
15.24mm x 20.32mm
Image Size
300*400 pixel
FAP (finger]]></description><pubDate><![CDATA[20240131]]></pubDate></item>
<item>
<title><![CDATA[Fluke PTI120 Pocket Thermal Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_PTI120_Pocket_Thermal_Camera--11790575_11793452.html]]></link><description><![CDATA[50° H x 38° VDistance to spot130:1Temperature measurement range (not calibrated below -10 °C)-20 °C to 400 °CFocus systemFixed focus, minimum focus distance 22.8 cmUSBMini USB used to transfer i]]></description><pubDate><![CDATA[20230519]]></pubDate></item>
<item>
<title><![CDATA[Advantest R3172 Spectrum Analyzer 9KHz - 26.5GHz]]></title><link><![CDATA[https://mark225.en.ec21.com/Advantest_R3172_Spectrum_Analyzer_9KHz--11832361_11835474.html]]></link><description><![CDATA[The R3172 and R3182 are low-cost portable
spectrum analyzers capable of performing
direct input measurements at a maximum
frequency 26.5 and 40 GHz respectively.
Adopting newly designed RF circuitry,]]></description><pubDate><![CDATA[20230819]]></pubDate></item>
<item>
<title><![CDATA[High Accuracy 18650/26650/32650/21700 Battery 1-24 Series Bms PCB Testing Machine Bms Tester]]></title><link><![CDATA[https://aitop2018.en.ec21.com/High_Accuracy_18650_26650_32650--11585406_11585408.html]]></link><description><![CDATA[5-5V
±5mV
7
Overcharge/Overdischarge voltage
0.5-5V
±5mV
8
Overcharge protection current
0-40A
±0.1A
9
Overdischarge protection current
0-120A
±0.1A
10
Equilibrium open voltage
0.5-5V
±5mV
11
Eq]]></description><pubDate><![CDATA[20220611]]></pubDate></item>
<item>
<title><![CDATA[High Purity Gas Generator, Hydrogen Generator, Nitrogen Generator]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/High_Purity_Gas_Generator_Hydrogen--11907876_11909357.html]]></link><description><![CDATA[500
Output pressure (MPa) 0.4 (factory set at 0.3) adjustable
Working power supply 110/220V ± 10%; 50/60Hz ± 5%
Maximum power (W) 200
Environmental conditions and temperature: 10-40 ℃; Relative h]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[Salt Spray Test | Salt Spray Test Chamber]]></title><link><![CDATA[https://15317383997.en.ec21.com/Salt_Spray_Test_Salt_Spray--11812738_11858086.html]]></link><description><![CDATA[52, ASTM-B368, MIL-STD-202, EIA-364-26, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.
ModelWork Room Size (mm)Exterior Size (mm)VoltagePower (KW)YWX/Q-150600x450x4001100x7]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[JB-300  150J / 300J Manual Pendulum Charpy Impact Tester]]></title><link><![CDATA[https://wanchen123.en.ec21.com/JB_300_150J_300J_Manual--11774583_11774587.html]]></link><description><![CDATA[50J (1J/Grid); 0-300J(2J/Grid)
Impact Energy : 150J, 300J
Impact Speed 5.2 m/s
Pre-rising Angle Of The Pendulum: 135°
Specimen Bearer Span: 40+0.2mm
Round Angle Of The Jaw : R1.0-1.5mm
Round Angle O]]></description><pubDate><![CDATA[20230529]]></pubDate></item>
<item>
<title><![CDATA[100k - 10T Micro Signal Type Tester Resistance Capacitance and Inductance Tester]]></title><link><![CDATA[https://techmizetest.en.ec21.com/100k_10T_Micro_Signal_Type--11890824_11890825.html]]></link><description><![CDATA[40℃≤90%RHPower Requirement90～121V AC (60Hz)or 198～242V AC (50Hz)Power50VAVolume235mmX104mmX360mmWeight3.6kg AccessaryStandardAccessories nameModel Test Cable at both EndTH26004B OptionalAcces]]></description><pubDate><![CDATA[20240119]]></pubDate></item>
<item>
<title><![CDATA[Multi-function Optical Fiber Light Source CEL-FES300 Photocatalysis]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Multi_function_Optical_Fiber_Light--11446837_11446865.html]]></link><description><![CDATA[4000 Determination）
300nm~2500nm (No ozone)Working spot diameter(Optional continuous adjustment accessories)Above 60mmOptical fiber output square spot10*10mm—60*60mm，Adjust by converging lensOu]]></description><pubDate><![CDATA[20221027]]></pubDate></item>
<item>
<title><![CDATA[Laser Measuring Tape 40m Digit Tape Measure Laser Digital Laser Measure Tape]]></title><link><![CDATA[https://ananke2023.en.ec21.com/Laser_Measuring_Tape_40m_Digit--11749666_11749734.html]]></link><description><![CDATA[5mSize of Rulerwidth 19mm,thickness 120 wm, length 5mOperation Temperature0～40°C / 32～104°FStorage Temperature-20～60°C / -4～140°FSingle MeasurementYesLaser classclass II,650nm,＜1mWDust ]]></description><pubDate><![CDATA[20230316]]></pubDate></item>
<item>
<title><![CDATA[Gold Supplier Programmable Constant Temperature and Humidity Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Gold_Supplier_Programmable_Constant_Temperature--11372570_11372574.html]]></link><description><![CDATA[Technical parameters 1. Inner box size (W*H*D) : 400*500*400mm(80L), 500*600*500mm(150L), 500*750*600mm(225L)
600 * 850 * 800 mm (408 l), 1000 * 1000 * 800 mm (800 l),2. Temperature range: -20ºC(-40]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[YFT-D300 Pressure Relief Valve Test Bench for Safety Valve Pressure Calibration and Sealing Test]]></title><link><![CDATA[https://king3834656.en.ec21.com/YFT_D300_Pressure_Relief_Valve--11745449_11747554.html]]></link><description><![CDATA[500 mm. After adjusting installation level, use concrete to fix the foot bolts.2. Inject 30-40# hydraulic oil into the oil tank and the oil volume cannot be lower than the lowest limit of the oil lev]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[Carbon Dioxide Volume Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Carbon_Dioxide_Volume_Tester--11854816_11854820.html]]></link><description><![CDATA[0.01KPa 
Shaking Speed Adjustable
Piercing Speed 5mm/s (other available)
Sample Height ≤ 350mm (other available)
Temp. range 0 ~ 30 ℃
Shaking time 40s (other available)
Resolution 0.1 ℃
]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[Portable Chloride-Meter for Fresh Concrete]]></title><link><![CDATA[https://dymeter.en.ec21.com/Portable_Chloride_Meter_for_Fresh--26285_1239637.html]]></link><description><![CDATA[500%
Accuracy: &amp;plusmn;10%(Chloride) of
Reading / &amp;plusmn;1&amp;deg;C(Temp.)
Operation Temperature: 0&amp;deg;C ~ 40&amp;deg;C
Resolution: 0.0001(Chloride)
Power: 1&gt;DC 9V Adapter 2&gt;Ni-MH Battery(Rechargeable) 1.]]></description><pubDate><![CDATA[20180303]]></pubDate></item>

</channel>
</rss>