<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 40]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/40--2717/1/40.html]]></link><item>
<title><![CDATA[40m 20HZ 1mm Accuracy COM RXTX Serial Port TTL Digital Output Raspberry Pi Laser Distance Sensor]]></title><link><![CDATA[https://lasersensor2003.en.ec21.com/40m_20HZ_1mm_Accuracy_COM--11950652_11976847.html]]></link><description><![CDATA[LDK-40 is a high-precision laser ranging module, independently developed by Chengdu Meskernel Integrated Technology Co., Ltd. The extremely small and lightweight features (48*26*13mm, 9g) make it sui]]></description><pubDate><![CDATA[20240729]]></pubDate></item>
<item>
<title><![CDATA[KRD40 Zero-distance Drop Test System]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD40_Zero_distance_Drop_Test--11098426_11099460.html]]></link><description><![CDATA[KRD40 Zero-distance Drop Test SystemKRD40 series drop tester, mainly simulates the resistance to drop
and impact of large and heavy packaging products. Its strong power system and
unique sample holde]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Laser Measuring Tape 40m Digit Tape Measure Laser Digital Laser Measure Tape]]></title><link><![CDATA[https://ananke2023.en.ec21.com/Laser_Measuring_Tape_40m_Digit--11749666_11749734.html]]></link><description><![CDATA[40m
Product Name2-in-1 Laser TapeModelCMultiple Measurement ModesDistance/Area/Volume/Single/Max&amp;Min/continuous measurement and indirect measurement by Pythagorean theoremMeasuring Range of Tape Meas]]></description><pubDate><![CDATA[20230316]]></pubDate></item>
<item>
<title><![CDATA[PP40 Filter Funnel - Microbial Filtration]]></title><link><![CDATA[https://shenzhilin.en.ec21.com/PP40_Filter_Funnel_Microbial_Filtration--11772711_6615162.html]]></link><description><![CDATA[Filter Funnel - PP material
Feature:
-Max.Capacity of Funnel: 270ml.
-Five annular scales marked with real line and dotted line alternately, easy to observe.
-Scales of funnel: 50, 100, 150, 200, 250]]></description><pubDate><![CDATA[20230721]]></pubDate></item>
<item>
<title><![CDATA[40/50mm Steel Pipe Steel Tube Steel Bar Rebar Materials Power Driven Bending Testing Machine]]></title><link><![CDATA[https://lgtester789.en.ec21.com/40_50mm_Steel_Pipe_Steel--10000315_10050716.html]]></link><description><![CDATA[Overview
GW-40B Type Steel Bar Bending Testing Machines is special equipments which process cold bend tests and plane rebend tests. Its main technical parameters meet GB1499.2-2007 , YB/T5126-2003 an]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[ZXUD - 40 Digital Truecolor Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ndtchina.en.ec21.com/ZXUD_40_Digital_Truecolor_Ultrasonic--6581053_6161468.html]]></link><description><![CDATA[ZXUD - 40 digital truecolor ultrasonic flaw detector
Function characteristics
Powerful digital processing technology and accurate simulation technology integration; High performance, high reliability]]></description><pubDate><![CDATA[20140520]]></pubDate></item>
<item>
<title><![CDATA[Fluke 87V Industrial Multimeter 2025]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_87V_Industrial_Multimeter_2025--11790575_11793411.html]]></link><description><![CDATA[40.0 °C – 260 °C–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greaterConductanceMaximum conductance60.00 nSAccuracy±(1.0% + 10)Maximum resolution0.01 nSDiodeRange3 VResolution1 mVAccuracy]]></description><pubDate><![CDATA[20250321]]></pubDate></item>
<item>
<title><![CDATA[Milk Analyzer Master Classic- Milkotester Ltd.]]></title><link><![CDATA[https://milkotester.en.ec21.com/Milk_Analyzer_Master_Classic_Milkotester--10736730_11057015.html]]></link><description><![CDATA[40sec./30sec.Master LM2 can be equipped with second peristaltic pump for automatic cleaning.Master LM2 is comfortable and reliable milk analyzer with sophisticated sensor with long life and better pr]]></description><pubDate><![CDATA[20250305]]></pubDate></item>
<item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[40mm(H);
Equipment application scope:
1. Insulation performance testing of laparoscopic surgical forceps, separation forceps and other endoscopic instruments with power supply;
2. External insulation]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Flir C5 - Compact Thermal Camera with Wi-Fi]]></title><link><![CDATA[https://toolshed.en.ec21.com/Flir_C5_Compact_Thermal_Camera--12045274_12045319.html]]></link><description><![CDATA[400°C (-4 to 752°F)AccuracyAt ambient temp. 15 to 35°C (59 to 95°F) and object temp. above 0°C (32°F)0 to 100°C (32 to 212°F): ±3°C (±5.5°F)100 to 400°C (212 to 752°F): ±3%Measurement ]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[WDLYCH/WDLHCN CCS Marine Analog Panel Current Meter/Ammeter for Switchboards]]></title><link><![CDATA[https://jade900920.en.ec21.com/WDLYCH_WDLHCN_CCS_Marine_Analog--11663243_12026218.html]]></link><description><![CDATA[40-270°
Temperature
-13-33℃, 100% comply with accuracy class
Technical Standards
GB/T7676-1998
Environment
GB8355-1987
Safety Standards
GB4793-20
Working Temperature
-40℃-65℃
Options: 
1. Tran]]></description><pubDate><![CDATA[20241227]]></pubDate></item>
<item>
<title><![CDATA[Laser Distance Meter 100m]]></title><link><![CDATA[https://holo1.en.ec21.com/Laser_Distance_Meter_100m--11942959_11943117.html]]></link><description><![CDATA[40
Y-60
Y-80
Y-100
Measurement Range
0.05~40M
0.05~60M
0.05~80M
0.05~100M
Measurement Accuracy
±2mm
Laser Class
Ⅱ
Laser Diode
635nm , P＜1mW
Battery Life
＞10000 times
Working Temperature
-10℃]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[Exit Device Durability Test Equipment]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Exit_Device_Durability_Test_Equipment--11987076_11989323.html]]></link><description><![CDATA[40kg（up to 200kg，additional
load as requested）
c) 
Hinge plates: two sets of replaceable hinge plate.
d) 
Door closer mounting base: one set of wooden block for
surface mounting. One set of adj]]></description><pubDate><![CDATA[20241122]]></pubDate></item>
<item>
<title><![CDATA[Digital Rail Corrugation Ruler]]></title><link><![CDATA[https://420621199211083365.en.ec21.com/Digital_Rail_Corrugation_Ruler--12024098_12024110.html]]></link><description><![CDATA[40℃
APPLICATIONThis digital corrugation wear gauge is a direct reading measuring tool which is used straight vertical measurement method. It is mainly used for measuring rail top surface and positi]]></description><pubDate><![CDATA[20241113]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[ModelStudio Size (D*W*H)mmDimension（D*W*H）mmLRHS-101B-3LJ450×450×500Subject to contractual three-viewLRHS-225B-3LJ500×600×750temperature rangeA:-20℃～150℃ B:-40℃～150℃C:-60℃～150]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale DN200 Portable Pneumatic Safety Relief Valve Test Bench for Flanged Valves]]></title><link><![CDATA[https://shineeast2024.en.ec21.com/Hot_Sale_DN200_Portable_Pneumatic--11996822_12014365.html]]></link><description><![CDATA[40 gas booster pump
Clamping system:
The power of the clamping device is provided by a manual hydraulic(oil) pump to provide clamping pressure.
System composition:
It consists mainly of high pressure]]></description><pubDate><![CDATA[20241007]]></pubDate></item>
<item>
<title><![CDATA[GF018A Clamp Type Multimeter Calibrator]]></title><link><![CDATA[https://gfuvegroup.en.ec21.com/GF018A_Clamp_Type_Multimeter_Calibrator--11546876_11999025.html]]></link><description><![CDATA[40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source;
APPLICATION■ Power plant;
■ Universities;
■ Panel manufacturer;
■ Res]]></description><pubDate><![CDATA[20240905]]></pubDate></item>
<item>
<title><![CDATA[Wireless LoRaWAN Temperature and Vibration Sensor Industrial LoRa IoT Solution for Smart Industry]]></title><link><![CDATA[https://winext2024.en.ec21.com/Wireless_LoRaWAN_Temperature_and_Vibration--11976761_11977241.html]]></link><description><![CDATA[40~125 ℃;
Ø Temperature Accuracy: ±0.1℃ (At stable temperature conditions);
Ø Explosion-proof design;
Ø Ultra low power consumption;
Ø Mounting Type: Bolt, Magnetic.
Product Image
parameter
]]></description><pubDate><![CDATA[20240730]]></pubDate></item>
<item>
<title><![CDATA[Surface Roughness Gauge]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Surface_Roughness_Gauge--11973711_11973717.html]]></link><description><![CDATA[error
±(7-10)%
Variability
&lt;6%
Data Storage
100 groups
Power
Rechargeable li-battery
Working temperature
-20℃～40℃
Relative humidity
&lt;90%
Size
158mmx63.5mmx46mm
Weight of Host
0.3kg
]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[Additel ADT878-160-NO-220V]]></title><link><![CDATA[https://wisnuprecision12.en.ec21.com/Additel_ADT878_160_NO_220V--11972561_11972570.html]]></link><description><![CDATA[Reference Dry Well Calibrator, -40 Degrees C to 160 Degrees C, No Insert, 220VReference level performance in accuracy, stability and uniformityQuick to temperatureTwo-channel readout measures RTDs an]]></description><pubDate><![CDATA[20240722]]></pubDate></item>
<item>
<title><![CDATA[Cuvettes&amp;Cuvettes(Glass)&amp;Cuvettes (Quartz)]]></title><link><![CDATA[https://biogene123.en.ec21.com/Cuvettes_Cuvettes_Glass_Cuvettes_Quartz--11963552_11963584.html]]></link><description><![CDATA[40Cuvette40mmglass10pcs/boxBCG-50Cuvette50mmglass10pcs/boxBCG-2-100Cuvette100mmglass4pcs/boxBCG-1-100Cuvette100mmglass1pcs/box
Description
Cuvette is a kind of equipment for spectral analysis. It is ]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[2 Axis 2 Frame POD Multiple Spectral Electro Optic Camera Sensor 4.5kg]]></title><link><![CDATA[https://leadir.en.ec21.com/2_Axis_2_Frame_POD--11958808_11958803.html]]></link><description><![CDATA[40*512
Operating waveband Range
8-12μm
FOV
7.3° 
x 5.8
°(±5%)
Focal Length
60mm at F1.0
Detection Range
For humans(0.5m x 1.8m)≥1.8km,for vehicles(4m x 6m)≥4.0km
Identification Range
For huma]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[108L Salt Spray Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/108L_Salt_Spray_Chamber--11164019_11164134.html]]></link><description><![CDATA[400 mm
600*900*500 mm
800*1200*500 mm
1000*1600*500 mm
1200*2000*600 mm
External dimensions (D*W*H)
672*1150*1090 mm
842*1450*1200 mm
1240*2080*1285 mm
1450*2480*1520 mm
1650*2900*1550 mm
Lab Tempera]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Analogue Rail Offset Scale Ruler]]></title><link><![CDATA[https://420625199907014021.en.ec21.com/Analogue_Rail_Offset_Scale_Ruler--11946179_11946282.html]]></link><description><![CDATA[工作边 直股铁路 以及 封闭铁路 工作边缘。 
规格
模型Lg-zjc类型横尺物质的铝合金尺寸(升x宽x高)(毫米)1710*35*40测量范围100-1400mm指示错误≤± 0.4mm
]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 IP5X and IP6X Sand Dustproof Test Chamber]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60529_IP5X_and_IP6X_Sand--11940576_11946391.html]]></link><description><![CDATA[40℃
Humidity
45%-75%
Wire diameter 
of metal net
50μm
Wire interval
75μm
Airflow velocity
≤ 
2.5m/s
Time range
0~999H(adjustable)
Vibration Time
0-999H(adjustable)
Time Accuracy
±1s
Dust conce]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[Gear Measuring Machine for Worm Wheel Rotary Table,Bevel Gear,]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Gear_Measuring_Machine_for_Worm--11944568_11945231.html]]></link><description><![CDATA[40 
The maximum outer diameter of the tested gear（㎜）
300 
450
650 
800
1000 
1200 
Measurable spiral angle range
0～90° 
Distance between top and bottom tips（㎜）
10～500 
10～800
10～]]></description><pubDate><![CDATA[20240531]]></pubDate></item>
<item>
<title><![CDATA[GS-SW6401725-80-U Scientific Deep-cooled SWIR Camera]]></title><link><![CDATA[https://gatherstar.en.ec21.com/GS_SW6401725_80_U_Scientific--11943440_11943922.html]]></link><description><![CDATA[GS -SW64017 2 5 -80-U Scientific Deep-cooled SWIR camera
F eatures
High sensitivity InGaAs FPA
640×512 pixel resolution
25um pixel size
Spectral range:0.9um~1.7um
Deep cooled to -80°C
Long time
No ]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Digital Screen Tension Tester]]></title><link><![CDATA[https://ame7788.en.ec21.com/Digital_Screen_Tension_Tester--9661329_9762827.html]]></link><description><![CDATA[40 N/cm
Resolution
0.1 
Operating Environment
Temperature: 0 ~ 40 ℃ Humidity: 10 ~ 90 %RH
Power Supply
4 x 1.5 V AAA Size (UM-4) Battery
Demensions
175 x 95 x 40 mm
Weight
490 g (Not Including Batt]]></description><pubDate><![CDATA[20240529]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[40°c ~+70°c
 Moisture and heat performance test,24hours. high temp. 55°c, low-temp 25°c, humidity 93%
 Short circuit current impact test, 16KA, 2 second
 Insulator Test: 1) Insulator res]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[Multifunction Strength Tester]]></title><link><![CDATA[https://198358.en.ec21.com/Multifunction_Strength_Tester--4030105_7499787.html]]></link><description><![CDATA[parameters 
Maximum pullout force of the detector 40kN
Work the piston stroke 10mm
Chassis fulcrum diameter 120mm
Minimum reading: 0.01kN
Indication error: Less than ± 2% F.S
Weight: 4kg 
]]></description><pubDate><![CDATA[20240430]]></pubDate></item>
<item>
<title><![CDATA[Fluke 1587 FC Advanced Electrical Troubleshooting Kit]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_1587_FC_Advanced_Electrical--11927627_11927693.html]]></link><description><![CDATA[40 °C to 60 °C (-40 °F to 140 °F)Operating temperature-20 °C to 55 °C (-4 °F to 131 °F)Temperature coefficient0.05 x (specified accuracy) per °C for temperatures &lt;18 °C or &gt;28 °C (&lt;64 °F ]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[Directional Portable X Ray Flaw Detector NDT Machine]]></title><link><![CDATA[https://zyhjane00.en.ec21.com/Directional_Portable_X_Ray_Flaw--9951897_9951948.html]]></link><description><![CDATA[40+5°
19
15
225×225×585
XXQ-2005
100-200
2.0
1.5×1.5
40+5°
30
23
285×285×665
XXQ-2505
150-250
2.5
2.0×2.0
40+5°
40
35
320×320×730
XXQ-3005
170-300
3.0
2.3×2.3
40+5°
50
45
345×345×830
M]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[Sonic Nozzle Gas Meter Test Bench]]></title><link><![CDATA[https://tnmacalibration.en.ec21.com/Sonic_Nozzle_Gas_Meter_Test--11926262_11926265.html]]></link><description><![CDATA[Sonic nozzle gas meter test bench
is used to test domestic gas meter and industrial gas meter from G1.6 to G4.0, G6.to G40,with flow rate from 0.016m³/h to 6.0m³/h,0.06m³/h to 65m³/h.
Gas meter t]]></description><pubDate><![CDATA[20240417]]></pubDate></item>
<item>
<title><![CDATA[VC5000A Power Quality Analyzer]]></title><link><![CDATA[https://cqsellbest.en.ec21.com/VC5000A_Power_Quality_Analyzer--11925671_11925688.html]]></link><description><![CDATA[40-70Hz / 0.01Hz / ±0.03HzTrue RMS Voltage1.0-1000V / 0.1 / ±(0.5%+5dgt)True RMS Line Voltage1.0-2000V / 0.1 / ±(0.5%+5dgt)DC Voltage1.0-1000V / 0.1 / ±(1.0%+5dgt)True RMS Current10mA-9000A / 1mA]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[Drop Test Machine]]></title><link><![CDATA[https://cmetechnology.en.ec21.com/Drop_Test_Machine--11925572_11925584.html]]></link><description><![CDATA[40 Zero Distance Drop Test Machine 
KRD41 Small Drop Test Machine 
KRD42 Double Lift Zero Distance Drop Test Machine 
HOW TO CHOOSE DROP TEST MACHINES?
01
KRD40 series zero-distance drop tester
KRD40]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[40 Hz to 500 Hz) / 0.001 V 0.5% + 0.002 V1.0% + 0.004 V30.00 V (40 Hz to 500 Hz) / 0.01 V0.5% + 0.02 V1.0% + 0.04 V300.0 V (40 Hz to 500 Hz) / 0.1 V0.5% + 0.2 V1.0% + 0.2 VCurrent DC30.000 mA 0.01% +]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Gradient Heat Seal Tester for Flexible Packaging High Efficiency Heat Sealer in Lab Testing Machine]]></title><link><![CDATA[https://celtec.en.ec21.com/Gradient_Heat_Seal_Tester_for--9267519_9267617.html]]></link><description><![CDATA[Gradient ≤20℃
Deviation ±0.2℃
Sealing Time 0.1S~9999H
Sealing Pressure 0.15~0.7 MPa
Seal Jaws(mm) U:40*10 5PCS/L:330 1PCS 
Gas Input 0.7 MPa with Ф6 mm Pipe
Power AC 220V 50Hz
]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[Octane Testing Engine Waukesha Cfr ASTM D2699 D2700]]></title><link><![CDATA[https://sinpar.en.ec21.com/Octane_Testing_Engine_Waukesha_Cfr--9761103_11911863.html]]></link><description><![CDATA[40 -120 octane number range.
Octane Testing Engine Applications
FTC-M2 Octane Testing Engine applies to the user who has the requirements of wide source test samples, large test quantity, long contin]]></description><pubDate><![CDATA[20240314]]></pubDate></item>
<item>
<title><![CDATA[WF-CO-30KGF Coaxial Thrust Stand]]></title><link><![CDATA[https://wingflyingtech.en.ec21.com/WF_CO_30KGF_Coaxial_Thrust--11428434_11428439.html]]></link><description><![CDATA[40 inch propeller. The distance between the propellers can be adjustable with the sliders.
Suggested Propulsion System
5-20kg thrust
Max Thrust
30KG
Max Propeller
40inch
Torque
20 N•M
Current
0-150]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[TEKON600 Turns Ratio Meter]]></title><link><![CDATA[https://tekon1.en.ec21.com/TEKON600_Turns_Ratio_Meter--11010564_11012592.html]]></link><description><![CDATA[40Vac and 100Vac (optional), enabling you to measure a variety
of transformers. 
It
uses the IEEE C57.12.90 measurement method and accurately measures the voltage
at the transformer’s winding at no]]></description><pubDate><![CDATA[20201231]]></pubDate></item>
<item>
<title><![CDATA[Humidity &amp; Temperature Sensor Probe(RS485, Voltage, Current Out)]]></title><link><![CDATA[https://sentrionkorea.en.ec21.com/Humidity_Temperature_Sensor_Probe_RS485--11545348_11353797.html]]></link><description><![CDATA[40°C – 60°C
■ Accuracy : ±3%RH (0% ~ 100%RH) / ±1.0°C (0°C – 60°C)
■ Supply Voltage : 12V, 24VDC
■ Operation Humidity / Temperature : 0% ~ 100%RH / -40°C ~ 60°C
■ IP rating : IP6]]></description><pubDate><![CDATA[20220401]]></pubDate></item>
<item>
<title><![CDATA[Multi-function Optical Fiber Light Source CEL-FES300 Photocatalysis]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Multi_function_Optical_Fiber_Light--11446837_11446865.html]]></link><description><![CDATA[4000 Determination）
300nm~2500nm (No ozone)Working spot diameter(Optional continuous adjustment accessories)Above 60mmOptical fiber output square spot10*10mm—60*60mm，Adjust by converging lensOu]]></description><pubDate><![CDATA[20221027]]></pubDate></item>
<item>
<title><![CDATA[Cold and Hot Shock Test Box / Cold and Hot Impact Tester]]></title><link><![CDATA[https://lituotest.en.ec21.com/Cold_and_Hot_Shock_Test--11372570_11372577.html]]></link><description><![CDATA[Technical parameters 1. Inner box size (W*H*D) : 500*400*400mm(80L)2. Outer box size (W*H*D) : 1480*1900*1550mm3. Temperature range :(-45ºC, -55ºC, -65ºC, -70ºC) ~ 150ºC4. Temperature range of h]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[YFT-D300 Pressure Relief Valve Test Bench for Safety Valve Pressure Calibration and Sealing Test]]></title><link><![CDATA[https://king3834656.en.ec21.com/YFT_D300_Pressure_Relief_Valve--11745449_11747554.html]]></link><description><![CDATA[40# hydraulic oil into the oil tank and the oil volume cannot be lower than the lowest limit of the oil level gauge.3. Turn on the power supply, press the &quot;On button&quot; of the oil pump, check whether t]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[Carbon Dioxide Volume Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Carbon_Dioxide_Volume_Tester--11854816_11854820.html]]></link><description><![CDATA[40 seconds ➔ Recording the stabilized 
MPa pressure (while measuring liquid temperature) ➔ Obtaining the carbon 
dioxide gas capacity test results.
Technical Features 
1.This unit is under precis]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[Portable Chloride-Meter for Fresh Concrete]]></title><link><![CDATA[https://dymeter.en.ec21.com/Portable_Chloride_Meter_for_Fresh--26285_1239637.html]]></link><description><![CDATA[40&amp;deg;C
Resolution: 0.0001(Chloride)
Power: 1&gt;DC 9V Adapter 2&gt;Ni-MH Battery(Rechargeable) 1.2V x 6 Pcs
Battery Life: Abt.6 months based on 5 minutes use per day
Size/Weight:80 x 190 x 40mm /Abt.450g]]></description><pubDate><![CDATA[20180303]]></pubDate></item>
<item>
<title><![CDATA[UL746A Tracking Index Test Device]]></title><link><![CDATA[https://pegogroup.en.ec21.com/UL746A_Tracking_Index_Test_Device--11405200_11425193.html]]></link><description><![CDATA[40mm±5mm), length≥12mm, Angle of chisel-edged: 30°±2°
Electrode distance
4.0mm±0.01mm, angle: 60°±5°
Electrode pressure
1.00±0.001N
Electrode distance
4.0mm ± 0.01mm
Angle
60°±5
Electro]]></description><pubDate><![CDATA[20210805]]></pubDate></item>
<item>
<title><![CDATA[Walk-in High Low Temperature (Humidity) Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Walk_in_High_Low_Temperature--11853101_11853655.html]]></link><description><![CDATA[40℃～+100℃ (high temperature +120℃, +150℃ optional)
Humidity range
20%～98%R.H.
Temperature fluctuation
≤±0.5℃
Temperature uniformity
≤2.0℃
Temperature deviation
±2.0℃
Humidity ]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[YES-2000 Digital Display Compression Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/YES_2000_Digital_Display_Compression--4048548_4096491.html]]></link><description><![CDATA[piston stroke: 40mm;
8) loading rate: 0-40KN/s, adjustable;
9) dim. of main machine (L*W*H) (mm): 820*550*1300mm;
10)power supply: 380V&amp;plusmn;10%, 50Hz;
11)power (kw): 1.5;
12)weight: about 650kg.
]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[Plug Humidity Indicator]]></title><link><![CDATA[https://yukic.en.ec21.com/Plug_Humidity_Indicator--3739735_10562300.html]]></link><description><![CDATA[customers&amp;#39; requirements 
Specifications as below: 
single dot from RH 8%-80% 
three dots:RH 10%-30%,20%-40%,30%-50%,40%-60%,50%-70%,60%-80% 
four dots:RH 10%-40%,20%-50%,30%-60%,40%-70%,50%-80%
]]></description><pubDate><![CDATA[20180315]]></pubDate></item>

</channel>
</rss>