<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 5 light sources]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/5_light_sources--2717/1/5 light sources.html]]></link><item>
<title><![CDATA[Mercury Lamp Light Source System CEL-M500-T5]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Mercury_Lamp_Light_Source_System--11446895_11446897.html]]></link><description><![CDATA[CEL-M500-T5 mercury lamp light source is a research grade mercury lamp light source specially for catalytic experiments, photolithography, photocatalysis, photodegradation and chemical synthesis in t]]></description><pubDate><![CDATA[20221027]]></pubDate></item>
<item>
<title><![CDATA[UTOCO Handheld Laser Detector with Tdlas for Natural Gas Distribution Pipeline]]></title><link><![CDATA[https://utoco.en.ec21.com/UTOCO_Handheld_Laser_Detector_with--12010082_12010092.html]]></link><description><![CDATA[sources, enhancing work efficiency and reducing labor demands.
The TDLAS sensor offers high sensitivity, rapid response, and exceptional selectivity, responding exclusively to methane and minimizing ]]></description><pubDate><![CDATA[20240926]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-4 UL94 Horizontal and Vertical Flame Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_4_UL94_Horizontal--11940578_11941787.html]]></link><description><![CDATA[5-11-4, IEC60695-11-3, IEC60950, IEC707, IEC60695-2-2, ISO1210 and etc.. The flammability test uses a bunsen burner of a specified size and specified gas source (methane or natural gas) to ignite the]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[source functions and fill out the procedure template. The 750 Series does the rest. It quickly performs the test, calculates the errors, and displays the final results, highlighting out of tolerance ]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Bruker Tracer 5i Handheld XRF Spectrometer]]></title><link><![CDATA[https://thexrfstore.en.ec21.com/Bruker_Tracer_5i_Handheld_XRF--11822199_11822200.html]]></link><description><![CDATA[50,000 cps Mn Kα; resolution for optimum light element analysis.Analysis range: Detects from Na to U; analyzes from Mg - USize: 27.3 cm x 9.4 cm x 29.5 cm (10.75 in x 3.7 in x 11.6 in) L x W x HWeig]]></description><pubDate><![CDATA[20230720]]></pubDate></item>
<item>
<title><![CDATA[Articulation Flexible Video  Borescope]]></title><link><![CDATA[https://teximinternational.en.ec21.com/Articulation_Flexible_Video_Borescope--6335069_6438294.html]]></link><description><![CDATA[56 drgree
Resolution types
320(H) x 240(V)
Focus distance
SF 1.5~5cm
Light source
4 Bright LED light
Articulation
360&amp;deg;
Operating Temperature
-25&amp;ordm; to 60&amp;ordm; C (-13&amp;ordm; to 140&amp;ordm; F)
Wat]]></description><pubDate><![CDATA[20160901]]></pubDate></item>
<item>
<title><![CDATA[AS-2011 Micron Laser Particle Size Analyzer 0.1-500um]]></title><link><![CDATA[https://aimsizer.en.ec21.com/AS_2011_Micron_Laser_Particle--4628668_4628669.html]]></link><description><![CDATA[500&amp;mu;m
Accuracy:&lt;1%
Repeatability:&lt;1%
Test method:Liquid
Light source:Semiconductor laser (635nm, 3mw, 25000hrs)
Scanning speed: 2000/sec
Test time:&lt; 1 minute, sample preparation not counted
Power ]]></description><pubDate><![CDATA[20100926]]></pubDate></item>
<item>
<title><![CDATA[Automatic Kinematic Viscometer]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Automatic_Kinematic_Viscometer--11718430_11856620.html]]></link><description><![CDATA[56 ASTM D445
2.Viscosity measurement range: 0.5~3000 (replace the viscosity tube according to the degree range)
3.Temperature control range: 20~150°C, (20C requires an external cold source. 
Tempera]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[Horizontal and Vertical Flammability Tester UL94 IEC 60695]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Horizontal_and_Vertical_Flammability_Tester--5441143_9767620.html]]></link><description><![CDATA[5V, HF-1 HF-2, HBF material. 
3.It is also suitable for Lighting equipment, low-voltage electrical appliances, 
household appliances, machine tool electrical appliances, motor, electric tools, 
elect]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[High Precision Spectroradiometer Integrating Sphere System]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/High_Precision_Spectroradiometer_Integrating_Sphere--11882688_11882693.html]]></link><description><![CDATA[5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Ponovo T1000 Primary Injection Test Set for Different Types of Relays]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_T1000_Primary_Injection_Test--11744128_11737778.html]]></link><description><![CDATA[source can be used to test all kinds of current relays, including high burden relay and CT. The AC/DC current and/or voltage sources allow phase angle and frequency to be adjusted smoothly. This make]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Refractometer RA-620 / RA-600]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Refractometer_RA_620_RA_600--8755029_8755113.html]]></link><description><![CDATA[Light Source
LED Na-D Line (589.3nm)
Measuring Items
Refractive Index, Brix, Other Concentrations
Measuring Range
Refractive Index (nD)
1.32000 - 1.58000
1.3200 - 1.7000
Brix
0.00 ~ 100.00%
Accuracy ]]></description><pubDate><![CDATA[20140212]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Window Tint Meter WTM-1100 Light Transmission Meter]]></title><link><![CDATA[https://105landtek.en.ec21.com/Hot_Sale_Window_Tint_Meter--11797706_11797708.html]]></link><description><![CDATA[Light Source:LED
Measuring Mode:Single / Continuous
Operating conditions:Temperature: 0 ~ 50 ℃ Humidity: &lt; 90 %
Power Supply:4 x 1.5 V AAA Size (UM-4) Battery
Dimensions:Unit: 126 x 65 x 27 mm (5.0]]></description><pubDate><![CDATA[20231125]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[5x
total magnification
30-225 times
Object field of view
7-1.1MM
light source
Surface light and outline light: white LED, brightness continuously adjustable
Power Supply
220 V ± 10%, 50 Hz electrica]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[UV Light Chamber Supplier UV Chamber Plastic Aging Test Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/UV_Light_Chamber_Supplier_UV--11825687_11825701.html]]></link><description><![CDATA[Light Chamber Supplier UV Chamber Plastic Aging Test Chamber is applicable for the sunlight resistant test of nonmetallic materials and aging test of artificial light sources. A variety of industrial]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Sobek Metallographic Tool-Makers Microscope]]></title><link><![CDATA[https://sobek.en.ec21.com/Sobek_Metallographic_Tool_Makers_Microscope--10029761_10670633.html]]></link><description><![CDATA[50 line color camera
Software
SBK-MM
Work-table loading
35KG
Illuminating system
Cold light source transmission lighting, 10W LED reflection lighting
Nosepiece
Five-hole objective rotary table (with ]]></description><pubDate><![CDATA[20180228]]></pubDate></item>
<item>
<title><![CDATA[LM-79 Moving Detector Goniophotometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/LM_79_Moving_Detector_Goniophotometer--11802221_11802222.html]]></link><description><![CDATA[light. The measuring distance is from 5m to 30m.
What is the use of goniophotometer?LSG-6000 gonio photometer manufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting ]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[light alarm when output has short.
Over load protection: Auto-tripping when power supply or load has fault and output current exceeds 1.5 times of rated value.
Current-limit protection: User set curr]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Characteristics of Water Quality COD Measuring Instrument]]></title><link><![CDATA[https://kobebean24.en.ec21.com/Characteristics_of_Water_Quality_COD--11076331_11855969.html]]></link><description><![CDATA[light source is longer with imported tungsten lamps;10. Curve correction, supporting automatic curve correction and automatic saving;11. Memory curve, 5 manufacturer curves, 195 extension curves, a t]]></description><pubDate><![CDATA[20231018]]></pubDate></item>
<item>
<title><![CDATA[Aozeesolar Mini EL Detector for Solar Stringer Testing with Ai System]]></title><link><![CDATA[https://aozeesolar2023.en.ec21.com/Aozeesolar_Mini_EL_Detector_for--11834813_11834818.html]]></link><description><![CDATA[light test High current test6-10A High current hidden crack defect testLow current test0.1-5A weak current attenuation test (capableof 0.1A detection imaging)Configuration List:1EL camera2400-5G1(Pix]]></description><pubDate><![CDATA[20231128]]></pubDate></item>
<item>
<title><![CDATA[CO/CO2/SO2/NO Analyzer]]></title><link><![CDATA[https://xajunengins.en.ec21.com/CO_CO2_SO2_NO_Analyzer--10893051_11403132.html]]></link><description><![CDATA[source emission, etc.
2. Industrial control of petroleum &amp; chemical, etc.
3. Agriculture, medical health &amp; scientific research, etc.
4. Test gas density of kinds of combustion test in lab
5. Monitor ]]></description><pubDate><![CDATA[20210621]]></pubDate></item>
<item>
<title><![CDATA[EMI Receiver System]]></title><link><![CDATA[https://15317383997.en.ec21.com/EMI_Receiver_System--11812738_11812765.html]]></link><description><![CDATA[5A), 3pcs Isolation Transformers, Attenuator and cables.
Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers:• LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Source]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[CST-50 Impact Specimen U/V Notch Projector]]></title><link><![CDATA[https://wanchen123.en.ec21.com/CST_50_Impact_Specimen_U--11774583_11774608.html]]></link><description><![CDATA[table rotary range: 0°-360°
Amplification rate: 50*
Objective lens: 2.5* 
rojecting objective lens: 20*
Light source: DC12V 100W
Dimension : 510*220*600
Weight: 18KG
Power 
supply: 220V 50Hz 150W
]]></description><pubDate><![CDATA[20230529]]></pubDate></item>
<item>
<title><![CDATA[Anti-yellowing Aging Test Chamber]]></title><link><![CDATA[https://annie0423.en.ec21.com/Anti_yellowing_Aging_Test_Chamber--9938796_9938808.html]]></link><description><![CDATA[Light Sources &amp;ndash; Part 1: General guidance
(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps
(5) ASTM D4329: Standard Practice for Fluoresc]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>