<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - 5 settings]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/5_settings--2717/1/5 settings.html]]></link><item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[5000V adjustable, to meet the detection of peak voltage conditions of charged equipment;
★LCD screen: 3.5 inch LCD touch screen, 12-point viewing angle, easy for watching;
★Alarm mode: sound, lig]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_TI480_PRO_Thermal_Imaging--12045274_12045346.html]]></link><description><![CDATA[settings and usage)Battery charge time: 2.5 hours to full chargeBattery charging system: Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapterAC operation: AC opera]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[5 cm (approx. 6 in)IR-Fusion® technologyFull screen Level and spanSmooth auto and manual scalingTouchscreen adjustable level/spanYes. Span and level can be easily and quickly set by simply touching ]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[Secure Seal Tester]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Secure_Seal_Tester--12024209_12034886.html]]></link><description><![CDATA[tank.Accurate flow control, adjustable rising speed. Adjustment range: the time to pressurize to 1Mpa can be adjusted to any time in the range of 5-60 seconds.High sensitivity and high accuracy.]]></description><pubDate><![CDATA[20250106]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[settings and usage)Battery charge time2.5 hours to full chargeBattery charging systemTwo-bay battery charger or in-imager charging. Optional 12 V automotive charging adapterAC operationAC operation w]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[YH800C Portable Fully Automatic Pressure Calibrator]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800C_Portable_Fully_Automatic_Pressure--12022422_12033066.html]]></link><description><![CDATA[5. Instrument interface: Provides multiple standard interfaces with strong compatibility, capable of connecting various types of pressure instruments, including pointer instruments, pressure transmit]]></description><pubDate><![CDATA[20241225]]></pubDate></item>
<item>
<title><![CDATA[Construction Laser Level]]></title><link><![CDATA[https://holo1.en.ec21.com/Construction_Laser_Level--11967590_11967628.html]]></link><description><![CDATA[5s
Horizontal line and vertical lines can be switched automatically
360°rotating,outdoor and indoor use
Can be used with tripod to adjust the level height
Essential Components: Understanding the Ana]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[Exit Device Durability Test Equipment]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Exit_Device_Durability_Test_Equipment--11987076_11989323.html]]></link><description><![CDATA[set of wooden block for
surface mounting. One set of adjustable tube for concealed door closer
mounting.
e) 
Equipment size：L1.2m
x W0.8m x H2.5m ；
f) 
Operation space：1.2
m x 1.6 m x 2.5m；
g]]></description><pubDate><![CDATA[20241122]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[ModelStudio Size (D*W*H)mmDimension（D*W*H）mmLRHS-101B-3LJ450×450×500Subject to contractual three-viewLRHS-225B-3LJ500×600×750temperature rangeA:-20℃～150℃ B:-40℃～150℃C:-60℃～150]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[Dissolved Ozone Meter Intelligent Online Water Ozone Analyzer Tester Sanitizer Ozone]]></title><link><![CDATA[https://nobotech.en.ec21.com/Dissolved_Ozone_Meter_Intelligent_Online--11181496_11182362.html]]></link><description><![CDATA[set freely. Relay load :3A 220VAC/24VDC.◇Working conditionsenvironmental temperature of 0~60℃, relative humidity ≤90%◇Output load:&lt;750Ω(4-20mA)◇Working voltage: 220VAC10%,50/60Hz.◇Dimens]]></description><pubDate><![CDATA[20240929]]></pubDate></item>
<item>
<title><![CDATA[Emcee Model 1140 Micro-Separometer]]></title><link><![CDATA[https://xmjielian.en.ec21.com/Emcee_Model_1140_Micro_Separometer--11982130_11982132.html]]></link><description><![CDATA[5th edition API certified media. A portion of the sample, in a clear glass vial, is used to set the meter to read 100. The sample in the vial is discarded and the vial is retained.Another portion of ]]></description><pubDate><![CDATA[20240808]]></pubDate></item>
<item>
<title><![CDATA[Steel Bar/Steel Tube/Steel Pipe/Rebar Bending Testing Machine]]></title><link><![CDATA[https://lgtester4.en.ec21.com/Steel_Bar_Steel_Tube_Steel--9978752_10041383.html]]></link><description><![CDATA[50mm
Positive angle of the plate bending
0°-180° with the arbitrary set
Reverse angle of the plate bending
0°-25° with the arbitrary set
Working disk rotated speed
≤ 3.7 r/min
Distance of 219 m]]></description><pubDate><![CDATA[20240803]]></pubDate></item>
<item>
<title><![CDATA[Surface Roughness Gauge]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Surface_Roughness_Gauge--11973711_11973717.html]]></link><description><![CDATA[settings and display, convenient data recording and storage 
● Low power consumption design.
● Reliable circuit and software design can avoid system halted.
● Measurement display, menu prompt i]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[NDJ-8T Lab Digital Rotating Viscosity Meter Viscosimeter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_8T_Lab_Digital_Rotating--11144324_11144457.html]]></link><description><![CDATA[5T
NDJ-5T
Control / display mode
5-inch color touch screen
Speed (r/min)
6/12/30/60
0.3/0.6/1.5/3/6/12/30/60
Measuring range 
1~100000mPa.s
1~2000000mPa.s
(1-10mPa.s, need to choose 0# rotor)
Rotor
1]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Hot Rolled Bar Outer Diameter Measuring Instrument GDC-J2400-JX]]></title><link><![CDATA[https://measurementon.en.ec21.com/Hot_Rolled_Bar_Outer_Diameter--11962128_11962129.html]]></link><description><![CDATA[set of equipment comes standard: control cabinet, measuring vehicle, electrical control box, LED display, cooling and dust removal system and supporting facilities.
Adaptable rolling speed: ≤120m/s]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[Xenon Lamp Weather Resistance Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Xenon_Lamp_Weather_Resistance_Test--11164019_11167773.html]]></link><description><![CDATA[550*450 mm
950*950*900 mm
External dimensions (D*W*H)
1400*750*1500 mm
1840*1150*1900 mm
Performance 
Temperature range
-70...+80℃
Humidity range
40...95%RH
Temperature uniformity
±2℃
Temperatur]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Sand and Dust Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Sand_and_Dust_Test_Chamber--11853101_11854273.html]]></link><description><![CDATA[blowing dust time can be set, cycle period can be
adjusted, time can be adjusted.
Safety device
Over-temperature
protection, grounding protection, etc.
Power supply
AC 220V/380V±10%,
50 Hz±0.5Hz
]]></description><pubDate><![CDATA[20240619]]></pubDate></item>
<item>
<title><![CDATA[ST-6608 Static Force Test Machine]]></title><link><![CDATA[https://satatec.en.ec21.com/ST_6608_Static_Force_Test--7687564_7687808.html]]></link><description><![CDATA[5Lb, 8Lb &amp; 10Lb, each 6pcs and portfolio stackable the weight suitable difference specimen for testing;
Support tray travel: ≤300mm;
Timer: 0.1-999.9S continually timing and setting ,when up to set]]></description><pubDate><![CDATA[20240614]]></pubDate></item>
<item>
<title><![CDATA[F105/F305/F505/F505H Advanced Test Stand Frame]]></title><link><![CDATA[https://lanetech11.en.ec21.com/F105_F305_F505_F505H_Advanced--11944805_11944810.html]]></link><description><![CDATA[set the test limits or testing exception. Dual-graduated rulers’ aid with switch placement.
4. Perfect force sensor interface
Series FS05 force sensors mount the crosshead of model F105, F305, F505]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[RLK605 Infrared Radiation Power Meter]]></title><link><![CDATA[https://gatherstar.en.ec21.com/RLK605_Infrared_Radiation_Power_Meter--11943208_11943437.html]]></link><description><![CDATA[5 ~ 1 m
Aiming method 
Laser dot aiming
Display 
1.54 inches, OLED, monochrome
Display information 
Radiated power/working distance/signal voltage
Parameter settings 
Working distance/calibration coe]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator with 15KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_5_Lightning_Surge--11944039_11944066.html]]></link><description><![CDATA[500
Ω±10％
Trigger mode
Synchronization, 
asynchronization
Inject phase
Freely set at 0－360°，resolution:1°
Trigger mode
Auto or manual, single
Surge times
1-9999 times
Memories
1000 groups, ]]></description><pubDate><![CDATA[20240528]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[Remote Overhead Line Fault passage indicator for power distribution network 
SUMMARY
SNV308.1 series overhead type Fault Indicator system is based on the Sensor that through CT get the (6KV-50KV) lin]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Wire Harnesses/Cables Testing Bench Top(Table) for Automotive]]></title><link><![CDATA[https://shcleanknow4567.en.ec21.com/High_Voltage_Wire_Harnesses_Cables--11923899_11923921.html]]></link><description><![CDATA[5. 
Synchronous recording of test data helps customers promptly understand product quality;
6. 
Printer function, freely to edit printing content;
7. Bar code scanning automatically loads test file a]]></description><pubDate><![CDATA[20240412]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[54 supports the commands contained in HART protocol Version 5.7. With 2 MB of memory, the 754 supports a substantial set of HART instructions:
Universal commands provide functions that are implemente]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD20 Factory Direct Sell Bump Test Machine for Mechanical Impact Testing]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD20_Factory_Direct_Sell_Bump--11098426_11099399.html]]></link><description><![CDATA[set arbitrarily, and it will stop automatically after the test
is completed
Technical Specifications
Model
Parameters
KRD
20－50
KRD
20－100
KRD
20－200
KRD
20－500
KRD
20－800
KRD
20－1000
KRD]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Vacuum Leak Tester for Packaging Plastic Bag Heat Seal Strength Leakage Tester ASTM D3078 Tester]]></title><link><![CDATA[https://celtec.en.ec21.com/Vacuum_Leak_Tester_for_Packaging--9267516_9168922.html]]></link><description><![CDATA[set vacuum level is attained. Should even a minor leak be present, the ensuing pressure differential forces trapped air out, manifesting as observable bubbles from the leakage point.
Technical Specif]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[TTR-I Fully Automatic Three Phase Power Transformer Turns Ratio Test Set]]></title><link><![CDATA[https://cndeltatech.en.ec21.com/TTR_I_Fully_Automatic_Three--11542988_11543002.html]]></link><description><![CDATA[TTR-I Fully Automatic Three Phase Power Transformer Turns Ratio Test Set
Introduction:
TTR-I Transformer Turns Ratio Tester is designed according IEC76-1 and IEC60044. It can be applied to test the t]]></description><pubDate><![CDATA[20220314]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[5Hz
Category
Core components
Brand
Quantity
Main part
Base and column
Shandong Taiqing marble component
1 set
Mobile workbench
Upper, middle and lower three layers of high-precision iron castings
1 s]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Programmable Hast Accelerated Aging Tester for Industry]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Programmable_Hast_Accelerated_Aging_Tester--11825687_11825700.html]]></link><description><![CDATA[50350×450450×550550×650650×750External Dimension Φ×D (mm)850×1300×900900×1350×9001000×1480×10001150×1650×12001300×1800×1350Steam Temperature Range Steam Temperature Range: 100ºC~135]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Temperature Humidity Standard Environment Experiment Calibration Chamber Cabinet]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Temperature_Humidity_Standard_Environment_Experiment--11689458_11689464.html]]></link><description><![CDATA[5 minutes
* Fan speed regulation: inner cavity main circulation fan, using frequency conversion speed regulation control, through touch screen, set fan speed;
* Multiple protection alarms: constant t]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Leak Tester]]></title><link><![CDATA[https://celtec3.en.ec21.com/Leak_Tester--11861428_11861429.html]]></link><description><![CDATA[set vacuum. If a minor leak exists, the pressure difference expels trapped air, evidenced by bubbles emerging from the leak area.
Main Parameters 
Test Range 0~-90 KPa
Chamber Acrylic Cylinder Shape
]]></description><pubDate><![CDATA[20231101]]></pubDate></item>
<item>
<title><![CDATA[Automatic Capacitance and Dissipation Factor Test Set]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Automatic_Capacitance_and_Dissipation_Factor--11895397_11895406.html]]></link><description><![CDATA[Automatic capacitance and dissipation factor test set
Product Description
Hengfeng tan delta tester
measures the capacitance and dissipation factor factor (tgδ) of high voltage electric equipment.
1]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/3kW_3.5kW_4kW_5kW_6kW--11807084_11807114.html]]></link><description><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test
3-12kw AC220/240V Rack Mounted Load Bank for Data Center TestMAIN FUNCTION AND FEATURES 1: Perfect simulation of server power usage]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Intelligent Temperature Measuring Machine]]></title><link><![CDATA[https://auroraguoxia12.en.ec21.com/Intelligent_Temperature_Measuring_Machine--11599950_11770469.html]]></link><description><![CDATA[5-1 meters;
RGB three-color fill light real-time feedback recognition results, night infrared, RGB dual fill light;
Support serial port, Wiegand 26, 34 output and input, and output content supports c]]></description><pubDate><![CDATA[20230417]]></pubDate></item>
<item>
<title><![CDATA[Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/Olympus_Nortec_600D_Eddy_Current--11834264_11834281.html]]></link><description><![CDATA[5.7 inch (14,5 cm) VGA display.Full-screen option in any display mode.Improved filters for rotary scanner mode.Intuitive interface with Application Selection presets.All-settings configuration page.1]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[MDKM Gas Meter Leakage Test Bench]]></title><link><![CDATA[https://royreal.en.ec21.com/MDKM_Gas_Meter_Leakage_Test--11907986_11909878.html]]></link><description><![CDATA[Product Introduction
The equipment is subject to the regulations of JJG577-2012 diaphragm gas meter and JJF 1354-2012 diaphragm gas meter type evaluation outline, and is used to verify the tightness ]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[F316 Smart Battery Calibration]]></title><link><![CDATA[https://szdianliang.en.ec21.com/F316_Smart_Battery_Calibration--11842634_11842640.html]]></link><description><![CDATA[set various configuration parameters, and it is difficult to increase subsequent models;
F316 Smart Battery Calibration came into being:
1. Solve the problem that only 1-2 batteries can be calibrated]]></description><pubDate><![CDATA[20230908]]></pubDate></item>
<item>
<title><![CDATA[China MIL-STD-810H Military Standard Dual Blowing Dust Sand Proof Resistance Test Chamber Machine]]></title><link><![CDATA[https://enviclonetestchamber.en.ec21.com/China_MIL_STD_810H_Military--11887764_11887766.html]]></link><description><![CDATA[Overview
Dual Blowing Dust and Sand Chamber is designed as per MIL-STD-810G now MIL-STD-810H 510.5 test standard. It is to test the dust proof performance of enclosures of products.
Engineering Team ]]></description><pubDate><![CDATA[20240114]]></pubDate></item>
<item>
<title><![CDATA[ESS Chambers-Rapid Temperature Change Test Chamber]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/ESS_Chambers_Rapid_Temperature_Change--11847973_11848017.html]]></link><description><![CDATA[5°C to 200°C in a single stage or -73°C to 200°C in a cascade. The fast rate change chamber uses scroll compressor technology to provide quiet operation, fast conversion rates and reliable operat]]></description><pubDate><![CDATA[20231107]]></pubDate></item>
<item>
<title><![CDATA[EHS Shore Durometer Hardness Tester Unit]]></title><link><![CDATA[https://mikrometry.en.ec21.com/EHS_Shore_Durometer_Hardness_Tester--11911431_11911440.html]]></link><description><![CDATA[5．Data Printing
The test report can be print using EPX-58P wireless printer. You can set the Auto Print to ON, or print the historical data in memory by Print All and Print Select. The print items ]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[GBPI Automatic Oxygen Transmission Rate Tester Y310 2.0]]></title><link><![CDATA[https://gbpitester.en.ec21.com/GBPI_Automatic_Oxygen_Transmission_Rate--11629254_11631112.html]]></link><description><![CDATA[Products DescriptionY310 2.0 Oxygen Permeability AnalyzerApplicationOxygen Permeability Analyzer is to test the oxygen transmission rate (OTR) of films or sheets materials.
Standard ASTM D3985， AST]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Automatic Kinematic Viscometer]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Automatic_Kinematic_Viscometer--11718430_11856620.html]]></link><description><![CDATA[56 ASTM D445
2.Viscosity measurement range: 0.5~3000 (replace the viscosity tube according to the degree range)
3.Temperature control range: 20~150°C, (20C requires an external cold source. 
Tempera]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[New Olympus BondMaster 600 Multimode Bond Tester]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_BondMaster_600_Multimode--11801594_11801602.html]]></link><description><![CDATA[Settings configuration page screen.Up to two real-time readings.Storage capacity of up to 500 files (program and data).On-board file preview.Two Models for Flexibility and CompatibilityThe BondMaster]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Automatic Safety Test System]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Automatic_Safety_Test_System--11882688_11882704.html]]></link><description><![CDATA[set. It has alarm sound and indicator light• Test mode is programmable; 50 groups settings are available, 8 test steps per group• Quick discharge. Support 50Hz and 60Hz frequency; Electric safety]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[18650/32650/21700 Battery TESTER 1-24s 32 Series Bms PCB Testing Machine High Accuracy Bms Tester]]></title><link><![CDATA[https://aitop2018.en.ec21.com/18650_32650_21700_Battery_TESTER--11585406_11585409.html]]></link><description><![CDATA[24 Series Bms Testing System Lithium Battery Pack Bms Pcb Tester 18650 Lithium Battery Tester 
Machine feature : 
The PBTS series multi-function BMS board testing machine is mainly used to testing th]]></description><pubDate><![CDATA[20231007]]></pubDate></item>
<item>
<title><![CDATA[Liquid Chromatograph]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Liquid_Chromatograph--11907876_11909750.html]]></link><description><![CDATA[5%
Flow stability error ≤ 0.2% RSD
The pressure fluctuation is less than 15Psi (flow rate of 1mL/min, pressure of 600-1600Psi)
The sealing pressure of the pump is 5400 Psi, with a time of 10 minute]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[Dustproof Testing Machine | Dust Proof Chamber]]></title><link><![CDATA[https://15317383997.en.ec21.com/Dustproof_Testing_Machine_Dust_Proof--11812738_11858081.html]]></link><description><![CDATA[SC-015 Dust-proof Test Chamber (Sand Dust Chamber) is applied to physical and other related performance tests for electronic and electrical products, lamps, electrical cabinets, electrical components]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Automatic Melting Point Tester]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Automatic_Melting_Point_Tester--11600339_11776721.html]]></link><description><![CDATA[5: Compatible with measuring powder and paste samples;
6: Equipped with high-definition camera lens module.
2. Automatic Melting Point Apparatus Parameter
Model:
JH70D
Product name:
Automatic Melting]]></description><pubDate><![CDATA[20230426]]></pubDate></item>
<item>
<title><![CDATA[Eyc DPM02 Multifunction Signal Display Monitor]]></title><link><![CDATA[https://84218930eyctech.en.ec21.com/Eyc_DPM02_Multifunction_Signal_Display--11424436_11424441.html]]></link><description><![CDATA[Features
Measuring input type : DC current / DC voltage
More output type:Analog output / Relay / RS-485
Extraction of square root(Input : voltage, current)
Option RS-485 communication function can do]]></description><pubDate><![CDATA[20220513]]></pubDate></item>
<item>
<title><![CDATA[Multi-function Optical Fiber Light Source CEL-FES300 Photocatalysis]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Multi_function_Optical_Fiber_Light--11446837_11446865.html]]></link><description><![CDATA[500 mW/cm²; □40mm，&lt;200 mW/cm²; □60mm，&lt;100 mW/cm²）Electronic shutterThe precision is 0.01s, the opening and closing time and the number of cycles can be set arbitrarily.Output power in ul]]></description><pubDate><![CDATA[20221027]]></pubDate></item>

</channel>
</rss>