<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - Backing System]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/Backing_System--2717/1/Backing System.html]]></link><item>
<title><![CDATA[Custom Optical Grating Replication Service | OEM Grating for Spectrophotometers]]></title><link><![CDATA[https://meticulab.en.ec21.com/Custom_Optical_Grating_Replication_Service--12069839_12069840.html]]></link><description><![CDATA[Systems &amp; Telecommunication Equipment
Replacement parts for old or obsolete analytical instruments
⚙️ Working Process
Submit Your Requirement: Send master grating, technical drawing or optical sp]]></description><pubDate><![CDATA[20260420]]></pubDate></item>
<item>
<title><![CDATA[Thermal Shock Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Thermal_Shock_Test_Chamber--11164019_11164171.html]]></link><description><![CDATA[system 
Refrigeration mode
Mechanical compression, two-stage refrigeration
Cooling mode
Water cooling
Compressor 
Imported compressor
Temperature sensor
Pt100
Controller 
Programmable logic controlle]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[ISO16750-4 Clause 5.4.2 Ice Water Splash Test Chamber for Automotive Parts]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/ISO16750_4_Clause_5.4.2_Ice--11940576_11941038.html]]></link><description><![CDATA[system or components when driving on wet roads
in
the winter. Failure modes are mechanical cracking of materials or seal failures caused by different temperature expansion coefficients. It’s a reli]]></description><pubDate><![CDATA[20240522]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[Remote Overhead Line Fault passage indicator for power distribution network 
SUMMARY
SNV308.1 series overhead type Fault Indicator system is based on the Sensor that through CT get the (6KV-50KV) lin]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[ICONE2]]></title><link><![CDATA[https://kobistq.en.ec21.com/ICONE2--1_11135288.html]]></link><description><![CDATA[systems. Oxygen depletion calorimetry was identified as the best measurment method. This is based on the empirical observation that heat released by burning materials is directly proportional to the ]]></description><pubDate><![CDATA[20200511]]></pubDate></item>
<item>
<title><![CDATA[SAW Pipe Real-time Inspection System]]></title><link><![CDATA[https://ndtchina.en.ec21.com/SAW_Pipe_Real_time_Inspection--6581053_6161342.html]]></link><description><![CDATA[System configuration
1. X-ray machine
2. Image intensifier: Supported by holder which can move up and down, ahead and back as well as rotate 45&amp;deg;circum horizontal axis to adjust the image position]]></description><pubDate><![CDATA[20140520]]></pubDate></item>
<item>
<title><![CDATA[Box Compression Tester for Carton Box]]></title><link><![CDATA[https://celtec.en.ec21.com/Box_Compression_Tester_for_Carton--9267550_9524596.html]]></link><description><![CDATA[system
Technical Data
Pressure range: 0-10KN
Force resolution: 0.1N，Display error: ±2%
Display variation: ≤2%，Back to zero error: ±0.2%FS
Deformation measurement accuracy: ±1mm
Compressing s]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[Hybrid Karl Fischer Moisture Titrator MKH-700]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Hybrid_Karl_Fischer_Moisture_Titrator--8755027_8755067.html]]></link><description><![CDATA[System&quot; which does not require pure water for factor determination. 
Karl Fischer Moisture Titrator which is on the market is necessary to adjust the sample amount when carrying out the measurement. ]]></description><pubDate><![CDATA[20140212]]></pubDate></item>
<item>
<title><![CDATA[Electrodynamic Vibration Generator System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Electrodynamic_Vibration_Generator_System--9657760_11802794.html]]></link><description><![CDATA[System – After Sales Questions and Answers.LISUN LVD-100KG Electrodynamic Vibration Generator System were in the market for more than 10 years, LISUN engineers service team already summary the most]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Netlite Handheld Ethernet Tester]]></title><link><![CDATA[https://xinertel.en.ec21.com/Netlite_Handheld_Ethernet_Tester--10761704_10761757.html]]></link><description><![CDATA[System control
One on/off button，one reset button for configuration reset
AC adapt
input：100-240VAC, 50-60HZ
output：5V, 2A
Battery
5 hours
temperature
-10~45℃
humidity
5%~95%，Non condensati]]></description><pubDate><![CDATA[20190419]]></pubDate></item>
<item>
<title><![CDATA[Nuclear Radiation Detector Geiger Counter]]></title><link><![CDATA[https://trader59.en.ec21.com/Nuclear_Radiation_Detector_Geiger_Counter--11743524_11743529.html]]></link><description><![CDATA[back. Adjustable system languages English, German. Dimensions: 115x58x25mm. Weight: 130g (with batteries).
Applications
This product can be widely used in home radiation testing, radiation processing]]></description><pubDate><![CDATA[20230308]]></pubDate></item>
<item>
<title><![CDATA[Film Free Shrink Tester Shrinkable Film Testing Machine Plastic Film]]></title><link><![CDATA[https://systester18.en.ec21.com/Film_Free_Shrink_Tester_Shrinkable--10847135_10892263.html]]></link><description><![CDATA[back-sheets in the fluid medium at different temperatures.
Film Free Shrink Tester Shrinkable Film Testing Machine Plastic Film 
Features:
l Embedded system controls
l Touch screen operation
l TFT re]]></description><pubDate><![CDATA[20221214]]></pubDate></item>
<item>
<title><![CDATA[ESS, EV Battery Quality Analyzer]]></title><link><![CDATA[https://tekon1.en.ec21.com/ESS_EV_Battery_Quality_Analyzer--11010564_11156929.html]]></link><description><![CDATA[To prevent faults or quality issues in critical battery back-up applications caused by defects in stationary batteries, TEKON970 ESS(Energy Storage System) Battery Quality Analyzer enables the user t]]></description><pubDate><![CDATA[20201231]]></pubDate></item>
<item>
<title><![CDATA[Horizontal Type Valve Pressure Test Bench]]></title><link><![CDATA[https://valvegrindingmachine.en.ec21.com/Horizontal_Type_Valve_Pressure_Test--10886107_10886118.html]]></link><description><![CDATA[systems,gas supercharging is selection
3. Technical parameters:
Valve Nominal Diameter DN
300-800mm(straight-through Flange connection valves)
Maximium Test Pressure PN
31.5Mpa(4500LB) Max
Nominal Vo]]></description><pubDate><![CDATA[20220509]]></pubDate></item>
<item>
<title><![CDATA[ANDOR DV435-BV Series CCD Camera W/Software]]></title><link><![CDATA[https://gridatama123.en.ec21.com/ANDOR_DV435_BV_Series_CCD--11812295_11812303.html]]></link><description><![CDATA[system also benefits from negligible dark current with thermoelectric cooling down to –70°C.Features &amp; Benefits of the DV435 Series• Peak QE of 95%: High detector sensitivity• 
Min operating t]]></description><pubDate><![CDATA[20230627]]></pubDate></item>
<item>
<title><![CDATA[Solar Simulator Xenon Lamp Light Source Solar Cell IV Test]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Solar_Simulator_Xenon_Lamp_Light--11446867_11446868.html]]></link><description><![CDATA[system safety; power-off delay function, increasing the service life of the lamp; light source can be installed inside the 150W, 350W, 500W high-pressure short-arc spherical xenon lamp, the formation]]></description><pubDate><![CDATA[20240104]]></pubDate></item>
<item>
<title><![CDATA[Computer Control YFT-300 Claws Clamping Type Hydraulic Valve Test Bench for Test Flange End Valves]]></title><link><![CDATA[https://king3834656.en.ec21.com/Computer_Control_YFT_300_Claws--11745449_11745450.html]]></link><description><![CDATA[system.When using it，the high pressure condition and the relief pressure condition can be changed by itself. So it can reduce oil temperature, elongate the life of valve test bench. 8. PLC control ]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Omniscan MX2 PA Flaw Detector]]></title><link><![CDATA[https://tol22man.en.ec21.com/Used_Olympus_Omniscan_MX2_PA--11836190_11836198.html]]></link><description><![CDATA[system. Olympus offers a complete product range that includes phased array probes, scanners, analysis software, and accessories, all of which are integrated and packaged into rapidly deployable, appl]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[WQLB Sonic Nozzle Gas Flow Standard Facility]]></title><link><![CDATA[https://royreal.en.ec21.com/WQLB_Sonic_Nozzle_Gas_Flow--11907986_11909431.html]]></link><description><![CDATA[back pressure container, a buffer container, a flow meter quick switching mechanism, and a bus measurement and control system.
Product Features
1. Sonic nozzle multi-filter, clean without clogging.2.]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[Gas Chromatography]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Gas_Chromatography--11907876_11907884.html]]></link><description><![CDATA[system ensures the reliable operation of the instrument.
The synchronous external triggering function can be triggered by external signals (such as automatic samplers, thermal analyzers, etc.) to sim]]></description><pubDate><![CDATA[20240301]]></pubDate></item>
<item>
<title><![CDATA[High Precision Spectroradiometer Integrating Sphere System]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Precision_Spectroradiometer_Integrating_Sphere--11812738_11812754.html]]></link><description><![CDATA[System Brochure
Specification:• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Samp]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Eagle Eye Power Solutions IPQMS-C320]]></title><link><![CDATA[https://geomultimeter1.en.ec21.com/Eagle_Eye_Power_Solutions_IPQMS--11866765_11866787.html]]></link><description><![CDATA[back-up batteries.Adopting the world’s first ripple-removing algorithm, USA patent: US 7,567,085B2, the system precisely measures battery health while the system is on-lineWith flexible expanding s]]></description><pubDate><![CDATA[20231115]]></pubDate></item>
<item>
<title><![CDATA[High Precision Spectroradiometer Integrating Sphere System]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/High_Precision_Spectroradiometer_Integrating_Sphere--11882688_11882693.html]]></link><description><![CDATA[System Brochure
Specification:• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Samp]]></description><pubDate><![CDATA[20240102]]></pubDate></item>

</channel>
</rss>