<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - Generating Set]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/Generating_Set--2717/1/Generating Set.html]]></link><item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[set by simply touching the screenFast auto toggle between manual and auto modesYesFast auto-rescale in manual modeYesMinimum span (in manual mode)2.0 °C (3.6 °F)Minimum span (in auto mode)3.0 °C (]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[set ‘normal’ temperature ranges quickly with color alarmsMore intuitive visual interface, improved, user-tested, touch screen interfaceTech SpecsThermal Imagers/Building and Industrial Thermal Im]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[WDLYCH/WDLHCN CCS Marine Analog Panel Current Meter/Ammeter for Switchboards]]></title><link><![CDATA[https://jade900920.en.ec21.com/WDLYCH_WDLHCN_CCS_Marine_Analog--11663243_12026218.html]]></link><description><![CDATA[generator set and control engineering. It is high end meter, and suitbale for complicated environment to measure electric/non-electric energy.
Technical parameters:
Product Name
Customized 0-100A Mar]]></description><pubDate><![CDATA[20241227]]></pubDate></item>
<item>
<title><![CDATA[YH800C Portable Fully Automatic Pressure Calibrator]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800C_Portable_Fully_Automatic_Pressure--12022422_12033066.html]]></link><description><![CDATA[general pressure gauges, precision pressure gauges, digital pressure gauges, pressure switches, pressure sensors, pressure transmitters, etc;
◆ Built in 2 pressure modules, can be externally connec]]></description><pubDate><![CDATA[20241225]]></pubDate></item>
<item>
<title><![CDATA[Smoke Alarm Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke_Alarm_Test_Tunnel--11987076_11987077.html]]></link><description><![CDATA[set in the software
Test Items：
Smoke alarm and smoke detector
1． 
Initial
sensitivity
2． 
Directional
dependence
3． 
Air
movement
4． 
Repeatability
5． 
Dry
heat t
6． 
Dazzling
(small s]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Emcee Model 1150 Staticon]]></title><link><![CDATA[https://xmjielian.en.ec21.com/Emcee_Model_1150_Staticon--11982130_11982355.html]]></link><description><![CDATA[set in the Control Module (Fig. 1). The test cell in the Fuel Cell Module generates conductivity and temperature data that is passed through the Barrier Module to the Console Module where it is proce]]></description><pubDate><![CDATA[20240808]]></pubDate></item>
<item>
<title><![CDATA[Fully Automatic Online Surface Defect Detection Equipment BQJ-D4100]]></title><link><![CDATA[https://measurementon.en.ec21.com/Fully_Automatic_Online_Surface_Defect--11962128_11962130.html]]></link><description><![CDATA[set of equipment: image acquisition vehicle, terminal control cabinet, cooling unit, air compressor, and auxiliary facilities;
Adaptable rolling speed: ≤120m/s
Adaptable rolling temperature: ≤120]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator with 15KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_5_Lightning_Surge--11944039_11944066.html]]></link><description><![CDATA[set at 0－360°，resolution:1°
Trigger mode
Auto or manual, single
Surge times
1-9999 times
Memories
1000 groups, built in IEC standard
Surge interval
30-9999s
Built in network capacity
Single pha]]></description><pubDate><![CDATA[20240528]]></pubDate></item>
<item>
<title><![CDATA[Smart Supervisor IIOT Gateway]]></title><link><![CDATA[https://autobitslabspvtltd.en.ec21.com/Smart_Supervisor_IIOT_Gateway--11932545_11932546.html]]></link><description><![CDATA[Edge Computing
: On board data processing based on rules &amp; logic set by you. Minimizes cloud cost.
- High Speed Data Acquisition : High Speed data acquisition of 50ms for demanding applications.
]]></description><pubDate><![CDATA[20240504]]></pubDate></item>
<item>
<title><![CDATA[KRD102 Clamping Force Tester]]></title><link><![CDATA[https://cmetechnology.en.ec21.com/KRD102_Clamping_Force_Tester--11925572_11925593.html]]></link><description><![CDATA[set data signal to the proportional servo amplifier to control the corresponding electro-hydraulic proportional servo valve. The electro-hydraulic proportional servo valve is supplied with pressure f]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[set of HART instructions:
Universal commands provide functions that are implemented in all field devices, for example, read manufacturer and device type, read primary variable (PV), or read current o]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[ICONE2]]></title><link><![CDATA[https://kobistq.en.ec21.com/ICONE2--1_11135288.html]]></link><description><![CDATA[generator fitted with a safety cut-out device. 
Exhaust System - Manufactured from stainless steel for long life. This comprises of a hood, a gas sampling ring probe, an exhaust fan (with adjustable ]]></description><pubDate><![CDATA[20200511]]></pubDate></item>
<item>
<title><![CDATA[JB-300W Microcomputer Controlled Impact Testing Machine]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/JB_300W_Microcomputer_Controlled_Impact--6651349_6678504.html]]></link><description><![CDATA[bob hammer; 
3. on a pair of blocks and other assistive technology device; 
4. a computer, color ink-jet A4 printer ; 
5. data processing and controlling software; 
6.a set of protective casing. 
]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[Vacuum Leak Tester for Packaging Plastic Bag Heat Seal Strength Leakage Tester ASTM D3078 Tester]]></title><link><![CDATA[https://celtec.en.ec21.com/Vacuum_Leak_Tester_for_Packaging--9267516_9168922.html]]></link><description><![CDATA[set vacuum level is attained. Should even a minor leak be present, the ensuing pressure differential forces trapped air out, manifesting as observable bubbles from the leakage point.
Technical Specif]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[Ozone Test Chamber,Ozone Colorfastness Tester AATCC 109 ISO 105 G03 ASTM D1149]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Ozone_Test_Chamber_Ozone_Colorfastness--5441143_9547155.html]]></link><description><![CDATA[generator, touch screen controller, closed-loop ozone concentration 
control and a rotating sample hanger that can hold up to 24 specimens. 
3. Easy set-up features allow both set and current test pa]]></description><pubDate><![CDATA[20200216]]></pubDate></item>
<item>
<title><![CDATA[Tensile Tester]]></title><link><![CDATA[https://pnshar.en.ec21.com/Tensile_Tester--6815941_6804873.html]]></link><description><![CDATA[set digitally) 5. Minimum distinguishhability: 0.1N (When 0~30N, the distinguishability is 0.01N) FEATURES 1. Vertical structure with selectable velocity between 1~400mm/min 2. Large tensile running ]]></description><pubDate><![CDATA[20120619]]></pubDate></item>
<item>
<title><![CDATA[Ponovo NF802 IEC61850 Protection Digital Relay Test Kit for Digital Substations]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_NF802_IEC61850_Protection_Digital--11744131_7404154.html]]></link><description><![CDATA[Set rangeAC:0～7.07Vrms DC:0～10VAccuracy0.07~7.07Vrms : &lt; 0.2%
0.02~0.07Vrms : &lt; 1%
Frequency
Sinusoidal signal10～1000HzTransient signalDC～10.0kHzAccuracy0.002%(under frequency,error 1mHz)Reso]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Fuel Octane Rating Engine Equipment with XCP Octane System ASTM D2699 D2700]]></title><link><![CDATA[https://sinpar.en.ec21.com/Fuel_Octane_Rating_Engine_Equipment--9761102_11911427.html]]></link><description><![CDATA[set &amp; auto-calculation system, integrated maintenance logs, and comprehensive safety system. 
Octane Testing Engine Applications
FTC-M2 Octane Testing Engine applies to the user who has the requireme]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[Electrodynamic Vibration Generator System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Electrodynamic_Vibration_Generator_System--9657760_11802794.html]]></link><description><![CDATA[set the acceleration and amplitude.
Specifications:• Vibration table size: 500*500mm (Other size can be designed)• Vibration: 0~5mm (Adjustable range P-P). Vibration waveform: sine wave (half wav]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[NAMS (Rack-mounted)]]></title><link><![CDATA[https://xinertel.en.ec21.com/NAMS_Rack_mounted--10761704_10761759.html]]></link><description><![CDATA[generating 
Wire-speed packet capturing Index powered fast packet retrieval 
Embedded packet analyzer for ultra-fast packets decoding and troubleshooting decoding and troubleshooting 
Flexible monito]]></description><pubDate><![CDATA[20190419]]></pubDate></item>
<item>
<title><![CDATA[NAYD Series Oil Gas Dry Type Testing Transformer]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/NAYD_Series_Oil_Gas_Dry--10586983_10725192.html]]></link><description><![CDATA[set; Cascade type high voltage testing transformer; Oil-immersed testing transformer; Oil type test transformer; Gas type test transformer, SF6 gas-typed test transformer, SF6 gas-insulated testing t]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Made in China HZ-3120A Automatic Transformer DC Winding Resistance Tester]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Made_in_China_HZ_3120A--10544358_10544703.html]]></link><description><![CDATA[generator,testing transformer,insulating oil tester, like transformer oil dielectric tester (BDV tester), transformer loss tester, transformer oil acid tester, flash point tester and so on. The produ]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[KRD12 Pneumatic Horizontal Shock Test System]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD12_Pneumatic_Horizontal_Shock_Test--11098426_11099351.html]]></link><description><![CDATA[set, system will automatically control the shock speed
with high accuracy and good repeatability. l 
Adopts the high strength and hardness cast aluminum table , which has high first-order resonance f]]></description><pubDate><![CDATA[20240329]]></pubDate></item>
<item>
<title><![CDATA[Electric Motor Stator Testing Equipment for Production Line]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/Electric_Motor_Stator_Testing_Equipment--11085938_11085939.html]]></link><description><![CDATA[generally 20℃
or 25℃) automatically. 
measuring range and precision
10.0mΩ～20KΩ ±(0.3%×display value+3 words) temperature compensation can be set
test time range/resolution
0.5～999s 0.1s/]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[set
Mobile workbench
Upper, middle and lower three layers of high-precision iron castings
1 set
V-guide XY
High precision Taiwan Shangyin
3 sets
Linear guide Z
Taiwan Shangyin class P
1 set
Grating r]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Multi-channel Multi-function Intelligent Temperature and Humidity Itinerant Detector]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Multi_channel_Multi_function_Intelligent--11689589_11689607.html]]></link><description><![CDATA[general tool software such as Excel, or imported into special software for data analysis, report generation and certificate output. Large-capacity memory solves the problem of data security and non-v]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Photocatalytic Xenon Lamp Light Source Photocatalysis Photocatalytic Visible Light UV Light]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Photocatalytic_Xenon_Lamp_Light_Source--11446837_11446862.html]]></link><description><![CDATA[General Optical Filters
AREF(Full Reflective，200-2500nm) - Default included with lamp set
VisREF (Reflect Visible Light, 350-780nm)
UVREF (Reflect UV, 200-400nm)
AM1.5G (300-1100nm)
UVIRCut400 (Ban]]></description><pubDate><![CDATA[20240104]]></pubDate></item>
<item>
<title><![CDATA[Automatic Capacitance and Dissipation Factor Test Set]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Automatic_Capacitance_and_Dissipation_Factor--11895397_11895406.html]]></link><description><![CDATA[set
Product Description
Hengfeng tan delta tester
measures the capacitance and dissipation factor factor (tgδ) of high voltage electric equipment.
12KV high voltage is generated by internal transfor]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[Lt-JJN01 Computerized Five-Jaw Office Chair Foots Static Pressure Test Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Lt_JJN01_Computerized_Five_Jaw--11365007_11365038.html]]></link><description><![CDATA[set of clamping device14. Motor: Panasonic servo motor, Japan Standards
QB/T 2280-2016; QB/T 2602-2013; BIFMA X5.1-2017; EN 1335:2000
Product Usage
This machine is used to evaluate the compressive st]]></description><pubDate><![CDATA[20210410]]></pubDate></item>
<item>
<title><![CDATA[Computer Control YFT-300 Claws Clamping Type Hydraulic Valve Test Bench for Test Flange End Valves]]></title><link><![CDATA[https://king3834656.en.ec21.com/Computer_Control_YFT_300_Claws--11745449_11745450.html]]></link><description><![CDATA[set on both sides of workbench to move synchronously in radial direction and to clamp and release synchronously in axial direction. And the right workbench can be turned over with an angle of 0~90°t]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61000_4_5_Lightning_Surge--11421920_11421956.html]]></link><description><![CDATA[set at 0－360°，resolution:1°
Trigger mode
Auto or manual, single
Surge times
1-9999 times
Memories
1000 groups
Surge interval
20-9999s
Accuracy:
5％
CDN
AC：single phrase 300V，10A（16AMax]]></description><pubDate><![CDATA[20210729]]></pubDate></item>
<item>
<title><![CDATA[Intelligent Temperature Measuring Machine]]></title><link><![CDATA[https://auroraguoxia12.en.ec21.com/Intelligent_Temperature_Measuring_Machine--11599950_11770469.html]]></link><description><![CDATA[General parametersspeaker4Ω3WOSD languageMulti-language OSD operation in Chinese and EnglishProtection levelSupport waterproof and dustproof, can support outdoor useadapterPower adapter 12V/2Aequipm]]></description><pubDate><![CDATA[20230417]]></pubDate></item>
<item>
<title><![CDATA[MDKN Gas Meter Endurance Test Bench]]></title><link><![CDATA[https://royreal.en.ec21.com/MDKN_Gas_Meter_Endurance_Test--11907986_11909882.html]]></link><description><![CDATA[set. The system defaults to 25,000 times, 150,000 times, 300,000 times and 450,000 times.2) The test pressure controlled between 2kPa and 2.5kPa, and the maximum pressure change not exceed ±300Pa.3.]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/3kW_3.5kW_4kW_5kW_6kW--11807084_11807114.html]]></link><description><![CDATA[general length 1.5/2Mtr,the cable length can be customized)Maximum step1000WLoad Steps1000W,1000W,1000WLoad accuracy (per step)±2%Insulation classFWorking modeContinuous workCooling modeForced air c]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[High Purity Gas Generator, Hydrogen Generator, Nitrogen Generator]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/High_Purity_Gas_Generator_Hydrogen--11907876_11909357.html]]></link><description><![CDATA[generator for gas chromatographs:
Technical parameters: high-purity hydrogen, high-purity nitrogen
Gas purity (%)&gt;99.999
Output flow rate (ml/min) 0-300 0-500
Output pressure (MPa) 0.4 (factory set a]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[Salt Spray Test | Salt Spray Test Chamber]]></title><link><![CDATA[https://15317383997.en.ec21.com/Salt_Spray_Test_Salt_Spray--11812738_11858086.html]]></link><description><![CDATA[general natural environment, which greatly increases the corrosion rate. The salt spray testing of the product can greatly shorten the time to obtain the result. For example, if a product is tested i]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[SciAps X-555 Handheld XRF Analyzer]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/SciAps_X_555_Handheld_XRF--11834264_11834285.html]]></link><description><![CDATA[set it in position, start the analysis, and go do other tasks while the data is collected.[/caption]If you have to find some shade and wait for the instrument to cool off before continuing to collect]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[EnviClone IEC 61215 From IPX1 Through IPX6 Combined Water Rain Drip Spray Flush Test Chamber]]></title><link><![CDATA[https://enviclonetestchamber.en.ec21.com/EnviClone_IEC_61215_From_IPX1--11887750_11887752.html]]></link><description><![CDATA[set in the controlling system.Illumination LampWith long lifetimeWater RequiredPurified and softened running water.Structure &amp; MaterialsExternal CasingA3 (Q235) steel plates with plastics coated, rus]]></description><pubDate><![CDATA[20240113]]></pubDate></item>
<item>
<title><![CDATA[Automatic Melting Point Tester]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Automatic_Melting_Point_Tester--11600339_11776721.html]]></link><description><![CDATA[Generally, it will take 7 to 15 working days after receiving your advance payment. Depend on the quantity.&quot;
Q:Which payment can be acceptable ?
A:We could accept the payment by L/C, TF, Paypal , West]]></description><pubDate><![CDATA[20230426]]></pubDate></item>
<item>
<title><![CDATA[ISO 15105-2 Permeable Film Oxygen Transmission Rate Tester GBPI]]></title><link><![CDATA[https://gbpitester.en.ec21.com/ISO_15105_2_Permeable_Film--11629254_11631099.html]]></link><description><![CDATA[set test process.
3)Fully-auto operation, judge and stop automatically. 
4)Real time curves display of transmission, oxygen concentration, temperature and humidity, curves can be easily zoomed and mo]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Conradson Carbon Residue of Petroleum Products Tester]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Conradson_Carbon_Residue_of_Petroleum--11718430_11856619.html]]></link><description><![CDATA[standard requirements;
4. A complete set of instruments includes: fire bridge, round iron cover, outer iron crucible, porcelain crucible, inner iron crucible, flame shield, tripod and blowtorch.
]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[ZXUD - 40 Digital Truecolor Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ndtchina.en.ec21.com/ZXUD_40_Digital_Truecolor_Ultrasonic--6581053_6161468.html]]></link><description><![CDATA[generator set and multi-pole damping set, making the probe and the detector match up.
Optimizing pulse repetition frequency control, good dynamic effect of echo pulse, no lag, meeting the demand of d]]></description><pubDate><![CDATA[20140520]]></pubDate></item>
<item>
<title><![CDATA[Programmable Anti-yellowing Resistance Corrosion Tester]]></title><link><![CDATA[https://annie0423.en.ec21.com/Programmable_Anti_yellowing_Resistance_Corrosion--9938796_9938804.html]]></link><description><![CDATA[General guidance
(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps
(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics
(6]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>