<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - angle measure instrument]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/angle_measure_instrument--2717/1/angle measure instrument.html]]></link><item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[instrument;
★Operation setting: Pre-set 6 commonly used voltage measurement modes to meet the needs of conventional instrument testing;
Chinese/English voice broadcast, the volume is adjustable;
Fl]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[WDLYCH/WDLHCN CCS Marine Analog Panel Current Meter/Ammeter for Switchboards]]></title><link><![CDATA[https://jade900920.en.ec21.com/WDLYCH_WDLHCN_CCS_Marine_Analog--11663243_12026218.html]]></link><description><![CDATA[measuring AC/DC current measurement
Overshoot
Less than 20% when scale reaches to 2/3
Insulation
Circuit &amp; shell: AC2600V/1 minute(Water area)
Indicating Angle
90/240-270°
Temperature
-13-33℃, 100]]></description><pubDate><![CDATA[20241227]]></pubDate></item>
<item>
<title><![CDATA[YH701 Temperature and Humidity Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH701_Temperature_and_Humidity_Calibration--12022540_12022544.html]]></link><description><![CDATA[measurement standard and can be separated. This device is mainly used to detect hair temperature and humidity meters, dry and wet bulb thermometers, digital temperature and humidity meters, and other]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Ultrasonic_Flaw_Detector--11973711_11973715.html]]></link><description><![CDATA[Angles and K-value; 
● Lock and unlock function of system parameters;
● Electronic clock calendar ; 
● Two gates setting and alarm indication;
● Gate and DAC alarm;
Specification
Measuring Ra]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[Gear Measuring Machine for Worm Wheel Rotary Table,Bevel Gear,]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Gear_Measuring_Machine_for_Worm--11944568_11945231.html]]></link><description><![CDATA[Measurable spiral angle range
0～90° 
Distance between top and bottom tips（㎜）
10～500 
10～800
10～1000 
10～1000
10～1000 
10～1000 
Vertical measurement range（㎜）
400 
400
600 
6]]></description><pubDate><![CDATA[20240531]]></pubDate></item>
<item>
<title><![CDATA[EHP210 Leeb Digital Hardness Tester]]></title><link><![CDATA[https://mikrometry.en.ec21.com/EHP210_Leeb_Digital_Hardness_Tester--11911431_11911439.html]]></link><description><![CDATA[EHP210 is a light and portable tester. With 5 inch touch screen design. It is most suitable for testing of heavy, big or outdoor metal parts. It can measure in any direction and also easy to be used ]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/Used_Olympus_Nortec_600D_Eddy--11801594_11801596.html]]></link><description><![CDATA[measurements and 1 angle measurement).Eddy Current Specifications (all NORTEC models)Probe typesAbsolute and differential in either bridge or reflection configuration. The instrument is fully compati]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[LED Power Driver Tester]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/LED_Power_Driver_Tester--11882688_11882697.html]]></link><description><![CDATA[LS2090 LED Power Driver Test Instrument is the comprehensive test instrument for LED driver power which is according to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters: in]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[High Precision Rotation Luminaire Goniospectroradiometer]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Precision_Rotation_Luminaire_Goniospectroradiometer--11812738_11812746.html]]></link><description><![CDATA[Angle accuracy: LSG-1890BCCD is 0.1°, LSG-1800ACCD is 0.2°• Work with high accuracy and quick CCD Spectroradiometer to measure spatial color parameters• Accuracy of chromaticity coordinate: ±0]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Power Quality Analyzer(3P)]]></title><link><![CDATA[https://tekon1.en.ec21.com/Power_Quality_Analyzer_3P--11010564_11156920.html]]></link><description><![CDATA[measurements
• Simultaneously measures active/reactive/apparent power, power factor, RMS voltage/ current, phase angle and neutral line current
• Supports a variety of wiring such as single-phase]]></description><pubDate><![CDATA[20201231]]></pubDate></item>
<item>
<title><![CDATA[300J Metal Material Automatic Charpy Pendulum VU-notch Used Izod Laboratory  Impact Tester]]></title><link><![CDATA[https://astmtester123.en.ec21.com/300J_Metal_Material_Automatic_Charpy--9999931_10000030.html]]></link><description><![CDATA[instrument in research institutes to conduct studies of new materials.
4. It is for the pendulum-type impact testing, using PC computer control, electric Yang pendulum,impact, computer measurement, c]]></description><pubDate><![CDATA[20190815]]></pubDate></item>
<item>
<title><![CDATA[300J Metal Material Automatic Charpy Pendulum VU-notch Used Izod Laboratory Usage Impact Tester]]></title><link><![CDATA[https://lgtester789.en.ec21.com/300J_Metal_Material_Automatic_Charpy--10000304_10000373.html]]></link><description><![CDATA[instrument in research institutes to conduct studies of new materials.
4. It is for the pendulum-type impact testing, using PC computer control, electric Yang pendulum,impact, computer measurement, c]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[Digital Halogen Moisture Analyzer]]></title><link><![CDATA[https://xmkwdz.en.ec21.com/Digital_Halogen_Moisture_Analyzer--10227578_10236597.html]]></link><description><![CDATA[Machine, CNC Router, UV Line, Press, etc. 
6. Glass Machine: Edge grinding machine, bevelling machine, angle-changing edging machine, sandblasting machine, drilling machine, washing machines, etc.]]></description><pubDate><![CDATA[20161204]]></pubDate></item>
<item>
<title><![CDATA[High Precision Rotation Luminaire Goniophotometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High_Precision_Rotation_Luminaire_Goniophotometer--9657760_11802783.html]]></link><description><![CDATA[measurements with facility for rotating the light source. The LSG-1890B/LSG-1800A uses a constant temperature detector, Japanese motor and German precision angle coder which keep the test results wit]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[AS-2011 Micron Laser Particle Size Analyzer 0.1-500um]]></title><link><![CDATA[https://aimsizer.en.ec21.com/AS_2011_Micron_Laser_Particle--4628668_4628669.html]]></link><description><![CDATA[angle 21.5 degree. Crossly positioned irregular side array comprises 5 photocells with maximum angle 75 degree.
Technologies of software
-Two login ports one for the administrator the other for the o]]></description><pubDate><![CDATA[20100926]]></pubDate></item>
<item>
<title><![CDATA[JB-300W Microcomputer Controlled Impact Testing Machine]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/JB_300W_Microcomputer_Controlled_Impact--6651349_6678504.html]]></link><description><![CDATA[instrument in research institutes to conduct studies of new materials. It is for the pendulum-type impact testing, using PC computer control, electric Yang pendulum, impact, computer measurement, com]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[NACTP Automatic CT PT Comprehensive Analyzer]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/NACTP_Automatic_CT_PT_Comprehensive--10586979_10716664.html]]></link><description><![CDATA[angle difference for all kinds of CT (such as protective type, measuring type and TP), but also can test the VA rating curve, ratio, polarity, secondary winding resistance, phase or angle difference ]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Horizontal and Vertical Flammability Tester UL94 IEC 60695]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Horizontal_and_Vertical_Flammability_Tester--5441143_9767620.html]]></link><description><![CDATA[angle, then observe whether it is burned,and use The burning time and burning length to 
evaluate fire risk . 
2.This tester is used for the flammability testing of plastic materials such as V-0 V-1 ]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Made in China HZ-3120A Automatic Transformer DC Winding Resistance Tester]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Made_in_China_HZ_3120A--10544358_10544703.html]]></link><description><![CDATA[measured voltage,current, power, frequency, impedance, phase angle and other data when measuring, to better analyze the quality of the test product 
The instrument uses 8.0 inches 800 × 600 dot matr]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[Gfuve Handheld Three Phase Energy Meter Calibrator]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/Gfuve_Handheld_Three_Phase_Energy--10658139_11236551.html]]></link><description><![CDATA[Measure reactive power of three phase or single phase.Measure apparent power of three phase or single phase.Measure power factor of three phase or single phase.Measure phase angle between voltage and]]></description><pubDate><![CDATA[20200820]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Surface Roughness Tester SRT-6200]]></title><link><![CDATA[https://105landtek.en.ec21.com/Hot_Sale_Surface_Roughness_Tester--9545708_11803265.html]]></link><description><![CDATA[Measurement Force of Probe
16 mN（1.6 gf）
Probe Angle
90°
Vertical Radius of Guiding Head
48 mm
Maximum driving stroke
17.5 mm / 0.7 inch
Cutoff length (l)
0.25 mm / 0.8 mm / 2.5 mm optional
Driv]]></description><pubDate><![CDATA[20230607]]></pubDate></item>

</channel>
</rss>