<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - at $1]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/at_$1--2717/1/at $1.html]]></link><item>
<title><![CDATA[Fluke 87V Industrial Multimeter 2025]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_87V_Industrial_Multimeter_2025--11790575_11793411.html]]></link><description><![CDATA[19,999 counts in high–resolution modeAnalog32 segments, updates 40/secFrequency19,999 counts, updates 3/sec at &gt; 10 HzWarrantyLifetimeBattery LifeAlkaline~400 hours typical, without backlightShock1]]></description><pubDate><![CDATA[20250321]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_TI480_PRO_Thermal_Imaging--12045274_12045346.html]]></link><description><![CDATA[10 °C): ≤-20 °C to 1000 °C (-4 °F to 1832 °F)Accuracy: ±2 °C or 2% (at 25 °C nominal, whichever is greater)Thermal sensitivity (NETD)*: ≤0.05 °C at 30 °C target temp (50 mK)On-screen em]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Valid Magnetics Air Cooled / Blower Hysteresis Dynamometer for Motor Test, Torque, Speed and Power]]></title><link><![CDATA[https://validmagnetics.en.ec21.com/Valid_Magnetics_Air_Cooled_Blower--8979451_8979479.html]]></link><description><![CDATA[1% full scale, depending on size and system configuration. Fine adjustment for optimization can be done with the support of our own invented dynamotmeter controller. It has high cost/performance rati]]></description><pubDate><![CDATA[20250205]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO 60 Hz, 640 X 480 High-Performance IR Thermal Camera]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_TI480_PRO_60_Hz--11561118_11932301.html]]></link><description><![CDATA[at 30 �C target temp (50 mK)
Temperature measurement range (not calibrated below -10 �C): ?-10 �C to +1000 �C (14 �F to 1832 �F)
Accuracy: � 2 �C or 2% (at 25 �C nominal, whichever ]]></description><pubDate><![CDATA[20250129]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[152 M)Accuracy± 2 °C or 2% (at 25 °C nominal, whichever is greater)Battery operating time Continuous3 HRCamera LightYesIR Digital ZoomYes Voice AnnotationYesTest Equipment General AttributesUnique]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[WDLYCH/WDLHCN CCS Marine Analog Panel Current Meter/Ammeter for Switchboards]]></title><link><![CDATA[https://jade900920.en.ec21.com/WDLYCH_WDLHCN_CCS_Marine_Analog--11663243_12026218.html]]></link><description><![CDATA[100A Marine analog panel ammeter
Function
Used for measuring AC/DC current measurement
Overshoot
Less than 20% when scale reaches to 2/3
Insulation
Circuit &amp; shell: AC2600V/1 minute(Water area)
Indic]]></description><pubDate><![CDATA[20241227]]></pubDate></item>
<item>
<title><![CDATA[Automatic Torque Tester (Automatic Sampling)]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Automatic_Torque_Tester_Automatic_Sampling--12024209_12033013.html]]></link><description><![CDATA[12 samples, then automatically sampling by conveyor belt. The sample will be measured automatically once arrived at the measurement station and avoid the influence of human factors.
Advantages:
1) To]]></description><pubDate><![CDATA[20241225]]></pubDate></item>
<item>
<title><![CDATA[Laser Distance Meter 100m]]></title><link><![CDATA[https://holo1.en.ec21.com/Laser_Distance_Meter_100m--11942959_11943117.html]]></link><description><![CDATA[at high altitude, the laser rangefinder can easily handle
100 meters, ensuring the accuracy and reliability of measurement.
In addition, laser distance meter 100m also has the advantages of versatili]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[Heat Alarm &amp; Detector Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Heat_Alarm_Detector_Test_Tunnel--11987076_11987723.html]]></link><description><![CDATA[1 ℃/min, 3 ℃/min, 5 ℃/min,
10 ℃/min, 20 ℃/min and 30 ℃/min as standard required. The maximum temperature is up to 160 ℃. During the test, the temperature will be controlled at + / - 2 ]]></description><pubDate><![CDATA[20241122]]></pubDate></item>
<item>
<title><![CDATA[Frog Vertical Wear Gauge]]></title><link><![CDATA[https://420621199211083365.en.ec21.com/Frog_Vertical_Wear_Gauge--12024098_12024113.html]]></link><description><![CDATA[PRODUCT DESCRIPTIONFrog vertical wear gauge is used to measure vertical wear value of frog point rail and wing rail at any sections.Also could be used for measuring decrease value of point rail relat]]></description><pubDate><![CDATA[20241113]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[1B-3LJ450×450×500Subject to contractual three-viewLRHS-225B-3LJ500×600×750temperature rangeA:-20℃～150℃ B:-40℃～150℃C:-60℃～150℃ D:-70℃～150℃Temperature uniformity≤2℃ (at ]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[YH800F Portable Fully Automatic Pressure Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800F_Portable_Fully_Automatic_Pressure--12022422_12022441.html]]></link><description><![CDATA[1.PP safety protection box: The safety protection box is made of high-strength PP material, which has excellent impact resistance and corrosion resistance, ensuring the safety and durability of the d]]></description><pubDate><![CDATA[20241105]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale DN200 Portable Pneumatic Safety Relief Valve Test Bench for Flanged Valves]]></title><link><![CDATA[https://shineeast2024.en.ec21.com/Hot_Sale_DN200_Portable_Pneumatic--11996822_12014365.html]]></link><description><![CDATA[Hot sale DN200 portable pneumatic safety relief valve test bench for flanged valves
Standard configuration 1:
- Model: SVTH-15-DN200
- Test pressure: 15 Mpa
- Diameter: ≤200mm
- Single chuck
- With]]></description><pubDate><![CDATA[20241007]]></pubDate></item>
<item>
<title><![CDATA[Dissolved Ozone Meter Intelligent Online Water Ozone Analyzer Tester Sanitizer Ozone]]></title><link><![CDATA[https://nobotech.en.ec21.com/Dissolved_Ozone_Meter_Intelligent_Online--11181496_11182362.html]]></link><description><![CDATA[at the same time he also has RS485 communication, you can connect our DTU through RS485 communication, and then use Mobile phone or computer can view data in real time.
NOBO brand website ：http://w]]></description><pubDate><![CDATA[20240929]]></pubDate></item>
<item>
<title><![CDATA[UTOCO Handheld Laser Detector with Tdlas for Natural Gas Distribution Pipeline]]></title><link><![CDATA[https://utoco.en.ec21.com/UTOCO_Handheld_Laser_Detector_with--12010082_12010092.html]]></link><description><![CDATA[at 5 ppm·m with no alarm delay.
One-button operation with a color LCD display.
Visual, audible, and vibration alerts with adjustable levels.
Shockproof, low power consumption, and intrinsically safe]]></description><pubDate><![CDATA[20240926]]></pubDate></item>
<item>
<title><![CDATA[Portable Hardness Tester]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Portable_Hardness_Tester--11973711_12009824.html]]></link><description><![CDATA[Portable Hardness Tester
Features
● Compact plastic case, suitable for use under poor working conditions. Test at any angle, even upside down.
● Wide measuring range. It can measure the hardness ]]></description><pubDate><![CDATA[20240925]]></pubDate></item>
<item>
<title><![CDATA[EMCEE Model 1153 Digital Conductivity Meter]]></title><link><![CDATA[https://xmjielian.en.ec21.com/EMCEE_Model_1153_Digital_Conductivity--11982130_11982346.html]]></link><description><![CDATA[Model 1153 Digital Conductivity Meter(ASTM Standard Test Method D2624 included in Specifications D975, D1655, and D7566)
Continuous standard electrical conductivity range from 1 to 2,000 picosiemens ]]></description><pubDate><![CDATA[20240813]]></pubDate></item>
<item>
<title><![CDATA[Steel Bar/Steel Tube/Steel Pipe/Rebar Bending Testing Machine]]></title><link><![CDATA[https://lgtester4.en.ec21.com/Steel_Bar_Steel_Tube_Steel--9978752_10041383.html]]></link><description><![CDATA[at the same time it apply to the scene of reinforced bending in the construction industry and dual-use one machine in construction and testing.
The GW-50B type is that the replacing product of the fo]]></description><pubDate><![CDATA[20240803]]></pubDate></item>
<item>
<title><![CDATA[Wireless LoRaWAN Temperature and Vibration Sensor Industrial LoRa IoT Solution for Smart Industry]]></title><link><![CDATA[https://winext2024.en.ec21.com/Wireless_LoRaWAN_Temperature_and_Vibration--11976761_11977241.html]]></link><description><![CDATA[1-1.99mm/s;
Ø Frequency Response Range:＜1000Hz
Ø High Accuracy:±10%@100Hz;
Ø Temperature Measurement Range: -40~125 ℃;
Ø Temperature Accuracy: ±0.1℃ (At stable temperature conditions);
Ø]]></description><pubDate><![CDATA[20240730]]></pubDate></item>
<item>
<title><![CDATA[NDJ-8T Lab Digital Rotating Viscosity Meter Viscosimeter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_8T_Lab_Digital_Rotating--11144324_11144457.html]]></link><description><![CDATA[12/30/60
0.3/0.6/1.5/3/6/12/30/60
Measuring range 
1~100000mPa.s
1~2000000mPa.s
(1-10mPa.s, need to choose 0# rotor)
Rotor
1 - 4# (standard); 0# rotor (optional)
Measurement error (Newtonian liquid)
]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Cuvettes&amp;Cuvettes(Glass)&amp;Cuvettes (Quartz)]]></title><link><![CDATA[https://biogene123.en.ec21.com/Cuvettes_Cuvettes_Glass_Cuvettes_Quartz--11963552_11963584.html]]></link><description><![CDATA[at room temperature.
2.
Product Information
Cat. No.Product NameSizeFeaturePackageBCQ-5Cuvette5mmquartz2pcs/boxBCQ-10Cuvette10mmquartz2pcs/boxBCQ-20Cuvette20mmquartz2pcs/boxBCQ-30Cuvette30mmquartz2pc]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[2 Axis 2 Frame POD Multiple Spectral Electro Optic Camera Sensor 4.5kg]]></title><link><![CDATA[https://leadir.en.ec21.com/2_Axis_2_Frame_POD--11958808_11958803.html]]></link><description><![CDATA[12
Operating waveband Range
8-12μm
FOV
7.3° 
x 5.8
°(±5%)
Focal Length
60mm at F1.0
Detection Range
For humans(0.5m x 1.8m)≥1.8km,for vehicles(4m x 6m)≥4.0km
Identification Range
For humans(0]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[108L Salt Spray Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/108L_Salt_Spray_Chamber--11164019_11164134.html]]></link><description><![CDATA[1.00±0.01kgf/cm2
Spray volume
1.0~2.0ml/80cm2/h (at least collecting 16 hours and take the average value)
Relative humidity in the lab
Above 85%
Value PH
6.5~7.2, 3.0~3.2
Spray method
Programmable s]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[ST-6608 Static Force Test Machine]]></title><link><![CDATA[https://satatec.en.ec21.com/ST_6608_Static_Force_Test--7687564_7687808.html]]></link><description><![CDATA[at elevated temperature etc.
Technical parameters:
Test workstation: 6 groups of specimens;
Weight: 2Lb, 5Lb, 8Lb &amp; 10Lb, each 6pcs and portfolio stackable the weight suitable difference specimen for]]></description><pubDate><![CDATA[20240614]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-2 Electrostatic Discharge Generator with 20KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_2_Electrostatic_Discharge--11944039_11946383.html]]></link><description><![CDATA[1000-4-2，GB/T 17626.2
Rising time:
0.8ns ±25％
First peak current
7.5A ±15％ @ 2kV
15A ±15％ @ 4kV
22.5A ±15％ @ 6kV
30A ±15％ @ 8kV
Current at 30ns
4.0A ±30％ @ 2kV
8.0A ±30％ @ 4kV
]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[GS-SW640171550-UC-CL Uncooled SWIR Camera]]></title><link><![CDATA[https://gatherstar.en.ec21.com/GS_SW640171550_UC_CL_Uncooled--11943440_11943469.html]]></link><description><![CDATA[12
Pixel size 
15μm
Active area 
9.6mm x 7.68mm
Quantum efficiency 
&gt;70%@（1.0μm-1.6μm）
Pixel o perability 
＞99.5%
Cooler type 
Uncooled
Maximum frame rate 
50Hz
ROI 
Support ROI at any posit]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[1) short circuit permanent fault indicating: Six piece 3-color led will shine flash red color, and four times,
every 2 second，And turn to red flag at same time。
2) short circuit temporary fault i]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[Radiation Detectors]]></title><link><![CDATA[https://radsafetech.en.ec21.com/Radiation_Detectors--11848452_11938482.html]]></link><description><![CDATA[at the Schneefernerhaus, Germany&apos;s highest environmental research station, is equal to approximately 110 µSv/h. At PCE Instruments you will find three types of Geiger counters or nuclear radiation d]]></description><pubDate><![CDATA[20240517]]></pubDate></item>
<item>
<title><![CDATA[Gravimetric Water Meter Test Bench]]></title><link><![CDATA[https://tnmacalibration.en.ec21.com/Gravimetric_Water_Meter_Test_Bench--11926262_11934189.html]]></link><description><![CDATA[Gravimetric Water Meter Test Bench
Product Description
Thiswater meter test bench use gravimetric method to test the ultrasonic water meter,mechanical water meter and electronic water meter from DN15]]></description><pubDate><![CDATA[20240509]]></pubDate></item>
<item>
<title><![CDATA[Original Schmidt Test Hammer  HT-225]]></title><link><![CDATA[https://198358.en.ec21.com/Original_Schmidt_Test_Hammer_HT--4030105_4030106.html]]></link><description><![CDATA[concrete test hammer (schmidt hammer)
Applied to test compressive strength of hardened concrete
Measuring ranges: 10-60MPa
Impact energy: 2.207J
Size: L280mm*D54mm
N W: 1kg
Concrete Test Hammers are ]]></description><pubDate><![CDATA[20240430]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[at 0 – 1 inH20 (0 – .25kPa) and go to 0 – 10,000 psi (0 – 70,000 kPa). Additional information about pressure modules is available on the Pressure Modules Home Page.
Automated Procedures 
Allo]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD61 6-DOF Motion Simulator Test System Simulation Table]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD61_6_DOF_Motion_Simulator--11098426_11099478.html]]></link><description><![CDATA[KRD61 6-DOF Test System
KRD61
series 6-DOF test system is a closed-loop servo simulation platform consisting
of six servo actuators and six sets of dedicated hinges connected at the top and
bottom pl]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Vacuum Leak Tester for Packaging Plastic Bag Heat Seal Strength Leakage Tester ASTM D3078 Tester]]></title><link><![CDATA[https://celtec.en.ec21.com/Vacuum_Leak_Tester_for_Packaging--9267516_9168922.html]]></link><description><![CDATA[at higher vacuum levels to meet specialized testing requirements.
Main Parameters 
Test Range 0~-90 KPa
Chamber Acrylic Cylinder Shape
Test Space Φ270*H210mm (Inside Usable)
Compressed Air 0.7MPa (P]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[E5071C ENA Vector Network Analyzers]]></title><link><![CDATA[https://dgqihang.en.ec21.com/E5071C_ENA_Vector_Network_Analyzers--11851310_11851311.html]]></link><description><![CDATA[at 201 Point, 1 Sweep:n/aComponents:n/aDynamic Range:123 dBHarmonics:-25 dBcMaximum Frequency:20 GHzNoise Floor:n/aNumber of Built-In Ports:2 or 4 portsNumber of Internal Sources:n/aOperating System:]]></description><pubDate><![CDATA[20231007]]></pubDate></item>
<item>
<title><![CDATA[CLEAN-EFF01 Cleaning Efficacy Tester]]></title><link><![CDATA[https://celtec3.en.ec21.com/CLEAN_EFF01_Cleaning_Efficacy_Tester--11861428_11861442.html]]></link><description><![CDATA[Application
Cleaning materials are widely used at home, office, kitchen, bedroom, hotels, restaurants, washroom, industries etc. CLEAN-EFF01 Cleaning Efficacy Tester is suitable for cleaning performa]]></description><pubDate><![CDATA[20231101]]></pubDate></item>
<item>
<title><![CDATA[Bruker Tracer 5i Handheld XRF Spectrometer]]></title><link><![CDATA[https://thexrfstore.en.ec21.com/Bruker_Tracer_5i_Handheld_XRF--11822199_11822200.html]]></link><description><![CDATA[140 eV @ 250,000 cps Mn Kα; resolution for optimum light element analysis.Analysis range: Detects from Na to U; analyzes from Mg - USize: 27.3 cm x 9.4 cm x 29.5 cm (10.75 in x 3.7 in x 11.6 in) L x]]></description><pubDate><![CDATA[20230720]]></pubDate></item>
<item>
<title><![CDATA[Salt Spray Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Salt_Spray_Test_Chamber--11853101_11854269.html]]></link><description><![CDATA[1.00±0.01 kgf/cm2
Spray
volume
1.0～2.0 ml/80cm2/h (at least collecting 16 hours and take the
average value)
Relative
humidity in the lab
above 85% 
Value PH
6.5～7.2, 3.0～3.2
Spray method
Progr]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[CDW-60 Impact Test Low Temperature Chamber / Environmental Chamber]]></title><link><![CDATA[https://astmtester123.en.ec21.com/CDW_60_Impact_Test_Low--9999940_10000040.html]]></link><description><![CDATA[At the same time, it can also be used for other low-temperature detection and testing.
Main technical parameters
1. The controlling temperature range: room temperature ~ -80 °c (room temperature: ]]></description><pubDate><![CDATA[20190815]]></pubDate></item>
<item>
<title><![CDATA[Low Temperature Meter / Impact Testing Machine]]></title><link><![CDATA[https://lgtester789.en.ec21.com/Low_Temperature_Meter_Impact_Testing--10000308_10000400.html]]></link><description><![CDATA[At the same time, it can also be used for other low-temperature detection and testing.
Main technical parameters
1. The controlling temperature range: room temperature ~ -80 °c (room temperature: ]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[Medium Voltage Surge Arresters]]></title><link><![CDATA[https://yfpower.en.ec21.com/Medium_Voltage_Surge_Arresters--11836088_11836092.html]]></link><description><![CDATA[at voltages between 1kV and 36kV, and they are commonly found in various industries, such as manufacturing, oil and gas, and utilities.
Medium surge arrester medium voltage
work by detecting and dive]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[Plastic Moisture Analyzer]]></title><link><![CDATA[https://xmkwdz.en.ec21.com/Plastic_Moisture_Analyzer--10236594_10236600.html]]></link><description><![CDATA[at the same time, infrared heating units and fast drying moisture evaporating channel samples in the drying process, moisture meter shows the continuous measurement and real-time loss of sample moist]]></description><pubDate><![CDATA[20161204]]></pubDate></item>
<item>
<title><![CDATA[Torque Meter Tester Testing Measuring Machine 0.15~500kg]]></title><link><![CDATA[https://1987merch.en.ec21.com/Torque_Meter_Tester_Testing_Measuring--11291689_11672548.html]]></link><description><![CDATA[10.00
0.45~30.00
lbf.in
0.02~1.8
0.15~9.0
0.75~45.0
1.5~90.0
4.5~270.0
Accuracy of torque
±0.55
Display
LCD digit number
Measuring direction
Clockwise,anticlockwise
Mode of testing
PEAK
Display at t]]></description><pubDate><![CDATA[20221112]]></pubDate></item>
<item>
<title><![CDATA[Mattress Tester Machine]]></title><link><![CDATA[https://annie0423.en.ec21.com/Mattress_Tester_Machine--10805389_10805390.html]]></link><description><![CDATA[at up to 160 cycles per minute, variable. 
Specificationornell Mattress Tester Factory 
Design criteria: ASTM F 1566 
Test objectives: Use specific block impact on the mattress over and over again, t]]></description><pubDate><![CDATA[20180821]]></pubDate></item>
<item>
<title><![CDATA[5 PIN 12mm GX12-5 P Aviation Plug Interface Male Female Wire]]></title><link><![CDATA[https://tlsmic1.en.ec21.com/5_PIN_12mm_GX12_5--11014971_11016214.html]]></link><description><![CDATA[12mm GX12-5 P Aviation Plug Interface Male Female Wire
Jacket Material:
PVC
Length:
At least 0.1m, depends
Cable color:
Black White Red Blue Gray Grey
Pin Number:
2-23pin
working voltage:
DC 12-24V, ]]></description><pubDate><![CDATA[20201223]]></pubDate></item>
<item>
<title><![CDATA[2-IN-1 Digital Sound Level Meter Data Logger LD8506]]></title><link><![CDATA[https://ldmeter.en.ec21.com/2_IN_1_Digital_Sound--9759326_9810471.html]]></link><description><![CDATA[1/2 inch polarized condenser microphone
Frequency range:31.5~8000Hz
Accuracy:±1.5dB
Resolution:0.1dB
Data update:500ms
Response time:FAST 125 ms, SLOW 1 s
Standard calibrator:1KHz sine wave at 94 or]]></description><pubDate><![CDATA[20210415]]></pubDate></item>
<item>
<title><![CDATA[Automatic Safety Test System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Automatic_Safety_Test_System--9657760_11802784.html]]></link><description><![CDATA[1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It is used for luminaries, home application and motor tools safety test in production line or R&amp;D Lab.
Specification:• Re]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[140 ºF) with batteryStorage temperature range: –20 °C to 70 °C (–4 ºF to 158 ºF) without batteryRelative humidity: Max. 70% RH at 45°C noncondensingIngress protection rating: Designed to me]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[1.5 times of rated value.
Current-limit protection: User set current-limit value, output current will be limited at current-limit value when load has fault.
Short alarm: sound &amp; light alarm when outp]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Olympus EPOCH 6LT Ultrasonic Flaw Detector]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/Olympus_EPOCH_6LT_Ultrasonic_Flaw--11834264_11834279.html]]></link><description><![CDATA[1.95 pounds (890 g) with a grip-oriented weight distribution for one-handed operation with minimal wrist fatigueRotary knob and simple button design make it easy to use, even when wearing glovesEngin]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[DL400 Pro Smart Screen Tester]]></title><link><![CDATA[https://szdianliang.en.ec21.com/DL400_Pro_Smart_Screen_Tester--11842634_11842635.html]]></link><description><![CDATA[Product DescriptionThis DL400 Pro Smart Screen Tester not only clearly displays information, but also operates at a glance. Comprehensively detect screen display problems, display test pictures can b]]></description><pubDate><![CDATA[20230908]]></pubDate></item>

</channel>
</rss>