<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - at 500]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/at_500--2717/1/at 500.html]]></link><item>
<title><![CDATA[Fluke 87V Industrial Multimeter 2025]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_87V_Industrial_Multimeter_2025--11790575_11793411.html]]></link><description><![CDATA[500 °F, 2.2 °C or 2% whichever is greaterConductanceMaximum conductance60.00 nSAccuracy±(1.0% + 10)Maximum resolution0.01 nSDiodeRange3 VResolution1 mVAccuracy±(2% + 1)Duty cycle rangeAccuracyWit]]></description><pubDate><![CDATA[20250321]]></pubDate></item>
<item>
<title><![CDATA[Fluke 3540 FC KIT Three-Phase Power Monitor]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_3540_FC_KIT_Three--12045274_12045343.html]]></link><description><![CDATA[500 mVrms / 50 mVrms; CF 2.8
Rogowski coil: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe rangeBandwidth(-3 dB)42.5 Hz to 3.5 kHzScaling1:1 and variableData Acq]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Valid Magnetics Air Cooled / Blower Hysteresis Dynamometer for Motor Test, Torque, Speed and Power]]></title><link><![CDATA[https://validmagnetics.en.ec21.com/Valid_Magnetics_Air_Cooled_Blower--8979451_8979479.html]]></link><description><![CDATA[at
rated current
Kg·cm
Kinetic power(5 minutes)
Kinetic power(Continuous)
(rpm)Max speed
Coolingmode
Without air supply
With air supply
With blower
Without air supply
With air supply
With blower
HD ]]></description><pubDate><![CDATA[20250205]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[500×600×750temperature rangeA:-20℃～150℃ B:-40℃～150℃C:-60℃～150℃ D:-70℃～150℃Temperature uniformity≤2℃ (at no load)Temperature fluctuation±0.5℃(at no load)Time Setting R]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[Smoke Detector]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke_Detector--11987076_11987700.html]]></link><description><![CDATA[500ml provided
Particle size distribution between 0.5µm~1.0µm,
Smoke rising rate: 0.015 dB/m/min≤⊿m /⊿t ≤0.1dB/m/min,
preset to 0.05dB/m, which can be set in the software
6．
Optical smoke]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Portable Hardness Tester]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Portable_Hardness_Tester--11973711_12009824.html]]></link><description><![CDATA[Portable Hardness Tester
Features
● Compact plastic case, suitable for use under poor working conditions. Test at any angle, even upside down.
● Wide measuring range. It can measure the hardness ]]></description><pubDate><![CDATA[20240925]]></pubDate></item>
<item>
<title><![CDATA[108L Salt Spray Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/108L_Salt_Spray_Chamber--11164019_11164134.html]]></link><description><![CDATA[500 mm
800*1200*500 mm
1000*1600*500 mm
1200*2000*600 mm
External dimensions (D*W*H)
672*1150*1090 mm
842*1450*1200 mm
1240*2080*1285 mm
1450*2480*1520 mm
1650*2900*1550 mm
Lab Temperature
Saline tes]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Sand and Dust Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Sand_and_Dust_Test_Chamber--11853101_11854273.html]]></link><description><![CDATA[The
sand and dust test chamber, driven by a fan to push a certain concentration of
sand and dust to blow over the surface of the test piece at a certain flow rate,
simulates the typical environmental]]></description><pubDate><![CDATA[20240619]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator with 15KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_5_Lightning_Surge--11944039_11944066.html]]></link><description><![CDATA[500
Ω±10％
Trigger mode
Synchronization, 
asynchronization
Inject phase
Freely set at 0－360°，resolution:1°
Trigger mode
Auto or manual, single
Surge times
1-9999 times
Memories
1000 groups, ]]></description><pubDate><![CDATA[20240528]]></pubDate></item>
<item>
<title><![CDATA[Fluke 1587 FC Advanced Electrical Troubleshooting Kit]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_1587_FC_Advanced_Electrical--11927627_11927693.html]]></link><description><![CDATA[500 V, decreasing linearly to a crest factor =1.5 at 1000 V. For non-sinusoidal waveforms add ± (2 % reading + 2 % FS) typical, for a crest factor up to 3.Input Impedance10 MΩ (nominal), &lt;100 pF, a]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[at 0 – 1 inH20 (0 – .25kPa) and go to 0 – 10,000 psi (0 – 70,000 kPa). Additional information about pressure modules is available on the Pressure Modules Home Page.
Automated Procedures 
Allo]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD61 6-DOF Motion Simulator Test System Simulation Table]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD61_6_DOF_Motion_Simulator--11098426_11099478.html]]></link><description><![CDATA[KRD61 6-DOF Test System
KRD61
series 6-DOF test system is a closed-loop servo simulation platform consisting
of six servo actuators and six sets of dedicated hinges connected at the top and
bottom pl]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[EHS Shore Durometer Hardness Tester Unit]]></title><link><![CDATA[https://mikrometry.en.ec21.com/EHS_Shore_Durometer_Hardness_Tester--11911431_11911440.html]]></link><description><![CDATA[500 measurement data can be stored as one type of hardness test instrument, and the measurement data can be connected to PC software to export, built-in wireless printing function, you can connect wi]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[BST-01 Ampoule Breaking Tester]]></title><link><![CDATA[https://celtec3.en.ec21.com/BST_01_Ampoule_Breaking_Tester--11861428_11861434.html]]></link><description><![CDATA[at the speed of 10 mm/m. The breaking strength is detected by the high precision load cell when the pressing head touches ampoule neck and breaks it.
Technical Features 
BST-01 Ampoule Breaking Stren]]></description><pubDate><![CDATA[20231101]]></pubDate></item>
<item>
<title><![CDATA[Bruker Tracer 5i Handheld XRF Spectrometer]]></title><link><![CDATA[https://thexrfstore.en.ec21.com/Bruker_Tracer_5i_Handheld_XRF--11822199_11822200.html]]></link><description><![CDATA[at low power.Beam path: Capable of selectable beam path of vacuum, helium or air to detect elements as light as Fluorine (F) to as heavy as uranium (U).Internal camera: Internal VGA CMOS camera with ]]></description><pubDate><![CDATA[20230720]]></pubDate></item>
<item>
<title><![CDATA[300kN UTM / TTM / Tensile Test Equipment / Tensile Testing Machine Price (WEW-300B)]]></title><link><![CDATA[https://astmtester123.en.ec21.com/300kN_UTM_TTM_Tensile_Test--9999782_9999889.html]]></link><description><![CDATA[at room temperature tensile test method &quot;
2. The adoption of fuel tank under the rear-mounted, chain drive, hydraulic clamping.
3. The use of the brand computer to complete the course of the experime]]></description><pubDate><![CDATA[20190815]]></pubDate></item>
<item>
<title><![CDATA[WEW-300B 300kN Metal Material Universal Tensile Compression Bending and Shearing Testing Machine]]></title><link><![CDATA[https://lgtester789.en.ec21.com/WEW_300B_300kN_Metal_Material--10000280_10007507.html]]></link><description><![CDATA[at room temperature tensile test method &quot;
2. The adoption of fuel tank under the rear-mounted, chain drive, hydraulic clamping.
3. The use of the brand computer to complete the course of the experime]]></description><pubDate><![CDATA[20190821]]></pubDate></item>
<item>
<title><![CDATA[2-IN-1 Digital Sound Level Meter Data Logger LD8506]]></title><link><![CDATA[https://ldmeter.en.ec21.com/2_IN_1_Digital_Sound--9759326_9810471.html]]></link><description><![CDATA[500ms
Response time:FAST 125 ms, SLOW 1 s
Standard calibrator:1KHz sine wave at 94 ors 114dB
Display:3-1/2 digital LCD with analog bar-graph
Outputs:AC/DC signal output from earphone jack
AC=1Vrms ,D]]></description><pubDate><![CDATA[20210415]]></pubDate></item>
<item>
<title><![CDATA[LM-79 Moving Detector Goniophotometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/LM_79_Moving_Detector_Goniophotometer--11802221_11802222.html]]></link><description><![CDATA[5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The measuring d]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[500 models, output voltage: 0 ~ 800V, output current: 0 ~ 500A, output power: 0KW-400kW
Constant voltage mode and constant current mode, automatic switchable, output voltage / current continuously ad]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[500 mA power output line (short-circuit protected)Pace input: 5 V TTL pace inputDisplayDisplay size: 21.3 cm (8.4 in.) (diagonal)Resolution: 800 pixels x 600 pixelsBrightness: 600 cd/m2Viewing angles]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[ESD Simulator Guns]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/ESD_Simulator_Guns--11882688_11882699.html]]></link><description><![CDATA[at 30ns (A)Current at 60ns (A)Rise Time (ns)27.294.102.200.93415.407.904.300.97623.2012.106.500.97829.4016.209.300.89-27.393.502.300.92-415.507.704.300.89-623.4011.906.300.90-831.8016.108.200.90
]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Made in China HZ-3120A Automatic Transformer DC Winding Resistance Tester]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Made_in_China_HZ_3120A--10544358_10544703.html]]></link><description><![CDATA[At the same time it is possible to measure a variety of reactor inductance,The instrument can measure the current state of under-frequency, easy wiring, simple operation,
Reduce the burden of mainten]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[China Supplier LED Light Bulb Tube Lamp Power PF Voltage Current Power Meter]]></title><link><![CDATA[https://greenlight88.en.ec21.com/China_Supplier_LED_Light_Bulb--11401286_11401345.html]]></link><description><![CDATA[at home or laboratories.
Best after sales-services:
With 1 year warranty if non-human reason error, free of charge replacement is available.
Advantages:
*Compact design,easy to carry, you could check]]></description><pubDate><![CDATA[20210618]]></pubDate></item>
<item>
<title><![CDATA[Testing Equipment for Glass in Building]]></title><link><![CDATA[https://yuanchenwujin68.en.ec21.com/Testing_Equipment_for_Glass_in--11114426_11248640.html]]></link><description><![CDATA[500mm*3570mm
Samples Size:
1930mm*864mm
Lift: Electric
Release: Auto
Maximum impact
height: 1200mm (customized)
Rubber Pad
Width: 15mm
Rubber Pad
Thickness: 3mm
Rubber Pad
Hardness: Shore A50
Drop Ba]]></description><pubDate><![CDATA[20230719]]></pubDate></item>
<item>
<title><![CDATA[DCP, Australian Standard Dynamic Cone Penetrometer for Soil Compaction Testing]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/DCP_Australian_Standard_Dynamic_Cone--10975742_10975868.html]]></link><description><![CDATA[Please contact me with WeChat or WhatsApp, because I am Free Member.
16-T0012/P
pneumatic drive DPL Dynamic cone penetrometer for soil compaction testing 
$3,000.00 - $3,500.00 / Sets | 1 Set/Sets (M]]></description><pubDate><![CDATA[20230613]]></pubDate></item>
<item>
<title><![CDATA[Electric Motor Stator Testing Equipment for Production Line]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/Electric_Motor_Stator_Testing_Equipment--11085938_11085939.html]]></link><description><![CDATA[at one-stop
Easy-to-maintain: 
Multiple languages: multiple languages can be selected.
4. 
Technical specification
AC Hipot ： Applied AC high
voltage from the silicon steel sheet to iron core, and ]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[21.5 Inch Magazine Holder Digital Kiosk]]></title><link><![CDATA[https://rcstarsdisplay.en.ec21.com/21.5_Inch_Magazine_Holder_Digital--11540233_11857652.html]]></link><description><![CDATA[This digital board kiosk
has two different sizes, a 22 inch vertical screen / 32 inch horizontal screen, 500-4000 nits brightness optional, and capacitive touch or infrared touch options. The stand i]]></description><pubDate><![CDATA[20231023]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[500 *400*200
Overall dimension （mm）
825*1077*1280
Worktable （mm）
660*560
Overall weight (kg)
420
Glass load (kg)
20
Z-axis lifting distance
200MM
Working distance
90 mm
Measurement accuracy ]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Battery Quality Analyzer]]></title><link><![CDATA[https://tekon1.en.ec21.com/Battery_Quality_Analyzer--11010564_11156923.html]]></link><description><![CDATA[500V max of batteries
• Measures voltages at battery (DC1000V)
• Measures voltage of UPS (AC600V)
• Measures ripple voltage, current and temperature
• Diagnoses ageing of battery and predicts]]></description><pubDate><![CDATA[20201231]]></pubDate></item>
<item>
<title><![CDATA[High Temperature Oven]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/High_Temperature_Oven--11847960_11863734.html]]></link><description><![CDATA[500 ℃.
The heating method adopts hot air circulation, with rapid heating and uniform temperature distribution, ensuring that the entire sample is exposed to the same temperature to obtain consisten]]></description><pubDate><![CDATA[20231120]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/Used_Olympus_Nortec_600D_Eddy--11801594_11801596.html]]></link><description><![CDATA[500 files (program and data).On-board file preview.Portable and LightweightThe NORTEC 600 weighs only 1.6 kg and is delivered with a factory-installed hand strap that provides direct thumb access to ]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[High Purity Gas Generator, Hydrogen Generator, Nitrogen Generator]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/High_Purity_Gas_Generator_Hydrogen--11907876_11909357.html]]></link><description><![CDATA[500
Output pressure (MPa) 0.4 (factory set at 0.3) adjustable
Working power supply 110/220V ± 10%; 50/60Hz ± 5%
Maximum power (W) 200
Environmental conditions and temperature: 10-40 ℃; Relative h]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[LM-79 Moving Detector Type C Goniophotometer]]></title><link><![CDATA[https://15317383997.en.ec21.com/LM_79_Moving_Detector_Type--11812738_11812739.html]]></link><description><![CDATA[5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The measuring d]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Photocatalytic Xenon Lamp Light Source Photocatalysis Photocatalytic Visible Light UV Light]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Photocatalytic_Xenon_Lamp_Light_Source--11446837_11446862.html]]></link><description><![CDATA[at same time.
Technical Parameters
CEL-PF300-T6
CEL-PF300UV300-T6
Output light Power
10~20 Sun(1Sun=1000W/m2)
10~20 Sun
Spectral Output(nm)
300nm~2500nm（ozone free）
200nm~2500nm（ozone）
Beam D]]></description><pubDate><![CDATA[20240104]]></pubDate></item>
<item>
<title><![CDATA[High Quality Automatic Office Chair Casters Durability Test Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/High_Quality_Automatic_Office_Chair--11365007_11372368.html]]></link><description><![CDATA[500mm 
2. Load Weight: 225 LBS or specified 
3. Push-pull travel: 0 ~ 762mm
4. Test speed: 5-15CPM or specified 
5. Suitable type: chairs with universal wheel on all bases. 
6. Power supply: 1 wire, ]]></description><pubDate><![CDATA[20210423]]></pubDate></item>
<item>
<title><![CDATA[Computer Control YFTD300 Safety Valve Test Bench for Safety Valve Pressure Calibration and Seal Test]]></title><link><![CDATA[https://king3834656.en.ec21.com/Computer_Control_YFTD300_Safety_Valve--11745449_11747422.html]]></link><description><![CDATA[500 mm. After adjusting installation level, use concrete to fix the foot bolts. 2. Inject 30-40# hydraulic oil into the oil tank and the oil volume cannot be lower than the lowest limit of the oil le]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[100k - 10T Micro Signal Type Tester Resistance Capacitance and Inductance Tester]]></title><link><![CDATA[https://techmizetest.en.ec21.com/100k_10T_Micro_Signal_Type--11890824_11890825.html]]></link><description><![CDATA[500V(TH2683B)Insulation resistance test range: 100K-10TInsulation resistance, leakage current dual display24-bits, 4.3-inch and 4-wire touch LCD screenLCD resolution: 480*272Zero clearing functionCon]]></description><pubDate><![CDATA[20240119]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 Waterproof Testing Machine IPX12 Vertical Rain Drip Box]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC60529_Waterproof_Testing_Machine_IPX12--11405200_11418229.html]]></link><description><![CDATA[at an angle up to 15° from its normal position. Test duration: 10 minutes (2.5min in each of 4 fixed positions of tilt). Water equivalent to 3 mm/minute.
Features:
● For IPX1 and IPX2 testing
● ]]></description><pubDate><![CDATA[20210722]]></pubDate></item>
<item>
<title><![CDATA[Computer Controlled Electronic Universal Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/Computer_Controlled_Electronic_Universal_Testing--4048548_4096477.html]]></link><description><![CDATA[at Room Temperature
3) GB/T16491-1996 Electronic Universal Material Testing Machine
4) JJF1103-2003 Evaluation of Computer Data Acquisition System for Universal Testing Machine
5) GB/T16825-1997 Veri]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[DX-400 Gauging Length Instrument of Tensile Specimen]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/DX_400_Gauging_Length_Instrument--6690053_6690155.html]]></link><description><![CDATA[at different angles, dotting with the impact of elastic spring, the handle shaking one circle will make a straight line on the specimen, the space of 10 mm, a total of 40 points = 400 mm long.
Method]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[Pressure Composition Isotherm Equipment H-Sorb 2600PCT]]></title><link><![CDATA[https://goldapp.en.ec21.com/Pressure_Composition_Isotherm_Equipment_H--9600517_8490046.html]]></link><description><![CDATA[At present, there is tremendous interest in the development of innovative materials for the transition to renewable energy. The science of gas sorption has become particularly critical in the advance]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Ponovo T1000 Primary Injection Test Set for Different Types of Relays]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_T1000_Primary_Injection_Test--11744128_11737778.html]]></link><description><![CDATA[Ponovo T1000 Primary Injection Test Set
T1000 primary injection test set is the model featured with light weight and 2 minutes continuous output time at 1000Aac. This ideal primary injection test set]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Quick Thermal Conductivity Meter QTM-700/QTM-710]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Quick_Thermal_Conductivity_Meter_QTM--8755030_8755121.html]]></link><description><![CDATA[at the measurement of reference plate)Thin film measurementCompatibleNot compatibleOn-window display5.7 inch color LCDLanguageEnglish / Japanese / Chinese / KoreanExternal I/ORS232C : 2ch (Printer, D]]></description><pubDate><![CDATA[20190329]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Thickness Meter TM-8812 for Sale]]></title><link><![CDATA[https://105landtek.en.ec21.com/Ultrasonic_Thickness_Meter_TM_8812--9545005_11795523.html]]></link><description><![CDATA[500~9990 m/s
Lower Limit Steel Pipes: Φ15 x 2.0 mm Φ20 x 3.0 mm determined by transducer
Calibration Block: Included
Resolution: 0.1 mm (TM-8812C 0.01 mm)
Accuracy: ± (0.5%n + 0.1)
Automatic memor]]></description><pubDate><![CDATA[20230523]]></pubDate></item>

</channel>
</rss>