<title><![CDATA[Fluke 3540 FC KIT Three-Phase Power Monitor]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_3540_FC_KIT_Three--12045274_12045343.html]]></link><description><![CDATA[calculated on 25 harmonicsCalculated min/max values timesVoltage: Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)
Current: Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz)
Power: 200 msInterfacesUS]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Computer Controlled Automobile Seat Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/Computer_Controlled_Automobile_Seat_Testing--4048548_5133616.html]]></link><description><![CDATA[load
10kN
2
Precision class
Class 1
3
Measuring range of load
1%-100%FS (Class 1)
4
Relative error of indicating value
&amp;plusmn;1.0% (class 1) 
5
Resolution of test force
1/300000F.S (with constant re]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[ACP Electrical Current Transformer Test, CT/PT Analyzer]]></title><link><![CDATA[https://aijiezn.en.ec21.com/ACP_Electrical_Current_Transformer_Test--3533367_11343743.html]]></link><description><![CDATA[Calculation of Knee
Point Value 
3. Auto 5% and 10% error
curves, can measure ALF 
4. Transformer Ratio
Test 
5. Polarity 
6. Ratio difference
measurement 
7. Phase (angle difference)
measurement 
8.]]></description><pubDate><![CDATA[20210224]]></pubDate></item>
<item>
<title><![CDATA[Automatic Microcomputer Control Transformer Multi-functional Comprehensive Performance Test Bench]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/Automatic_Microcomputer_Control_Transformer_Multi--10586983_10716645.html]]></link><description><![CDATA[calculation of various parameters. 
Automatically correct voltage amplitude, waveform and temperature. 
The ratio of voltage to current can be set to directly display the measured value. 
The power-o]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Vehicle Test Bench Durability Test Car Speed/MileageTest Car Inspection Mot Testing Station Test OBD]]></title><link><![CDATA[https://leoscan.en.ec21.com/Vehicle_Test_Bench_Durability_Test--11841594_11841624.html]]></link><description><![CDATA[calculates. The linear velocity of the surface, and the data value is displayed. Test data can be saved, edited and generate report to print out.
The test bench is mainly composed of a host table, a ]]></description><pubDate><![CDATA[20230911]]></pubDate></item>
<item>
<title><![CDATA[GF1061 Portable CT PT Analyzer Is Mainly Used for Field or Lab Testing, It Can Finish the Measuremen]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/GF1061_Portable_CT_PT_Analyzer--10658146_10658147.html]]></link><description><![CDATA[Calculation of knee point value
7. Ratio error, phase error
7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee 
point value
8. Resistance test
9. Actual secondary]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[Computer Servo System Double-Column Tensile Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Computer_Servo_System_Double_Column--11372348_11372351.html]]></link><description><![CDATA[load protection and automatic stop function, it can automatically judge the sample fracture and stop the machine.11. Real-time measurement and display of test force, peak value, displacement, deforma]]></description><pubDate><![CDATA[20210423]]></pubDate></item>
<item>
<title><![CDATA[Coefficient of Friction Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Coefficient_of_Friction_Tester--11854816_11854821.html]]></link><description><![CDATA[value indicates a greater force requirement.
The coefficient of friction varies based on the specific materials involved. In the 
context of packaging film, the coefficient of friction refers to the ]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[value through focusing or get the current point coordinates through automatic focusing. You can also set whether auto focus is performed when running the user program The following figure shows the d]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[EHS Shore Durometer Hardness Tester Unit]]></title><link><![CDATA[https://mikrometry.en.ec21.com/EHS_Shore_Durometer_Hardness_Tester--11911431_11911440.html]]></link><description><![CDATA[calculate the hardness value with the average indentation depth.
MAX: To calculate the hardness value with the maximum indentation depth.