<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - cooling heating system]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/cooling_heating_system--2717/1/cooling heating system.html]]></link><item>
<title><![CDATA[YH701 Temperature and Humidity Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH701_Temperature_and_Humidity_Calibration--12022540_12022544.html]]></link><description><![CDATA[system: Heating is done using stainless steel heating tubes, which provide uniform heating and fast speed; Cooling is achieved through the use of high quality compressors, with a well-designed contro]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[Medium Force Shaker System (Air Cooled)]]></title><link><![CDATA[https://annie9311.en.ec21.com/Medium_Force_Shaker_System_Air--11982949_11982953.html]]></link><description><![CDATA[cooled electro dynamic shaker features a remote cooling blower with 100% suction air cooling to easily remove heat and noise from the test area, and a dual armature guidance system consisting of an u]]></description><pubDate><![CDATA[20240901]]></pubDate></item>
<item>
<title><![CDATA[Touch Screen Temperature Humidity Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Touch_Screen_Temperature_Humidity_Chamber--11164019_11164047.html]]></link><description><![CDATA[Heating rate
1...3℃/min.
Cooling rate
0.7...1.5℃/min.
Material 
Shell material 
Cold rolled sheet steel, spray plastics on surface
Internal material
Stainless steel
Thermal insulation material
Po]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[ISO16750-4 Clause 5.4.2 Ice Water Splash Test Chamber for Automotive Parts]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/ISO16750_4_Clause_5.4.2_Ice--11940576_11941038.html]]></link><description><![CDATA[Heating rate
RT +10℃~150℃ 
≤
45min
Splash water temperature
0℃~+4℃
Cooling rate
+25℃~2℃≤ 60min
Water flow
(3~4)L/3s
Test liquid 
De-ionized water or +3% Arizona fine dust
Injection ti]]></description><pubDate><![CDATA[20240522]]></pubDate></item>
<item>
<title><![CDATA[Xenon Lamp Weather Resistance Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Xenon_Lamp_Weather_Resistance_Test--11853101_11854260.html]]></link><description><![CDATA[system 
Refrigeration mode
Mechanical compression, two-stage refrigeration
Compressor 
International well-known brand
Cooling mode
Air cooling
Heater 
Nickel-chromium alloy heating wire
Temperature s]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/3kW_3.5kW_4kW_5kW_6kW--11807084_11807114.html]]></link><description><![CDATA[heat radiation and other air flow changes2: To test UPS,air conditioning fresh air system, lightning protection and grounding system, monitoring system, computer room comprehensive environment, cabin]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[SciAps X-555 Handheld XRF Analyzer]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/SciAps_X_555_Handheld_XRF--11834264_11834285.html]]></link><description><![CDATA[system allows for the greatest customization and data management capabilities.
‍Electric Vehicle and Strategic MetalsThe 55 kV operation, rather than the industry typical 50 kV, delivers higher per]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[GBPI Automatic Oxygen Transmission Rate Tester Y310 2.0]]></title><link><![CDATA[https://gbpitester.en.ec21.com/GBPI_Automatic_Oxygen_Transmission_Rate--11629254_11631112.html]]></link><description><![CDATA[heating and cooling; and no need of external accessories. Precision: 0.1℃. 
2)Humidity control: Dual gas flow method(dry gas and humid gas), with broad range, high precision (1%RH) and stable flow.]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Automatic Borderline Pumping Temperature of Engine Oil Tester (MRV) ASTM D3829 ASTM D4684]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Automatic_Borderline_Pumping_Temperature_of--11718430_11718462.html]]></link><description><![CDATA[Heating method: electric heating tube heating
7. 
Detection method: photocell detection
8. 
Control method: computer automatic control
9. 
Work unit: 5 units
10. 
Power of the whole machine: 1200KW
1]]></description><pubDate><![CDATA[20230201]]></pubDate></item>
<item>
<title><![CDATA[TN1058 Programmable Constant Temperature and Humidity Chamber]]></title><link><![CDATA[https://fulfilling.en.ec21.com/TN1058_Programmable_Constant_Temperature_and--5441143_9547151.html]]></link><description><![CDATA[Heating efficiency
＞3℃/min
Cooling efficiency
＞1℃/min，max 5℃/min
Temp accuracy
0.1 ℃
Temp fluctuation
&amp;plusmn;0.5℃
Temp uniformity
&amp;plusmn;2℃
Humidity fluctuation
&amp;plusmn;3﹪R.H
Hu]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Buy Air-cooled Two-Stage Piston Condensing Units]]></title><link><![CDATA[https://kendallcool.en.ec21.com/Buy_Air_cooled_Two_Stage--11754147_11827298.html]]></link><description><![CDATA[system that uses a two-stage compression process to cool and condense refrigerant. It is called &quot;air-cooled&quot; because it uses air as the heat transfer medium to cool the refrigerant.
2. What are the a]]></description><pubDate><![CDATA[20230731]]></pubDate></item>
<item>
<title><![CDATA[Solar Simulator Xenon Lamp Light Source Solar Cell IV Test]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Solar_Simulator_Xenon_Lamp_Light--11446867_11446868.html]]></link><description><![CDATA[cooling mode using fan air-cooled cycle cooling.
Model
CEL-S500-T5
Lamp type
Spherical xenon lamp (optional Osram imported from Germany)
Xenon lamp system
Three-dimensional adjustment, built-in lamp ]]></description><pubDate><![CDATA[20240104]]></pubDate></item>
<item>
<title><![CDATA[Gold Supplier Programmable Constant Temperature and Humidity Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Gold_Supplier_Programmable_Constant_Temperature--11372570_11372574.html]]></link><description><![CDATA[Heating rate: RT ~ 150ºC average 3ºC ~ 5ºC/min7. Cooling rate: RT ~ -20ºC average 1ºC/min8. Temperature and humidity controller: balance temperature and humidity control system9. Refrigeration s]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[Vertical Excitation Changeover Temperature Humidity Testing Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Vertical_Excitation_Changeover_Temperature_Humidity--11825687_11825688.html]]></link><description><![CDATA[system:Pretty appearance and convenient watering operation.2.Access to PC remote control and monitoring.3.Customization services.4.Observation window:Tempered glass with defroster, heating device, en]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Refrigerated Compressed Air Dryer]]></title><link><![CDATA[https://nailicomp.en.ec21.com/Refrigerated_Compressed_Air_Dryer--11374680_11824021.html]]></link><description><![CDATA[system. This heat exchange between ingoing and outgoing compressed air also reduces the temperature of the incoming compressed air, and as such reduces the required cooling capacity of the refrigeran]]></description><pubDate><![CDATA[20230724]]></pubDate></item>
<item>
<title><![CDATA[Gas Chromatography]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Gas_Chromatography--11907876_11907884.html]]></link><description><![CDATA[heating: 16th order
Total program time: 99999.9 minutes
Maximum heating rate: 120 ℃/min
Cooling method; Rear door opening+air-cooled or liquid nitrogen
Temperature range: 7 ℃~450 ℃ above room t]]></description><pubDate><![CDATA[20240301]]></pubDate></item>
<item>
<title><![CDATA[Climatic Testing Machine Manufacturer/Environmental Temperature Humidity Test Chamber]]></title><link><![CDATA[https://annie0423.en.ec21.com/Climatic_Testing_Machine_Manufacturer_Environmental--9938707_9938708.html]]></link><description><![CDATA[system of heating up, heating down, dehumidifying, and humidifying can be operated independently so as to reduce the cost of testing, extend the operating life of the machine and decrease the failure]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>