<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - detects frequency]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/detects_frequency--2717/1/detects frequency.html]]></link><item>
<title><![CDATA[Stress Cracking Tester]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Stress_Cracking_Tester--12024209_12034904.html]]></link><description><![CDATA[frequency of hand contact with lye.
The visible transparent cover with protective net, can safely observe the situation inside the testing stations in real time.
Electric discharge, high efficiency d]]></description><pubDate><![CDATA[20250106]]></pubDate></item>
<item>
<title><![CDATA[40m 20HZ 1mm Accuracy COM RXTX Serial Port TTL Digital Output Raspberry Pi Laser Distance Sensor]]></title><link><![CDATA[https://lasersensor2003.en.ec21.com/40m_20HZ_1mm_Accuracy_COM--11950652_11976847.html]]></link><description><![CDATA[detection, with 40m detection range and millimeter-level detection accuracy.
Meskernel provides high frequency ranging Sensor module,including but not limited to range, accuracy, baud rate, frequency]]></description><pubDate><![CDATA[20240729]]></pubDate></item>
<item>
<title><![CDATA[Multi Channel Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Multi_Channel_Ultrasonic_Flaw_Detector--11973711_11973720.html]]></link><description><![CDATA[Detection
or Ultrasonic Testing is a type of non-destructive Testing that employs high-frequency ultrasound waves to perform inspections and measurements. Ultrasonic inspection is often used to disco]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[NDJ-1C Hot Melt Adhesives Brookfield Viscosity Meter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_1C_Hot_Melt_Adhesives--11144324_11144465.html]]></link><description><![CDATA[frequency range
is wide, and the fluctuation of the power supply will not affect the 
measurement accuracy.
4. The
horizontal display device is on the front side of the viscometer. The 
adjustment le]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Maintenance Free Real-time Rebar Special Measuring Instrument GDC-L350-JX]]></title><link><![CDATA[https://measurementon.en.ec21.com/Maintenance_Free_Real_time_Rebar--11962128_11962131.html]]></link><description><![CDATA[Detection type: rebar
Measurement principle: laser scanning method;
Measurement method: rotary measurement;
Measurement
frequency: 1600;
Rotation speed: ≥30 rpm;
Installation method: fixed or mobil]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[2 Axis 2 Frame POD Multiple Spectral Electro Optic Camera Sensor 4.5kg]]></title><link><![CDATA[https://leadir.en.ec21.com/2_Axis_2_Frame_POD--11958808_11958803.html]]></link><description><![CDATA[Frequency
1Hz
Environmental Adaptability
Operating Temperature
−20°c~+50°c
Storage Temperature
-30°c~+55°c
Humidity
(95±3)%(±40°c)
Application
Search and Rescue
Weeklywarning
Perimeter Secur]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[ST-6600 Plug Skin High Voltage Tester]]></title><link><![CDATA[https://satatec.en.ec21.com/ST_6600_Plug_Skin_High--7687564_7687872.html]]></link><description><![CDATA[ST-6600 Plug Skin High Voltage Tester 
Used range: Applied to detect the conductor of power cord plug whether exposed 
Principle: Principle of using high-frequency and high-voltage spark discharge te]]></description><pubDate><![CDATA[20240614]]></pubDate></item>
<item>
<title><![CDATA[Digital Infrared Radiometer]]></title><link><![CDATA[https://gatherstar.en.ec21.com/Digital_Infrared_Radiometer--11943208_11943246.html]]></link><description><![CDATA[frequency 1KHz)
Output interface 
RS-422 (Maximum transmission distance 200 meters)
Power Supply 
220VAC/24VDC
Temperature 
-40℃ 
~ +50
℃
Dimension 
279（L）* 202（H）*274（D）---RLK601、R]]></description><pubDate><![CDATA[20240527]]></pubDate></item>
<item>
<title><![CDATA[Master Meter Gas Flow Calibration System]]></title><link><![CDATA[https://tnmacalibration.en.ec21.com/Master_Meter_Gas_Flow_Calibration--11926262_11926263.html]]></link><description><![CDATA[frequencies), which can lead to inconsistent triggering times, an advanced dual time-base technique has been adopted to correct the detection time for both the standard meter and the meter under test]]></description><pubDate><![CDATA[20240417]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Wire Harnesses/Cables Testing Bench Top(Table) for Automotive]]></title><link><![CDATA[https://shcleanknow4567.en.ec21.com/High_Voltage_Wire_Harnesses_Cables--11923899_11923921.html]]></link><description><![CDATA[Detection time
10µs approx
Precision Resistance Test 
Continuity 
Setting Range 0.1-500K
Resistance
0.1-100KΩ; ±3%±0.1
100K-1MΩ; ±5%
0.01-75Ω; ±3%±0.01
ICR Test 
Frequency
50Hz-1MHz optional]]></description><pubDate><![CDATA[20240412]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[frequency, temperatureRate4 steps/secondTrip detectContinuity or voltage (continuity detection not available when sourcing current)Loop power functionVoltage Selectable, 26 VAccuracy10%, 18 V minimum]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Fully Automatic Insertion and Extraction Force Tester]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Fully_Automatic_Insertion_and_Extraction--11683816_11853603.html]]></link><description><![CDATA[Product DescriptionTechnical specifications：
1. Maximum test force: 1000N, 500N, 200N, 10N (optional);
2. The sampling frequency is 100Hz;
3. Accurate measurement: Class 0.5;
4. Minimum resolution:]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Temperature Humidity Standard Environment Experiment Calibration Chamber Cabinet]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Temperature_Humidity_Standard_Environment_Experiment--11689458_11689464.html]]></link><description><![CDATA[frequency conversion speed regulation control, through touch screen, set fan speed;
* Multiple protection alarms: constant temperature tank overheating protection, liquid level alarm; rehydration tan]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[New Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_Nortec_600D_Eddy--11801594_11801595.html]]></link><description><![CDATA[frequency capacity.Automatic internal balancing (BNC connector).Up to two real-time readings.True automatic mixing.Storage capacity of up to 500 files (program and data).On-board file preview.Portabl]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[EMI Test Receiver]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/EMI_Test_Receiver--11882688_11882698.html]]></link><description><![CDATA[Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA) • Frequency stability: 1×10^-6• Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz• Test ]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Liquid Chromatograph]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Liquid_Chromatograph--11907876_11909750.html]]></link><description><![CDATA[frequency ensure low noise, low drift, and ultra-high sensitivity.
The VI2010 workstation meets various regulatory requirements.
Reliable results - meeting customer&apos;s accurate requirements for result]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[EMI Receiver System]]></title><link><![CDATA[https://15317383997.en.ec21.com/EMI_Receiver_System--11812738_11812765.html]]></link><description><![CDATA[Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA) • Frequency stability: 1×10^-6• Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz• Test ]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Gelbo Flex Durability Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Gelbo_Flex_Durability_Tester--11854816_11854825.html]]></link><description><![CDATA[output.
Main Parameter
Flex Frequency 45 /minute
Flex Angle 440° (90 mm) or 400° (80 mm)
Capacity 2.5 N.m
Horizontal Stroke 155 mm or 80 mm
Stations 4
Sample Size 280 mm x 200 mm
Power 110~220V
]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[Automatic Safety Test System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Automatic_Safety_Test_System--9657760_11802784.html]]></link><description><![CDATA[frequency; Electric safety wall detecting feature• The LS9955 can do test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current (LLC) and Ground Resistance (GR)• The LS9956 c]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[DC Motor Armature Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/DC_Motor_Armature_Testing_Equipment--11085938_11085990.html]]></link><description><![CDATA[display value+2.5% measuring range+3words
Waveforms limited value
Minimum difference 0.1%
(waveform difference)
impulse internal setting
Available 
Sample frequency
20/40MHz（self-adjustable)
]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Vibration Meter VM-6360 for Sale]]></title><link><![CDATA[https://105landtek.en.ec21.com/Vibration_Meter_VM_6360_for--9545665_9545690.html]]></link><description><![CDATA[detect out-of-balance, misalignment and other mechanical faults in rotating machines.
* Wide frequency range (10Hz~10kHz) in acceleration mode.
Details:
Sensor
Piezoelectric Transducer
Measuring Rang]]></description><pubDate><![CDATA[20230731]]></pubDate></item>
<item>
<title><![CDATA[ZXUD - 40 Digital Truecolor Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ndtchina.en.ec21.com/ZXUD_40_Digital_Truecolor_Ultrasonic--6581053_6161468.html]]></link><description><![CDATA[detector match up.
Optimizing pulse repetition frequency control, good dynamic effect of echo pulse, no lag, meeting the demand of different crystal grains and detection distances.
Intelligent automa]]></description><pubDate><![CDATA[20140520]]></pubDate></item>

</channel>
</rss>