<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - filter value]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/filter_value--2717/1/filter value.html]]></link><item>
<title><![CDATA[YH800C Portable Fully Automatic Pressure Calibrator]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800C_Portable_Fully_Automatic_Pressure--12022422_12033066.html]]></link><description><![CDATA[value digit display: 4, 5, or 6 digits are optional;
◆ Task management function, capable of downloading verification tasks and uploading stored data;
◆ Quick storage, with a storage capacity of o]]></description><pubDate><![CDATA[20241225]]></pubDate></item>
<item>
<title><![CDATA[Emcee Model 1140 Micro-Separometer]]></title><link><![CDATA[https://xmjielian.en.ec21.com/Emcee_Model_1140_Micro_Separometer--11982130_11982132.html]]></link><description><![CDATA[filter at a programmed rate and a portion is collected in the retained vial. The vial is replaced in the turbidimeter and the water separation characteristic of the fuel is rated.The value obtained i]]></description><pubDate><![CDATA[20240808]]></pubDate></item>
<item>
<title><![CDATA[Bruker Tracer 5i Handheld XRF Spectrometer]]></title><link><![CDATA[https://thexrfstore.en.ec21.com/Bruker_Tracer_5i_Handheld_XRF--11822199_11822200.html]]></link><description><![CDATA[TRACER 5 is the high value in-situ pXRF performer synchronizing power, function, precision and accuracy for dynamic, field capable laboratory-like elemental analysis.Detector window: 8 μm BerylliumD]]></description><pubDate><![CDATA[20230720]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[value.
Over voltage protection: Over voltage value continuously adjustable from 0 to 110% rated value, auto-shut down when output voltage exceeds the over voltage set point
Short protection: Withstan]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Furniture Mechanics Comprehensive Test Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Hot_Sale_Furniture_Mechanics_Comprehensive--11365007_11365011.html]]></link><description><![CDATA[Model NumberLT-JJ10-ALoad capacity200kg, 500kg (force value can be set)Load Accuracy3/10000 Test accuracystatic: ± 2%; dynamic force: ± 3% Displacement and travel0-300mm or 0-500mm are optional.Tim]]></description><pubDate><![CDATA[20210416]]></pubDate></item>
<item>
<title><![CDATA[Computer Control YFTD300 Safety Valve Test Bench for Safety Valve Pressure Calibration and Seal Test]]></title><link><![CDATA[https://king3834656.en.ec21.com/Computer_Control_YFTD300_Safety_Valve--11745449_11747422.html]]></link><description><![CDATA[value can be captured to print out the testing monitoring graph, which can be used as technical document archive. 5. &quot;Safety door&quot; device is advised to make sure safety during air seal test process. ]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[WQLB Sonic Nozzle Gas Flow Standard Facility]]></title><link><![CDATA[https://royreal.en.ec21.com/WQLB_Sonic_Nozzle_Gas_Flow--11907986_11909431.html]]></link><description><![CDATA[values.4. The small-caliber flowmeter rotates and switches clamping rapidly, no need to replace the measuring section, saving space.5. Pneumatic clamping table, easy and efficient.6. The computer int]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/Used_Olympus_Nortec_600D_Eddy--11801594_11801596.html]]></link><description><![CDATA[values over 62%. Meets or exceeds BAC 5651 specifications.
Non-conductive coating thicknessCan measure non-conductive coating thickness from 0 mm to 0.648 mm. Accuracy of 0.025 mm (±0.001 in.) over ]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Salt Spray Test | Salt Spray Test Chamber]]></title><link><![CDATA[https://15317383997.en.ec21.com/Salt_Spray_Test_Salt_Spray--11812738_11858086.html]]></link><description><![CDATA[value cannot be lower than the current ambient temperature); Saturated barrel temperature: +40°C~+63°C;• Brine temperature: preheated by laboratory temperature; Temperature uniformity: ≤ ±2°C]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Gas Pycnometer Analyzer G-DenPyc 2900]]></title><link><![CDATA[https://goldapp.en.ec21.com/Gas_Pycnometer_Analyzer_G_DenPyc--9431275_9269540.html]]></link><description><![CDATA[value for some fixed-temperature-required samples
Control System: programmable logic controller (PLC) system obtains high integration and strong anti-interference, software operated fully automated a]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Surface Roughness Tester SRT-6200]]></title><link><![CDATA[https://105landtek.en.ec21.com/Hot_Sale_Surface_Roughness_Tester--9545708_11803265.html]]></link><description><![CDATA[value
Not more than 6%
Sensor
Test Principle
Inductance type
Radius of Probe Pin
10 um
Material of Probe Pin
Diamond
Measurement Force of Probe
16 mN（1.6 gf）
Probe Angle
90°
Vertical Radius of G]]></description><pubDate><![CDATA[20230607]]></pubDate></item>

</channel>
</rss>