<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - fixed temperature]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/fixed_temperature--2717/1/fixed temperature.html]]></link><item>
<title><![CDATA[Hot Rolled Bar Outer Diameter Measuring Instrument GDC-J2400-JX]]></title><link><![CDATA[https://measurementon.en.ec21.com/Hot_Rolled_Bar_Outer_Diameter--11962128_11962129.html]]></link><description><![CDATA[temperature: ≤1200℃
Measuring range: 5-360mm
Allowable deviation: ≤±0.06
Installation location: after intermediate rolling mill or finishing rolling mill
Diameter measuring equipment
is used t]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[Extra Large Measuring Machine Atlas Series UCC Pantec Controller AC-Dmis for Large Workpieces]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Extra_Large_Measuring_Machine_Atlas--11944568_11944833.html]]></link><description><![CDATA[fixed and the other end free, facilitating temperature correction;
The driving system adopts high-performance servo motors from internationally renowned brands. The X and Z axes adopt synchronous too]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 IPX1-4 Comprehensive Waterproof Test Chamber Integrated with Drip Box and Oscillating Tubes]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60529_IPX1_4_Comprehensive_Waterproof--11940576_11940977.html]]></link><description><![CDATA[temperature), ≤85% (R.H.), 86kPa~106kPa (pressure)
Accessories
Water filter*2, test needle*100, 3-core cable*1 (6m), user manual in English
Water source
1).The user is required to configure a water]]></description><pubDate><![CDATA[20240522]]></pubDate></item>
<item>
<title><![CDATA[KRD101 Custom Printed Packaging Cardboard Compression Testing Machine]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD101_Custom_Printed_Packaging_Cardboard--11098426_11099497.html]]></link><description><![CDATA[/ min)
0 ~120 (can be set arbitrarily)
Foundation Requirements
Smooth cement floor
Working Environment
Temperature range 0 ~ 40℃, humidity≤80% (non-condensing)
Power
3-phase AC 380V±10％ 50Hz
]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[LM-79 Moving Detector Goniophotometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/LM_79_Moving_Detector_Goniophotometer--11802221_11802222.html]]></link><description><![CDATA[temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L• LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illu]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Dual Lens Borescope]]></title><link><![CDATA[https://teximinternational.en.ec21.com/Dual_Lens_Borescope--6335069_6482834.html]]></link><description><![CDATA[Temperature
-20 &amp;ordm; to 60 &amp;ordm; C (-4&amp;ordm; to 140&amp;ordm; F)
Storage Temperatur
-20 &amp;ordm; to 60 &amp;ordm; C (-4&amp;ordm; to 140&amp;ordm; F)
Relative Humidity
95% max
Waterproof
IP67(Insertion tube and tip]]></description><pubDate><![CDATA[20160715]]></pubDate></item>
<item>
<title><![CDATA[HZC-3980 High Voltage CB Tester Circuit Breaker Dynamic Characteristics Analyzer]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/HZC_3980_High_Voltage_CB--10544358_10544719.html]]></link><description><![CDATA[Temperature
-10~40℃
Humidity
&lt;80%RH
Safety Performance
Insulation resistance
&gt;2MΩ
Dielectric strength
Power to chassis frequency voltage withstands 1.5KV, 1 min, no flashover and arcing.
Basic par]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[JB-500B Impact Testing Machine]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/JB_500B_Impact_Testing_Machine--6651349_6678633.html]]></link><description><![CDATA[temperature range is 10-35 ℃; 
2. Relative humidity is less than 85％; 
3. Non-corrosive media surrounding environment;
4. Installed in the thickness of more than 150mm of concrete foundations or ]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[Ozone Test Chamber,Ozone Colorfastness Tester AATCC 109 ISO 105 G03 ASTM D1149]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Ozone_Test_Chamber_Ozone_Colorfastness--5441143_9547155.html]]></link><description><![CDATA[temperature resistant silica gel seal to ensure that the test area is airtighted;
6.Bottom of the machine with high-quality universal running wheels and fixed foot cups;
7.Observation window with Mul]]></description><pubDate><![CDATA[20200216]]></pubDate></item>
<item>
<title><![CDATA[Gas Pycnometer Analyzer G-DenPyc 2900]]></title><link><![CDATA[https://goldapp.en.ec21.com/Gas_Pycnometer_Analyzer_G_DenPyc--9431275_9269540.html]]></link><description><![CDATA[temperature(25 C) which can restrain transducer reading’s temperature drift and keep system temperature uniformity; System can maintain temperature at a fixed value for some fixed-temperature-requi]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[VSM Vibrating Sample Magnetometer M-H Curve Hysteresis Graph Test System Magnetic Properties]]></title><link><![CDATA[https://jackietsui.en.ec21.com/VSM_Vibrating_Sample_Magnetometer_M--8508233_11795131.html]]></link><description><![CDATA[Temperature range: from -196℃ to 900℃.
6. The magnetic Pole pitch for a fixed spacing is 40 mm, and the pole face diameter is 60 mm.
7. Magnetic field: supplied by the electromagnet, from 0 to 3.]]></description><pubDate><![CDATA[20230522]]></pubDate></item>
<item>
<title><![CDATA[LITE800 Industrial SLA 3D Printer]]></title><link><![CDATA[https://uniontech3d.en.ec21.com/LITE800_Industrial_SLA_3D_Printer--11706631_11807017.html]]></link><description><![CDATA[Temperature Range
72–79 °F (22–26 °C)
Maximum Change Rate
1 °C/hour
Relative Humidity
&lt; 40%
Machine Size (W x D x H)
1555 × 1445 × 2215 mm
Machine Weight
1050 kg
Initial Resin Weight
560 kg
]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[New NDT Systems Raptor Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New_NDT_Systems_Raptor_Flaw--11801594_11801615.html]]></link><description><![CDATA[Temperature14 °F to 122 °F (-10 °C to 50 °C)
Case ConstructionAluminum body, rubber end caps
Connector typeDual BNCKeypadKeypad constructionTactile membrane feedback keys, wheel controlTransducer]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[LM-79 Moving Detector Type C Goniophotometer]]></title><link><![CDATA[https://15317383997.en.ec21.com/LM_79_Moving_Detector_Type--11812738_11812739.html]]></link><description><![CDATA[temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L• LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illu]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Dissolution Tester Device]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Dissolution_Tester_Device--11600339_11853671.html]]></link><description><![CDATA[temperature switch.• 1/3B high-precision Pt1000 temperature sensor with fast response and high precision. ※• Equipped with an electric, independent multi-channel, automatic dosing system, which]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[High Performance FTIR Fourier Transform Infrared Spectrometer]]></title><link><![CDATA[https://gbpitester.en.ec21.com/High_Performance_FTIR_Fourier_Transform--11631034_11631045.html]]></link><description><![CDATA[Temperature control accuracyBetter than 15000:1/30000:1，（4cm-1，one-minute scan）ResolutionBetter than 1.0cm-1Beam splitterPotassium bromide substrate plate germaniumReceiverImported high signa]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[YFT-D300 Pressure Relief Valve Test Bench for Safety Valve Pressure Calibration and Sealing Test]]></title><link><![CDATA[https://king3834656.en.ec21.com/YFT_D300_Pressure_Relief_Valve--11745449_11747554.html]]></link><description><![CDATA[temperature, prolonging life of the test bench and saving energy.7. hydraulic clamping has safety interlock with air pressure discharge8. functions can be chosen as the following: safety door and tou]]></description><pubDate><![CDATA[20230330]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 Waterproof Testing Machine IPX12 Vertical Rain Drip Box]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC60529_Waterproof_Testing_Machine_IPX12--11405200_11418229.html]]></link><description><![CDATA[temperature), ≤85% (R.H.), 86kPa~106kPa (pressure)
Accessories
Water filter*2, test needle*100, brass needle holder*20, 3-core cable*1 (3m)
Water source
1). The user is required to configure a wate]]></description><pubDate><![CDATA[20210722]]></pubDate></item>
<item>
<title><![CDATA[Anti-yellowing Aging Test Chamber]]></title><link><![CDATA[https://annie0423.en.ec21.com/Anti_yellowing_Aging_Test_Chamber--9938796_9938808.html]]></link><description><![CDATA[temperature sensor and adopts black board temperature meter to control heating so as to 
ensure more stable temperature. 
The radiometer probe is fixed so as to avoid the frequent installation and di]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>