<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - for sensitive]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/for_sensitive--2717/1/for sensitive.html]]></link><item>
<title><![CDATA[Flir C5 - Compact Thermal Camera with Wi-Fi]]></title><link><![CDATA[https://toolshed.en.ec21.com/Flir_C5_Compact_Thermal_Camera--12045274_12045319.html]]></link><description><![CDATA[for dark, hard to reach areas
Manufacturer SpecsIR sensor160 × 120 (19,200 pixels)Thermal sensitivity/NETD&lt;70 mKField of view (FOV)54° × 42°Minimum focus distanceThermal: 0.1 m (3.94 in)MSX: 0.3 ]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO 60 Hz, 640 X 480 High-Performance IR Thermal Camera]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_TI480_PRO_60_Hz--11561118_11932301.html]]></link><description><![CDATA[for one-handed use
Thermal sensitivity (NETD): ? 0.05 �C at 30 �C target temp (50 mK)
Temperature measurement range (not calibrated below -10 �C): ?-10 �C to +1000 �C (14 �F to 1832 �F)]]></description><pubDate><![CDATA[20250129]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Weld Scanning-spot Weld Testing]]></title><link><![CDATA[https://shnde.en.ec21.com/Ultrasonic_Weld_Scanning_spot_Weld--11943775_12036764.html]]></link><description><![CDATA[for real-time monitoring.
RSWA F2: Building on the performance of the F1, the RSWA F2 offers enhanced capabilities, with a wider detection range and greater sensitivity. It can handle larger componen]]></description><pubDate><![CDATA[20250114]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[for enhanced accuracy and clarityPremium in-field viewing experience with the 5.7-inch responsive LCD touchscreen – 150% more viewing area than a standard 3.5-inch screenEasily maneuver over, under]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[for one-handed useYesThermal sensitivity (NETD)**≤ 0.05 °C at 30 °C target temp (50 mK)Level and spanSmooth auto and manual scalingFast auto toggle between manual and auto modesYesFast auto-resca]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[Smoke Detector]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke_Detector--11987076_11987700.html]]></link><description><![CDATA[Equipment
Function ： 
The
smoke heat detector test tunnel was designed for sensitivity test of Smoke alarms/detectors
according to GB 20517、GB4715、EN 14604、EN 54-7 and
ISO standards. It consi]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Dissolved Ozone Meter Intelligent Online Water Ozone Analyzer Tester Sanitizer Ozone]]></title><link><![CDATA[https://nobotech.en.ec21.com/Dissolved_Ozone_Meter_Intelligent_Online--11181496_11182362.html]]></link><description><![CDATA[for continuous detection and control of amounts of ozone in liquid.
DOZ-7600 is a high-end online ozone detector, it has two 4-20MA outputs, with automatic cleaning electrode device output, maintenan]]></description><pubDate><![CDATA[20240929]]></pubDate></item>
<item>
<title><![CDATA[UTOCO Handheld Laser Detector with Tdlas for Natural Gas Distribution Pipeline]]></title><link><![CDATA[https://utoco.en.ec21.com/UTOCO_Handheld_Laser_Detector_with--12010082_12010092.html]]></link><description><![CDATA[for inspectors to access. This device accurately and swiftly locates leakage points and sources, enhancing work efficiency and reducing labor demands.
The TDLAS sensor offers high sensitivity, rapid ]]></description><pubDate><![CDATA[20240926]]></pubDate></item>
<item>
<title><![CDATA[EMCEE Model 1154 Precision Conductivity Meter]]></title><link><![CDATA[https://xmjielian.en.ec21.com/EMCEE_Model_1154_Precision_Conductivity--11982130_11982350.html]]></link><description><![CDATA[sensitive dc ammeter in the Console and a dc voltage is applied between the two electrodes. Due to the physical geometry of the Cell, the Cell constant is stable and calculable. Thus, the resultant p]]></description><pubDate><![CDATA[20240813]]></pubDate></item>
<item>
<title><![CDATA[Geiger Muller Detector]]></title><link><![CDATA[https://radsafetech.en.ec21.com/Geiger_Muller_Detector--11848452_11979475.html]]></link><description><![CDATA[for general-purpose radiation detection.
Pancake GM Tubes
Pancake tubes have a larger surface area, making them more sensitive to alpha and beta radiation. They are ideal for surface contamination mo]]></description><pubDate><![CDATA[20240802]]></pubDate></item>
<item>
<title><![CDATA[Multi Channel Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Multi_Channel_Ultrasonic_Flaw_Detector--11973711_11973720.html]]></link><description><![CDATA[for applications requiring higher frequencies, and a tunable square wave pulser to optimize penetration on thick or highly attenuating materials.
The instrument can be widely used in locating and siz]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[ST-6600 Plug Skin High Voltage Tester]]></title><link><![CDATA[https://satatec.en.ec21.com/ST_6600_Plug_Skin_High--7687564_7687872.html]]></link><description><![CDATA[to find the gas bubble and exposed copper wire.
Features:
Output sensitivity can be adjust continually
Alarm functions of light and voice for NG sample
Test fixture is simple and easy to change
]]></description><pubDate><![CDATA[20240614]]></pubDate></item>
<item>
<title><![CDATA[High Accuracy 1.5um 1.5+L/300 Above Bridge CMM Coordinate Measuring Machine Legend Series]]></title><link><![CDATA[https://aehcmm.en.ec21.com/High_Accuracy_1.5um_1.5_L--11944568_11944817.html]]></link><description><![CDATA[for high accuracy ,high efficiency.It specially applied in aerospace,military,automotive and etc
Main Features
Granite materials that are not sensitive to temperature are selected for all three axes,]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Digital Infrared Radiometer]]></title><link><![CDATA[https://gatherstar.en.ec21.com/Digital_Infrared_Radiometer--11943208_11943246.html]]></link><description><![CDATA[APPLICATION： 
Infrared radiation characteristics for 
l 
Aircraft engine
l 
Missile engine
l 
Infrared decoy
l 
Infrared target
l 
Initiating explosive device
l 
Industrial radiation sources
Model ]]></description><pubDate><![CDATA[20240527]]></pubDate></item>
<item>
<title><![CDATA[Gravimetric Water Meter Test Bench]]></title><link><![CDATA[https://tnmacalibration.en.ec21.com/Gravimetric_Water_Meter_Test_Bench--11926262_11934189.html]]></link><description><![CDATA[sensitive pointer of the water meter, significantly reducing the amount of water used for detecting the Q1/Q2 flow points, thereby greatly improving the testing efficiency.
Verification Function: The]]></description><pubDate><![CDATA[20240509]]></pubDate></item>
<item>
<title><![CDATA[ASTM F1140 Package Burst Tester Leak and Seal Strength Testing Instruments ASTM F2054]]></title><link><![CDATA[https://celtec.en.ec21.com/ASTM_F1140_Package_Burst_Tester--9267520_9267508.html]]></link><description><![CDATA[LSST-01 Leak and Seal Strength Tester
Description:
Introducing the LSST-01 Leak and Seal Strength Tester, a pivotal instrument for assessing the integrity of packaging materials, tailored for diverse]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[Liquid Chromatograph]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/Liquid_Chromatograph--11907876_11909750.html]]></link><description><![CDATA[for wavelength adjustment, and dual high-speed sampling frequency ensure low noise, low drift, and ultra-high sensitivity.
The VI2010 workstation meets various regulatory requirements.
Reliable resul]]></description><pubDate><![CDATA[20240308]]></pubDate></item>
<item>
<title><![CDATA[N5234B PNA-L Network Analyzers]]></title><link><![CDATA[https://dgqihang.en.ec21.com/N5234B_PNA_L_Network_Analyzers--11851310_11851312.html]]></link><description><![CDATA[sensitive applications.
Get the world’s best price-to-performance ratio for microwave manufacturing.
Configure an economical solution for signal-integrity measurements and materials characterizatio]]></description><pubDate><![CDATA[20231007]]></pubDate></item>
<item>
<title><![CDATA[SENSIT SPOD VOC Emissions and Air Pollutant Monitoring System]]></title><link><![CDATA[https://diamondscientific.en.ec21.com/SENSIT_SPOD_VOC_Emissions_and--11521359_11854341.html]]></link><description><![CDATA[SENSIT® SPOD features solar charging and global cellular integration for remote operation. SENSIT® SPOD includes an Ultrasonic Anemometer for wind speed, direction, temperature, humidity, and press]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[SciAps X-555 Handheld XRF Analyzer]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/SciAps_X_555_Handheld_XRF--11834264_11834285.html]]></link><description><![CDATA[sensitivity — 2x better analysis of cadmium detection than any other XRF! Packs the industry’s most powerful X-ray tube for superior limits of detection—especially for cadmium, silver, tin, ant]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[Flexible Rogowski Coils]]></title><link><![CDATA[https://xinghuodianzi.en.ec21.com/Flexible_Rogowski_Coils--11857606_11857607.html]]></link><description><![CDATA[sensitivity, accuracy, linearity, minimum phase shift.Suitable for harsh operating environments (temperature, humidity, EMI).Current Range: 100A to 100kAAccuracy: &lt; 1%Phase Shift: &lt; 1 degrees at 50/6]]></description><pubDate><![CDATA[20231031]]></pubDate></item>
<item>
<title><![CDATA[High Performance FTIR Fourier Transform Infrared Spectrometer]]></title><link><![CDATA[https://gbpitester.en.ec21.com/High_Performance_FTIR_Fourier_Transform--11631034_11631045.html]]></link><description><![CDATA[for the samples, high resolution, 
low noise, excellent accuracy of wave number, can satisfy the application for 
research of customer, is a powerful tool in the field of medicine, environmental 
pro]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Borderline Pumping Temperature of Engine Oil Tester]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Borderline_Pumping_Temperature_of_Engine--11718430_11856915.html]]></link><description><![CDATA[for users to flexibly control the test process
6. 
Improved pulley assembly, enhanced pulley stability and sensitivity, photoelectric sensor test;
7. 
5 rotors can be detected at the same time, diver]]></description><pubDate><![CDATA[20231020]]></pubDate></item>
<item>
<title><![CDATA[EMI Test Receiver]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/EMI_Test_Receiver--11882688_11882698.html]]></link><description><![CDATA[EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is made of full closure structure and strong electro-conductib]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[AS-2011 Micron Laser Particle Size Analyzer 0.1-500um]]></title><link><![CDATA[https://aimsizer.en.ec21.com/AS_2011_Micron_Laser_Particle--4628668_4628669.html]]></link><description><![CDATA[sensitive photocells and full-course Mie Scattering Theory executed by excellent and innovative algorism. It is the most reliable, accurate and cost-effective micron laser particle size analyzer Aims]]></description><pubDate><![CDATA[20100926]]></pubDate></item>
<item>
<title><![CDATA[SAW Pipe Real-time Inspection System]]></title><link><![CDATA[https://ndtchina.en.ec21.com/SAW_Pipe_Real_time_Inspection--6581053_6161342.html]]></link><description><![CDATA[Industrial RTR System
SAW Pipe Real-time Inspection System
This system is specified for the online inspection of spiral/longitudinal SAW pipe (max diameter 2400mm, max length 16.5m).
System configura]]></description><pubDate><![CDATA[20140520]]></pubDate></item>
<item>
<title><![CDATA[V-Sorb 2800TP Surface Area and Porosimtery Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/V_Sorb_2800TP_Surface_Area--7277224_7277091.html]]></link><description><![CDATA[for specific surface area, pore volume and pore size related parameters, especially micropore testing. It equipped with our multi pioneered technologies these make its performance much better, height]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Tensile Tester]]></title><link><![CDATA[https://pnshar.en.ec21.com/Tensile_Tester--6815941_6804873.html]]></link><description><![CDATA[sensitive adhesive tape 7. Fracture strength and elongation of synthetic fiber 8. Easy slide degree of pulling chain. APPLICATIONS Paper, Newsprint, Cartons board, Packaging Papers, Liner, Medium, Fo]]></description><pubDate><![CDATA[20120619]]></pubDate></item>
<item>
<title><![CDATA[Ponovo PNS630 Hand-held IEC61850 Network Analyzer for Digital Substation]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_PNS630_Hand_held_IEC61850--11744131_7404130.html]]></link><description><![CDATA[Description of Ponovo PNS630 Hand-held IEC61850 Network Analyzer for Digital Substation
With the development of power system, more and more digital substation based on IEC61850 has been built in the ]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[High Precision Spectroradiometer Integrating Sphere System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High_Precision_Spectroradiometer_Integrating_Sphere--9657760_11802275.html]]></link><description><![CDATA[LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED’s quality should be tested by checking its photometric, colorimetr]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[for some special conditions that sensitive to EMC. And by its matured and perfect filtering circuit, it has super low ripple and very good output precision; also it has complete protection functions
]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[VSM Vibrating Sample Magnetometer M-H Curve Hysteresis Graph Test System Magnetic Properties]]></title><link><![CDATA[https://jackietsui.en.ec21.com/VSM_Vibrating_Sample_Magnetometer_M--8508233_11795131.html]]></link><description><![CDATA[Sensitivity：5×10⁻⁵emu).
2. Relative accuracy (30emu ): better than ±1%
3. Repeatability (30emu): better than ±1%.
4. Stability (30emu): Preheating 24 hours, 24 hours of continuous work super]]></description><pubDate><![CDATA[20230522]]></pubDate></item>
<item>
<title><![CDATA[Horizontal Type Valve Pressure Test Bench]]></title><link><![CDATA[https://valvegrindingmachine.en.ec21.com/Horizontal_Type_Valve_Pressure_Test--10886107_10886118.html]]></link><description><![CDATA[for shell test, sealing test (low pressure sealing test and high pressure sealing test) and upper seal test (ISO5208) for GB4981
Features: simple operation, safe and reliable, sensitive test.
1.Produ]]></description><pubDate><![CDATA[20220509]]></pubDate></item>
<item>
<title><![CDATA[Pocket Penetrometer Kit for Testing Compressive Soil Strength for Civil]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/Pocket_Penetrometer_Kit_for_Testing--10976325_10976477.html]]></link><description><![CDATA[for use in very sensitive soils. 
A pocket penetrometer is required by OSHA on all excavation jobs, and it can help protect you from costly lawsuits and construction delays.
Usage Instructions: 
The ]]></description><pubDate><![CDATA[20230530]]></pubDate></item>
<item>
<title><![CDATA[Humidity &amp; Temperature Sensor Probe(RS485, Voltage, Current Out)]]></title><link><![CDATA[https://sentrionkorea.en.ec21.com/Humidity_Temperature_Sensor_Probe_RS485--11545348_11353797.html]]></link><description><![CDATA[Sentrion Humidity and Temperature Sensor Probe
IP67 Waterproof Stainless Steel Plastic Housing, RS485, Voltage or Current Output
Features
■ High sensitive temperature and humidity sensor probe 
■]]></description><pubDate><![CDATA[20220401]]></pubDate></item>
<item>
<title><![CDATA[ANDOR DV435-BV Series CCD Camera W/Software]]></title><link><![CDATA[https://gridatama123.en.ec21.com/ANDOR_DV435_BV_Series_CCD--11812295_11812303.html]]></link><description><![CDATA[sensitivity• 
Min operating temp of -70°C with TE Cooling: Negligible dark current 
without the aggravation or safety concerns associated with LN2• UltraVac™: Critical for sustained vacuum int]]></description><pubDate><![CDATA[20230627]]></pubDate></item>
<item>
<title><![CDATA[TST-01 Tensile Tester]]></title><link><![CDATA[https://materialstests.en.ec21.com/TST_01_Tensile_Tester--11896648_11896653.html]]></link><description><![CDATA[sensitive adhesives, medical plasters, release paper, protective film, combined caps, metal foils, diaphragms, back panels, non-woven fabrics, rubber, paper, and fiber products.
Advantages of TST-01 ]]></description><pubDate><![CDATA[20240202]]></pubDate></item>
<item>
<title><![CDATA[KRD14 Pneumatic Vertical Shock Response Spectrum Test System]]></title><link><![CDATA[https://cmetechnology.en.ec21.com/KRD14_Pneumatic_Vertical_Shock_Response--11706077_11837074.html]]></link><description><![CDATA[for users to adjust and apply
Output actuator adopts solid-state relay and interlocking AC contact relay, small interference, and the actuator is sensitive
Table preloading pressure is adjustable. Af]]></description><pubDate><![CDATA[20230823]]></pubDate></item>
<item>
<title><![CDATA[New NDT Systems Raptor Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New_NDT_Systems_Raptor_Flaw--11801594_11801615.html]]></link><description><![CDATA[for imaging analysisF1-F8 Context sensitive direct access keysDirect access keys to major menusSPECS : Physical / CaseWeight5.6lb (2.54kg)
Dimensions (W x H x D)5.75in. x 9.50in. x 3.00in. (146mm x 2]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[TJH-2C Parallel Beam Load Cell]]></title><link><![CDATA[https://tgloadcells.en.ec21.com/TJH_2C_Parallel_Beam_Load--11543401_11592317.html]]></link><description><![CDATA[The product is adjusted at the four corners to ensure that it outputs consistently at all points in the specified load plane. Suitable for packaging scales, platform scales, electronic belt scales, b]]></description><pubDate><![CDATA[20220624]]></pubDate></item>
<item>
<title><![CDATA[EMI Receiver System]]></title><link><![CDATA[https://15317383997.en.ec21.com/EMI_Receiver_System--11812738_11812765.html]]></link><description><![CDATA[Basic Info.Model NO.EMI-9KBAfter-sales ServicePerfectWarranty24monthsTrademarkLISUNOriginChinaProduct DescriptionEMI receiver system for EMI (Electromagnetic Interference) radiation conduction or con]]></description><pubDate><![CDATA[20231024]]></pubDate></item>

</channel>
</rss>