<link><![CDATA[https://www.ec21.com/ec-market/frequency_screen--2717/1/frequency screen.html]]></link><item>
<title><![CDATA[Flir C5 - Compact Thermal Camera with Wi-Fi]]></title><link><![CDATA[https://toolshed.en.ec21.com/Flir_C5_Compact_Thermal_Camera--12045274_12045319.html]]></link><description><![CDATA[frequency8.7 HzFocusFocus freeSpectral range8–14 μmScreen size3.5 inVisual camera5 MPDigital camera focusFixedImage PresentationImage adjustmentAutomatic level and spanManual level and span1-Touch]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[FLIR E4 Thermal Imager with MSX Technology 80  60 (4,800 Pixels) with WiFi]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/FLIR_E4_Thermal_Imager_with--11561118_11567185.html]]></link><description><![CDATA[Frequency9 HzField of View45x34 DegreesScreen Size3.0 INIR/Overlay Fusion ImageYes Video OutputNoFocusFixedLaser SpotNoPicture in PictureNoVideo RecordingNoMoveable SpotsNo Touch Screen DisplayNoMini]]></description><pubDate><![CDATA[20250221]]></pubDate></item>
<item>
<title><![CDATA[Stress Cracking Tester]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Stress_Cracking_Tester--12024209_12034904.html]]></link><description><![CDATA[frequency of hand contact with lye.
The visible transparent cover with protective net, can safely observe the situation inside the testing stations in real time.
Electric discharge, high efficiency d]]></description><pubDate><![CDATA[20250106]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[Frequency60 HzField of View34 x 24 DegreesScreen Size3.5 INIR/Overlay Fusion ImageYesVideo OutputYesFocusAdjustable and FixedLaser SpotYesPicture in PictureYesVideo RecordingYesMoveable SpotsYesTouch]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[YH800F Portable Fully Automatic Pressure Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800F_Portable_Fully_Automatic_Pressure--12022422_12022441.html]]></link><description><![CDATA[frequency of calibration points, as well as the single point voltage stabilization time, can be edited. The system automatically divides the range into equal parts, and the pressure rise and fall cyc]]></description><pubDate><![CDATA[20241105]]></pubDate></item>
<item>
<title><![CDATA[GF018A Clamp Type Multimeter Calibrator]]></title><link><![CDATA[https://gfuvegroup.en.ec21.com/GF018A_Clamp_Type_Multimeter_Calibrator--11546876_11999025.html]]></link><description><![CDATA[frequency meters, resistance meter) basic error;
■ The calibrator can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programme]]></description><pubDate><![CDATA[20240905]]></pubDate></item>
<item>
<title><![CDATA[Multi Channel Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Multi_Channel_Ultrasonic_Flaw_Detector--11973711_11973720.html]]></link><description><![CDATA[frequency ultrasound waves to perform inspections and measurements. Ultrasonic inspection is often used to discover and evaluate flaws, measure dimensions, characterize materials, and more.
Features
]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[NDJ-1C Hot Melt Adhesives Brookfield Viscosity Meter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_1C_Hot_Melt_Adhesives--11144324_11144465.html]]></link><description><![CDATA[frequency range
is wide, and the fluctuation of the power supply will not affect the 
measurement accuracy.
4. The
horizontal display device is on the front side of the viscometer. The 
adjustment le]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Digital Infrared Radiometer]]></title><link><![CDATA[https://gatherstar.en.ec21.com/Digital_Infrared_Radiometer--11943208_11943246.html]]></link><description><![CDATA[screen 
Data Rate 
· 
1Hz(High precision mode)、10Hz、20Hz、50Hz(Quick measurement mode) (Signal modulation frequency 1KHz)
Output interface 
RS-422 (Maximum transmission distance 200 meters)
Pow]]></description><pubDate><![CDATA[20240527]]></pubDate></item>
<item>
<title><![CDATA[IEC60335-2-23 Supply Cord Flexing Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60335_2_23_Supply_Cord--11940578_11941763.html]]></link><description><![CDATA[screen, the test frequency and speed can be preset, and built-in load. The hair care appliance with a swivel connection are positioned with their major axis horizontal, the supply cord hanging vertic]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[Fully Automatic Insertion and Extraction Force Tester]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Fully_Automatic_Insertion_and_Extraction--11683816_11853603.html]]></link><description><![CDATA[Product DescriptionTechnical specifications：
1. Maximum test force: 1000N, 500N, 200N, 10N (optional);
2. The sampling frequency is 100Hz;
3. Accurate measurement: Class 0.5;
4. Minimum resolution:]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Temperature Humidity Standard Environment Experiment Calibration Chamber Cabinet]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Temperature_Humidity_Standard_Environment_Experiment--11689458_11689464.html]]></link><description><![CDATA[frequency conversion speed regulation control, through touch screen, set fan speed;
* Multiple protection alarms: constant temperature tank overheating protection, liquid level alarm; rehydration tan]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Metal Oxide Surge Arrester Leakage Current Analyzer HFYH-8001B]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Metal_Oxide_Surge_Arrester_Leakage--11895397_11895400.html]]></link><description><![CDATA[frequency reference voltage and harmonics, active power and phase difference. The real waveform of voltage and current can be displayed on the large color screen. It can accurately analyze the conten]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[MHz (–3 dB)BeamformingScan type: Sectorial or linearGroup quantity: 1Data AcquisitionDigitizing frequency: 400 MHz (12 bits) after interpolation per 5/4Maximum pulsing rate: Up to 6 kHz (C-scan)
]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://karyaabadi.en.ec21.com/Olympus_Nortec_600D_Eddy_Current--11834264_11834281.html]]></link><description><![CDATA[screen option in any display mode.Improved filters for rotary scanner mode.Intuitive interface with Application Selection presets.All-settings configuration page.10 Hz to 12 MHz frequency capacity.Au]]></description><pubDate><![CDATA[20230815]]></pubDate></item>
<item>
<title><![CDATA[EFGH Advanced Force Indicator]]></title><link><![CDATA[https://mikrometry.en.ec21.com/EFGH_Advanced_Force_Indicator--11911431_11911434.html]]></link><description><![CDATA[frequency of this digital force gauge
meter is 1000HZ, the software has tracking and peak measurement modes, which can be applied to the break test of the product, the terminal insertion force test a]]></description><pubDate><![CDATA[20240313]]></pubDate></item>
<item>
<title><![CDATA[Automatic Safety Test System]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Automatic_Safety_Test_System--11882688_11882704.html]]></link><description><![CDATA[frequency; Electric safety wall detecting feature• The LS9955 can test Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current (LLC) and Ground Resistance (GR)• The LS9956 can test]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Low Price Office Chair Backrest Durability Life Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Low_Price_Office_Chair_Backrest--11365007_11372363.html]]></link><description><![CDATA[screen have real-time display of speed, frequency, times and force 12. Standard configuration accessories: 1 set of armrest loading equipment; Cylinder swivel 2 pieces; Chair fixing chair pressing pl]]></description><pubDate><![CDATA[20210423]]></pubDate></item>
<item>
<title><![CDATA[Gelbo Flex Durability Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Gelbo_Flex_Durability_Tester--11854816_11854825.html]]></link><description><![CDATA[output.
Main Parameter
Flex Frequency 45 /minute
Flex Angle 440° (90 mm) or 400° (80 mm)
Capacity 2.5 N.m
Horizontal Stroke 155 mm or 80 mm
Stations 4
Sample Size 280 mm x 200 mm
Power 110~220V
]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[Introduction
LVLP series is linear DC power supply uses power frequency transformer AC/DC conversion technology and matured filtering circuit to ensure pure and &amp; stable DC output
As it uses power fr]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[NAVLF Ultra-low Frequency High Voltage Generator]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/NAVLF_Ultra_low_Frequency_High--10586964_10725175.html]]></link><description><![CDATA[Product introduction 
NAVLF Ultra-low Frequency High Voltage Generator combines the modern digital frequency advanced technology, uses computer control, boost, buck and measurement, automatically ful]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[ST Portable BDV Oil Test Kit,Oil Dielectric Strength Tester]]></title><link><![CDATA[https://aijiezn.en.ec21.com/ST_Portable_BDV_Oil_Test--3459584_11343704.html]]></link><description><![CDATA[frequency induction
heating and PID temperature control algorithm. The oil cup and the heating body
are non-contact, heating evenly, fast and easy to control.
Please contact ASSEN for more details.
]]></description><pubDate><![CDATA[20210224]]></pubDate></item>
<item>
<title><![CDATA[Made in China HZ-3120A Automatic Transformer DC Winding Resistance Tester]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Made_in_China_HZ_3120A--10544358_10544703.html]]></link><description><![CDATA[frequency, easy wiring, simple operation,
Reduce the burden of maintenance personnel, greatly improving the efficiency of the test,to provide security for normal operation of the grid .
features
Can ]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[DC Motor Armature Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/DC_Motor_Armature_Testing_Equipment--11085938_11085990.html]]></link><description><![CDATA[display value+2.5% measuring range+3words
Waveforms limited value
Minimum difference 0.1%
(waveform difference)
impulse internal setting
Available 
Sample frequency
20/40MHz（self-adjustable)
]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[frequency, and ohms to test sensors, transmitters and other instrumentsSource/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmittersPower transmitters during]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Ponovo POM2-3243 Universal Protection Relay Test System for Protective Relays]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_POM2_3243_Universal_Protection--7403753_7403847.html]]></link><description><![CDATA[Frequency
Sine signal
1 … 1000Hz
Transient signal
dc … 10.0kHz
Accuracy
0.3ppm
Phase angle
Range
-360°~+360º
Accuracy (typical)
0.05º
Auxiliary DC supply
0-300V
Power
88W at 110V, 110W at 220V]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[ZXUD - 40 Digital Truecolor Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ndtchina.en.ec21.com/ZXUD_40_Digital_Truecolor_Ultrasonic--6581053_6161468.html]]></link><description><![CDATA[frequency control, good dynamic effect of echo pulse, no lag, meeting the demand of different crystal grains and detection distances.
Intelligent automatic calibration module, flexible adjustment fun]]></description><pubDate><![CDATA[20140520]]></pubDate></item>