<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - h 500]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/h_500--2717/1/h 500.html]]></link><item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[Features:
TiX580 60Hz Industrial Thermal CameraStunning 640 x 480 image quality (320 x 240 resolution is available on the TiX560, TiX520, and TiX500 models)SuperResolution Mode turns your 640 x 480 i]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[ModelStudio Size (D*W*H)mmDimension（D*W*H）mmLRHS-101B-3LJ450×450×500Subject to contractual three-viewLRHS-225B-3LJ500×600×750temperature rangeA:-20℃～150℃ B:-40℃～150℃C:-60℃～150]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[Smoke Detector]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke_Detector--11987076_11987700.html]]></link><description><![CDATA[H
2．
Power supply：220V AC 5
kW，5m
power cord provided，
(110VAC optional)
3．
Tunnel size: 3.1m x 0.7mx
2.1m. 
4．
The tunnel section size is
450mm x 400mm
5．
Aerosol generator：
Built in]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Ultrasonic_Flaw_Detector--11973711_11973715.html]]></link><description><![CDATA[500 independence setup, any criterion can be input freely, we can work in the scene without test block； 
● Big memory of 500 A graph 
● Automated gain and gain scan; 
● Peak Hold and Peak Mem]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[Film-stretching Instrument | Laboratory  Film Stretching Machine]]></title><link><![CDATA[https://potopyangliu.en.ec21.com/Film_stretching_Instrument_Laboratory_Film--11956821_11958740.html]]></link><description><![CDATA[temperature accuracy
±3℃
Stretching motor power
3.5kW
Working voltage
3φ380VAC±10%，1φ220VAC±10%，50Hz
Rated power 
Approx.83kW
L x W x H
5000mm×2100mm×1900mm
Weight
Approx.5000kg
]]></description><pubDate><![CDATA[20240628]]></pubDate></item>
<item>
<title><![CDATA[Touch Screen Temperature Humidity Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Touch_Screen_Temperature_Humidity_Chamber--11164019_11164047.html]]></link><description><![CDATA[H)
400*400*400 mm
450*450*550 mm
600*600*700 mm
700*800*900 mm
1000*1000*1000 mm
External dimensions (D*W*H)
1250*900*1300 mm
950*900*1500 mm
1500*850*1650 mm
1750*1050*1850 mm
2100*1200*1950 mm
Temp]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Sand and Dust Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Sand_and_Dust_Test_Chamber--11853101_11854273.html]]></link><description><![CDATA[500
HD-800
HD-1000
Volume 
512 L
800 L
1000 L
Internal dimension (D*W*H)
800*800*800 mm
900*900*1000 mm
1000*1000*1000 mm
Performance 
Metal screen
standard spacing
50 μm
Spacing between
lines
75 μ]]></description><pubDate><![CDATA[20240619]]></pubDate></item>
<item>
<title><![CDATA[Shop Floor Portable CMM Measurement for Workshop Medium Workpieces]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Shop_Floor_Portable_CMM_Measurement--11944568_11946128.html]]></link><description><![CDATA[500
200
PICO955 
900
500
500
200
Standard machine size and weight please see following table:
PICO 
M odel 
Dimension （mm） 
Measuring Range （mm） 
Workpiece weight（ KG） 
L 
B 
H 
T 
S 
Dx ]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 IP5X and IP6X Sand Dustproof Test Chamber]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60529_IP5X_and_IP6X_Sand--11940576_11946391.html]]></link><description><![CDATA[500*500*500(L*D*H)
Outer dimension(mm)
950*720*1500(L*D*H)
Temperature range
RT+10~+40℃
Humidity
45%-75%
Wire diameter 
of metal net
50μm
Wire interval
75μm
Airflow velocity
≤ 
2.5m/s
Time rang]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[F105/F305/F505/F505H Advanced Test Stand Frame]]></title><link><![CDATA[https://lanetech11.en.ec21.com/F105_F305_F505_F505H_Advanced--11944805_11944810.html]]></link><description><![CDATA[H, no connection cables. Ranges from 0.12 to 500 lbF /0.5 N to 2.5 kN/. Accurate to ±0.1% of full scale.
Series R07 S-beam force sensors is with higher force ranges, compatible with Plug&amp;Test techno]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[Fluke 1587 FC Advanced Electrical Troubleshooting Kit]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_1587_FC_Advanced_Electrical--11927627_11927693.html]]></link><description><![CDATA[500 Hz per MIL-PRF-28800F, Class 2 instrumentRadio frequency communication2.4 GHz ISM BandRadio frequency certificationFCC: T68-FBLE, IC: 6627A-FBLEElectromagnetic compatibilityInternational IEC 6132]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[H1 Micro Motion 20002000 IS970197129739Moore Products 3441 Rosemount115120883001C3051, 3051S3044C64431443244, 3144P SiemensSITRANS P DSSITRANS P ES SMARLD301TT3011 ViatranI/A Pressure WikaUNITRANST32]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Hot Tack Tester ASTM F2029 Hot Seal Strength Testing Instrument Plastic Packaging Hot Tack Strength]]></title><link><![CDATA[https://celtec.en.ec21.com/Hot_Tack_Tester_ASTM_F2029--9267548_9296214.html]]></link><description><![CDATA[500N）
Accuracy 0.5 F.S.
Resolution 0.01N
Stroke 500mm
Gas Source 0.7MPa
Port Size Ф4mm PU Hose
Dimensions 1100mm(L)×390mm(W)×420(H)
Power AC220V50Hz
Hot Tack Tester Standards
ASTM F1921, ASTM F2]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[100kW/200kW/500kW/800kW/1000kW/1200kW/2000kW AC Dummy Resistive Load Bank for Generator Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/100kW_200kW_500kW_800kW_1000kW--11807078_11807097.html]]></link><description><![CDATA[: -20ºC to 50ºC
Humidity : up to 100%
Altitude : up to 2500m
Atmospheric pressure : 86 to 106kPa
Dimensions(L*W*H) : 2120*1520*2180mm
Weight : 1800Kg
Company Profile
Certificates
Contact US
]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Glow-wire Test Apparatus]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Glow_wire_Test_Apparatus--9657760_11802295.html]]></link><description><![CDATA[The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) &lt; basic testing methods]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[Specifications:HousingOverall dimensions (W x H x D): 267 mm × 208 mm × 94 mm (10.5 in. × 8.2 in. × 3.7 in.)Weight: 3.4 kg (7.5 lb) with battery Data StorageStorage devices: SDHC card or most sta]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[High Performance FTIR Fourier Transform Infrared Spectrometer]]></title><link><![CDATA[https://gbpitester.en.ec21.com/High_Performance_FTIR_Fourier_Transform--11631034_11631045.html]]></link><description><![CDATA[500Khz，24 bit A/D converterTemperature requirement15~35℃Size450(L)×350(W)×235(H)mmWeight14kg
Company ProfileWe GBPI is a professional manufacturer focused on developing 
and producing packaging]]></description><pubDate><![CDATA[20220901]]></pubDate></item>
<item>
<title><![CDATA[Auto Servo Tensile Tester Universal Testing Equipment Lab Testing Machine]]></title><link><![CDATA[https://systester18.en.ec21.com/Auto_Servo_Tensile_Tester_Universal--10834076_10927099.html]]></link><description><![CDATA[500N, 1000N.
7: Silence running,&lt;25db@1000.
8: ISO, ASTM standards test available and non-standard test available.
9: Electronic limit, computer preset, non-mechanical limit.
10: Overload protection,]]></description><pubDate><![CDATA[20210625]]></pubDate></item>
<item>
<title><![CDATA[Surge Generator]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Surge_Generator--11882688_11882701.html]]></link><description><![CDATA[H-SPSG61000-5H15-SPSG61000-5H20-SPSG61000-5HOutput Voltage(Open)1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%Output Current(Short)8/20μs±20%8/20μs±20%8/20μ]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[MOSIP Certified Fingerprint Scanner]]></title><link><![CDATA[https://miaxis2024.en.ec21.com/MOSIP_Certified_Fingerprint_Scanner--11895938_11895942.html]]></link><description><![CDATA[500dpi
Active platen area
15.24mm x 20.32mm
Image Size
300*400 pixel
FAP (fingerprint acquisition profile)
FAP20
Security
FTM based, MOSIP L1 Device, SBI 2.0
Compliance
FBI-PIV, MOSIP L1, CE &amp; FCC ce]]></description><pubDate><![CDATA[20240131]]></pubDate></item>
<item>
<title><![CDATA[New Energy Vehicle Test Bench , Auto Fault Test Can Test Signal Test. AutoTest Bench]]></title><link><![CDATA[https://leoscan.en.ec21.com/New_Energy_Vehicle_Test_Bench--11841594_11841608.html]]></link><description><![CDATA[H) (customizable)
Signal box
ABS Signal box (customizable)
500*400*200mm(L*W*H) (customizable)
DC power
Output voltage range:0~600V
Output current range:0~10A
Customized and configured according to t]]></description><pubDate><![CDATA[20230911]]></pubDate></item>
<item>
<title><![CDATA[SPT for Soil Investigation Tianpeng 63.5kg CN;HEB 10kg 20kg 30kg Petrol Engine]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/SPT_for_Soil_Investigation_Tianpeng--10975742_11481264.html]]></link><description><![CDATA[500 and 750 mm by means of an adaptor bracket.
The dynamic probing rig SPT-H is driven by a hydraulic motor fed by a separate hydraulic power pack.
Furthermore the SPT-C version offers the vital adva]]></description><pubDate><![CDATA[20230613]]></pubDate></item>
<item>
<title><![CDATA[Vertical Excitation Changeover Temperature Humidity Testing Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Vertical_Excitation_Changeover_Temperature_Humidity--11825687_11825688.html]]></link><description><![CDATA[500x400 500x600x500 600x750x500 600x850x800 1000x1000x8001000x1000x1000WxHxD (mm)External Dimension 950x1650x9501050x1750x10501200x1900x11501200x1950x13501600x2000x14501600x2100x1450WxHxD (mm)Tempera]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Active Piston Prover]]></title><link><![CDATA[https://royreal.en.ec21.com/Active_Piston_Prover--11907986_11908005.html]]></link><description><![CDATA[500）mL/min
≤0.05%，≤0.1%（0-100）kPa
HQD-003
3L
（0.0006~0.18）m³/ h,（0.01~3）L/min
≤0.05%，≤0.1%（0-100）kPa
HQD-005
5L
（0.0012~0.36）m³/ h,（0.02~6）L/min
≤0.05%，≤]]></description><pubDate><![CDATA[20240301]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/Used_Olympus_Nortec_600D_Eddy--11801594_11801596.html]]></link><description><![CDATA[500 files (program and data).On-board file preview.Portable and LightweightThe NORTEC 600 weighs only 1.6 kg and is delivered with a factory-installed hand strap that provides direct thumb access to ]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[High Purity Gas Generator, Hydrogen Generator, Nitrogen Generator]]></title><link><![CDATA[https://huishiyiqi2024.en.ec21.com/High_Purity_Gas_Generator_Hydrogen--11907876_11909357.html]]></link><description><![CDATA[500
Output pressure (MPa) 0.4 (factory set at 0.3) adjustable
Working power supply 110/220V ± 10%; 50/60Hz ± 5%
Maximum power (W) 200
Environmental conditions and temperature: 10-40 ℃; Relative h]]></description><pubDate><![CDATA[20240307]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Lightning Surge Generator]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Voltage_Lightning_Surge_Generator--11812738_11812759.html]]></link><description><![CDATA[H-SPSG61000-5TOutput Voltage (Open)1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%Output Current (Short)8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%Output Imped]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Multi-function Optical Fiber Light Source CEL-FES300 Photocatalysis]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Multi_function_Optical_Fiber_Light--11446837_11446865.html]]></link><description><![CDATA[500nm (No ozone)Working spot diameter(Optional continuous adjustment accessories)Above 60mmOptical fiber output square spot10*10mm—60*60mm，Adjust by converging lensOutput uniformity of optical fi]]></description><pubDate><![CDATA[20221027]]></pubDate></item>
<item>
<title><![CDATA[Cold and Hot Shock Test Box / Cold and Hot Impact Tester]]></title><link><![CDATA[https://lituotest.en.ec21.com/Cold_and_Hot_Shock_Test--11372570_11372577.html]]></link><description><![CDATA[Technical parameters 1. Inner box size (W*H*D) : 500*400*400mm(80L)2. Outer box size (W*H*D) : 1480*1900*1550mm3. Temperature range :(-45ºC, -55ºC, -65ºC, -70ºC) ~ 150ºC4. Temperature range of h]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 IP56X Sand Dustproof Test Chamber]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC60529_IP56X_Sand_Dustproof_Test--11405200_11418211.html]]></link><description><![CDATA[500*500*500(L*D*H)
Outer dimension(mm)
950*720*1500(L*D*H)
Temperature range
RT+10~+70℃
Humidity
45%-75%
Wire diameter of metal net
50μm
Wire interval
75μm
Airflow velocity
≤ 2.5m/s
Time range
]]></description><pubDate><![CDATA[20210722]]></pubDate></item>
<item>
<title><![CDATA[Manifold Filtration Device]]></title><link><![CDATA[https://shenzhilin.en.ec21.com/Manifold_Filtration_Device--11772711_6504599.html]]></link><description><![CDATA[H: 105mmx135mm
Material of Funnel: PP and Stainless Steel
Material of Support: Stainless Steel
Filter head: Detachable, screw it with holder
Filter head: 6- place, 3-place, 2-place, 1-place 
SS funne]]></description><pubDate><![CDATA[20230721]]></pubDate></item>
<item>
<title><![CDATA[Computer Controlled Automobile Seat Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/Computer_Controlled_Automobile_Seat_Testing--4048548_5133616.html]]></link><description><![CDATA[space
800mm or customized as required
12
Effective compression space
700mm
13
Power supply (with grounded protective measures)
~220V&amp;plusmn;10%/50Hz
14
Dimension (L*W*H)
660&amp;times;415&amp;times;1500 
]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[AS-2011 Micron Laser Particle Size Analyzer 0.1-500um]]></title><link><![CDATA[https://aimsizer.en.ec21.com/AS_2011_Micron_Laser_Particle--4628668_4628669.html]]></link><description><![CDATA[500&amp;mu;m
Accuracy:&lt;1%
Repeatability:&lt;1%
Test method:Liquid
Light source:Semiconductor laser (635nm, 3mw, 25000hrs)
Scanning speed: 2000/sec
Test time:&lt; 1 minute, sample preparation not counted
Power ]]></description><pubDate><![CDATA[20100926]]></pubDate></item>
<item>
<title><![CDATA[Horizontal and Vertical Flammability Tester UL94 IEC 60695]]></title><link><![CDATA[https://fulfilling.en.ec21.com/Horizontal_and_Vertical_Flammability_Tester--5441143_9767620.html]]></link><description><![CDATA[500 w) level 
12.Experimental background: black background 
13.Test process, test program automatic control, independent convulsions 
14.Studio volume: 0.75 cubic, stainless steel chassis 
15.Dimensi]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Gas Pycnometer Analyzer G-DenPyc 2900]]></title><link><![CDATA[https://goldapp.en.ec21.com/Gas_Pycnometer_Analyzer_G_DenPyc--9431275_9269540.html]]></link><description><![CDATA[H-Sorb two-stage-stepping mode further ends splash happening
Sample Container: 50mm (diameter) and 180ml (500ml is available) big cylinder sample cell is convenient for samples filling; Exclusive G-D]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Quick Thermal Conductivity Meter QTM-700/QTM-710]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Quick_Thermal_Conductivity_Meter_QTM--8755030_8755121.html]]></link><description><![CDATA[H)mmWeightApprox. 4kgCE markingCE marking (EN61326-1, EN61010-1), suitable for RoHS
※1 Measurement accuracy and repeatability of Thin film measurement depends on the state of the sample 
※2 Refer]]></description><pubDate><![CDATA[20190329]]></pubDate></item>
<item>
<title><![CDATA[Anti-yellowing Aging Test Chamber]]></title><link><![CDATA[https://annie0423.en.ec21.com/Anti_yellowing_Aging_Test_Chamber--9938796_9938808.html]]></link><description><![CDATA[500W&amp;times;1300D&amp;times;1360Hmm
Materials
Inside and Outside SUS#304 stainless steel 
Temperature range
RT+10~70&amp;deg;C
Temperature uniformity
&amp;plusmn;2&amp;deg;C
Temperature fluctuation
&amp;plusmn;0.5&amp;deg;C
]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>