<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - heating power supply]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/heating_power_supply--2717/1/heating power supply.html]]></link><item>
<title><![CDATA[Fluke TI480 PRO 60 Hz, 640 X 480 High-Performance IR Thermal Camera]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_TI480_PRO_60_Hz--11561118_11932301.html]]></link><description><![CDATA[productivity.
Included Components
1 - AC Charger/Power Supply with Worldwide Adapters
2 - Smart Lithium Ion Batteries with Charging Bay
1 - USB Cable
1 - HDMI Video Cable
1 - 4 GB Micro SD Card
]]></description><pubDate><![CDATA[20250129]]></pubDate></item>
<item>
<title><![CDATA[Heat Alarm &amp; Detector Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Heat_Alarm_Detector_Test_Tunnel--11987076_11987723.html]]></link><description><![CDATA[heating rate of 0.2 ℃/min, 1 ℃/min, 3 ℃/min, 5 ℃/min,
10 ℃/min, 20 ℃/min and 30 ℃/min as standard required. The maximum temperature is up to 160 ℃. During the test, the temperature wi]]></description><pubDate><![CDATA[20241122]]></pubDate></item>
<item>
<title><![CDATA[NDJ-1C Hot Melt Adhesives Brookfield Viscosity Meter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_1C_Hot_Melt_Adhesives--11144324_11144465.html]]></link><description><![CDATA[configuration
Host: 1 set
External drum: 2 piece
High temperature heating furnace: 1 piece
Rotor: 21/#, 27#, 28#, 29#
Temperature control device: 1piece
Power supply, cable: 2 piece
]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Thermal Shock Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Thermal_Shock_Test_Chamber--11164019_11164171.html]]></link><description><![CDATA[heating temperature upper limit
200℃
Heating time
R.T...+200℃: 40min (approximately);
Low temperature area
Temperature exposure range
0...-75℃
Precooling temperature lower limit
-75℃
Cooling ]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-4 UL94 Horizontal and Vertical Flame Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_4_UL94_Horizontal--11940578_11941787.html]]></link><description><![CDATA[tray, sample clamp, wrapping tissue 12g/m2 ~
30g/m2, steel wire mesh, height gauge, Cotton and etc.
Dimension of apparatus
1100mm(W)*700mm(D)*1300mm (H)
Power supply
AC220V, 50Hz, ≤500W
]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[power real-time sampling；
 When line current value≧5A，CT can supply meet the indicator power requirement
 Sampling accuracy: I&lt;10A±1%，I&gt;10A±2%
 Sensor factory automatic calibration]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[Xenon Lamp Weather Resistance Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Xenon_Lamp_Weather_Resistance_Test--11853101_11854260.html]]></link><description><![CDATA[brand
Cooling mode
Air cooling
Heater 
Nickel-chromium alloy heating wire
Temperature sensor
Pt100
Power supply
AC 220V/380V, 50Hz, three-phase four-wire + earth wire, ground
resistance&lt;4Ω
]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[Heating Oil Bath Series]]></title><link><![CDATA[https://xataikang.en.ec21.com/Heating_Oil_Bath_Series--9935656_9936242.html]]></link><description><![CDATA[power
1.5KW
Temperature
&lt;=2.5&amp;ordm;C
Heating Power(W)
2000
Flow rate
18.3L/min
Humidity
60%
Power supply
380V/50Hz
Adjustable range
Room-250&amp;ordm;C
Viscosity of applied heat transfer oil
Below 500&amp;or]]></description><pubDate><![CDATA[20170216]]></pubDate></item>
<item>
<title><![CDATA[Crude Oil Water Content Meter]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Crude_Oil_Water_Content_Meter--11718430_11856617.html]]></link><description><![CDATA[Heating method: electric heating mantle heating
8. Working power supply: AC220，240
V 50，60
HZ
9. Machine power: 1000W
10. Instrument size: 420*320*400mm
11. Net weight: 3KG
Main Feature s 
1. Ele]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[Water Vapor Permeation Rate Tester Weighing Method Humidity Permeability Testing Machine]]></title><link><![CDATA[https://systester18.en.ec21.com/Water_Vapor_Permeation_Rate_Tester--10834034_10898901.html]]></link><description><![CDATA[flow
0~200 ml/min
Gas interface
1/8inch
Power supply
AC 220V 50Hz
Dimension
330mm(L) * 600mm(D) * 330mm(W)
Net weight
30kg
Products Catalog 
What we can provide
Packing
Export Areas
Contact 
]]></description><pubDate><![CDATA[20221214]]></pubDate></item>
<item>
<title><![CDATA[Boiling Test Box]]></title><link><![CDATA[https://yuanchenwujin68.en.ec21.com/Boiling_Test_Box--10707899_10963354.html]]></link><description><![CDATA[Power: 220V 50Hz 3Kw (Customized)
Outside Size: 400mm*255mm*480mm
Inside Size: 400mm*255mm*480mm
At most 6 samples with 300mm*300mm
Glazing Boiling Test Box
, High
Temperature Test Oven
Supplier
&amp; Ex]]></description><pubDate><![CDATA[20230719]]></pubDate></item>
<item>
<title><![CDATA[Solar Simulator Xenon Lamp Light Source Solar Cell IV Test]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Solar_Simulator_Xenon_Lamp_Light--11446867_11446868.html]]></link><description><![CDATA[CEL-S500-T5 solar simulator xenon light source, using the xenon lamp power supply developed by CEL Jinyuan, the light output stability increased significantly, &lt; ± 0.5%, which is conducive to solar ]]></description><pubDate><![CDATA[20240104]]></pubDate></item>
<item>
<title><![CDATA[Cold and Hot Shock Test Box / Cold and Hot Impact Tester]]></title><link><![CDATA[https://lituotest.en.ec21.com/Cold_and_Hot_Shock_Test--11372570_11372577.html]]></link><description><![CDATA[power failure reset function, can choose BREAK, COLD, HOT, can be set at will; test data can be automatically generated EXCELL documents, temperature graphs, you can view and download.
2.Heating and ]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[Automatic Melting Point Tester]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Automatic_Melting_Point_Tester--11600339_11776721.html]]></link><description><![CDATA[Heating rate:
0.1℃--20℃(200 steps steplessly adjustable)
Small capillary size:
outer diameter φ1.4mm, inner diameter: φ1.0mm
Large capillary size:
outer diameter φ4.2mm, inner diameter: φ3.8m]]></description><pubDate><![CDATA[20230426]]></pubDate></item>
<item>
<title><![CDATA[Tensile Tester]]></title><link><![CDATA[https://pnshar.en.ec21.com/Tensile_Tester--6815941_6804873.html]]></link><description><![CDATA[Power supply: AC220V&amp;plusmn;10% 2A 50HZ 2. Measuring range: 4 options: 0～30N /0～100N/0～300N/0～500N 3. Tensile velocity: 1.0～400.0 mm/min (Can be adjusted digitally) 4. Interval of clamping ]]></description><pubDate><![CDATA[20120619]]></pubDate></item>
<item>
<title><![CDATA[Programmable Control Temperature Humidity Tester]]></title><link><![CDATA[https://annie0423.en.ec21.com/Programmable_Control_Temperature_Humidity_Tester--9938678_9938741.html]]></link><description><![CDATA[heating down, dehumidifying, and humidifying can be operated independently so as to reduce the cost of testing, extend the operating life of the machine and decrease the failure rate.
6.Water Supply ]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>