<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - impedance]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/impedance--2717/1/impedance.html]]></link><item>
<title><![CDATA[Accurate Ultrasonic Impedance Analyzer Frequency Testing Equipment for Ultrasound]]></title><link><![CDATA[https://funsonic.en.ec21.com/Accurate_Ultrasonic_Impedance_Analyzer_Frequency--11748582_11858229.html]]></link><description><![CDATA[Professional and precise equipment for measuring the frequency and power of ultrasonic transducers and ceramic discs.]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Fluke 3540 FC KIT Three-Phase Power Monitor]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_3540_FC_KIT_Three--12045274_12045343.html]]></link><description><![CDATA[Impedance10 MΩ each phase to neutralBandwidth42.5 Hz to 3.5 kHzScaling1:1, variableCurrent InputsNumber of inputs: 3, mode selected automatically for attached sensorCurrent Sensor Output VoltageClam]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[0.8-8GHz Precision 4 Way Power Splitter Power Divider with SMA Connector]]></title><link><![CDATA[https://tojoin001.en.ec21.com/0.8_8GHz_Precision_4_Way--11449529_11449555.html]]></link><description><![CDATA[Impedance（Ω）
—
50
—
Connectors
—
SMA
—
Power Capacity（W）
—
10
—
Operating Temperature（°C）
-30
normal temperature
+70
Physical 
D
imension（mm）
—
72.1×55
×13.2
—
]]></description><pubDate><![CDATA[20241204]]></pubDate></item>
<item>
<title><![CDATA[IEC61180-1 1.2/50us Impulse Voltage Generator]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61180_1_1.2_50us_Impulse--11944039_11944052.html]]></link><description><![CDATA[impedance can be customized, and Interface is provided to connect to an external oscilloscope to monitor waveform.
2. SpecificationModelLSG-255Control and display modeLCD+touch screenoutput voltage (]]></description><pubDate><![CDATA[20240528]]></pubDate></item>
<item>
<title><![CDATA[Fluke 1587 FC Advanced Electrical Troubleshooting Kit]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_1587_FC_Advanced_Electrical--11927627_11927693.html]]></link><description><![CDATA[Impedance10 MΩ (nominal), &lt;100 pF, ac-coupledCommon mode rejection ratio (1 kΩ unbalanced)&gt;60 dB at dc, 50 or 60 HzDC voltage measurementRangeResolutionAccuracy 1587 FC1± (% of Rdg + Counts)Accura]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[IEC61180-1 Impulse Withstand Voltage Generator with 1.2/50us Waveform]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61180_1_Impulse_Withstand_Voltage--11421920_11425210.html]]></link><description><![CDATA[impedance (optional): 2Ω,500Ω±10%
6) Times: 1~9999 times
7) Surge interval: 3~999s
8) Working environment: 15℃~35℃ (temperature), 10%~75% (humidity)
9) Working power: 220V±10% AC, 50/60Hz
10)]]></description><pubDate><![CDATA[20210805]]></pubDate></item>
<item>
<title><![CDATA[100kW/200kW/500kW/800kW/1000kW/1200kW/2000kW AC Dummy Resistive Load Bank for Generator Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/100kW_200kW_500kW_800kW_1000kW--11807078_11807097.html]]></link><description><![CDATA[impedance DC2000V/10MΩ above 
Withstand voltage AC2000v for 1 min; 
Resistance error of each resistance tube: ±2%
Can stable work under 350ºC.
Load control : automatic.Control the load through the]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[18650 Lithium Battery]]></title><link><![CDATA[https://chamglobal.en.ec21.com/18650_Lithium_Battery--11857535_11857537.html]]></link><description><![CDATA[Impedance （mΩ)
Max. Continuous Dis. Current
Cycle Life
Discharge Operating Temperature (℃)
18650F56
2200
3.7
≤60
2.2 A (1 C)
≥300
-20 ~ 60
18650F8M7
2600
3.6
≤30
7.5 A (3 C)
≥1000
-20 ~ ]]></description><pubDate><![CDATA[20231023]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[impedance: 35 Ω (pulse-echo mode); 30 Ω (pitch- catch mode)ReceiverGain: 0 dB to 80 dB, maximum input signal 550 mVp-p (full-screen height)Input impedance: 60 Ω (pulse-echo mode); 150 Ω (pitch- c]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[Surge Generator]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Surge_Generator--11882688_11882701.html]]></link><description><![CDATA[Impedance2Ω and 12Ω2Ω and 12Ω2Ω, 12Ω and 500Ω2Ω, 12Ω and 500Ω2Ω, 12Ω and 500Ω2Ω, 12Ω and 500ΩOutput VoltageRange0~4.8KV±10%0~6KV±10%0~10KV±10%0~15KV±10%0~20KV±10%0~10KV±10%Outpu]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Ponovo T1000 Primary Injection Test Set for Different Types of Relays]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_T1000_Primary_Injection_Test--11744128_11737778.html]]></link><description><![CDATA[Impedance, Polarity, etc.•Multimeter Function•Easy to control•PC report tool software•Advanced high power constant current source with pulse width modulation technology for automated testing]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Fluxmeters Electromagnetic Flux Meter Price Magnetic Flux Flow Density Meter]]></title><link><![CDATA[https://jackietsui.en.ec21.com/Fluxmeters_Electromagnetic_Flux_Meter_Price--8508233_11795040.html]]></link><description><![CDATA[impedance, the coil has small effect on the test.
6. Inspection of conventional DC magnetic field;
Technical index
1. Test range: ± 3.0000mWb \ ± 30.000mWb \ ± 300.00mWb \ ± 3000.0mWb four levels]]></description><pubDate><![CDATA[20230522]]></pubDate></item>
<item>
<title><![CDATA[VICIMETER Megga Resistance Testing VC60B+ Insulation Tester]]></title><link><![CDATA[https://vicimeter.en.ec21.com/VICIMETER_Megga_Resistance_Testing_VC60B--11555545_8944178.html]]></link><description><![CDATA[impedance
1MΩ
Sampling rate
3 times/Sec.
AC frequency response
40-200Hz
Operation method
Manual range
Max display
1999
LCD size
75 x 52mm
Power source
1.5V AA battery x6pcs, or external DC 9V power ]]></description><pubDate><![CDATA[20220419]]></pubDate></item>
<item>
<title><![CDATA[Fully Automatic Insertion and Extraction Force Tester]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Fully_Automatic_Insertion_and_Extraction--11683816_11853603.html]]></link><description><![CDATA[impedance test system, the dynamic impedance can be tested and the load impedance travel curve can be drawn at the same time when testing the plugging force.
The standard accessories：
1、Sensor: o]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Ground Resistance Tester]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Ground_Resistance_Tester--11895397_11895404.html]]></link><description><![CDATA[impedance tester of the special frequency ground network are accurate and repeatable. It is an ideal instrument for the measurement of the characteristic parameters of large and medium grounding grid]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[Transformer Variable Ratio of Entire Inspection Test]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/Transformer_Variable_Ratio_of_Entire--10586983_10714599.html]]></link><description><![CDATA[impedance &amp;ge; 100K&amp;Omega;, then the standard variable ratio Of the error is less than 0.02%. 
2. Resolution test function 
When the function selector switch is set to &quot;Resolution&quot;, it can test the r]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Made in China HZ-3120A Automatic Transformer DC Winding Resistance Tester]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Made_in_China_HZ_3120A--10544358_10544703.html]]></link><description><![CDATA[impedance, phase angle and other data when measuring, to better analyze the quality of the test product 
The instrument uses 8.0 inches 800 × 600 dot matrix K600 + core 65K color DGUS screen, touch ]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[New Olympus BondMaster 600 Multimode Bond Tester]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_BondMaster_600_Multimode--11801594_11801602.html]]></link><description><![CDATA[impedance analysis (MIA) method.
Portable, Lightweight, and ErgonomicThe ergonomic design of the BondMaster 600 is convenient for difficult-to-access inspection locations. For inspection in tight spa]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Lightning Surge Generator]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Voltage_Lightning_Surge_Generator--11812738_11812759.html]]></link><description><![CDATA[Impedance2Ω and 12Ω2Ω and 12Ω2Ω and 12Ω2Ω 12Ω and 500Ω2Ω and 12ΩOutput Voltage Range0~4.8KV±10%0~4.8KV±10%0~6KV±10%0~10KV±10%0~6KV±10%Output Current Range0~2.4KA±10%0~2.4KA±10%0~3KA]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Electrical Asphalt/Soil Non-nuclear Density Gauge for Civil Engineering]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/Electrical_Asphalt_Soil_Non_nuclear--10976325_10976334.html]]></link><description><![CDATA[impedance (consisting of the pavement’s composite resistivity and dielectric constant). This response is then calibrated to pavement density (TransTech, 1997
[1]).
Using the most advanced non-nucle]]></description><pubDate><![CDATA[20230530]]></pubDate></item>

</channel>
</rss>