<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - insulated heating wire]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/insulated_heating_wire--2717/1/insulated heating wire.html]]></link><item>
<title><![CDATA[Thermal Shock Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Thermal_Shock_Test_Chamber--11164019_11164171.html]]></link><description><![CDATA[heating temperature upper limit
200℃
Heating time
R.T...+200℃: 40min (approximately);
Low temperature area
Temperature exposure range
0...-75℃
Precooling temperature lower limit
-75℃
Cooling ]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[IEC60695-11-4 UL94 Horizontal and Vertical Flame Test Apparatus]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC60695_11_4_UL94_Horizontal--11940578_11941787.html]]></link><description><![CDATA[insulating sleeve heat resist to 
1250 ℃), 2 pieces to detect the temperature
4). Temperature measuring copper blocks
Test background
black
Volume of chamber
0.75 CBM, exhaust 
hole
: Φ70mm
Therma]]></description><pubDate><![CDATA[20240524]]></pubDate></item>
<item>
<title><![CDATA[High Low Temperature Humidity Test Chamber]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/High_Low_Temperature_Humidity_Test--11853101_11854241.html]]></link><description><![CDATA[Heating and cooling rate
≥1℃/min (-55℃～+85℃ )
Material 
Shell material
Cold rolled sheet steel, spray plastics on
surface
Internal material
SUS304 Stainless steel
Thermal insulation materia]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/3kW_3.5kW_4kW_5kW_6kW--11807084_11807114.html]]></link><description><![CDATA[Insulation class: F5: Load: resistive load6: Wire connection: 2/3 ways input. Control the power input separately.7: Control method: manual with ABB/Schneider brand MCB (Miniature circuit breaker)8: P]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Glow-wire Test Apparatus]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Glow_wire_Test_Apparatus--9657760_11802295.html]]></link><description><![CDATA[wire testing equipment is applicable to flame resistance test of all levels of QC departments and corresponding enterprises.
Specifications:• Heating temperature: adjustable continuously within the]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[WDW Microcomputer Control Electronic Universal Tester]]></title><link><![CDATA[https://shiyanji.en.ec21.com/WDW_Microcomputer_Control_Electronic_Universal--4048548_4096496.html]]></link><description><![CDATA[Heat Insulating Material; JGJ144 Technical Criterion for Outer Wall Heat Insulating Engineering.
2. Basic configuration:
Name
Item
Qty.
Main machine
100KN portal frame; shell is sprayed with plastics]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[Quick Thermal Conductivity Meter QTM-700/QTM-710]]></title><link><![CDATA[https://kyotokem.en.ec21.com/Quick_Thermal_Conductivity_Meter_QTM--8755030_8755121.html]]></link><description><![CDATA[Wire Method. Measurements of thermal conductivity of firebricks or heat insulation materials at high and low temperature are possible.Vessel for powderVessel for powderThe measurement of thermal cond]]></description><pubDate><![CDATA[20190329]]></pubDate></item>

</channel>
</rss>