<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - limit temperature sensor]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/limit_temperature_sensor--2717/1/limit temperature sensor.html]]></link><item>
<title><![CDATA[Bebur BT6308 Ozone Analyzer for Drink Water Wastewater Industrial Process Water]]></title><link><![CDATA[https://bebur.en.ec21.com/Bebur_BT6308_Ozone_Analyzer_for--12032929_12032934.html]]></link><description><![CDATA[temperature of the sample water, and the output signal of the sensor is compensated by an electronic device, so that the measured value can be corrected with the change of temperature (temperature co]]></description><pubDate><![CDATA[20241224]]></pubDate></item>
<item>
<title><![CDATA[40m 20HZ 1mm Accuracy COM RXTX Serial Port TTL Digital Output Raspberry Pi Laser Distance Sensor]]></title><link><![CDATA[https://lasersensor2003.en.ec21.com/40m_20HZ_1mm_Accuracy_COM--11950652_11976847.html]]></link><description><![CDATA[Sensor module,including but not limited to range, accuracy, baud rate, frequency, communication interface, temperature, etc. Our industrial laser distance sensor is TTL output digital output, support]]></description><pubDate><![CDATA[20240729]]></pubDate></item>
<item>
<title><![CDATA[Thermal Shock Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Thermal_Shock_Test_Chamber--11164019_11164171.html]]></link><description><![CDATA[temperature area
Temperature exposure range
+60...+200℃
Preheating temperature upper limit
200℃
Heating time
R.T...+200℃: 40min (approximately);
Low temperature area
Temperature exposure range
]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[TJH-2C Parallel Beam Load Cell]]></title><link><![CDATA[https://tgloadcells.en.ec21.com/TJH_2C_Parallel_Beam_Load--11543401_11592317.html]]></link><description><![CDATA[Temperature Effect On Output
±0.02% FS/10℃
Operating Temperature Range
-20~+65 ℃
Input Resistance
380±10 Ω
Output Resistance
350± 3 Ω
Insulation Resistance
＞5000 MΩ
Safe Load Limit
150% F]]></description><pubDate><![CDATA[20220624]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[sensor mapping of dual sensor temperature transmitters.Read HART PV function and smart transmitter digital output while measuring analog mA output.Read and write HART configuration functions to make ]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Cold and Hot Shock Test Box / Cold and Hot Impact Tester]]></title><link><![CDATA[https://lituotest.en.ec21.com/Cold_and_Hot_Shock_Test--11372570_11372577.html]]></link><description><![CDATA[Temperature impact range: -40 ~ 100ºC9. Temperature fluctuation: ≤±0.5ºC10. Temperature deviation: ≤±2.0ºC11. Temperature recovery time: 3 ~ 5 minutes12. Sample limitation: the test or stora]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[Thermal Shock Test Chamber (Two Zones)]]></title><link><![CDATA[https://lilyviyo12345.en.ec21.com/Thermal_Shock_Test_Chamber_Two--11853101_11853190.html]]></link><description><![CDATA[temperature area
Temperature exposure
range
+60～+200℃
Preheating temperature
upper limit
200℃
Heating time
R.T～+200℃:40 min (approximately
)
Low temperature area
Temperature exposure
range
]]></description><pubDate><![CDATA[20231013]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Thickness Meter TM-8812 for Sale]]></title><link><![CDATA[https://105landtek.en.ec21.com/Ultrasonic_Thickness_Meter_TM_8812--9545005_11795523.html]]></link><description><![CDATA[Sensor
3. Coupling Agent
4. Carrying Case
5. Operating Manual
Optional Accessories:
1. 6M Φ6 mm thin Material Probe:
Measuring range (steel): 1.0~50.0 mm Operating temperature: -10~60°C
2. 5M Φ12 ]]></description><pubDate><![CDATA[20230523]]></pubDate></item>
<item>
<title><![CDATA[ISO 15105-2 Permeable Film Oxygen Transmission Rate Tester GBPI]]></title><link><![CDATA[https://gbpitester.en.ec21.com/ISO_15105_2_Permeable_Film--11629254_11631099.html]]></link><description><![CDATA[Temperature range 15~45℃(5~50℃optional ）Temperature
accuracy ±0.1℃Humidity range 30~90%RH，100%RHHumidity accuracy ±1%RHTest area 50.24 cm2Sample size Φ100 mmSample thickness ≤3mmNumber]]></description><pubDate><![CDATA[20220901]]></pubDate></item>

</channel>
</rss>