<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - min fan]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/min_fan--2717/1/min fan.html]]></link><item>
<title><![CDATA[Ice-covered Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Ice_covered_Test_Chamber--11943432_12023832.html]]></link><description><![CDATA[ModelStudio Size (D*W*H)mmDimension（D*W*H）mmLRHS-8000A-FB2000×2000×20002480×2510×2480Temperature range－10℃～25℃heating rate-10℃～25℃≤15min （unladen）cooling rate25℃～-10]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[Smoke Heat Detector Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Smoke_Heat_Detector_Test_Tunnel--11987076_11987966.html]]></link><description><![CDATA[min≤⊿m /⊿t ≤0.1dB/m/min,
preset to 0.05dB/m, which can be set in the software
6．
Optical smoke densitometer: 
ADI circuit and advanced optical design
transmitted light, wavelength 880nm~950]]></description><pubDate><![CDATA[20241019]]></pubDate></item>
<item>
<title><![CDATA[ISO16750-4 Clause 5.4.2 Ice Water Splash Test Chamber for Automotive Parts]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/ISO16750_4_Clause_5.4.2_Ice--11940576_11941038.html]]></link><description><![CDATA[fan motor and a SUS304# stainless steel multi-blade impeller resistant to high and low temperature to achieve strong convection and vertical diffusion circulation, so that the temperature in the labo]]></description><pubDate><![CDATA[20240522]]></pubDate></item>
<item>
<title><![CDATA[100kW/200kW/500kW/800kW/1000kW/1200kW/2000kW AC Dummy Resistive Load Bank for Generator Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/100kW_200kW_500kW_800kW_1000kW--11807078_11807097.html]]></link><description><![CDATA[Min. step : 1kW or customizedLoad step : 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,100kW,100kW,100kW,100kW,100kW,100kW,100kW,100kWLoad connection : copper bar, 3-phases 4 wiresResistor : 8020Ni-Cr al]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Gold Supplier Programmable Constant Temperature and Humidity Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Gold_Supplier_Programmable_Constant_Temperature--11372570_11372574.html]]></link><description><![CDATA[min7. Cooling rate: RT ~ -20ºC average 1ºC/min8. Temperature and humidity controller: balance temperature and humidity control system9. Refrigeration system: air-cooled, two-stage, fully sealed com]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[UL746A Tracking Index Test Device]]></title><link><![CDATA[https://pegogroup.en.ec21.com/UL746A_Tracking_Index_Test_Device--11405200_11425193.html]]></link><description><![CDATA[fan automatically draws air when power on, and automatically run for 2 minutes when power off. The front panel is transparent for easy observation of the experimental process. 
Proof Tracking Index (]]></description><pubDate><![CDATA[20210805]]></pubDate></item>
<item>
<title><![CDATA[Ceiling Mounted Ventilation Exhaust Fan]]></title><link><![CDATA[https://futinaswitch.en.ec21.com/Ceiling_Mounted_Ventilation_Exhaust_Fan--11637911_11637922.html]]></link><description><![CDATA[fan
Product name
Ceiling Mounted Ventilation Exhaust Fan
Power
30W-40W
Air Volume
150-210 m³/h
Speed
1200-1500r/min
Lead time
25-45days
Type
Axial Flow Fan
Applicable Industries
Hotels, Garment Shop]]></description><pubDate><![CDATA[20220913]]></pubDate></item>
<item>
<title><![CDATA[Low Temperature Impact Testing Meter]]></title><link><![CDATA[https://lgcs201088.en.ec21.com/Low_Temperature_Impact_Testing_Meter--6692154_6692467.html]]></link><description><![CDATA[min 
0 ℃ ~ -20 ℃ about 1.0 ℃ / min 
-20 ℃ ~ -30 ℃ about 0.8 ℃ / min 
4. Maximum dimension of the external form: 910 × 510 × 920mm (length × width × height) 
5. The effective dimension]]></description><pubDate><![CDATA[20211028]]></pubDate></item>
<item>
<title><![CDATA[TN1058 Programmable Constant Temperature and Humidity Chamber]]></title><link><![CDATA[https://fulfilling.en.ec21.com/TN1058_Programmable_Constant_Temperature_and--5441143_9547151.html]]></link><description><![CDATA[min
Cooling efficiency
＞1℃/min，max 5℃/min
Temp accuracy
0.1 ℃
Temp fluctuation
&amp;plusmn;0.5℃
Temp uniformity
&amp;plusmn;2℃
Humidity fluctuation
&amp;plusmn;3﹪R.H
Humidity uniformity
&amp;plusmn;2]]></description><pubDate><![CDATA[20170530]]></pubDate></item>
<item>
<title><![CDATA[Climatic Testing Machine Manufacturer/Environmental Temperature Humidity Test Chamber]]></title><link><![CDATA[https://annie0423.en.ec21.com/Climatic_Testing_Machine_Manufacturer_Environmental--9938707_9938708.html]]></link><description><![CDATA[min
Heating down:
20&amp;deg;C~ -20&amp;deg;Cwithin 40min
Interior dimension(W&amp;times;D&amp;times;H):
50&amp;times;60&amp;times;50cm
Exterior dimension(W&amp;times;D&amp;times;H):
102&amp;times;170&amp;times;87cm
Interior material:
Stai]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>