<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - phase transformers]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/phase_transformers--2717/1/phase transformers.html]]></link><item>
<title><![CDATA[TTR-I Fully Automatic Three Phase Power Transformer Turns Ratio Test Set]]></title><link><![CDATA[https://cndeltatech.en.ec21.com/TTR_I_Fully_Automatic_Three--11542988_11543002.html]]></link><description><![CDATA[TTR-I Fully Automatic Three Phase Power Transformer Turns Ratio Test Set
Introduction:
TTR-I Transformer Turns Ratio Tester is designed according IEC76-1 and IEC60044. It can be applied to test the t]]></description><pubDate><![CDATA[20220314]]></pubDate></item>
<item>
<title><![CDATA[VC5000A Power Quality Analyzer]]></title><link><![CDATA[https://cqsellbest.en.ec21.com/VC5000A_Power_Quality_Analyzer--11925671_11925688.html]]></link><description><![CDATA[phase current Balance, short-term voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor, displacement power factor, active energy, reactive energy, apparen]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[ACP Electrical Current Transformer Test, CT/PT Analyzer]]></title><link><![CDATA[https://aijiezn.en.ec21.com/ACP_Electrical_Current_Transformer_Test--3533367_11343743.html]]></link><description><![CDATA[Transformer Ratio
Test 
5. Polarity 
6. Ratio difference
measurement 
7. Phase (angle difference)
measurement 
8. Primary Current
Injecting 
9. Withstand Test of
Power Frequency Alternating Current 
]]></description><pubDate><![CDATA[20210224]]></pubDate></item>
<item>
<title><![CDATA[12kV Transformer Capacitance &amp;Tan Delta Tester]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/12kV_Transformer_Capacitance_Tan_Delta--11895397_11895398.html]]></link><description><![CDATA[transformers, transformers, bushings, capacitors, motors, generators, power cables, and other high voltage equipment.
Hengfeng capacitance and tan delta tester
measures the capacitance and dielectric]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[Ponovo PCT200 Series CT and PT Test Set for Current Transformer and PT Reference Testing Functi]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_PCT200_Series_CT_and--11744128_7404184.html]]></link><description><![CDATA[Ponovo PCT200 Series CT/PT Test System
PCT200 series CT/PT test set (CT Analyzer) is a current transformer test equipmentspecially designed for current transformer characteristic test and plus PT ref]]></description><pubDate><![CDATA[20230609]]></pubDate></item>
<item>
<title><![CDATA[Analog Current Panel Meter47X47 Current Meter]]></title><link><![CDATA[https://aoyijenny.en.ec21.com/Analog_Current_Panel_Meter47X47_Current--8875633_8905372.html]]></link><description><![CDATA[Phase Power Factor Meter
Frequency Meter
Class
1.5
1.5
1.5
1.5
1.5
1.5
Measuring Range
1-500mA,1-50A,Attach FL-2 Shunt over 75A Addition
0.5-50A,AttachCurrent Transformer over 75A,Overload 0.5A 5A
1-]]></description><pubDate><![CDATA[20210619]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[Introduction
LVLP series is linear DC power supply uses power frequency transformer AC/DC conversion technology and matured filtering circuit to ensure pure and &amp; stable DC output
As it uses power fr]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[Transformer Variable Ratio of Entire Inspection Test]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/Transformer_Variable_Ratio_of_Entire--10586983_10714599.html]]></link><description><![CDATA[phase PTs, and a Z-shaped group can be selected. X, Y, Z, x, y, z, a ,, b ,, c ,, x ,, y ,, z, is used in verifying the accuracy of the standard transformation PT and the standard three- In addition,]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Manufacturer Variable Frequency Series High Voltage AC Resonant Test System]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Manufacturer_Variable_Frequency_Series_High--10544358_10544744.html]]></link><description><![CDATA[transformers and GIS. The reactor is designed in more than one separately, which not only can meet the test condition requirements for equipments with high voltage and low current, but also for low-v]]></description><pubDate><![CDATA[20170921]]></pubDate></item>
<item>
<title><![CDATA[GF1061 Portable CT PT Analyzer Is Mainly Used for Field or Lab Testing, It Can Finish the Measuremen]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/GF1061_Portable_CT_PT_Analyzer--10658146_10658147.html]]></link><description><![CDATA[transformer ratio error and phase error, Magnetization curve etc. 
It facilitates fast and economical on-site testing and calibration of metering and protection current transformers. Manufacturers of]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[TEKON600 Turns Ratio Meter]]></title><link><![CDATA[https://tekon1.en.ec21.com/TEKON600_Turns_Ratio_Meter--11010564_11012592.html]]></link><description><![CDATA[transformer, CT (Current Transformer) and PT 
(Potential Transformers).
This
model is divided into two: TEKON600-1P (single-phase) and TEKON600-3P
(three-phase). You are able to print out measurement]]></description><pubDate><![CDATA[20201231]]></pubDate></item>

</channel>
</rss>