<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - resistant to high voltage]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/resistant_to_high_voltage--2717/1/resistant to high voltage.html]]></link><item>
<title><![CDATA[Fluke 87V Industrial Multimeter 2025]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_87V_Industrial_Multimeter_2025--11790575_11793411.html]]></link><description><![CDATA[to + 55 °CStorage temperature–40 °C to + 60 °CHumidity (without condensation)0% – 90% (0 °C – 35 °C)0% – 70% (35 °C – 55 °C)Operating Altitude2000 mSafety SpecificationsOvervoltage c]]></description><pubDate><![CDATA[20250321]]></pubDate></item>
<item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[to ensure the safety of the operator.
★Discharge protection: high voltage discharge for 2 seconds, stop the high voltage output automatically;
★On-resistance: On-resistance range :0-10000, on-res]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke 3540 FC KIT Three-Phase Power Monitor]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_3540_FC_KIT_Three--12045274_12045343.html]]></link><description><![CDATA[high leg delta, 3-Φ delta balanced. Currents only (load studies)Voltage InputsNumber of inputs: 4 (3 phases and neutral)
Maximum input voltage: 1000 Vrms (1700 Vpk) phase to neutralInput Impedance10]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[YH810 Thermal Signal Calibrator]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH810_Thermal_Signal_Calibrator--12022555_12022556.html]]></link><description><![CDATA[voltage display function;
◆Equipped with simulated two-wire transmitter current loop output function;
◆Provide independent 24V power supply;
◆Equipped with RS232 interface, can be equipped with]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[GF018A Clamp Type Multimeter Calibrator]]></title><link><![CDATA[https://gfuvegroup.en.ec21.com/GF018A_Clamp_Type_Multimeter_Calibrator--11546876_11999025.html]]></link><description><![CDATA[High precision AC/DC voltage source &amp; current source;
■ Because of light weight, this device is more suitable for field use;
■ With RS-232 interface, this calibrator is controlled by PC software(]]></description><pubDate><![CDATA[20240905]]></pubDate></item>
<item>
<title><![CDATA[EMCEE Model 1154 Precision Conductivity Meter]]></title><link><![CDATA[https://xmjielian.en.ec21.com/EMCEE_Model_1154_Precision_Conductivity--11982130_11982350.html]]></link><description><![CDATA[to several thousand. “Rest” conductivity is the electrical conductivity at the initial instant of current measurement after a dc voltage is impressed between electrodes (reciprocal of the resista]]></description><pubDate><![CDATA[20240813]]></pubDate></item>
<item>
<title><![CDATA[Power Cord Plug Tester]]></title><link><![CDATA[https://satatec.en.ec21.com/Power_Cord_Plug_Tester--7687564_7687565.html]]></link><description><![CDATA[to UL, VDE, BSI, SAA, T-MARK, KS, IRAM, CCC standards
Range: It is used for testing the Continuity &amp; Polarity, Ground resistance, insulation, High Voltage, Exposed copper (conductor), and relative le]]></description><pubDate><![CDATA[20240711]]></pubDate></item>
<item>
<title><![CDATA[Professional FI Manufacturer for Power Distribution Network Intellegent Wireless Office System]]></title><link><![CDATA[https://snova17.en.ec21.com/Professional_FI_Manufacturer_for_Power--10349843_10349891.html]]></link><description><![CDATA[to judge the fault on the power lines according to the change of current, grounding fault, and the fault state, real time current, battery voltage and
other information. is uploaded to the remote ser]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Wire Harnesses/Cables Testing Bench Top(Table) for Automotive]]></title><link><![CDATA[https://shcleanknow4567.en.ec21.com/High_Voltage_Wire_Harnesses_Cables--11923899_11923921.html]]></link><description><![CDATA[High Voltage Testing system has been specially developed for testing of high-voltage and data sensor cables. It conforms to international standards and is widely used in the cable assembly of automot]]></description><pubDate><![CDATA[20240412]]></pubDate></item>
<item>
<title><![CDATA[Programmable Touch Screen Desktop Environmental Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Programmable_Touch_Screen_Desktop_Environmental--11825687_11825716.html]]></link><description><![CDATA[Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials
Cooling System
Wind cooling
Protection Devices
Fuse-free switch, overloading protection switch fo]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Multi-channel Multi-function Intelligent Temperature and Humidity Itinerant Detector]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Multi_channel_Multi_function_Intelligent--11689589_11689607.html]]></link><description><![CDATA[voltage, resistance, temperature, humidity and other data formats display, storage and output
▶ Provide encryption algorithm support, can encrypt data files, effectively improve security
▶ Suppor]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Metal Oxide Surge Arrester Leakage Current Analyzer HFYH-8001B]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Metal_Oxide_Surge_Arrester_Leakage--11895397_11895400.html]]></link><description><![CDATA[to establish that your surge arresters are healthy and the transformer is still protected.
It can measure the full current, resistive current and harmonics, power frequency reference voltage and harm]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[Bruker Tracer 5i Handheld XRF Spectrometer]]></title><link><![CDATA[https://thexrfstore.en.ec21.com/Bruker_Tracer_5i_Handheld_XRF--11822199_11822200.html]]></link><description><![CDATA[Russian, SpanishMEX, SpanishSPN, Thai, TurkishOperating environment: -10°C to +50°C (+14°F to 122°F); IP54 dust and splash resistant; Altitude: 2,500 m (8,200 ft)Certification: CE, FCC part 15
]]></description><pubDate><![CDATA[20230720]]></pubDate></item>
<item>
<title><![CDATA[Medium Voltage Surge Arresters]]></title><link><![CDATA[https://yfpower.en.ec21.com/Medium_Voltage_Surge_Arresters--11836088_11836092.html]]></link><description><![CDATA[voltage surges by providing a low-resistance path to the earth, thus absorbing and repelling the energy away from the equipment. This protects the equipment from electrical stress, high-voltage break]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[3kW/3.5kW/4kW/5kW/6kW/7kW AC/DC Load Bank for Data Center Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/3kW_3.5kW_4kW_5kW_6kW--11807084_11807114.html]]></link><description><![CDATA[to meet different requirement of heat dissipation capacity11: Wire color/length: customized.12: Packing: paper carton + wrapping filmSPECIFICATION 
Power(kW)Voltage(V)Frequency(Hz)Carton HightMin. St]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[Petroleum Products Density Tester]]></title><link><![CDATA[https://precisionbe.en.ec21.com/Petroleum_Products_Density_Tester--11718430_11856618.html]]></link><description><![CDATA[to operate;
3. Low-noise magnetic pump cross-circulation structure;
4. 2 unit test structure, low temperature bath with lighting;
5. High-power solid-state relay control output, no voltage leakage;
6]]></description><pubDate><![CDATA[20231019]]></pubDate></item>
<item>
<title><![CDATA[Surge Generator]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Surge_Generator--11882688_11882701.html]]></link><description><![CDATA[voltage generator, combined surge voltage and current generator) . 
How does a surge generator work?The SG61000-5 surge generator provides a common basis for evaluating the resistance of power cords ]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Futina Metal Electrical Power Distribution Box B Series]]></title><link><![CDATA[https://futinaswitch.en.ec21.com/Futina_Metal_Electrical_Power_Distribution--11637911_11862326.html]]></link><description><![CDATA[voltage 220V/380V, and acted to install the modular combination equipment.
Specification of Metal Electrical Power Distribution Box B Series
Product name
Flush mounted surface mounted MCB electrical ]]></description><pubDate><![CDATA[20231103]]></pubDate></item>
<item>
<title><![CDATA[100V 120A 18650 Finished Battery Pack 100v200a 300a Tester for Lithium Battery Pack Assembly Line]]></title><link><![CDATA[https://aitop2018.en.ec21.com/100V_120A_18650_Finished_Battery--11585406_11639412.html]]></link><description><![CDATA[voltage, AC internal resistance, discharge test, discharge over-current test, short circuit protection test, charging test and charging protection test. The system adopts 32-bit ARM processor and 16 ]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Lightning Surge Generator]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Voltage_Lightning_Surge_Generator--11812738_11812759.html]]></link><description><![CDATA[higher voltage Surge Generator can be designed according to your requirement.
Due to the high voltage risk during the Surge Test, we suggest you to option choose the Protect Device for Surge Test PD-]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[ESS, EV Battery Quality Analyzer]]></title><link><![CDATA[https://tekon1.en.ec21.com/ESS_EV_Battery_Quality_Analyzer--11010564_11156929.html]]></link><description><![CDATA[high-voltage battery packs, such as ESS, EV, HEV and PV as well as UPS.
[Feature]
• Measures internal resistance of 1500V max of batteries
• Measures voltages at battery (DC1500V)
• Measures vo]]></description><pubDate><![CDATA[20201231]]></pubDate></item>
<item>
<title><![CDATA[DC Brushless Fan Motor Dynamometer]]></title><link><![CDATA[https://hzchangniu.en.ec21.com/DC_Brushless_Fan_Motor_Dynamometer--11882582_11882988.html]]></link><description><![CDATA[voltage, insulation, inter-turn, resistance (including three-phase
resistance balance), inductance, magnetic rotation, reverse embedding, Hall/FG
waveform (optional), phase sequence (optional), etc.,]]></description><pubDate><![CDATA[20240222]]></pubDate></item>
<item>
<title><![CDATA[VICIMETER Megga Resistance Testing VC60B+ Insulation Tester]]></title><link><![CDATA[https://vicimeter.en.ec21.com/VICIMETER_Megga_Resistance_Testing_VC60B--11555545_8944178.html]]></link><description><![CDATA[to use
High voltage and short circuit input alarm
Hold function and test lock.
Specifications:
Basic function
Range
Basic accuracy
Resolution
Insulation resistance
250V±10% test voltage
0~200MΩ
±(]]></description><pubDate><![CDATA[20220419]]></pubDate></item>
<item>
<title><![CDATA[Automatic Safety Test System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Automatic_Safety_Test_System--9657760_11802784.html]]></link><description><![CDATA[high voltage output is a negative voltage, and the ground is a positive. When testing capacitance, there is a charging process when voltage is applied to both ends of the capacitor. At this time, the]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[NAVLF Ultra-low Frequency High Voltage Generator]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/NAVLF_Ultra_low_Frequency_High--10586964_10725175.html]]></link><description><![CDATA[high-voltage part with a spark discharge, heavy equipment, and the two and four-quadrants of sine wave, need large power high voltage resistance to discharge and sharp, the total total power consumpt]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Made in China HZ-3120A Automatic Transformer DC Winding Resistance Tester]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Made_in_China_HZ_3120A--10544358_10544703.html]]></link><description><![CDATA[resistance tester,DC high voltage generator,testing transformer,insulating oil tester, like transformer oil dielectric tester (BDV tester), transformer loss tester, transformer oil acid tester, flash]]></description><pubDate><![CDATA[20210426]]></pubDate></item>
<item>
<title><![CDATA[GF1061 Portable CT PT Analyzer Is Mainly Used for Field or Lab Testing, It Can Finish the Measuremen]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/GF1061_Portable_CT_PT_Analyzer--10658146_10658147.html]]></link><description><![CDATA[high voltage transformers and switchgear also use the CT Analyzer for tests during development and production.
Application
1. Measurement type current transformer 
2. Protection type current transfor]]></description><pubDate><![CDATA[20180509]]></pubDate></item>
<item>
<title><![CDATA[Digit LED Tube Voltage Current Power Meter Display HN-24SX]]></title><link><![CDATA[https://aoyijenny.en.ec21.com/Digit_LED_Tube_Voltage_Current--8875633_8878842.html]]></link><description><![CDATA[resistance pt100 type 0 to 650℃.
Digit LED tube Voltage current power meter display HN-24SX
Technical Parameters:
Measure Precision: ±0.5% ±1Word
Working power supply: AC220V(85%～110%) 50/60Hz ]]></description><pubDate><![CDATA[20210619]]></pubDate></item>
<item>
<title><![CDATA[DX Hall Effect Measurement System for Laboratory Studying Electrical Properties of Semiconductor]]></title><link><![CDATA[https://jackietsui.en.ec21.com/DX_Hall_Effect_Measurement_System--8508233_11795103.html]]></link><description><![CDATA[voltage.
The experimental results of the Dexinmag series Hall effect test systems are automatically calculated by the software at the same time, such as Bulk Carrier Concentration, Sheet Carrier Conc]]></description><pubDate><![CDATA[20230522]]></pubDate></item>
<item>
<title><![CDATA[Electric Motor Stator Testing Equipment for Production Line]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/Electric_Motor_Stator_Testing_Equipment--11085938_11085939.html]]></link><description><![CDATA[resistance alarm setting range
Max：0～500MΩ；Min：1～500MΩ 
test time range/resolution
0.5～999.9s 0.1s/step
Surge ： apply impulse high
voltage to windings, and compare the oscillation gra]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Hipot Tester 0.05 - 5kV AC, 0.05 - 6kV DC]]></title><link><![CDATA[https://testron.en.ec21.com/Hipot_Tester_0.05_5kV_AC--10983225_10983230.html]]></link><description><![CDATA[voltage tester is mainly used to detect the safety performance of instruments,
equipment and components 
Features
HPT-9901 Single channel high voltage tester.
HPT-9904 4-channel high-voltage scanning]]></description><pubDate><![CDATA[20190719]]></pubDate></item>
<item>
<title><![CDATA[ZXUD - 40 Digital Truecolor Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ndtchina.en.ec21.com/ZXUD_40_Digital_Truecolor_Ultrasonic--6581053_6161468.html]]></link><description><![CDATA[voltage square pulse generator set and multi-pole damping set, making the probe and the detector match up.
Optimizing pulse repetition frequency control, good dynamic effect of echo pulse, no lag, me]]></description><pubDate><![CDATA[20140520]]></pubDate></item>

</channel>
</rss>