<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - single mode]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/single_mode--2717/1/single mode.html]]></link><item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[single (double) pole electric coagulation connecting wires and surgical instrument leads with power supply for endoscopes, laparoscopes, single (double) pole electric knives and electric coagulation ]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO 60 Hz, 640 X 480 High-Performance IR Thermal Camera]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_TI480_PRO_60_Hz--11561118_11932301.html]]></link><description><![CDATA[single session in a time series graph
ShareLive video call: View live tool measurements, video and audio to collaborate in real time with your entire team, without leaving the field
Fluke Cloud stora]]></description><pubDate><![CDATA[20250129]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[Single. Time.Laser distance meterYes, calculates distance to the target for precisely focused images and displays distance on screenAdvanced manual focusYesTouchscreen display (capacitive)5.7 inch (1]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[New Fluke TI480 PRO 60HZ Thermal Imager]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/New_Fluke_TI480_PRO_60HZ--11927627_11927630.html]]></link><description><![CDATA[Single. TimeWarranty2 YEARSWarranty DetailsTwo-years (standard), extended warranties are availableSafety ApprovalCSA, ULInterfaces I/OBluetooth, Wifi, HDMIStorageInternal Memory, Micro SD, USB Flash ]]></description><pubDate><![CDATA[20250104]]></pubDate></item>
<item>
<title><![CDATA[Automatic Front End Measure System]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Automatic_Front_End_Measure_System--12024209_12033092.html]]></link><description><![CDATA[mode, with touch screen and PLC control.
l Can be equipped with single conveyor lane (three lanes by custom option).
l Fully automatic measurement, free up the testing time for inspectors and avoid m]]></description><pubDate><![CDATA[20241225]]></pubDate></item>
<item>
<title><![CDATA[Construction Laser Level]]></title><link><![CDATA[https://holo1.en.ec21.com/Construction_Laser_Level--11967590_11967628.html]]></link><description><![CDATA[This construction laser level utilizes a laser beam to provide a 
horizontal reference line, which is essential for a variety of tasks on 
construction sites.
Single measurement, continuous measureme]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[YH800F Portable Fully Automatic Pressure Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH800F_Portable_Fully_Automatic_Pressure--12022422_12022441.html]]></link><description><![CDATA[single point voltage stabilization time, can be edited. The system automatically divides the range into equal parts, and the pressure rise and fall cycles automatically without manual intervention;
]]></description><pubDate><![CDATA[20241105]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Ultrasonic_Flaw_Detector--11973711_11973715.html]]></link><description><![CDATA[Mode
Single、Dual、Thru
Reject
0~80%
Pulse Displacement (μs)
-20 - +3400
Zero (μs)
0.0 - 99.99
Lithium Battery
5600mAh, 7.4v
Connector Type
BNC or Lemo 01
Operating Temperature (℃)
-20 - +50
H]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-2 Electrostatic Discharge Generator with 20KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_2_Electrostatic_Discharge--11944039_11946383.html]]></link><description><![CDATA[mode
Single,counting,20pps,other
Discharge interval:
0.05~99.99s
Numbers of discharge:
1~9999
Energy storage capacitance:
150pF ±10％(replaceable)
Discharge resistor:
330Ω ±10％（replaceable)
W]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[F2 Platform Ultrasonic Quality Inspection Platform]]></title><link><![CDATA[https://shnde.en.ec21.com/F2_Platform_Ultrasonic_Quality_Inspection--11943775_11943794.html]]></link><description><![CDATA[Single-frame and continuous live data acquisition modes 
The infrastructure solutions supplied with the platform include: planning and managing the routine inspections, data synchronization, reportin]]></description><pubDate><![CDATA[20240528]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[Modes Supported 
Point to Point operation , the most commonly used mode, connects the 754 to a single HART device in a 4-20 mA loop.In Multi-Drop mode , several HART instruments can be bussed togethe]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD40 Zero-distance Drop Test System]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD40_Zero_distance_Drop_Test--11098426_11099460.html]]></link><description><![CDATA[single-track or dual-track
lifting method, and the height can be adjusted arbitrarily;
l 
It can clamp and drop the test
specimen in different directions such as edges, faces and angles;
l 
The testi]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[100kW/200kW/500kW/800kW/1000kW/1200kW/2000kW AC Dummy Resistive Load Bank for Generator Load Test]]></title><link><![CDATA[https://rataloadbank.en.ec21.com/100kW_200kW_500kW_800kW_1000kW--11807078_11807097.html]]></link><description><![CDATA[100kW/200kW/500kW/800kW/1000kW/1200kW/2000kW AC Dummy Resistive Load Bank for Generator Load Test
Following is 1000kW load bank for reference.Our resistive load bank rangeis: 3kW~10000kW for single l]]></description><pubDate><![CDATA[20230615]]></pubDate></item>
<item>
<title><![CDATA[LVLP Linear DC Power Supply]]></title><link><![CDATA[https://idealtek.en.ec21.com/LVLP_Linear_DC_Power_Supply--9605857_9605884.html]]></link><description><![CDATA[Single-phase 220Vac, 50 Hz&amp;plusmn;10% (&amp;le;7KW) 
Three-phase 380Vac, 50Hz&amp;plusmn;10% (&gt;7kw) 
Output: DC C.C. and/or C.V. 
Max output: As requirements
2. Accuracy (C.V.)
Line regulation: &amp;le;0.1% Of t]]></description><pubDate><![CDATA[20151002]]></pubDate></item>
<item>
<title><![CDATA[P6000 Series Test Modules]]></title><link><![CDATA[https://xinertel.en.ec21.com/P6000_Series_Test_Modules--10761704_10761725.html]]></link><description><![CDATA[mode
Continuous, Single burst, Multi burst, Time burst and Serialized
Software Support
TeleExplorer test system, Test suit of RFC 2544/RFC 2889/RFC3918, TeleATT – automated Test system for product ]]></description><pubDate><![CDATA[20190419]]></pubDate></item>
<item>
<title><![CDATA[Electrical Asphalt/Soil Non-nuclear Density Gauge for Civil Engineering]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/Electrical_Asphalt_Soil_Non_nuclear--10976325_10976334.html]]></link><description><![CDATA[modes : single-point mode, continuous mode, the average model , segregation patterns
You can store 200 sets of measurement data
Automatic calculation of the average density , degree of compaction and]]></description><pubDate><![CDATA[20230530]]></pubDate></item>
<item>
<title><![CDATA[DC Motor Armature Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/DC_Motor_Armature_Testing_Equipment--11085938_11085990.html]]></link><description><![CDATA[single or dual insulation armature
Voltage precision 
≤±2.5% +3 words
Leakage current range
0-5/10/20mA
Leakage current precision 
≤±2.5% measuring range +3 words
Surge 
Voltage range
0-3000V
V]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Furniture Mechanics Comprehensive Test Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Hot_Sale_Furniture_Mechanics_Comprehensive--11365007_11365011.html]]></link><description><![CDATA[single or multiple reciprocating test, can set two groups of cooperative action, reciprocating test. Each channel shall be operated through the reference synchronization time to ensure the synchroniz]]></description><pubDate><![CDATA[20210416]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-5 Lightning Surge Generator]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61000_4_5_Lightning_Surge--11421920_11421956.html]]></link><description><![CDATA[mode
Synchronization,asynchronization
Inject phase
Freely set at 0－360°，resolution:1°
Trigger mode
Auto or manual, single
Surge times
1-9999 times
Memories
1000 groups
Surge interval
20-9999s
A]]></description><pubDate><![CDATA[20210729]]></pubDate></item>
<item>
<title><![CDATA[Multi-channel Multi-function Intelligent Temperature and Humidity Itinerant Detector]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Multi_channel_Multi_function_Intelligent--11689589_11689607.html]]></link><description><![CDATA[single point, piecewise linear or least squares
▶ Support voltage, resistance, temperature, humidity and other data formats display, storage and output
▶ Provide encryption algorithm support, can]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Automatic Capacitance and Dissipation Factor Test Set]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Automatic_Capacitance_and_Dissipation_Factor--11895397_11895406.html]]></link><description><![CDATA[single test
5. Reserve the interface for external standard capacitor and external transformer
6. Internal memory with time/date stamp
7. Internalthermal printer
8. USB port for export test data to US]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[Computer Controlled Electronic Universal Testing Machine]]></title><link><![CDATA[https://shiyanji.en.ec21.com/Computer_Controlled_Electronic_Universal_Testing--4048548_4096477.html]]></link><description><![CDATA[WDW-2/5 Microcomputer Controlled Electronic Universal Testing Machine 
(Single Arm type with Large Deformation Extensometer)
1. Main function &amp; applicable scope:
This series machine is mainly used to]]></description><pubDate><![CDATA[20120515]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Nortec 600D Eddy Current Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/Used_Olympus_Nortec_600D_Eddy--11801594_11801596.html]]></link><description><![CDATA[modes, the full-screen mode really comes in handy when reading signals over an extended period of time.
Depending on your NORTEC 600 model, you can choose between the following displays:
single imped]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[100k - 10T Micro Signal Type Tester Resistance Capacitance and Inductance Tester]]></title><link><![CDATA[https://techmizetest.en.ec21.com/100k_10T_Micro_Signal_Type--11890824_11890825.html]]></link><description><![CDATA[single pulse signal input interface, making it easy for pipeline operation. The quipped communication interface can achieve the off-site operations of all functions of the instrument through microcom]]></description><pubDate><![CDATA[20240119]]></pubDate></item>
<item>
<title><![CDATA[Dissolution Tester Device]]></title><link><![CDATA[https://jiahang1.en.ec21.com/Dissolution_Tester_Device--11600339_11853671.html]]></link><description><![CDATA[mode: synchronous administration.• Lifting system: Bamboo-style single-column lift.• Rights management: three levels, seven users.• Audit trail: 128 entries × 366 days.• Working noise: &lt;60db]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[V-Sorb 4800P Surface Area and Porosimtery Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/V_Sorb_4800P_Surface_Area--7277224_7277115.html]]></link><description><![CDATA[Single and multi-point BET (Brunauer-Emmett-Teller) surface area analysis, T-plot external surface area, True density analysis, BJH (Barrett-Joyner-Halenda) pore size, BJH (Barrett-Joyner-Halenda) to]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Window Tint Meter WTM-1100 Light Transmission Meter]]></title><link><![CDATA[https://105landtek.en.ec21.com/Hot_Sale_Window_Tint_Meter--11797706_11797708.html]]></link><description><![CDATA[Mode:Single / Continuous
Operating conditions:Temperature: 0 ~ 50 ℃ Humidity: &lt; 90 %
Power Supply:4 x 1.5 V AAA Size (UM-4) Battery
Dimensions:Unit: 126 x 65 x 27 mm (5.0 x 2.6 x 1.1 inch)
Sensor: ]]></description><pubDate><![CDATA[20231125]]></pubDate></item>
<item>
<title><![CDATA[Programmable Control Temperature Humidity Tester]]></title><link><![CDATA[https://annie0423.en.ec21.com/Programmable_Control_Temperature_Humidity_Tester--9938678_9938741.html]]></link><description><![CDATA[single stage refrigeration system.
Display:
LCD
Safety devices:
No fuse breaker refrigerator over load relay, Refrigeration High pressure Switch, Over Temp, Protector, Protection relay, Protection fu]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>