<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - test probe a]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/test_probe_a--2717/1/test probe a.html]]></link><item>
<title><![CDATA[Fluke 87V Industrial Multimeter 2025]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_87V_Industrial_Multimeter_2025--11790575_11793411.html]]></link><description><![CDATA[in the box:
Fluke 87V Industrial MultimeterTL75 Test Leads (TL175 Eur)AC175 Alligator ClipsHolster with tilt-leg, test lead storage80BK Temperature Probe9V Battery (Installed)
Specifications: Fluke 8]]></description><pubDate><![CDATA[20250321]]></pubDate></item>
<item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[test results, leakage times and other information.
★Warranty: The equipment is guaranteed for 2 years. Maintenance once a year, lifetime maintenance service.
★Size: 225mm(L)X90mm(W)X40mm(H);
Equi]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke 87-5 CAL Industrial True-RMS Multimeter with Calibration Certificate, 1000 V, 10 A]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_87_5_CAL_Industrial--12045274_12045351.html]]></link><description><![CDATA[In The Box
87V Industrial MultimeterTL75 Test LeadsAC175 Alligator ClipsHolster9V Battery (Installed)80BK-A Temperature Probe]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke 753 Documenting Process Calibrator]]></title><link><![CDATA[https://linkssurvey.en.ec21.com/Fluke_753_Documenting_Process_Calibrator--12030345_12045401.html]]></link><description><![CDATA[report and dataThree sets of TP220 test probes with three sets of “extended tooth alligator clipsTwo sets AC280 hook clipsC799 Soft Field CaseUSB communication cable: 6 ft. type A to type mini-B]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Hall Effect Thickness Gauge(Magnetic Bottle Thickness Gauge)]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Hall_Effect_Thickness_Gauge_Magnetic--12024209_12027724.html]]></link><description><![CDATA[test sample is over 0.160″/4 mm, accessories are optional by order.)
Advantages:
● With a more wearable probe
● More sizes of magnetic balls: 5.00mm and 7.00mm
● Larger measuring range: up to]]></description><pubDate><![CDATA[20241127]]></pubDate></item>
<item>
<title><![CDATA[YH701 Temperature and Humidity Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH701_Temperature_and_Humidity_Calibration--12022540_12022544.html]]></link><description><![CDATA[a well-designed control system and fast cooling speed.
◆Temperature and humidity control sensor: High quality temperature and humidity probe has high measurement range and accuracy.
◆Appearance: ]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator with HART Communication]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11561118_11561429.html]]></link><description><![CDATA[sets) TP220 test probes(3 sets) &quot;extended tooth&quot; alligator clips(2 sets) AC280 hook clipsC799 Soft Field CaseUSB communication cable, Fluke 754HHC HART communications cableQuick Reference Guide]]></description><pubDate><![CDATA[20240921]]></pubDate></item>
<item>
<title><![CDATA[EMCEE Model 1153 Digital Conductivity Meter]]></title><link><![CDATA[https://xmjielian.en.ec21.com/EMCEE_Model_1153_Digital_Conductivity--11982130_11982346.html]]></link><description><![CDATA[a stainless steel probe. The probe, which is similar to a capacitor having concentric electrodes, is immersed in the fluid up to the set of holes closest to the electronics assembly. During the read ]]></description><pubDate><![CDATA[20240813]]></pubDate></item>
<item>
<title><![CDATA[Multi Channel Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Multi_Channel_Ultrasonic_Flaw_Detector--11973711_11973720.html]]></link><description><![CDATA[Multi Channel Ultrasonic Flaw Detector
Introduction
The instrument incorporates many advanced signal processing features including a 15MHz RF bandwidth to permit testing of thin materials, narrowband]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[NDJ-8T Lab Digital Rotating Viscosity Meter Viscosimeter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_8T_Lab_Digital_Rotating--11144324_11144457.html]]></link><description><![CDATA[probe interface (requires optional temperature probe)
Automatic scanning function
Automatically scan and recommend a priority combination of rotor and speed
Display measurement range
Automatic displa]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Gear Measuring Machine for Worm Wheel Rotary Table,Bevel Gear,]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Gear_Measuring_Machine_for_Worm--11944568_11945231.html]]></link><description><![CDATA[probes;
Having a complete set of independent intellectual property rights, multiple patented technologies, instrument functions, software configurations, and flexibility and diversity; 
The introduct]]></description><pubDate><![CDATA[20240531]]></pubDate></item>
<item>
<title><![CDATA[WIKA Instrument PASCAL100IS-4IPS-2IN-2OUT-EPS-PR]]></title><link><![CDATA[https://moracalibration1.en.ec21.com/WIKA_Instrument_PASCAL100IS_4IPS_2IN--11937385_11937386.html]]></link><description><![CDATA[testing and calibration of industrial measuring instruments. The typical application is the calibration of pressure transmitters, temperature transmitters, pressure gauges, temperature probes and oth]]></description><pubDate><![CDATA[20240515]]></pubDate></item>
<item>
<title><![CDATA[Fluke 1587 FC Advanced Electrical Troubleshooting Kit]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_1587_FC_Advanced_Electrical--11927627_11927693.html]]></link><description><![CDATA[a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.Korea (KCC)Class A Equipment (Industrial Broadcasting &amp; Communica]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[a separate communicator.
Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instrumentsSource/simulate volts, mA, thermocouples, RTDs, frequency, ohms]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Omniscan MX2 PA Flaw Detector]]></title><link><![CDATA[https://tol22man.en.ec21.com/Used_Olympus_Omniscan_MX2_PA--11836190_11836198.html]]></link><description><![CDATA[test instrument produced by Olympus to date, with thousands of units in use throughout the world.
Olympus now offers a new PA module with TOFD, a new UT module, as well as new software programs (NDT ]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[ICONE2]]></title><link><![CDATA[https://kobistq.en.ec21.com/ICONE2--1_11135288.html]]></link><description><![CDATA[testing of items (e.g. furniture) has been possible by burning these articles and measuring the evolved heat using a technique called oxygen depletion calorimetry. In the early 1980&apos;s workers at NIST]]></description><pubDate><![CDATA[20200511]]></pubDate></item>
<item>
<title><![CDATA[NEW Digital Handheld Salt Tester DMT-20]]></title><link><![CDATA[https://dymeter.en.ec21.com/NEW_Digital_Handheld_Salt_Tester--1223564_3312029.html]]></link><description><![CDATA[= &quot;NEW&quot; Digital Handheld Salt Tester(DMT-20) = : This tester is a dual purpose SALT with Temperature.
Mode
Shows salt concentration in food as a percentage.
It helps you monitor your daily salt intak]]></description><pubDate><![CDATA[20180303]]></pubDate></item>
<item>
<title><![CDATA[WASP-XM-R-SF6 Pump-priming Portable SF6 Gas Detector]]></title><link><![CDATA[https://mary00882009.en.ec21.com/WASP_XM_R_SF6_Pump--4088884_4088885.html]]></link><description><![CDATA[test record function, can store a month&amp;#39;s measurement data and instrument or computer can view the data; 
■ With alarm recording function, you can record the last four times the alarm time and ]]></description><pubDate><![CDATA[20170411]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[tested according to MIL-STD-810G 516.6Ultrasound SpecificationsConnectors: 1 Phased Array connector: Olympus PA connectorConnectors: 2 UT connectors: LEMO 00Number of focal laws: 256Probe recognition]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[Surge Generator]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Surge_Generator--11882688_11882701.html]]></link><description><![CDATA[test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and current generator) . 
How does a surge generator work?The SG61000-5 surge generator provi]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[V-Sorb 2800TP Surface Area and Porosimtery Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/V_Sorb_2800TP_Surface_Area--7277224_7277091.html]]></link><description><![CDATA[testing. It equipped with our multi pioneered technologies these make its performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a lea]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[NI ELVIS II Application Modules]]></title><link><![CDATA[https://iegieg.en.ec21.com/NI_ELVIS_II_Application_Modules--7052123_7052944.html]]></link><description><![CDATA[probe using Multisim to test the performance of the designed circuits.
It is equipped with 12 integrated instruments including a meter oscilloscope, digital multimedia, power supplier, and a function]]></description><pubDate><![CDATA[20121231]]></pubDate></item>
<item>
<title><![CDATA[Humidity Chamber Generator Humidity Sensor Probe Calibration Hygrometer Test Calibrator]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Humidity_Chamber_Generator_Humidity_Sensor--11689458_11689468.html]]></link><description><![CDATA[probes
* Calibrate (3-5) block size digital temperature and humidity meter simultaneously
* The test chamber provides temperature uniformity within 0.1℃℃ in a full range of 5℃~50
* Design of ex]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Lamp Start, Run-up Time and Flicker Test System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Lamp_Start_Run_up_Time--9657760_11802787.html]]></link><description><![CDATA[LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer – Flicker Tester is equipped with Class A fast photometric probe, so the sampling speed is up to 100kHz. It fully meets the requirement ]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[ETG12N1 Eddy Current Digital Paint Thickness Gauge]]></title><link><![CDATA[https://mikrometry.en.ec21.com/ETG12N1_Eddy_Current_Digital_Paint--11395794_11403080.html]]></link><description><![CDATA[Mikrometry Instrument Limited is testing and measuring instruments companies
of height gauge, force and torque measurement products, force gauge, digital torque gauge, paint gauge for cars
, cap torq]]></description><pubDate><![CDATA[20210621]]></pubDate></item>
<item>
<title><![CDATA[New Olympus BondMaster 600 Multimode Bond Tester]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_BondMaster_600_Multimode--11801594_11801602.html]]></link><description><![CDATA[Performance through Intuitive OperationThe BondMaster® 600 delivers a powerful combination of multiple mode bond testing software and highly advanced digital electronics, providing consistently cris]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Nirun Cone Plate Viscometerfor Sale]]></title><link><![CDATA[https://kobebean24.en.ec21.com/Nirun_Cone_Plate_Viscometerfor_Sale--11076331_11076337.html]]></link><description><![CDATA[testing
18.Sound alarm when beyond measurement range
19.Linear calibration by a computer
20.Power supply:100V-240V,powerful anti-interference
Source: https://www.nirunviscometer.com/prolist_t61.html
]]></description><pubDate><![CDATA[20200310]]></pubDate></item>
<item>
<title><![CDATA[100V 120A 18650 Finished Battery Pack 100v200a 300a Tester for Lithium Battery Pack Assembly Line]]></title><link><![CDATA[https://aitop2018.en.ec21.com/100V_120A_18650_Finished_Battery--11585406_11639412.html]]></link><description><![CDATA[100V 120A 18650 Finished Battery Pack Comprehensive Tester For Lithium Battery Pack Assembly Features The comprehensive test equipment for finished battery is a fast and accurate device for testing t]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Lightning Surge Generator]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Voltage_Lightning_Surge_Generator--11812738_11812759.html]]></link><description><![CDATA[test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and current generator) . 
How does a surge generator work?The SG61000-5 surge generator provi]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[SPT for Soil Investigation Tianpeng 63.5kg CN;HEB 10kg 20kg 30kg Petrol Engine]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/SPT_for_Soil_Investigation_Tianpeng--10975742_11481264.html]]></link><description><![CDATA[tests, compaction tests and for soil sampling. Dynamic probing standards DPL (10kg), DPM (30kg), DPH (50kg), DPSH (63.5kg) as well as SPT can be carried out.
Drop height can be varied between 500 and]]></description><pubDate><![CDATA[20230613]]></pubDate></item>
<item>
<title><![CDATA[Electric Motor Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/Electric_Motor_Testing_Equipment--11085938_11085967.html]]></link><description><![CDATA[test time range/resolution
0.5～999s 
0.1s/step
temperature compensation function
Yes
temperature probe/range
DS18b20 -10.0℃~+50.0℃
precision
±0.5°C（range: -10℃~+50℃）
Direction of rota]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Programmable Anti-yellowing Resistance Corrosion Tester]]></title><link><![CDATA[https://annie0423.en.ec21.com/Programmable_Anti_yellowing_Resistance_Corrosion--9938796_9938804.html]]></link><description><![CDATA[test machine is applicable for the sunlight resistant test of nonmetallic materials and aging test of artificial light sources. A variety of industrial products can make the reliability test, and thi]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>