<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - test probe]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/test_probe--2717/1/test probe.html]]></link><item>
<title><![CDATA[Humidity Chamber Generator Humidity Sensor Probe Calibration Hygrometer Test Calibrator]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Humidity_Chamber_Generator_Humidity_Sensor--11689458_11689468.html]]></link><description><![CDATA[Test chamber space up to (3~5) times that of similar products, providing more efficient test conditions
* The test chamber can accommodate various types of in-put cold-mirror-viewer probes for compar]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Fluke 87V Industrial Multimeter 2025]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_87V_Industrial_Multimeter_2025--11790575_11793411.html]]></link><description><![CDATA[in the box:
Fluke 87V Industrial MultimeterTL75 Test Leads (TL175 Eur)AC175 Alligator ClipsHolster with tilt-leg, test lead storage80BK Temperature Probe9V Battery (Installed)
Specifications: Fluke 8]]></description><pubDate><![CDATA[20250321]]></pubDate></item>
<item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[probe tool to the detected facility）
★Voltage regulation: no gear type voltage regulation, 0~5000V adjustable, to meet the detection of peak voltage conditions of charged equipment;
★LCD screen]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke 87-5 CAL Industrial True-RMS Multimeter with Calibration Certificate, 1000 V, 10 A]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_87_5_CAL_Industrial--12045274_12045351.html]]></link><description><![CDATA[In The Box
87V Industrial MultimeterTL75 Test LeadsAC175 Alligator ClipsHolster9V Battery (Installed)80BK-A Temperature Probe]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke 753 Documenting Process Calibrator]]></title><link><![CDATA[https://linkssurvey.en.ec21.com/Fluke_753_Documenting_Process_Calibrator--12030345_12045401.html]]></link><description><![CDATA[In The Box
BC7240 battery chargerLi-on BP7240 battery packDPCTrack 2 Sample SoftwareInstruction manualNIST-traceable calibration report and dataThree sets of TP220 test probes with three sets of “e]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke 393-IRR-PVLEAD Solar Kit with True RMS Solar Clamp Meter, Irradiance Meter and MC4 Test Leads]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_393_IRR_PVLEAD_Solar--11927627_12044264.html]]></link><description><![CDATA[Included with the Fluke 393-IRR-PVLEAD
True RMS Clamp Meter
Solar Irradiance Meter
Test Leads, Right Angle Plugs with Safety Caps
Flexible Current Probe
MC4 Test Lead Set
MC4 Solar Clamp Test Lead Se]]></description><pubDate><![CDATA[20250220]]></pubDate></item>
<item>
<title><![CDATA[Hall Effect Thickness Gauge(Magnetic Bottle Thickness Gauge)]]></title><link><![CDATA[https://sookiecanneed.en.ec21.com/Hall_Effect_Thickness_Gauge_Magnetic--12024209_12027724.html]]></link><description><![CDATA[test, place the steel ball on one side of the sample and the probe on the other side. The Hall Effect sensor on the probe measures the distance from the probe tip to the steel ball. The calculator wi]]></description><pubDate><![CDATA[20241127]]></pubDate></item>
<item>
<title><![CDATA[YH701 Temperature and Humidity Calibration Device]]></title><link><![CDATA[https://yuanhuatc66.en.ec21.com/YH701_Temperature_and_Humidity_Calibration--12022540_12022544.html]]></link><description><![CDATA[tested instruments, thus preventing the improper placement of the tested objects from affecting the calibration environment.
◆Two adjustment test holes are convenient for operation, and the inspect]]></description><pubDate><![CDATA[20241106]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator with HART Communication]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11561118_11561429.html]]></link><description><![CDATA[sets) TP220 test probes(3 sets) &quot;extended tooth&quot; alligator clips(2 sets) AC280 hook clipsC799 Soft Field CaseUSB communication cable, Fluke 754HHC HART communications cableQuick Reference Guide]]></description><pubDate><![CDATA[20240921]]></pubDate></item>
<item>
<title><![CDATA[Emcee Model 1152 Digital Conductivity Meter]]></title><link><![CDATA[https://xmjielian.en.ec21.com/Emcee_Model_1152_Digital_Conductivity--11982130_11982334.html]]></link><description><![CDATA[Model 1152 Digital Conductivity Meter(ASTMStandard Test Method D 2624 included in Specifications D975, D1655, and D7566)
Continuous standard electrical conductivity range from 1 to 2000 in increments]]></description><pubDate><![CDATA[20240813]]></pubDate></item>
<item>
<title><![CDATA[Multi Channel Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Multi_Channel_Ultrasonic_Flaw_Detector--11973711_11973720.html]]></link><description><![CDATA[Multi Channel Ultrasonic Flaw Detector
Introduction
The instrument incorporates many advanced signal processing features including a 15MHz RF bandwidth to permit testing of thin materials, narrowband]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[NDJ-8T Lab Digital Rotating Viscosity Meter Viscosimeter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_8T_Lab_Digital_Rotating--11144324_11144457.html]]></link><description><![CDATA[probe interface (requires optional temperature probe)
Automatic scanning function
Automatically scan and recommend a priority combination of rotor and speed
Display measurement range
Automatic displa]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Gear Measuring Machine for Worm Wheel Rotary Table,Bevel Gear,]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Gear_Measuring_Machine_for_Worm--11944568_11945231.html]]></link><description><![CDATA[probes;
Having a complete set of independent intellectual property rights, multiple patented technologies, instrument functions, software configurations, and flexibility and diversity; 
The introduct]]></description><pubDate><![CDATA[20240531]]></pubDate></item>
<item>
<title><![CDATA[WIKA Instrument PASCAL100IS-4IPS-1IN-1OUT-HART-EPS-PR]]></title><link><![CDATA[https://moracalibration1.en.ec21.com/WIKA_Instrument_PASCAL100IS_4IPS_1IN--11937385_11937418.html]]></link><description><![CDATA[testing and calibration of industrial measuring instruments. The typical application is the calibration of pressure transmitters, temperature transmitters, pressure gauges, temperature probes and oth]]></description><pubDate><![CDATA[20240515]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[Probe, and to document tests using non-supported units such as parts per million or revolutions per minute.
User-entered Values 
Enables technicians to record calibration results that were sourced an]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Omniscan MX2 PA Flaw Detector]]></title><link><![CDATA[https://tol22man.en.ec21.com/Used_Olympus_Omniscan_MX2_PA--11836190_11836198.html]]></link><description><![CDATA[Olympus Omniscan MX2
Olympus Omniscan MX2 increases testing efficiencies, ensuring superior manual and advanced AUT application performance with faster setups, test cycles, and reporting, in addition]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[ICONE2]]></title><link><![CDATA[https://kobistq.en.ec21.com/ICONE2--1_11135288.html]]></link><description><![CDATA[The Analysis of Fire
The Cone Calorimeter is the most significant bench scale instrument in the field of fire testing. Heat release is the key measurement required to assess the fire development of m]]></description><pubDate><![CDATA[20200511]]></pubDate></item>
<item>
<title><![CDATA[NEW Digital Handheld Salt Tester DMT-20]]></title><link><![CDATA[https://dymeter.en.ec21.com/NEW_Digital_Handheld_Salt_Tester--1223564_3312029.html]]></link><description><![CDATA[testing 
Hydroponic feed delivery testing 
GENERAL FEATURES AND SPECIFICATIONS 
Auto Calibration &amp; Auto Temp.(C / F ) Exchange 
Gold plated waterproof sensor probes 
Hold button to freeze the reading]]></description><pubDate><![CDATA[20180303]]></pubDate></item>
<item>
<title><![CDATA[WASP-XM-R-SF6 Pump-priming Portable SF6 Gas Detector]]></title><link><![CDATA[https://mary00882009.en.ec21.com/WASP_XM_R_SF6_Pump--4088884_4088885.html]]></link><description><![CDATA[probe design, calibration easy; 
■ Maintenance more convenient in the future; 
■ Fault, Warning, operator error, alarm will be smart tips; 
■ Built-in CF calibration coefficients (VOC measureme]]></description><pubDate><![CDATA[20170411]]></pubDate></item>
<item>
<title><![CDATA[Olympus Omniscan SX 16:64 Flaw Detector]]></title><link><![CDATA[https://measurementequipment.en.ec21.com/Olympus_Omniscan_SX_16_64--11826058_11826059.html]]></link><description><![CDATA[tested according to MIL-STD-810G 516.6Ultrasound SpecificationsConnectors: 1 Phased Array connector: Olympus PA connectorConnectors: 2 UT connectors: LEMO 00Number of focal laws: 256Probe recognition]]></description><pubDate><![CDATA[20230728]]></pubDate></item>
<item>
<title><![CDATA[EMI Test Receiver]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/EMI_Test_Receiver--11882688_11882698.html]]></link><description><![CDATA[test 9k-30MHz radiation• LISUN AB-CLP Absorbing Clamp to test the home applications &amp; motor tools• LISUN VOL-CP RF Current Probe to the conducted disturbance voltage
Specification:• Detection f]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[V-Sorb 2800TP Surface Area and Porosimtery Analyzer]]></title><link><![CDATA[https://goldapp.en.ec21.com/V_Sorb_2800TP_Surface_Area--7277224_7277091.html]]></link><description><![CDATA[testing. It equipped with our multi pioneered technologies these make its performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a lea]]></description><pubDate><![CDATA[20240118]]></pubDate></item>
<item>
<title><![CDATA[NI ELVIS II Application Modules]]></title><link><![CDATA[https://iegieg.en.ec21.com/NI_ELVIS_II_Application_Modules--7052123_7052944.html]]></link><description><![CDATA[probe using Multisim to test the performance of the designed circuits. 
Students may use the built-in NI ELVIS II visual instrument and probe using Multisim to test the performance of the designed ci]]></description><pubDate><![CDATA[20121231]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Surface Roughness Tester SRT-6200]]></title><link><![CDATA[https://105landtek.en.ec21.com/Hot_Sale_Surface_Roughness_Tester--9545708_11803265.html]]></link><description><![CDATA[Test Principle
Inductance type
Radius of Probe Pin
10 um
Material of Probe Pin
Diamond
Measurement Force of Probe
16 mN（1.6 gf）
Probe Angle
90°
Vertical Radius of Guiding Head
48 mm
Maximum driv]]></description><pubDate><![CDATA[20230607]]></pubDate></item>
<item>
<title><![CDATA[High Precision Rotation Luminaire Goniophotometer]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/High_Precision_Rotation_Luminaire_Goniophotometer--9657760_11802783.html]]></link><description><![CDATA[test results with high accuracy. It is for industrial laboratory photometric data measurement of all kinds of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
High Precision]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Ulso High Acoustic Sensitivity Immersion Transducer]]></title><link><![CDATA[https://ulso2022.en.ec21.com/Ulso_High_Acoustic_Sensitivity_Immersion--11540612_11540613.html]]></link><description><![CDATA[test part is partially or wholly immersed .Advantages The immersion technique provides a means of uniform coupling Quarter wavelength matching layer increases sound energy outputCorrosion resistant 3]]></description><pubDate><![CDATA[20220308]]></pubDate></item>
<item>
<title><![CDATA[ETG12N1 Eddy Current Digital Paint Thickness Gauge]]></title><link><![CDATA[https://mikrometry.en.ec21.com/ETG12N1_Eddy_Current_Digital_Paint--11395794_11403080.html]]></link><description><![CDATA[Mikrometry Instrument Limited is testing and measuring instruments companies
of height gauge, force and torque measurement products, force gauge, digital torque gauge, paint gauge for cars
, cap torq]]></description><pubDate><![CDATA[20210621]]></pubDate></item>
<item>
<title><![CDATA[New Olympus BondMaster 600 Multimode Bond Tester]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_BondMaster_600_Multimode--11801594_11801602.html]]></link><description><![CDATA[testing inspection methods. The upgrade from basic to multimode can also be performed remotely.
Both BondMaster 600 models are compatible with existing Olympus BondMaster probes, including those equi]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Nirun Cone Plate Viscometerfor Sale]]></title><link><![CDATA[https://kobebean24.en.ec21.com/Nirun_Cone_Plate_Viscometerfor_Sale--11076331_11076337.html]]></link><description><![CDATA[probe
6.ARM chip processor:higher data processing speed
7.New designed durable axle
8.Powerful human-computer interactive interface
9.Gigabit Ethernet port:ensure rapid and stable data transfer
10.Ex]]></description><pubDate><![CDATA[20200310]]></pubDate></item>
<item>
<title><![CDATA[100V 120A 18650 Finished Battery Pack 100v200a 300a Tester for Lithium Battery Pack Assembly Line]]></title><link><![CDATA[https://aitop2018.en.ec21.com/100V_120A_18650_Finished_Battery--11585406_11639412.html]]></link><description><![CDATA[portCabinet Size850*700*920mmEquipment accessories Equipment accessories QuantityComputer, mouse, keyboard 1Comprehensive test instrument 1Test probe line 1User manual 1Computer software 1]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Lightning Surge Generator]]></title><link><![CDATA[https://15317383997.en.ec21.com/High_Voltage_Lightning_Surge_Generator--11812738_11812759.html]]></link><description><![CDATA[test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and current generator) . 
How does a surge generator work?The SG61000-5 surge generator provi]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[SPT for Soil Investigation Tianpeng 63.5kg CN;HEB 10kg 20kg 30kg Petrol Engine]]></title><link><![CDATA[https://tianpeng01.en.ec21.com/SPT_for_Soil_Investigation_Tianpeng--10975742_11481264.html]]></link><description><![CDATA[tests, compaction tests and for soil sampling. Dynamic probing standards DPL (10kg), DPM (30kg), DPH (50kg), DPSH (63.5kg) as well as SPT can be carried out.
Drop height can be varied between 500 and]]></description><pubDate><![CDATA[20230613]]></pubDate></item>
<item>
<title><![CDATA[Electric Motor Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/Electric_Motor_Testing_Equipment--11085938_11085967.html]]></link><description><![CDATA[test time range/resolution
0.5～999s 
0.1s/step
temperature compensation function
Yes
temperature probe/range
DS18b20 -10.0℃~+50.0℃
precision
±0.5°C（range: -10℃~+50℃）
Direction of rota]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Anti-yellowing Aging Test Chamber]]></title><link><![CDATA[https://annie0423.en.ec21.com/Anti_yellowing_Aging_Test_Chamber--9938796_9938808.html]]></link><description><![CDATA[Programmable Anti-yellowing Resistance Corrosion Tester
Product Description
Product description:
Accelerated Weather UV test machine is applicable for the sunlight resistant test of nonmetallic mater]]></description><pubDate><![CDATA[20160523]]></pubDate></item>

</channel>
</rss>