<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - us specification]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/us_specification--2717/1/us specification.html]]></link><item>
<title><![CDATA[Custom Optical Grating Replication Service | OEM Grating for Spectrophotometers]]></title><link><![CDATA[https://meticulab.en.ec21.com/Custom_Optical_Grating_Replication_Service--12069839_12069840.html]]></link><description><![CDATA[specifications, offering high-precision,
low-MOQ, fast-delivery solutions for R&amp;D labs, instrument manufacturers and industrial clients.
✅ Core Service &amp; Capabilities
Custom Grating Replication Ser]]></description><pubDate><![CDATA[20260420]]></pubDate></item>
<item>
<title><![CDATA[Medical Insulation Detector]]></title><link><![CDATA[https://maiyue.en.ec21.com/Medical_Insulation_Detector--12030943_12030951.html]]></link><description><![CDATA[specifications；（The unique adapter can be used to fix the probe tool to the detected facility）
★Voltage regulation: no gear type voltage regulation, 0~5000V adjustable, to meet the detection ]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO Thermal Imaging Camera]]></title><link><![CDATA[https://toolshed.en.ec21.com/Fluke_TI480_PRO_Thermal_Imaging--12045274_12045346.html]]></link><description><![CDATA[Specification
Features
IFOV with standard lens (spatial resolution): 0.93 mRad, D:S 1065:1Detector resolution: 640 x 480SuperResolution: Captures and combines 4x the data to create a 1280 x 960 (614,]]></description><pubDate><![CDATA[20250226]]></pubDate></item>
<item>
<title><![CDATA[Fluke TI480 PRO 60 Hz, 640 X 480 High-Performance IR Thermal Camera]]></title><link><![CDATA[https://aceinstuments.en.ec21.com/Fluke_TI480_PRO_60_Hz--11561118_11932301.html]]></link><description><![CDATA[specific areas of concern. IR-Fusion blends visible light and infrared images to capture a clear 5MP real-world picture of your target. Blend at different preset levels and add picture-in-picture (PI]]></description><pubDate><![CDATA[20250129]]></pubDate></item>
<item>
<title><![CDATA[Fluke TIX580 Infrared Camera]]></title><link><![CDATA[https://landsurvey.en.ec21.com/Fluke_TIX580_Infrared_Camera--11790575_11793442.html]]></link><description><![CDATA[Specifications: Fluke TiX580 Infrared Camera
Key featuresIFOV with standard lens (spatial resolution)0.93 mRad, D:S 1065:1Detector resolution640 x 480 (307,200 pixels)SuperResolutionYes, on camera an]]></description><pubDate><![CDATA[20250109]]></pubDate></item>
<item>
<title><![CDATA[WDLYCH/WDLHCN CCS Marine Analog Panel Current Meter/Ammeter for Switchboards]]></title><link><![CDATA[https://jade900920.en.ec21.com/WDLYCH_WDLHCN_CCS_Marine_Analog--11663243_12026218.html]]></link><description><![CDATA[specific instruments must strictly comply with classification requirements.Wei Dian analog panel instruments all comply with multiple standards such as CCS ,CE and ISO etc., which provides sufficient]]></description><pubDate><![CDATA[20241227]]></pubDate></item>
<item>
<title><![CDATA[Digital Distance Meter]]></title><link><![CDATA[https://holo1.en.ec21.com/Digital_Distance_Meter--11942959_11942957.html]]></link><description><![CDATA[Specifications:
1
Part No.
X-30
2
Measuring range
0.05~30m
3
Measuring accuracy
±3mm
4
Measurement speed
0.5~1S
5
Measurement unit
m
6
Continuous measurement
Yes
7
Charging
Type-C
8
Battery
Lithium ]]></description><pubDate><![CDATA[20241206]]></pubDate></item>
<item>
<title><![CDATA[Heat Alarm &amp; Detector Test Tunnel]]></title><link><![CDATA[https://mimayijingaile0.en.ec21.com/Heat_Alarm_Detector_Test_Tunnel--11987076_11987723.html]]></link><description><![CDATA[specifications and parameters, we use fast response thermocouples and
advanced PID controller to attain the heating rate of 0.2 ℃/min, 1 ℃/min, 3 ℃/min, 5 ℃/min,
10 ℃/min, 20 ℃/min and 30]]></description><pubDate><![CDATA[20241122]]></pubDate></item>
<item>
<title><![CDATA[Three-box High and Low Temperature Alternating Test Chamber]]></title><link><![CDATA[https://lenpure3852.en.ec21.com/Three_box_High_and_Low--11943432_12023864.html]]></link><description><![CDATA[conditions measured2、The above parameters are for reference only, and can be customized according to user-specific test parameters.3、This technical information, subject to change without notice
]]></description><pubDate><![CDATA[20241112]]></pubDate></item>
<item>
<title><![CDATA[UTOCO Handheld Laser Detector with Tdlas for Natural Gas Distribution Pipeline]]></title><link><![CDATA[https://utoco.en.ec21.com/UTOCO_Handheld_Laser_Detector_with--12010082_12010092.html]]></link><description><![CDATA[Specification: GasNatural gas (CH4)PrincipleTDLASSensitivity5ppm·mDetection range0~100000ppm·mDistance50 metersResponse timeT90 &lt; 0.1 secondWorking temperature-20ºC~50ºCStorage temperature-20ºC~]]></description><pubDate><![CDATA[20240926]]></pubDate></item>
<item>
<title><![CDATA[Portable Hardness Tester]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Portable_Hardness_Tester--11973711_12009824.html]]></link><description><![CDATA[Specifications
● Measuring range: (170-960) HLD, (17-68.5) HRC, (19-651) HB, (80-976) HV, (30-100) HS, (59-85) HRA, (13-100)HRB 
● Measuring direction: 360° ( ↓ ↖ ↗ ↘ ↙ → ← ↑ )
]]></description><pubDate><![CDATA[20240925]]></pubDate></item>
<item>
<title><![CDATA[EMCEE Model 1154 Precision Conductivity Meter]]></title><link><![CDATA[https://xmjielian.en.ec21.com/EMCEE_Model_1154_Precision_Conductivity--11982130_11982350.html]]></link><description><![CDATA[specific volume (100-mL) of test sample is introduced between the two concentric electrodes in the Cell. Using a triaxial cable, the Cell is connected to a sensitive dc ammeter in the Console and a d]]></description><pubDate><![CDATA[20240813]]></pubDate></item>
<item>
<title><![CDATA[Sell Universal Manhole Cover Compression Testing Machine]]></title><link><![CDATA[https://lgtester4.en.ec21.com/Sell_Universal_Manhole_Cover_Compression--9978752_10011324.html]]></link><description><![CDATA[specifications, manhole covers, water grate cover, well grate.
2. The host machine frame adopts two column structure, oil cylinder overhead; big working table 1500x1400mm; loading and unloading the m]]></description><pubDate><![CDATA[20240803]]></pubDate></item>
<item>
<title><![CDATA[NDJ-8T Lab Digital Rotating Viscosity Meter Viscosimeter]]></title><link><![CDATA[https://zotaimachine.en.ec21.com/NDJ_8T_Lab_Digital_Rotating--11144324_11144457.html]]></link><description><![CDATA[Specification:
Model
NDJ-5T
NDJ-5T
Control / display mode
5-inch color touch screen
Speed (r/min)
6/12/30/60
0.3/0.6/1.5/3/6/12/30/60
Measuring range 
1~100000mPa.s
1~2000000mPa.s
(1-10mPa.s, need to]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Cuvettes&amp;Cuvettes(Glass)&amp;Cuvettes (Quartz)]]></title><link><![CDATA[https://biogene123.en.ec21.com/Cuvettes_Cuvettes_Glass_Cuvettes_Quartz--11963552_11963584.html]]></link><description><![CDATA[specifications are available.
• Available in quartz or glass.
Use notes
1. Any solution containing substances that corrode glass (especially alkaline substances) shall not be placed in a colorimetr]]></description><pubDate><![CDATA[20240705]]></pubDate></item>
<item>
<title><![CDATA[Diameter Measuring Equipment]]></title><link><![CDATA[https://measurementon.en.ec21.com/Diameter_Measuring_Equipment--11962128_11962132.html]]></link><description><![CDATA[Applications
Manufacturing and Quality Control:
Ensuring parts and components meet precise specifications to maintain product quality and reduce waste.
Automotive and Aerospace:
Measuring engine comp]]></description><pubDate><![CDATA[20240703]]></pubDate></item>
<item>
<title><![CDATA[Xenon Lamp Weather Resistance Test Chamber]]></title><link><![CDATA[https://hydescience03.en.ec21.com/Xenon_Lamp_Weather_Resistance_Test--11164019_11167773.html]]></link><description><![CDATA[specifications:
Model 
QH-XD710HD
QH-XD780HD
Internal dimensions (D*W*H)
400*550*450 mm
950*950*900 mm
External dimensions (D*W*H)
1400*750*1500 mm
1840*1150*1900 mm
Performance 
Temperature range
-7]]></description><pubDate><![CDATA[20240624]]></pubDate></item>
<item>
<title><![CDATA[Large Size CNC CMM Measuring Machine Fotuna Series XYZ 203015]]></title><link><![CDATA[https://aehcmm.en.ec21.com/Large_Size_CNC_CMM_Measuring--11944568_11944823.html]]></link><description><![CDATA[Specification
No.
Model
Measuring range (mm)
Max Load. (kg)
Machine size (mm)
Machine 
Weight 
(kg)
Resolution 
MPEP (μm)
MPEE (μm)
Scanning probing error 
X
Y
Z
Lx
Ly
Lz
(μm)
TP20
TP200
SP25/SP80]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[RLK607 Contact Infrared Radiometer]]></title><link><![CDATA[https://gatherstar.en.ec21.com/RLK607_Contact_Infrared_Radiometer--11943208_11943310.html]]></link><description><![CDATA[Specifications 
Model 
RLK607
Principle 
Receive infrared radiation from material surface
Measure band 
2～30μm
Measuring range 
100μW/cm*cm～100mW/cm*cm (automatic range switching)
Display resol]]></description><pubDate><![CDATA[20240530]]></pubDate></item>
<item>
<title><![CDATA[ISO16750-4 Clause 5.4.2 Ice Water Splash Test Chamber for Automotive Parts]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/ISO16750_4_Clause_5.4.2_Ice--11940576_11941038.html]]></link><description><![CDATA[Specification
Outer size (L*W*H)
1500*1900*2250 (mm)
Inner size (L*W*H)
1000*1000*1000 (mm)
Spray nozzle
Slot jet*1 
Nozzle position
Right side of inner chamber 
Distance nozzle to device under test
]]></description><pubDate><![CDATA[20240522]]></pubDate></item>
<item>
<title><![CDATA[Smart Electricity Distribution Network Monitoring System]]></title><link><![CDATA[https://snova17.en.ec21.com/Smart_Electricity_Distribution_Network_Monitoring--10349843_10370312.html]]></link><description><![CDATA[Overhead Line Short Circuit And Earth Fault Indicator ( SNV-308 )
Specifications
SNV fault indicators can quickly and easily indicate fault and identify fault locations, used in cable and overhead po]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[HTT-02 Hot Tack Tester]]></title><link><![CDATA[https://materialstests.en.ec21.com/HTT_02_Hot_Tack_Tester--11896648_11938409.html]]></link><description><![CDATA[Specifications
Sealing Temp.
Ambient~250℃
Temp Accuracy
±0.2℃
Dwell Time
0.1~9999s(Heat Seal )
Dwell Time
0.1~9999s(Hot Tack )
Sealing Pressure
0.15MPa~0.7MPa
Sealing Jaws
50mmx10mm Teflon Coate]]></description><pubDate><![CDATA[20240517]]></pubDate></item>
<item>
<title><![CDATA[Sonic Nozzle Method Gas Flow Calibration System]]></title><link><![CDATA[https://tnmacalibration.en.ec21.com/Sonic_Nozzle_Method_Gas_Flow--11926262_11926271.html]]></link><description><![CDATA[specifications.
The LNQ-3000 Sonic Nozzle Gas Flow Standard Device is a gas flow standard device (negative pressure method) that utilizes a critical flow Venturi nozzle as a standard meter. This devi]]></description><pubDate><![CDATA[20240417]]></pubDate></item>
<item>
<title><![CDATA[Drop Test Machine]]></title><link><![CDATA[https://cmetechnology.en.ec21.com/Drop_Test_Machine--11925572_11925584.html]]></link><description><![CDATA[specific procedures
Now the price of reliability test equipment
is reasonable, if you have needs, please contact us.
If you want to know more kinds of impact testing equipment
, please visit our webs]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[High Voltage Wire Harnesses/Cables Testing Bench Top(Table) for Automotive]]></title><link><![CDATA[https://shcleanknow4567.en.ec21.com/High_Voltage_Wire_Harnesses_Cables--11923899_11923921.html]]></link><description><![CDATA[Specifications and Data: 
AC
Output Voltage 
Output
0.05-5Kv
Measurement Accuracy
1% + 
5v
Display Accuracy
2 V
Frequency
50Hz/60Hz
Power
150VA Max.
DC
Output
0.05-6Kv
Measurement Accuracy
1% + 5v
Di]]></description><pubDate><![CDATA[20240412]]></pubDate></item>
<item>
<title><![CDATA[Fluke 754 Documenting Process Calibrator and Hart Instrumentation]]></title><link><![CDATA[https://endangsurvey.en.ec21.com/Fluke_754_Documenting_Process_Calibrator--11329183_11550830.html]]></link><description><![CDATA[Specification:
The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable ]]></description><pubDate><![CDATA[20240408]]></pubDate></item>
<item>
<title><![CDATA[KRD50 Transportation Simulation Test System]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD50_Transportation_Simulation_Test_System--11098426_11099470.html]]></link><description><![CDATA[Specifications
Model
Parameters
KRD
50－200
KRD
50－300
KRD
50－600
KRD
50－1000
KRD
50－2000
KRD
50－3000
KRD
50－4000
KRD
50－6000
Max. Load
(kg)
200
300
600
1000
2000
3000
4000
6000
Vibrat]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Product Purchasing]]></title><link><![CDATA[https://maplesourcing1.en.ec21.com/Product_Purchasing--11917888_11917890.html]]></link><description><![CDATA[specific needs. 
For more information about purchasing and supply strategy and how to order from 1688
, please feel free to contact us!
If you are looking for a reliable global procurement company, d]]></description><pubDate><![CDATA[20240329]]></pubDate></item>
<item>
<title><![CDATA[Custom Breaking Strength Tester for Glass Ampoule Bottle]]></title><link><![CDATA[https://celtec.en.ec21.com/Custom_Breaking_Strength_Tester_for--9267551_9267648.html]]></link><description><![CDATA[Specifications
Test Range 0-200N (Standard)
Speed 10 mm/m (This speed is for ampoule breaking and other speeds available)
Dimension 400mm (L) ×340mm (W) ×800mm (H)
Power AC 220V 50Hz
Standard
YBB00]]></description><pubDate><![CDATA[20240325]]></pubDate></item>
<item>
<title><![CDATA[21.5 Inch Magazine Holder Digital Kiosk]]></title><link><![CDATA[https://rcstarsdisplay.en.ec21.com/21.5_Inch_Magazine_Holder_Digital--11540233_11857652.html]]></link><description><![CDATA[Specifications of 21.5 inch Magazine Holder Kiosk
Model No
RCS-220LP
RCS-320LP
Panel Model
21.5 inch TFT LED
32 inch TFT LED
Max Resolution
1920×1080
1920×1080
Aspect Ratio
16:09
16:09
Pixel Pitch
]]></description><pubDate><![CDATA[20231023]]></pubDate></item>
<item>
<title><![CDATA[Automatic Image Measuring Device]]></title><link><![CDATA[https://qiantongyiqi.en.ec21.com/Automatic_Image_Measuring_Device--11683816_11853605.html]]></link><description><![CDATA[specifications
model
QT-5040
Stroke（mm）
500 *400*200
Overall dimension （mm）
825*1077*1280
Worktable （mm）
660*560
Overall weight (kg)
420
Glass load (kg)
20
Z-axis lifting distance
200MM
W]]></description><pubDate><![CDATA[20231012]]></pubDate></item>
<item>
<title><![CDATA[Programmable Touch Screen Desktop Environmental Chamber]]></title><link><![CDATA[https://asliequipment.en.ec21.com/Programmable_Touch_Screen_Desktop_Environmental--11825687_11825716.html]]></link><description><![CDATA[specifications. That size that can fit on a personal desk is the most consideration.Features: Temperatue Humidity control and display unit.Desk top, Table top, Bench Top Fit.7inch big PLC touch scree]]></description><pubDate><![CDATA[20230727]]></pubDate></item>
<item>
<title><![CDATA[Multi-channel Multi-function Intelligent Temperature and Humidity Itinerant Detector]]></title><link><![CDATA[https://tadt2023.en.ec21.com/Multi_channel_Multi_function_Intelligent--11689589_11689607.html]]></link><description><![CDATA[specification 
The AMS2750E specification puts forward high measurement requirements for the accuracy of inspection equipment. Through the optimized design of the analog input channel and the tempera]]></description><pubDate><![CDATA[20221209]]></pubDate></item>
<item>
<title><![CDATA[Sonic Nozzle Gas Meter Test Bench]]></title><link><![CDATA[https://royreal.en.ec21.com/Sonic_Nozzle_Gas_Meter_Test--11907986_11908002.html]]></link><description><![CDATA[specifications of 4, 6, 8 and 12 epitopes to meet the efficiency requirements of different users.
Product Features
1. Leak Test, indication Error and Pressure Loss can be continuously tested at a tim]]></description><pubDate><![CDATA[20240301]]></pubDate></item>
<item>
<title><![CDATA[Walk-in Climatic Test Chamber]]></title><link><![CDATA[https://irfanzahidi.en.ec21.com/Walk_in_Climatic_Test_Chamber--11888169_11888182.html]]></link><description><![CDATA[inner chamber size, inner chamber stratification, temperature range, temperature 
change rate, and other specifications can be customized according to customers 
testing requirements]]></description><pubDate><![CDATA[20240117]]></pubDate></item>
<item>
<title><![CDATA[Salt Spray Tester]]></title><link><![CDATA[https://alibiota1431.en.ec21.com/Salt_Spray_Tester--11847960_11847976.html]]></link><description><![CDATA[specifications.
JOEO Salt Spray Tester, salt fog cabinet,corrosion chamber testing products are standard in every major automobile manufacturer in North America. We are the leader in salt corrosion t]]></description><pubDate><![CDATA[20231107]]></pubDate></item>
<item>
<title><![CDATA[ETG12N1 Eddy Current Digital Paint Thickness Gauge]]></title><link><![CDATA[https://mikrometry.en.ec21.com/ETG12N1_Eddy_Current_Digital_Paint--11395794_11403080.html]]></link><description><![CDATA[function allows for evaluation of a measurement series and display of the most significant characteristic statistical values.
Specifications of ETG12N Eddy Current Digital Paint Thickness Gauge
]]></description><pubDate><![CDATA[20210621]]></pubDate></item>
<item>
<title><![CDATA[New Olympus BondMaster 600 Multimode Bond Tester]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_BondMaster_600_Multimode--11801594_11801602.html]]></link><description><![CDATA[Specifications :
GeneralOverall Dimensions (W × H × D)236 mm × 167 mm × 70 mm (9.3 in. × 6.57 in. × 2.76 in.)
Weight1.70 kg (3.75 lb), including lithium-ion battery
Standards or DirectivesMil S]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Mercury Lamp Light Source System CEL-M500-T5]]></title><link><![CDATA[https://aulight2021.en.ec21.com/Mercury_Lamp_Light_Source_System--11446895_11446897.html]]></link><description><![CDATA[specifications, brands, imported and domestic filters and lenses (25.4mm, 50.8mm,,M52, M62, etc.), commonly used filter specifications (UV bandpass filters): 254nm, 313nm, 334nm, 350nm, 365nm, 380nm,]]></description><pubDate><![CDATA[20221027]]></pubDate></item>
<item>
<title><![CDATA[TJH-2C Parallel Beam Load Cell]]></title><link><![CDATA[https://tgloadcells.en.ec21.com/TJH_2C_Parallel_Beam_Load--11543401_11592317.html]]></link><description><![CDATA[Specifications of TJH-2C Parallel Beam Load Cell
Technical Parameter
Rated Load
0.5~10 kN
Comprehensive Precision
0.02~0.05% FS
Sensitivity
2.0 mV/V
Creep
±0.02% FS/30min
Zero Output
±1% FS
Tempera]]></description><pubDate><![CDATA[20220624]]></pubDate></item>
<item>
<title><![CDATA[Futina Metal Electrical Power Distribution Box B Series]]></title><link><![CDATA[https://futinaswitch.en.ec21.com/Futina_Metal_Electrical_Power_Distribution--11637911_11862326.html]]></link><description><![CDATA[Specification of Metal Electrical Power Distribution Box B Series
Product name
Flush mounted surface mounted MCB electrical power distribution box circuit breaker box
Material
ABS panel, metal box
Si]]></description><pubDate><![CDATA[20231103]]></pubDate></item>
<item>
<title><![CDATA[100V 120A 18650 Finished Battery Pack 100v200a 300a Tester for Lithium Battery Pack Assembly Line]]></title><link><![CDATA[https://aitop2018.en.ec21.com/100V_120A_18650_Finished_Battery--11585406_11639412.html]]></link><description><![CDATA[Specifications Input powerAC220V±10%/50HzNo load voltagemeasuring range0-100VCurrentCharging range0.1-20A Discharging range0.1-60A Charging over current4-20A Discharge over current4-120A resolution]]></description><pubDate><![CDATA[20240109]]></pubDate></item>
<item>
<title><![CDATA[Gold Supplier Programmable Constant Temperature and Humidity Testing Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Gold_Supplier_Programmable_Constant_Temperature--11372570_11372574.html]]></link><description><![CDATA[Specification test B: high temperature test method gb2423.2-89 (iec68-2-2);
Basic environmental test code for electrical and electronic products test Ca: constant humidity and heat test method GB/T 2]]></description><pubDate><![CDATA[20210424]]></pubDate></item>
<item>
<title><![CDATA[Used Olympus Omniscan MX2 PA Flaw Detector]]></title><link><![CDATA[https://tol22man.en.ec21.com/Used_Olympus_Omniscan_MX2_PA--11836190_11836198.html]]></link><description><![CDATA[specifications will continue to evolve with your needs through constant software updates.Includes:
Olympus Omniscan MX2 16:128 Phased Array Ultrasonic Flaw Detector (16:128 Module)BatteryChargerAcces]]></description><pubDate><![CDATA[20230821]]></pubDate></item>
<item>
<title><![CDATA[Snap On Compact Low Pressure Regulator Basic+Standard Type for A120is/ A121is/ A122is/ A127is]]></title><link><![CDATA[https://igtchina.en.ec21.com/Snap_On_Compact_Low_Pressure--11706713_11766924.html]]></link><description><![CDATA[Specifications
Inlet size options:
20/21/22/26/27mm/G61
Outlet size options:
8/10/11mm, thread 1/4&quot;LH
Outlet pressure options:
28mbar,29mbar,30mbar,37mbar
Capacity:
1.5kg/h
Excess flow:
With or witho]]></description><pubDate><![CDATA[20230410]]></pubDate></item>
<item>
<title><![CDATA[Dustproof Testing Machine | Dust Proof Chamber]]></title><link><![CDATA[https://15317383997.en.ec21.com/Dustproof_Testing_Machine_Dust_Proof--11812738_11858081.html]]></link><description><![CDATA[Specifications:• Temperature range: RT+10~50℃• Standard wire diameter of metal screen: 50um; Standard spacing between wires: 75um• Test dust: dry talc powder; Talc powder dosage: 2~4kg/m; Dus]]></description><pubDate><![CDATA[20231024]]></pubDate></item>
<item>
<title><![CDATA[Coefficient of Friction Tester]]></title><link><![CDATA[https://celtec2.en.ec21.com/Coefficient_of_Friction_Tester--11854816_11854821.html]]></link><description><![CDATA[specific materials involved. In the 
context of packaging film, the coefficient of friction refers to the extent of 
&apos;slipperiness&apos; exhibited by the packaging material when in contact with different ]]></description><pubDate><![CDATA[20231016]]></pubDate></item>
<item>
<title><![CDATA[IEC60529 Waterproof Testing Machine IPX12 Vertical Rain Drip Box]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC60529_Waterproof_Testing_Machine_IPX12--11405200_11418229.html]]></link><description><![CDATA[Specification: 
Model
IPX12B-800
IPX12B-1000
Drip board size (mm)
800*800
1000*1000
Outer size (mm)
1000*1000*2300 (L*W*H)
1200*1200*2300 (L*W*H)
Diameter of turntable
Φ500mm
Φ600mm
Aperture of noz]]></description><pubDate><![CDATA[20210722]]></pubDate></item>
<item>
<title><![CDATA[1 LED Module]]></title><link><![CDATA[https://hanway2022.en.ec21.com/1_LED_Module--11721610_11781491.html]]></link><description><![CDATA[Specification of 1 LED Modules
Item No.
Power
Size
LED Type
Angle
IP Class
HW-2835-1.5W
1.5W
35*25MM
3030
160°
IP68
HW-4830-1.5W
1.5W
48*30MM
3030
160°
IP68
HW-3625-1.5W
1.5W
36*25MM
3030
160°
IP6]]></description><pubDate><![CDATA[20230504]]></pubDate></item>
<item>
<title><![CDATA[CST-50 Impact Specimen U/V Notch Projector]]></title><link><![CDATA[https://wanchen123.en.ec21.com/CST_50_Impact_Specimen_U--11774583_11774608.html]]></link><description><![CDATA[Specifications:
Model: CST-50
Projector screen diameter: Φ200mm
Square work table dimension: 110*125mm
Round work table dimension: Φ90mm
Work table glass diameter: Φ70mm
Work table stroke Vertical]]></description><pubDate><![CDATA[20230529]]></pubDate></item>

</channel>
</rss>