<?xml version="1.0" encoding="utf-8" ?>
<rss version="2.0">
<channel>
<title><![CDATA[EC21 Product Catalogs - waveform]]></title>
<link><![CDATA[https://www.ec21.com/ec-market/waveform--2717/1/waveform.html]]></link><item>
<title><![CDATA[IEC61180-1 Impulse Withstand Voltage Generator with 1.2/50us Waveform]]></title><link><![CDATA[https://pegogroup.en.ec21.com/IEC61180_1_Impulse_Withstand_Voltage--11421920_11425210.html]]></link><description><![CDATA[Working power: 220V±10% AC, 50/60Hz
10) Dimension: 470mm*260mm*500mm (W*H*D)
11) Weight: 35KG 
4. Principle and waveform
1) 1.2/50ms surge waveform (generator section) equivalent circuit
]]></description><pubDate><![CDATA[20210805]]></pubDate></item>
<item>
<title><![CDATA[UTOCO Handhel Laser Natural Gas Detector for CNG and LNG Vehicles Methane Leak]]></title><link><![CDATA[https://utoco.en.ec21.com/UTOCO_Handhel_Laser_Natural_Gas--12010082_12010095.html]]></link><description><![CDATA[waveform and digital display in multiple units.
Low power consumption for extended monitoring through light-penetrable materials.
Uploads data to remote platforms via Bluetooth.
Specification: 
Measu]]></description><pubDate><![CDATA[20240926]]></pubDate></item>
<item>
<title><![CDATA[Ultrasonic Flaw Detector]]></title><link><![CDATA[https://ajrndt.en.ec21.com/Ultrasonic_Flaw_Detector--11973711_11973715.html]]></link><description><![CDATA[waveform from bright
Powerful PC software and reports can be export to excel
Function
● Automated display precise flaw location(Depth d, level p, distance s, amplitude, sz dB, ф)；
● Automated ]]></description><pubDate><![CDATA[20240723]]></pubDate></item>
<item>
<title><![CDATA[IEC61000-4-2 Electrostatic Discharge Generator with 20KV Output Voltage]]></title><link><![CDATA[https://pegoelectronics.en.ec21.com/IEC61000_4_2_Electrostatic_Discharge--11944039_11946383.html]]></link><description><![CDATA[Waveform of contact discharge
Meet the standards of EN/IEC 61000-4-2，GB/T 17626.2
Rising time:
0.8ns ±25％
First peak current
7.5A ±15％ @ 2kV
15A ±15％ @ 4kV
22.5A ±15％ @ 6kV
30A ±15％ ]]></description><pubDate><![CDATA[20240603]]></pubDate></item>
<item>
<title><![CDATA[Overhead Line Short-circuit and Ground Fault Indicator]]></title><link><![CDATA[https://snova17.en.ec21.com/Overhead_Line_Short_circuit_and--10349843_10360646.html]]></link><description><![CDATA[waveform changes to determine the short-circuit fault on the power lines and grounding fault, and the fault state, real time current (fault current), battery voltage, temperature, electric field of c]]></description><pubDate><![CDATA[20240520]]></pubDate></item>
<item>
<title><![CDATA[Fluke 1587 FC Advanced Electrical Troubleshooting Kit]]></title><link><![CDATA[https://focuscalibration.en.ec21.com/Fluke_1587_FC_Advanced_Electrical--11927627_11927693.html]]></link><description><![CDATA[waveforms add ± (2 % reading + 2 % FS) typical, for a crest factor up to 3.Input Impedance10 MΩ (nominal), &lt;100 pF, ac-coupledCommon mode rejection ratio (1 kΩ unbalanced)&gt;60 dB at dc, 50 or 60 Hz]]></description><pubDate><![CDATA[20240422]]></pubDate></item>
<item>
<title><![CDATA[KRD10 Hydraulic Vertical Shock Test System]]></title><link><![CDATA[https://cmetechnology.en.ec21.com/KRD10_Hydraulic_Vertical_Shock_Test--11925572_11925595.html]]></link><description><![CDATA[waveforms to realize shock energy that the product is subjected to in the actual environment, thereby improving the system or optimizing the structure of the product. This
shock test equipment meets ]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[VC5000A Power Quality Analyzer]]></title><link><![CDATA[https://cqsellbest.en.ec21.com/VC5000A_Power_Quality_Analyzer--11925671_11925688.html]]></link><description><![CDATA[waveforms, phasor diagrams, and harmonic ratio bar graphs; dynamically capture instantaneous changes in voltage and current, monitor starting current, monitor various power parameters and generate al]]></description><pubDate><![CDATA[20240416]]></pubDate></item>
<item>
<title><![CDATA[KRD13 High Energy Shock Test System]]></title><link><![CDATA[https://creditcme.en.ec21.com/KRD13_High_Energy_Shock_Test--11098426_11099352.html]]></link><description><![CDATA[Waveform
(Optional)
Half Sine Waveform
Bump 
Peak 
Acceleration 
(g)
5
～
100
5
～
80
5
～
60
5
～
40
/
Bump Pulse Duration(ms)
3
～
30
3
～
30
4
～
30
5
～
30
/
Bump Rate
(Times/Min)
10~80
1]]></description><pubDate><![CDATA[20240402]]></pubDate></item>
<item>
<title><![CDATA[Electrodynamic Vibration Generator System]]></title><link><![CDATA[https://lisungroup1.en.ec21.com/Electrodynamic_Vibration_Generator_System--9657760_11802794.html]]></link><description><![CDATA[waveform: sine wave (half wave and full wave). Acceleration speed: 0~20g (Adjustable)• Maximum test load capacity: 100kg• Accuracy: Frequency can be displayed to 0.01 Hz. Precision: 0.1 Hz.• Sw]]></description><pubDate><![CDATA[20230907]]></pubDate></item>
<item>
<title><![CDATA[Automatic Microcomputer Control Transformer Multi-functional Comprehensive Performance Test Bench]]></title><link><![CDATA[https://nanaoelec.en.ec21.com/Automatic_Microcomputer_Control_Transformer_Multi--10586983_10716645.html]]></link><description><![CDATA[waveform and temperature. 
The ratio of voltage to current can be set to directly display the measured value. 
The power-off latch can set the factory date and number. 
Can measure power in a low pow]]></description><pubDate><![CDATA[20180827]]></pubDate></item>
<item>
<title><![CDATA[Surge Generator]]></title><link><![CDATA[https://lisungroup7.en.ec21.com/Surge_Generator--11882688_11882701.html]]></link><description><![CDATA[waveform. Please visit LISUN CDN61000-5C to learn more details.Isolution Transformerfor EUT(External Optional)LISUN ITEU-SP4K (220V Single Phase) or ITUS-SP2K (110V Single Phase)LISUN ITEU-TP10K or I]]></description><pubDate><![CDATA[20240102]]></pubDate></item>
<item>
<title><![CDATA[Manufacturer Variable Frequency Series High Voltage AC Resonant Test System]]></title><link><![CDATA[https://kill235jklh.en.ec21.com/Manufacturer_Variable_Frequency_Series_High--10544358_10544744.html]]></link><description><![CDATA[waveform: sine wave, THD &amp;le; 1%. 
Full load working time: continuous working time 60mins. 
Quality factor: max. load &amp;ge; 30. 
Frequency adjustment: fineness 0.1Hz, instability &amp;le; 0.01%.
Over Curr]]></description><pubDate><![CDATA[20170921]]></pubDate></item>
<item>
<title><![CDATA[Gfuve Handheld Three Phase Energy Meter Calibrator]]></title><link><![CDATA[https://gfuve0123.en.ec21.com/Gfuve_Handheld_Three_Phase_Energy--10658139_11236551.html]]></link><description><![CDATA[waveform of U and I.Analyze and display content of harmonic of U and I.Measure 2-64 harmonic of U, I.Store and display measured data.Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.Me]]></description><pubDate><![CDATA[20200820]]></pubDate></item>
<item>
<title><![CDATA[DC Motor Armature Testing Equipment]]></title><link><![CDATA[https://aipinstrument.en.ec21.com/DC_Motor_Armature_Testing_Equipment--11085938_11085990.html]]></link><description><![CDATA[display value+2.5% measuring range+3words
Waveforms limited value
Minimum difference 0.1%
(waveform difference)
impulse internal setting
Available 
Sample frequency
20/40MHz（self-adjustable)
]]></description><pubDate><![CDATA[20200324]]></pubDate></item>
<item>
<title><![CDATA[Metal Oxide Surge Arrester Leakage Current Analyzer HFYH-8001B]]></title><link><![CDATA[https://hengfengtest.en.ec21.com/Metal_Oxide_Surge_Arrester_Leakage--11895397_11895400.html]]></link><description><![CDATA[waveform of voltage and current can be displayed on the large color screen. It can accurately analyze the content of fundamental wave and third to seventh harmonics, overcome the influence of inter-p]]></description><pubDate><![CDATA[20240130]]></pubDate></item>
<item>
<title><![CDATA[Power Quality Analyzer(3P)]]></title><link><![CDATA[https://tekon1.en.ec21.com/Power_Quality_Analyzer_3P--11010564_11156920.html]]></link><description><![CDATA[3-wire, three-phase 3-wire and three-phase 4-wire
• Displays voltage and current in waveforms and phase diagram
• EN50 160 Report Output
• Environment Temperature and humidity measurement
]]></description><pubDate><![CDATA[20201231]]></pubDate></item>
<item>
<title><![CDATA[New Olympus EPOCH 650 Ultrasonic Flaw Detector]]></title><link><![CDATA[https://117714.en.ec21.com/New_Olympus_EPOCH_650_Ultrasonic--11801594_11801598.html]]></link><description><![CDATA[Waveform Averaging• EP650-IG (Q1400005): Interface Gate• EP650-BEA (Q1400006): Backwall Echo Attenuator (BEA)• EP650-CORRSN (Q1400001): Corrosion Module (includes encoded B-scan)
Optional Acces]]></description><pubDate><![CDATA[20230604]]></pubDate></item>
<item>
<title><![CDATA[Hot Sale Furniture Mechanics Comprehensive Test Machine]]></title><link><![CDATA[https://lituotest.en.ec21.com/Hot_Sale_Furniture_Mechanics_Comprehensive--11365007_11365011.html]]></link><description><![CDATA[waveform and value respectively.
6. Each kind of test is not related, different tests are independent of each other, adding new tests or reducing a test does not affect the original test.
7.Unattende]]></description><pubDate><![CDATA[20210416]]></pubDate></item>
<item>
<title><![CDATA[DC Brushless Fan Motor Dynamometer]]></title><link><![CDATA[https://hzchangniu.en.ec21.com/DC_Brushless_Fan_Motor_Dynamometer--11882582_11882988.html]]></link><description><![CDATA[waveform (optional), phase sequence (optional), etc., complete all tests at one
wiring;
2.
The resistance test can automatically calculate the three-phase resistance
balance; The ambient temperature ]]></description><pubDate><![CDATA[20240222]]></pubDate></item>
<item>
<title><![CDATA[Ponovo POM2-3243 Universal Protection Relay Test System for Protective Relays]]></title><link><![CDATA[https://xiaxiaoming.en.ec21.com/Ponovo_POM2_3243_Universal_Protection--7403753_7403847.html]]></link><description><![CDATA[waveform display helps the fasttroubleshooting of wiring and test circuitry before testactual started. User can also use this provision to analyze the externalsignals, such as phase angle, power, har]]></description><pubDate><![CDATA[20230609]]></pubDate></item>

</channel>
</rss>